Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Demonstration of a time-integrated short line of sight neutron imaging system for inertial confinement fusion

The Neutron Imaging System (NIS) is an important diagnostic for understanding implosions of deuterium-tritium capsules at the National Ignition Facility. While the detectors for the existing system must be positioned 28 m from the source to produce sufficient imaging magnification and resolution, recent testing of a new short line of sight neutron imaging system has shown sufficient resolution to allow reconstruction of the source image with quality similar to that of the existing NIS on a 11.6 m line of sight. The new system used the existing pinhole aperture array and a stack of detectors composed of 2 mm thick high-density polyethylene converter material followed by an image plate. In these detectors, neutrons enter the converter material and interact with protons, which recoil and deposit energy within the thin active layer of the image plate through ionization losses. The described system produces time-integrated images for all neutron energies passing through the pinhole. We present details of the measurement scheme for this novel technique to produce energy-integrated neutron images as well as source reconstruction results from recent experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron techniques

Three experimental methods are described which hold the most promise for improved energy resolution, time resolution and sensitivity in the detection of solar neutrons on satellites and/or long duration balloon flights: the neutron calorimeter, the solar neutron track chamber, and the solar neutron decay proton detector. The characteristics of the three methods as to energy range, energy resolution, time resolution, detection efficiency, and physical properties are delineated. Earlier techniques to measure the intensity of high-energy cosmic-ray neutrons at the top of the atmosphere and to search for solar neutrons are described. The past three decades of detector development has now reached the point where it is possible to make comprehensive and detailed measurements of solar neutrons on future space missions.

Frye, Glenn M., Jr.↗

Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources

The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.

Cates, Joshua↗

Presentation to JAEA Visitors, July 24, 2012 [Slides]

There are 7 Reasons for characterizing spent fuel nuclide concentrations: (1) Provide IAEA with the capability to independently verify the mass of plutonium at any site that has spent fuel; (2) Shipper/receiver difference; (3) Determination of the input accountability mass of an electrochemical (pyro-chemical) processing facility; (4) Continuity of knowledge at spent fuel storage site; (5) Optimal reloads through knowledge of true actinide content; (6) Burnup credit for fuel transport and storage; and (7) Provide confidence to the public that the shipment of spent fuel around the world is being undertaken in a rigorous manner, assuring that material is not diverted during shipment. Types of fuel of interest are: Fast Reactor Fuel, Normal burnup low enriched uranium (LEU), Mixed oxide (MOX), Low burnup LEU, and Research reactor. MCNPX calculates the slowing down and the energy spread for a given time. The principles are: (1) Neutrons slow down in LSDS; (2) Slow neutrons capture preferentially on a fission resonance; (3) Fission emits high-energy neutrons; (4) High-energy neutrons detected in threshold detector (that is not sensitive to slow neutrons) (e.g., 238 U, 232 Th); and (5) The detection time is characteristic of the slow neutron energy. Following each PSR pulse, the entire signal is digitized in 2 nanosecond intervals, and subsequently analyzed Analysis involves applying a digital filter to extract fission pulses in a background of initial oscillations and noise throughout. Some of the noise is not random. Depending on the threshold setting and filter parameters, both the normalization and the trend change. Original PNNL LSDS design required a 1-meter radius cylindrical LSDS. Much higher efficiency would allow us to use a (1.2m) LSDS (this is the LANL LSDS size), or a less intense source, or a combination of both. We still estimate 10 16 total neutrons from the source to obtain 2-3% precision in 239 Pu and 235 U assay.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Active Inspection of Nuclear Materials Using {sup 4}He Scintillation Detectors

