Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Automated Thermal Image Processing for Detection and Classification of Birds and Bats (FY2012 Annual Report)

Surveying wildlife at risk from offshore wind energy development is difficult and expensive. Infrared video can be used to record birds and bats that pass through the camera view, but it is also time consuming and expensive to review video and determine what was recorded. We proposed to conduct algorithm and software development to identify and to differentiate thermally detected targets of interest that would allow automated processing of thermal image data to enumerate birds, bats, and insects. During FY2012 we developed computer code within MATLAB to identify objects recorded in video and extract attribute information that describes the objects recorded. We tested the efficiency of track identification using observer-based counts of tracks within segments of sample video. We examined object attributes, modeled the effects of random variability on attributes, and produced data smoothing techniques to limit random variation within attribute data. We also began drafting and testing methodology to identify objects recorded on video. We also recorded approximately 10 hours of infrared video of various marine birds, passerine birds, and bats near the Pacific Northwest National Laboratory (PNNL) Marine Sciences Laboratory (MSL) at Sequim, Washington. A total of 6 hours of bird video was captured overlooking Sequim Bay over a series of weeks. An additional 2 hours of video of birds was also captured during two weeks overlooking Dungeness Bay within the Strait of Juan de Fuca. Bats and passerine birds (swallows) were also recorded at dusk on the MSL campus during nine evenings. An observer noted the identity of objects viewed through the camera concurrently with recording. These video files will provide the information necessary to produce and test software developed during FY2013. The annotation will also form the basis for creation of a method to reliably identify recorded objects.

Bats↗

Development of three-wavelength CCD image pyrometer used for the temperature field measurements of continuous casting billets

This paper develops an imaging based three-color pyrometer for the monitoring of temperature distribution in a continuous casting billet. A novel optical device, together with an embedded electronic system, is designed to sequentially collect a dark image and three thermal images with specified wavelengths on a same monochromatic charge-coupled-device (CCD). The three thermal images provide the basis for the determination of target temperature, while the dark image is used to online eliminate the dark noise of CCD with a differential method. This image pyrometer is not only independent of target emissivity but also overcomes the dissimilarity of measuring accuracy between the micro-sensors of CCD resulted from the non-uniformity of pixels’ intensity response and the vignetting of optical system. Furthermore, a precise two-color temperature field measuring model on the CCD pyrometer is established, based on which a self-adaptive light-integration mechanism is presented. Compared with the traditional fixed light-integration method, the measuring range of the pyrometer is greatly extended and its sensitivity in low temperature segment is improved. The test results in a steel factory demonstrate that the pyrometer is capable of meeting the requirement of surface temperature measurements about casting billets. Reliability and accuracy of measurement results are also discussed herein.

42 ENGINEERING↗

A Region-Growing Segmentation Approach to Delineating Timberline from Satellite-Derived Tree Fractional Cover Products

Timberline marks the transitions from continuous forests to sparse forests and tundra landscapes. As the spatial distribution and dynamics of timberline are closely associated with regional energy and carbon balance, mapping timberline is important to a wide range of environmental and ecological studies. However, current timberline delineation approaches remain under-developed. We proposed an automatic timberline delineation method based on a seeded region-growing segmentation technique and satellite-derived products of tree fractional cover. We applied our approach to the West Siberian Plain and Alaska treeline regions as defined by the Circumpolar Arctic Vegetation Map. The results demonstrate the effectiveness of the proposed method for the accurate delineation of the timberlines that spatially align well with very-high-resolution satellite images. Based on the delineated timberlines, we find regional-scale tree encroachment to be not as substantial as previously reported. The proposed approach can be applied to understanding climate-induced forest responses and inform forest management practices.

