Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Quantized Chiral Magnetic Current from Reconnections of Magnetic Flux

We introduce a new mechanism for the chiral magnetic e ect that does not require an initial chirality imbalance. The chiral magnetic current is generated by reconnections of magnetic ux that change the magnetic helicity of the system. The resulting current is entirely determined by the change of magnetic helicity, and it is quantized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gate-Tunable Phonon Magnetic Moment in Bilayer Graphene

Here we develop a first-principles quantum scheme to calculate the phonon magnetic moment in solids. As a showcase example, we apply our method to study gated bilayer graphene, a material with strong covalent bonds. According to the classical theory based on the Born effective charge, the phonon magnetic moment in this system should vanish, yet our quantum mechanical calculations find significant phonon magnetic moments. Furthermore, the magnetic moment is highly tunable by changing the gate voltage. Our results firmly establish the necessity of the quantum mechanical treatment, and identify small-gap covalent materials as a promising platform for studying tunable phonon magnetic moment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SSRF Beamline Control System

There are seven beamlines in the Phase-I of SSRF. Five of them are equipped with Insertion Devices, while two with Bending Magnets. The beamline control system is based on the standard hardware and software architecture. The VME(PowerPC) with VxWorks is used for motion control, while the personal computers with Scientific Linux are the front end controllers of equipment protection and personnel safety systems. The control software is developed under EPICS which makes various experimental programs of Blu-Ice, LabView, VC and SPEC conveniently access Monochromators, mirror chambers and other optical components.

43 PARTICLE ACCELERATORS↗

Study of magnetic metal periodic structures by X-Ray and electron microscopy methods

Complex studies of magnetic periodic metallic systems based on Dy/Gd layers have been carried out by X-ray diffraction, resonance X-ray reflectometry, transmission electronic microscopy, and energydispersve microanalysis. The application of these methods and joint analysis of their results provide an effective approach to study of the structure and determination of the parameters of individual layers and interfaces and their structural quality with a high degree of reliability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spin-1 microcondensate in a magnetic field

We study a spin-1 Bose-Einstein condensate small enough to be treated as a single magnetic domain: a system that we term a microcondensate. Because all particles occupy a single spatial mode, this quantum many-body system has a well-defined classical limit consisting of three degrees of freedom, corresponding to the three macroscopically occupied spin states. We study both the classical limit and its quantization, finding an integrable system in both cases. Depending on the sign of the ratio of the spin interaction energy and the quadratic Zeeman energy, the classical limit displays either a separatrix in phase space or Hamiltonian monodromy corresponding to nontrivial phase space topology. We discuss the quantum signatures of these classical phenomena using semiclassical quantization as well as an exact solution using the Bethe ansatz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chiral symmetry and scale invariance breaking in spin chains

The effects of the Dzyaloshinsky-Moriya interaction on finite size one-dimensional (1D) magnetic chains are investigated as a function of their length. The magnetic configuration the system adopts for varying boundary conditions are explored analytically, which leads to the appearance of chiral configurations that play a crucial role. The coercive and exchange bias fields show an unexpected chain length dependence, caused by the boundary conditions and by chiral symmetry breaking, which in turn leads to the breakdown of scale-invariance. Our treatment yields results in agreement with experimental evidence and ongoing research on phthalocyanine iron chains bonded to hydrogen.

36 MATERIALS SCIENCE↗

WIND-DRIVEN ACCRETION IN PROTOPLANETARY DISKS. I. SUPPRESSION OF THE MAGNETOROTATIONAL INSTABILITY AND LAUNCHING OF THE MAGNETOCENTRIFUGAL WIND

We perform local, vertically stratified shearing-box MHD simulations of protoplanetary disks (PPDs) at a fiducial radius of 1 AU that take into account the effects of both Ohmic resistivity and ambipolar diffusion (AD). The magnetic diffusion coefficients are evaluated self-consistently from a look-up table based on equilibrium chemistry. We first show that the inclusion of AD dramatically changes the conventional picture of layered accretion. Without net vertical magnetic field, the system evolves into a toroidal field dominated configuration with extremely weak turbulence in the far-UV ionization layer that is far too inefficient to drive rapid accretion. In the presence of a weak net vertical field (plasma {beta} {approx} 10{sup 5} at midplane), we find that the magnetorotational instability (MRI) is completely suppressed, resulting in a fully laminar flow throughout the vertical extent of the disk. A strong magnetocentrifugal wind is launched that efficiently carries away disk angular momentum and easily accounts for the observed accretion rate in PPDs. Moreover, under a physical disk wind geometry, all the accretion flow proceeds through a strong current layer with a thickness of {approx}0.3H that is offset from disk midplane with radial velocity of up to 0.4 times the sound speed. Both Ohmic resistivity and AD are essential for the suppression of the MRI and wind launching. The efficiency of wind transport increases with increasing net vertical magnetic flux and the penetration depth of the FUV ionization. Our laminar wind solution has important implications on planet formation and global evolution of PPDs.