The detection of fissionable materials by neutron and high-energy photon active interrogation methods is explored using {sup 4}He scintillation detectors to search for prompt and delayed neutron signature. The low electron density of {sup 4}He in addition to its pulse shape discrimination capability allows strong rejection of gamma radiation. For the detection of the prompt neutron signatures, this capability is important as the signal produced by induced fission is accompanied by intense gamma radiation. The nanosecond time resolution of {sup 4}He scintillation detectors can be used for time-of-flight measurements aimed at determining the energy of the emitted neutrons. For delayed neutron detection, the insensitivity to the low energy neutrons present from non-signal reactions is inherent. Unlike detectors requiring a moderator, this technology can easily be collimated to reduce sensitivity to neutrons from outside the field of interest. The performance of the detectors for these applications is studied using GEANT4 computer modeling, based on measured detector parameters. A comparison is made with technologies typically used for these applications, i.e. heavily shielded organic scintillators for prompt neutron detection and Cd-lined {sup 3}He neutron detectors for the detection of delayed neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

Direct current response of a thin scCVD diamond detector under increased applied field to 14.1 MeV neutrons

An avalanche effect yielding inherent gain can be exploited in thin, single-crystal chemical vapor deposition (scCVD) diamond. It occurs when a high enough bias is applied across the diamond thickness while avoiding breakdown. This charge multiplication effect was studied previously with alpha particles and heavy ions either by using the transient current technique or by measuring the energy spectrum. The measurements we obtained to evaluate the charge multiplication performance of a 10 μm thick scCVD diamond detector used a novel approach—we employed an electrometer to characterize the response of the detector by performing directly coupled current measurements (time-averaged charge, at 1 Hz sampling) when exposed to 14.1 MeV neutrons from deuterium-tritium fusion. We measured both the dark and irradiated currents from the detector over a range of applied displacement field values from 2 to 75 V/μm. A histogram method with central mean and standard deviation width was used to determine the current over each measurement duration typically from 100 to 300 seconds. The dark-subtracted irradiated current (i.e., contrast) was used to evaluate the gain of the detector at each applied displacement field. The contrast at an applied displacement field between 15 and 20 V/μm was higher than the expected linear increase in contrast proportional to the increased applied bias, indicating the possible presence of avalanche events in the diamond. The detector response also indicated possible polarization and charge depletion effects. These results provide an opportunity to further explore the use of thin scCVD diamond as a fast neutron current mode detector with inherent gain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of spectral unfolding techniques for neutron spectroscopy

The precision of the JET installations of MAXED, GRAVEL and the L-curve version of MAXED has been evaluated by using synthetic neutron spectra. We have determined the number of counts needed for the detector systems NE213 and MPR to get an error below 10% of the MAXED unfolded neutron spectra is determined to be {approx}10{sup 6} and {approx}10{sup 4}, respectively. For GRAVEL the same number is {approx}10{sup 7} and {approx}3{center_dot}10{sup 4} for NE213 and MPR, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation measurements in low Earth orbit: U.S. and Russian results

The radiation environment in low-Earth orbital flights is complex. It is strongly influenced by altitude, orbital inclination, time within a given solar cycle, flight duration, and shielding configuration. At any specified shielded location, both primary and secondary particles generated by nuclear interactions of primary particles with spacecraft structure are present. In addition, there are atmospheric secondary albedo protons and neutrons. No single detector can adequately measure this complex radiation field, and measurements of very high linear energy transfer target fragmentation products are particularly difficult. Crew radiation exposure have exclusively been measured using passive thermoluminescent detectors (TLDs). The cosmonaut exposures on the Mir station, uncorrected for the TLD inefficiency and neutron contribution, have varied from a low of 2.43 cGy to a high of 8.70 cGy. These correspond to dose rates of 144 microGy d(-1) to 468 microGy d(-1). These are consistent with rates observed by the D2 ion-chamber. Using the rates measured by the D1 chamber, dose rates under 4 cm of water vary from about 60 microGy d-1 to about 350 microGy d(-1). There is variation of about a factor of two between the dose rates at various locations in the same module. There is also a variation of dose rates of about a factor two between various modules. The highest astronaut dose for a Shuttle flight (STS-82) was 3.205 cGy with a dose rate of 3,221 microGy d(-1). Neutron contribution could be 36 +/- 15% of the astronaut charged particle dose equivalent. East-West asymmetry of dose rate is significant for spacecrafts that fly in an fixed altitude, such as the International Space Station.