Circumpolar Arctic Vegetation Map↗

Imaging Parkinsonian Pathology in Substantia Nigra with MRI

Purpose of Review: The substantia nigra pars compacta (SNc) and its projection to the striatum undergo profound degeneration in Parkinson’s disease (PD). Literature on imaging PD-related changes in the nigrostriatal system using iron-sensitive and diffusion-sensitive MRI contrasts has been contentious, with both negative and positive results reported in each contrast. These incompatible findings may be due to the inaccurate placement of regions of interest for the SNc. Recent Findings: Histologically, SNc is characterized by the presence of melanized dopamine neurons, whereas the substantia nigra pars reticulata is characterized by high iron content. Despite this histology, previous studies have frequently relied upon iron-sensitive MRI contrast when segmenting the SNc. This is also problematic since recent work found iron-sensitive and neuromelanin-sensitive contrasts are largely non-overlapping in substantia nigra. Since neuromelanin-sensitive MRI contrast colocalizes with the melanized dopamine neurons of the SNc upon radiologic–histologic correlation, the use of neuromelanin-sensitive MRI will allow for accurate localization of SNc and better capture parkinsonian pathobiology than iron-sensitive MRI. Summary: This article outlines iron-sensitive and diffusion-sensitive MRI contrasts, and provides an overview of neuromelanin-sensitive MRI techniques. The application of these techniques to image parkinsonian pathobiology in substantia nigra is then reviewed, with a focus on neuromelanin-sensitive imaging methods for the accurate and reproducible study of PD-related changes in SNc. These advances may help resolve current controversies surrounding MRI investigations of substantia nigra in PD and related disorders.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

Aim: The aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF). Methods: Fifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting {sup 99m}Tc-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and {sup 18}F-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually. Results: There was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT. Conclusion: CZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic-force-microscope Study of Interlayer _Kinks_ in Individual Vortices in Underdoped Cuprate YBa2Cu3O6 x Superconductor

We use magnetic force microscopy to both image and manipulate individual vortex lines threading single crystalline YBa{sub 2}Cu{sub 3}O{sub 6.4}, a layered superconductor. We find that when we pull the top of a pinned vortex, it may not tilt smoothly. Sometimes, we observe a vortex to break into discrete segments that can be described as short stacks of pancake vortices, similar to the 'kinked' structure proposed by Benkraouda and Clem. Quantitative analysis gives an estimate of the pinning force and the coupling between the stacks. Our measurements highlight the discrete nature of stacks of pancake vortices in layered superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy

Purpose: Phantom surrogates were developed to allow multimodal [computed tomography (CT), magnetic resonance imaging (MRI), and teletherapy] and anthropomorphic tissue simulation as well as materials and methods to construct deformable organ shapes and anthropomorphic bone models. Methods: Agarose gels of variable concentrations and loadings were investigated to simulate various soft tissue types. Oils, fats, and Vaseline were investigated as surrogates for adipose tissue and bone marrow. Anthropomorphic shapes of bone and organs were realized using 3D-printing techniques based on segmentations of patient CT-scans. All materials were characterized in dual energy CT and MRI to adapt CT numbers, electron density, effective atomic number, as well as T1- and T2-relaxation times to patient and literature values. Results: Soft tissue simulation could be achieved with agarose gels in combination with a gadolinium-based contrast agent and NaF to simulate muscle, prostate, and tumor tissues. Vegetable oils were shown to be a good representation for adipose tissue in all modalities. Inner bone was realized using a mixture of Vaseline and K{sub 2}HPO{sub 4}, resulting in both a fatty bone marrow signal in MRI and inhomogeneous areas of low and high attenuation in CT. The high attenuation of outer bone was additionally adapted by applying gypsum bandages to the 3D-printed hollow bone case with values up to 1200 HU. Deformable hollow organs were manufactured using silicone. Signal loss in the MR images based on the conductivity of the gels needs to be further investigated. Conclusions: The presented surrogates and techniques allow the customized construction of multimodality, anthropomorphic, and deformable phantoms as exemplarily shown for a pelvic phantom, which is intended to study adaptive treatment scenarios in MR-guided radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Classification of breast computed tomography data

Differences in breast tissue composition are important determinants in assessing risk, identifying disease in images and following changes over time. This paper presents an algorithm for tissue classification that separates breast tissue into its three primary constituents of skin, fat and glandular tissue. We have designed and built a dedicated breast CT scanner. Fifty-five normal volunteers and patients with mammographically identified breast lesions were scanned. Breast CT voxel data were filtered using a 5 pt median filter and the image histogram was computed. A two compartment Gaussian fit of histogram data was used to provide an initial estimate of tissue compartments. After histogram analysis, data were input to region-growing algorithms and classified as to belonging to skin, fat or gland based on their value and architectural features. Once tissues were classified, a more detailed analysis of glandular tissue patterns and a more quantitative analysis of breast composition was made. Algorithm performance assessment demonstrated very good or excellent agreement between algorithm and radiologist observers in 97.7% of the segmented data. We observed that even in dense breasts the fraction of glandular tissue seldom exceeded 50%. For most individuals the composition is better characterized as being a 70% (fat)-30% (gland) composition than a 50% (fat)-50% (gland) composition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase-contrast 3D tomography of HeLa cells grown in PLLA polymer electrospun scaffolds using synchrotron X-rays