79 ASTRONOMY AND ASTROPHYSICS↗

XMCD experimental station optimized for ultrathin magnetic films at HiSOR-BL14

We have constructed a system for in situ X-ray magnetic circular dichroism (XMCD) measurements of ultrathin magnetic films at the soft X-ray beamline HiSOR-BL14 at Hiroshima Synchrotron Radiation Center. The XMCD experimental station is directly connected to the beamline, and equipped with a sample fabrication chamber where various types of ultrathin magnetic films can be grown with monatomic layer control. XMCD spectra of the as-grown samples can be measured with adequate precision for the analysis of magnetic moments, under proper control of the light polarization in the beamline optics. This system has enabled the investigation of natural magnetic states in the ultrathin magnetic films without the influence of surface oxidation or any cap-layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic excitations in underdoped Ba(Fe1-xCox)2As2 with x=0.047

The magnetic excitations in the paramagnetic-tetragonal phase of underdoped Ba(Fe0.953Co0.047)2As2, as measured by inelastic neutron scattering, can be well described by a phenomenological model with purely diffusive spin dynamics. At low energies, the spectrum around the magnetic ordering vector QAFM consists of a single peak with elliptical shape in momentum space. At high energies, this inelastic peak is split into two peaks across the direction perpendicular to QAFM. We use our fittings to argue that such a splitting is not due to incommensurability or propagating spin-wave excitations, but is rather a consequence of the anisotropies in the Landau damping and in the magnetic correlation length, both of which are allowed by the tetragonal symmetry of the system. We also measure the magnetic spectrum deep inside the magnetically ordered phase, and find that it is remarkably similar to the spectrum of the paramagnetic phase, revealing the strongly overdamped character of the magnetic excitations.

36 MATERIALS SCIENCE↗

TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

60 APPLIED LIFE SCIENCES↗

Large magnetocapacitance in electronic ferroelectric manganite systems

We have observed a sizable positive magnetocapacitance (∼5%–90%) in perovskite Pr{sub 0.55}Ca{sub 0.45}MnO{sub 3} and bilayer Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} system under 5 T magnetic field across 20–100 K below the magnetic transition point T{sub N}. The magnetodielectric effect, on the other hand, exhibits a crossover: (a) from positive to negative for the perovskite system and (b) from negative to positive for the bilayer system over the same temperature range. The bilayer Pr(Sr{sub 0.1}Ca{sub 0.9}){sub 2}Mn{sub 2}O{sub 7} system exhibits a sizable anisotropy as well. We have also noticed the influence of magnetic field on the dielectric relaxation characteristics of these systems. These systems belong to a class of improper ferroelectrics and are expected to exhibit charge/orbital order driven ferroelectric polarization below the transition point T{sub CO}. Large magnetocapacitance in these systems shows a typical multiferroic behavior even though the ferroelectric polarization is small in comparison to that of other ferroelectrics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carbon Systems

The electronic states of a 'quantum dot-graphene monolayer-SiO{sub 2} + n{sup +}-Si substrate' system in an external magnetic field are studied. An analytical expression for charge transfer in this system is obtained. The electronic states of a 'quantum dot-graphene bilayer-SiO{sub 2} + n{sup +}-Si substrate' system are considered. The systems under study are interesting from the viewpoint of controlling the optical properties of a quantum dot by means of an applied electric field.

36 MATERIALS SCIENCE↗

Thermodynamics of magnetized binary compact objects

Binary systems of compact objects with electromagnetic field are modeled by helically symmetric Einstein-Maxwell spacetimes with charged and magnetized perfect fluids. Previously derived thermodynamic laws for helically symmetric perfect-fluid spacetimes are extended to include the electromagnetic fields, and electric currents and charges; the first law is written as a relation between the change in the asymptotic Noether charge {delta}Q and the changes in the area and electric charge of black holes, and in the vorticity, baryon rest mass, entropy, charge and magnetic flux of the magnetized fluid. Using the conservation laws of the circulation of magnetized flow found by Bekenstein and Oron for the ideal magnetohydrodynamic fluid, and also for the flow with zero conducting current, we show that, for nearby equilibria that conserve the quantities mentioned above, the relation {delta}Q=0 is satisfied. We also discuss a formulation for computing numerical solutions of magnetized binary compact objects in equilibrium with emphasis on a first integral of the ideal magnetohydrodynamic-Euler equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adjustable permanent magnet assembly for NMR and MRI

System and methods for designing and using single-sided magnet assemblies for magnetic resonance imaging (MRI) are disclosed. The single-sided magnet assemblies can include an array of permanent magnets disposed at selected positions. At least one of the permanent magnets can be configured to rotate about an axis of rotation in the range of at least +/-10 degrees and can include a magnetization having a vector component perpendicular to the axis of rotation. The single-sided magnet assemblies can further include a magnet frame that is configured to hold the permanent magnets in place while allowing the at least one of the permanent magnets to rotate about the axis of rotation.