NASA Center JSC↗

Opportunities for Undergraduate Research in Nuclear Physics

University of Dallas (UD) physics majors are offered a variety of undergraduate research opportunities in nuclear physics through an established program at the University of Kentucky Accelerator Laboratory (UKAL). The 7-MV Model CN Van de Graaff accelerator and the neutron production and detection facilities located there are used by UD students to investigate how neutrons scatter from materials that are important in nuclear energy production and for our basic understanding of how neutrons interact with matter. Recent student projects include modeling of the laboratory using the neutron transport code MCNP to investigate the effectiveness of laboratory shielding, testing the long-term gain stability of C 6 D 6 liquid scintillation detectors, and deducing neutron elastic and inelastic scattering cross sections for 12 C. Finally, results of these student projects are presented that indicate the pit below the scattering area reduces background by as much as 30%; the detectors show no significant gain instabilities; and new insights into existing 12 C neutron inelastic scattering cross-section discrepancies near a neutron energy of 6.0 MeV are obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Resource Prospector Neutron Spectrometer System: RP's Bloodhound

The primary goal of the Resource Prospector Neutron Spectrometer System (NSS) is to locate and characterize hydrogen-bearing volatile deposits, especially subsurface ice, that may exist at the lunar poles. A key objective is to detect water-equivalent hydrogen concentrations of 0.5 wt% or greater while on a moving rover. A second objective is to determine approximate burial depth of enhanced hydrogen-bearing materials up to 1 meter below otherwise dry regolith. The instrument will be carried aboard a landed mobility system at the lunar poles. The instrument operates by measuring the changes in the leakage flux of low energy neutrons out of the regolith. These neutrons are produced by galactic cosmic rays, which are so energetic that they shatter the nuclei in surface materials. The neutrons interact with other nuclei and lose energy, becoming thermalized in the process. Hydrogen is most efficient at thermalizing neutrons owing to protons' similar mass - statistically, neutrons lose half their energy per collision with protons. With hydrogen in the soil, leakage fluxes of neutrons in the 0.5 eV to 500 keV energy range are reduced. A concentration of only1-2 wt% water-equivalent hydrogen results in a decrease in epithermal leakage flux of a factor of two. The leakage flux of thermal neutrons, from 0 to 0.5 eV in energy, can either increase or decrease depending on the hydrogen abundance and stratigraphy. As with the highly successful Lunar Prospector Neutron Spectrometer, the RP NSS detects both thermal and epithermal neutrons by using two helium-3 gas proportional counters, one covered by cadmium and the other uncovered. The former detects only epithermal neutrons with energies above approximately 0.5 eV, the latter detects both thermal (less than 0.5 eV) and epithermal energies (greater than 0.5 eV). When a neutron enters the detector tube and interacts with a helium-3 nucleus, the resulting reaction produces an energetic proton and triton that ionize the gas. The resulting electrons are accelerated toward a high-voltage anode and cascade, amplifying the net charge, which is collected at the anode. The number of electrons produced is proportional to the energy that the triton and proton deposit in the gas. A charge sensitive pre-amplifier converts the total charge to a step voltage output. A shaper amplifier then shapes this step into a uni-polar waveform with peaking time appropriate for the detection depending on the event rate. The integrated shaped waveform, representing the deposited triton/proton energy, is then measured. A histogram, or pulse height analysis, is performed to record the main capture peak and wall effect pulses. A threshold for detection is also required to limit the low amplitude counting rate such as noise floor. The system electronics consists of 2 modules - the Sensor Module (SM) front-end and the Data Processing Module (DPM) back-end circuits. SM is designed as a light-weight and low power front-end housing the two helium-3 proportional counter detectors, preamp and HVPS. It is mounted external to the rover body to detect the thermalized neutron flux with a minimum of host background. The DPM is located inside the rover; it digitizes the SM signals, performs pulse height analysis and accumulates the count rate for each spectral channel. The DPM controls high voltage and thresholding, and sends the science data to the host craft via an RS422 serial asynchronous protocol. The payload host provides all thermal management and control for the SM and DPM.