Advanced imaging is useful for understanding the three-dimensional (3D) growth of cells. X-ray tomography serves as a powerful noninvasive, nondestructive technique that can fulfill these purposes by providing information about cell growth within 3D platforms. There are a limited number of studies taking advantage of synchrotron X-rays, which provides a large field of view and suitable resolution to image cells within specific biomaterials. In this study, X-ray synchrotron radiation microtomography at Diamond Light Source and advanced image processing were used to investigate cellular infiltration of HeLa cells within poly L-lactide (PLLA) scaffolds. This study demonstrates that synchrotron X-rays using phase contrast is a useful method to understand the 3D growth of cells in PLLA electrospun scaffolds. Two different fiber diameter (2 and 4 µm) scaffolds with different pore sizes, grown over 2, 5 and 8 days in vitro , were examined for infiltration and cell connectivity. After performing visualization by segmentation of the cells from the fibers, the results clearly show deeper cell growth and higher cellular interconnectivity in the 4 µm fiber diameter scaffold. Finally, this indicates the potential for using such 3D technology to study cell–scaffold interactions for future medical use.

3D culture↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Development of Hypoxia in a Preclinical Model of Tumor Micrometastases

Purpose: Hypoxic regions have been shown to be a characteristic feature of a wide variety of human primary tumors, whereas the oxygenation status of subclinical micrometastases is in general unknown. The development of hypoxia in a xenograft model of microscopic metastases was investigated in this study. Methods and Materials: U-25-GFP human melanomas growing in dorsal window chamber preparations in BALB/c nu/nu mice were used as a preclinical model of micrometastases. Tumor blood supply time and morphologic parameters of the vascular network were determined from first-pass imaging movies and vascular maps recorded by use of 155-kDa tetramethylrhodamine isothiocyanate-labeled dextran as a vascular tracer. Tumor hypoxia was assessed from immunohistochemical preparations of the imaged tissue by use of pimonidazole as a hypoxia marker. Results: Nearly half of the tumors had developed hypoxic regions when they reached a diameter of 2 to 3 mm. Tumors with multiple hypoxic foci showed a low growth rate, low blood flow velocity, high vessel tortuosity, high vessel segment length, and high vascular density, whereas tumors with a single hypoxic region showed a high growth rate, high blood flow velocity, low vessel tortuosity, low vessel segment length, and low vascular density. The tumors with hypoxic regions did not differ from those without hypoxia in any single parameter. Conclusions: U-25-GFP xenograft models of vascularized human tumor micrometastases may develop hypoxic regions as a consequence of two distinctly different morphologic abnormalities in the vascular network: high resistance against blood flow (i.e., high vessel tortuosity and high vessel segment length) or low vascular density.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-126: An Online Replanning Method for FFF Beams Without Couch Shift

Purpose: In a situation that couch shift for patient positioning is not preferred or prohibited (e.g., MR-Linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening filter free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here we propose a new 2-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online steps. The offline step is to create a series of pre-shifted plans (PSP) obtained by a so called “warm start” optimization (starting optimization from the original plan, rather from scratch) at a series of isocenter shifts with fixed distance (e.g. 2 cm, at x,y,z = 2,0,0 ; 2,2,0 ; 0,2,0; …;− 2,0,0). The PSPs all have the same number of segments with very similar shapes, since the warm-start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated, and instantaneously fast (no optimization or dose calculation needed). The previously-developed SAM algorithm is then applied for daily deformation. We tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusion: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation requiring no additional time from the SAM process. This research was supported by Elekta inc. (Crawley, UK)