42 ENGINEERING↗

Medium-Entropy Engineering of Magnetism in Layered Antiferromagnet Cu x Ni 2(1- x ) Cr x P 2 S 6

Antiferromagnetic van der Waals-type M 2 P 2 X 6 compounds provide a versatile material platform for studying 2D magnetism and relevant phenomena. Establishing ferromagnetism in 2D materials is technologically valuable. Though magnetism is generally tunable via a chemical way, it is challenging to induce ferromagnetism with isovalent chalcogen and bimetallic substitutions in M 2 P 2 X 6 . Here, we report co-substitution of Cu 1+ and Cr 3+ for Ni 2+ in Ni 2 P 2 S 6 , creating Cu x Ni 2(1-x) Cr x P 2 S 6 medium-entropy alloys spanning a full substitution range (x = 0 to 1). Such substitution strategy leads to a unique evolution in crystal structure and magnetic phases that are distinct from traditional isovalent bimetallic doping, with Cu and Cr co-substitution enhancing ferromagnetic correlations and generating a weak ferromagnetic phase in intermediate compositions. This aliovalent substitution strategy offers a universal approach for tuning layered magnetism in antiferromagnetic systems, which along with the potential for light-matter interaction and high-temperature ferroelectricity, can enable multifunctional device applications.

2D magnetism↗

Emergence of Local Magnetic Moment in Ternary TaWSe 2 Single Crystal via Atomic Clustering

Ternary transition metal dichalcogenides (TMDs) provide a versatile platform to explore novel electronic and magnetic ground states via compositional substitution and local structural modulations. Using a combination of scanning tunneling microscopy and spectroscopy (STM/S), magnetic property measurements, and density functional theory (DFT) calculations, the emergence of local magnetic moments driven by the clustering of Ta atoms in ternary TaWSe 2 single crystals is analyzed. STM topography reveals triangular clusters of Ta atoms embedded within W-rich regions of TaWSe 2 . These clusters exhibit a consistent shape and an orderly arrangement throughout the surfaces. DFT calculations show that these Ta clusters induce local strain, giving rise to localized magnetic moments. The magnetic behavior is further corroborated by temperature-dependent magnetization measurements, which exhibit a magnetic anomaly at ∼50 K. In conclusion, this study offers a pathway to engineer magnetism in TMD systems with potential applications in spintronic and quantum materials.

DFT↗

Parasitic effects in superconducting quantum interference device-based radiation comb generators

We study several parasitic effects on the implementation of a Josephson radiation comb generator based on a dc superconducting quantum interference device (SQUID) driven by an external magnetic field. This system can be used as a radiation generator similarly to what is done in optics and metrology, and allows one to generate up to several hundreds of harmonics of the driving frequency. First we take into account how the assumption of a finite loop geometrical inductance and junction capacitance in each SQUID may alter the operation of the devices. Then, we estimate the effect of imperfections in the fabrication of an array of SQUIDs, which is an unavoidable source of errors in practical situations. We show that the role of the junction capacitance is, in general, negligible, whereas the geometrical inductance has a beneficial effect on the performance of the device. The errors on the areas and junction resistance asymmetries may deteriorate the performance, but their effect can be limited to a large extent by a suitable choice of fabrication parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the magnetic nanowire cross section and magnetic ordering within a suspended 3D artificial spin-ice

Artificial spin-ice systems are patterned arrays of magnetic nanoislands arranged into frustrated geometries and provide insight into the physics of ordering and emergence. The majority of these systems have been realized in two-dimensions, mainly due to the ease of fabrication, but with recent developments in advanced nanolithography, three-dimensional artificial spin ice (ASI) structures have become possible, providing a new paradigm in their study. Such artificially engineered 3D systems provide new opportunities in realizing tunable ground states, new domain wall topologies, monopole propagation, and advanced device concepts, such as magnetic racetrack memory. Direct imaging of 3DASI structures with magnetic force microscopy has thus far been key to probing the physics of these systems but is limited in both the depth of measurement and resolution, ultimately restricting measurement to the uppermost layers of the system. In this work, a method is developed to fabricate 3DASI lattices over an aperture using two-photon lithography, thermal evaporation, and oxygen plasma exposure, allowing the probe of element-specific structural and magnetic information using soft x-ray microscopy with x-ray magnetic circular dichroism (XMCD) as magnetic contrast. The suspended polymer–permalloy lattices are found to be stable under repeated soft x-ray exposure. Analysis of the x-ray absorption signal allows the complex cross section of the magnetic nanowires to be reconstructed and demonstrates a crescent-shaped geometry. Measurement of the XMCD images after the application of an in-plane field suggests a decrease in magnetic moment on the lattice surface due to oxidation, while a measurable signal is retained on sub-lattices below the surface.

36 MATERIALS SCIENCE↗