hydrogen-bearing volatile deposits↗

Neutron Measurement Instrumentation Development at KIT for the European ITER TBM

Fusion power reactors will rely on the internal production of the fuel tritium from lithium in the tritium breeding blanket. Test Blanket Modules (TBM) will be installed in ITER with the aim to investigate the nuclear performance of different breeding blanket designs. Currently there is no fully qualified nuclear instrumentation available for the measurement of neutron fluxes and tritium production rates which would be able to withstand the harsh environment conditions in the TBM such as high temperature (>400 deg. C) and, depending on the operation scenario, intense radiation levels. As partner of the European Consortium on Nuclear Data and Measurement Techniques in the framework of several F4E specific grants and contracts, KIT and ENEA have jointly studied the possibility to develop and test detectors suitable to operate in ITER-TBMs. Here we present an overview of ongoing work on three types of neutron flux monitors under development for the TBMs with focus on the KIT activities. A neutron activation system (NAS) with pneumatic sample transport could provide absolute neutron flux measurements in selected positions. A test system for investigating activation materials with short half-lives was constructed at the DT neutron generator laboratory of Technical University of Dresden to investigate the neutronics aspects. Several irradiations have been performed with focus on the simultaneous measurement of the extracted activated probes. An engineering assessment of a TBM NAS in the conceptual design phase has been done which considered issues of design requirements and integration. Last but not least, a mechanical test bench is under construction at KIT which will address issues of driving the activation probes, solutions for loading the system etc. experimentally. Self-powered neutron detectors (SPND) are widely applied in fission reactor monitoring, and the commercially available SPNDs are sensitive to thermal neutrons. We are investigating novel materials for SPND which would be sensitive also to the fast neutron flux expected in the TBMs. To this end simulations were done with the European Activation System EASY and neutron flux spectra which were calculated with MCNP for the HCPB TBM. Preliminary tests with commercial SPND in a fast reactor were performed. As a result of these activities, several materials have been found which may be suitable for the measurement of fast neutron fluxes in the TBM. Test detectors are under preparation for testing with DT neutron generators. Within the I{sub S}MART project, funded by KIC InnoEnergy, KIT is developing an online detector based on silicon carbide electronics for the TBMs. The operation of such detectors at TBM relevant temperatures is expected to incur lower accumulated radiation damage to them than at room temperature due to annealing effects. Detectors of several designs have been already irradiated with DT neutrons. Irradiation tests at elevated temperatures have been done and further tests are currently underway. This paper summarizes the status of the work for these three neutron flux monitor systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surrogate 239Pu(n, fxn) and 241Pu(n, fxn) average fission-neutron-multiplicity measurements

We have constructed a new neutron-charged-particle detector array called NeutronSTARS. It has been described extensively in LLNL-TR-703909 [1] and Akindele et al [2]. We have used this new neutron-charged-particle array to measure the 241Pu and 239Pu fissionneutron multiplicity as a function of equivalent incident-neutron energy from 100 keV to 20 MeV. The experimental approach, detector array, data analysis, and results are summarized in the following sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Organic Scintillator for Real-Time Neutron Dosimetry