60 APPLIED LIFE SCIENCES↗

Sequence length scaling in vision transformers for scientific images on frontier

Vision Transformers (ViTs) are pivotal for foundational models in scientific imagery, including Earth science applications, due to their capability to process large sequence lengths. While transformers for text have inspired scaling sequence lengths in ViTs, adapting these for ViTs introduces unique challenges. We develop distributed sequence parallelism for ViTs, enabling them to handle up to 1M tokens. Our approach, leveraging DeepSpeed-Ulysses and Long-Sequence-Segmentation with model sharding, is the first to apply sequence parallelism in ViT training, achieving a 94% batch scaling efficiency on 2,048 AMD-MI250X GPUs. Evaluating sequence parallelism in ViTs, particularly in models up to 10B parameters, highlighted substantial bottlenecks. We countered these with hybrid sequence, pipeline, and flash attention strategies, to scale beyond single GPU memory limits. Our method significantly enhances climate modeling accuracy by 20% in temperature predictions, marking the first training of a vision transformer model to convergence with a sequence length of 188K tokens, using full self-attention.

Tsaris, Aristeidis (aris) [ORNL] (ORCID:0000000277↗

Microoptical compound lens

An apposition microoptical compound lens comprises a plurality of lenslets arrayed around a segment of a hollow, three-dimensional optical shell. The lenslets collect light from an object and focus the light rays onto the concentric, curved front surface of a coherent fiber bundle. The fiber bundle transports the light rays to a planar detector, forming a plurality of sub-images that can be reconstructed as a full image. The microoptical compound lens can have a small size (millimeters), wide field of view (up to 180.degree.), and adequate resolution for object recognition and tracking.

47 OTHER INSTRUMENTATION↗

The large-area hybrid-optics CLAS12 RICH: Assembling, commissioning and first data-taking

Here, the first module of a Ring Imaging Cherenkov detector has been recently installed on the CLAS12 spectrometer at the Jefferson Lab (JLab) to provide the experiment with kaon identification in the momentum range between 3 and 8 GeV/c. The detector adopts a hybrid optics solution with aerogel radiator, light planar and spherical mirrors and highly-segmented photon detectors. We report here on the assembly and installation of the RICH and we show the first preliminary results obtained during the commissioning of the detector and the first physics data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualization of Local Conductance in MoS 2 /WSe 2 Heterostructure Transistors

The vertical stacking of van der Waals (vdW) materials presents a new degree of freedom to the research of two-dimensional (2D) systems. The interlayer coupling strongly influences the band structure of the heterostructures, resulting in novel properties that can be utilized for electronic and optoelectronic applications. Based on microwave microscopy studies, we report quantitative electrical imaging on gated molybdenum disulfide (MoS 2 )/tungsten diselenide (WSe 2 ) heterostructure devices, which exhibit an intriguing antiambipolar effect in their transfer characteristics. Interestingly, in the region with significant source-drain current, electrons in the n-type MoS 2 and holes in the p-type WSe 2 segments are nearly balanced, whereas the heterostructure area is depleted of mobile charges. The spatial evolution of local conductance can be ascribed to the lateral band bending and formation of depletion regions along the line of MoS 2 -heterostructure-WSe 2 . Our work vividly illustrates the microscopic origin of novel transport behaviors, which is important for the vibrant field of vdW heterojunction research.

42 ENGINEERING↗

Sensitivity map computation in adaptive electrical capacitance volume tomography with multielectrode excitations

Electrical capacitance tomography (ECT) is a low‐cost, high‐speed imaging technique useful in many industrial settings. ECT is predicated on the knowledge of sensitivity maps between capacitance electrodes that blanket the imaging domain. The simultaneous activation of multiple electrodes can be advantageous to manipulate the resulting field distributions and capture additional spatial information for imaging purposes. However, conventional methods for sensitivity map computation in ECT are not adequate in the presence of multielectrode activation because the mutual coupling between electrodes is not properly accounted for. This coupling becomes especially critical in adaptive electrical capacitance volume tomography (AECVT) sensors, where signals from many small electrode segments are combined into synthetic electrodes. A more general approach is presented for sensitivity map computation in AECVT based on the actual posteriori (induced) charge distributions rather than the conventional approach based on boundary conditions with no account for electrode interactions.

Zeeshan, Z.↗