We have developed a radiation detector based on an organic scintillator for spectrometry and dosimetry of out-of-field secondary neutrons from clinical proton beams. The detector consists of an EJ-299-34 crystalline organic scintillator, coupled by fiber optic cable to a silicon photomultiplier (SiPM). Proof of concept measurements were taken with 137 Cs and 252 Cf, and corresponding simulations were performed in MCNPX-PoliMi. Despite its small size, the detector is able to discriminate between neutron and gamma-rays via pulse shape discrimination. We simulated the response function of the detector to monoenergetic neutrons in the 100 keV–0 MeV range using MCNPX-PoliMi. The measured unfolded 252 Cf neutron spectrum is in good agreement with the theoretical Watt fission spectrum. We determined the ambient dose equivalent by folding the spectrum with the fluence-to-ambient dose conversion coefficient, with a 1.4% deviation from theory. Some preliminary proton beam experiments were preformed at the Bronowice Cyclotron Center patient treatment facility using a clinically relevant proton pencil beam for brain tumor and craino-spinal treatment directed at a child phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interactive automated Bragg peak identification with 3D neutron scattering data

Neutron scattering experiments have undergone significant technological development through large area detectors with concurrent enhancements in neutron transport and electronic functionality. Data collected for neutron events include detector pixel location in 3D, time and associated metadata, such as, sample orientation, neutron wavelength, and environmental conditions. RadiaSoft and Oak Ridge National Laboratory personnel are considering single-crystal diffraction data from the TOPAZ instrument. We are leveraging a new method for rapid, interactive analysis of neutron data using NVIDIA’s IndeX 3D volumetric visualization framework. We have implemented machine learning techniques to automatically identify Bragg peaks and separate them from diffuse backgrounds and analyze the crystalline lattice parameters for further analysis. The implementation of automatic peak identification into IndeX allows scientists to visualize and analyze data in real-time. Our methods include a robust comparison with current analysis techniques which show improvement in a variety of aspects. These improvements will be incorporated into IndeX for visualization to allow scientists an interactive tool for crystal analysis.

Kilpatrick, Matthew↗

Unifying measurement of Pu 239 ( n , γ ) in the keV to MeV energy regime

A single, unifying measurement of the 239 Pu capture cross section from 1 keV to 1.3 MeV has been performed for the first time using the Detector for Advanced Neutron Capture Experiments (DANCE) at the Los Alamos Neutron Science Center (LANSCE). The experimental method combines a prior experiment's characterization of prompt fission γ rays in conjunction with a fission tagging detector with a separate experiment using a thick 239 Pu sample to extract the neutron capture cross section in ratio to 239 Pu (n, f). We have made new predictions of the capture cross section taking into account recent results for the M1 scissors mode present in other actinides. The results show deviations from current evaluations which are 30% higher at the highest energies, and will be used to improve calculations relevant for several applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Emission Characteristics of Two Mixed-Oxide Fuels: Simulations and Initial Experiments

Simulations and experiments have been carried out to investigate the neutron emission characteristics of two mixed-oxide (MOX) fuels at Idaho National Laboratory (INL). These activities are part of a project studying advanced instrumentation techniques in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and it's Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. This analysis used the MCNP-PoliMi Monte Carlo simulation tool to determine the relative strength and energy spectra of the different neutron source terms within these fuels, and then used this data to simulate the detection and measurement of these emissions using an array of liquid scintillator neutron spectrometers. These calculations accounted for neutrons generated from the spontaneous fission of the actinides in the MOX fuel as well as neutrons created via (alpha,n) reactions with oxygen in the MOX fuel. The analysis was carried out to allow for characterization of both neutron energy as well as neutron coincidences between multiple detectors. Coincidences between prompt gamma rays and neutrons were also analyzed. Experiments were performed at INL with the same materials used in the simulations to benchmark and begin validation tests of the simulations. Data was collected in these experiments using an array of four liquid scintillators and a high-speed waveform digitizer. Advanced digital pulse-shape discrimination algorithms were developed and used to collect this data. Results of the simulation and modeling studies are presented together with preliminary results from the experimental campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