SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

60 APPLIED LIFE SCIENCES↗

SU-E-T-747: The Use of the EQD2 Formalism and Repair Estimates in the Re-Irradiation Setting and Correlation with Patient Follow-Up Data

Purpose: Medical advances have resulted in cancer patients living longer as evidenced by the number of patients seen for possible re-irradiation. Original normal tissue dose volume constraints remain in the re-irradiation setting to minimize normal tissue toxicity. This work correlates estimates of equivalent dose and repair with sequelae. Methods: CNS and GI tract re-irradiation patient follow-up records (including imaging studies) were reviewed with side effects correlated with the calculated EQD2 and repair estimates. Results: Follow-up records for 16 re-irradiation patients with potential overlap to the spinal cord were analyzed. The mean time interval between 1st and last courses was 76.6 months. Three patients underwent a 3rd course of radiotherapy with a mean time interval between 2nd and final courses of 19.7 months. The mean values for assumed repair were 18.8% and 8.3%, respectively. The calculated total EQD2 doses were 48.09Gy and 50.98Gy with and without repair. At a mean follow-up time of 5.0 months, 6 patients were deceased and no records indicate radiation related neurological deficits. The records for 11 patients with potential overlap to the bowel were also analyzed. The mean time interval between 1st and last courses was 105.9 months. The mean value for assumed repair was 15.9%. The calculated total EQD2 doses were 64.96Gy and 70.80Gy with and without repair. At a mean follow-up time of 4.9 months, 6 patients were deceased, one having a potential enteric fistulization of the bladder. Clinical review of the case determined that the fistula was caused by tumor progression and not a side effect of radiotherapy treatments. Conclusion: Application of the EQD2 method in the re-irradiation setting using conservative estimates of repair is presented. Adhering to accepted dose volume limits following this application is demonstrated to be safe through empirical records as limited by this small patient cohort and short follow-up.

60 APPLIED LIFE SCIENCES↗

Luminescence imaging of water during proton-beam irradiation for range estimation

Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

60 APPLIED LIFE SCIENCES↗

WE-FG-202-06: The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation

Purpose: To monitor the evolution of radiation-induced cardiac inflammation in a canine model using hybrid positron emission tomography (PET/magnetic resonance imaging (MRI). Methods: Research ethics approval was obtained for a longitudinal imaging study of 5 canines after cardiac irradiation. Animals were imaged at baseline, 3 months, 6 months, and 12 months post cardiac irradiation using a hybrid PET-MRI system (Biograph mMR, Siemens Healthcare). The imaging protocol was designed to assess changes in cardiac inflammation using {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET tracer. In order to image cardiac inflammation, the normal myocardial uptake of glucose was suppressed prior to the injection of {sup 18}F-FDG. The suppression of glycolysis was achieved through; fasting (16–21 hours prior to the start of imaging) and an intravenous injection of heparin immediately followed by a 20% lipid infusion 20 min prior to the injection of {sup 18}F-FDG. The standard uptake value (SUV) obtained from 17 myocardial regions were used to compare FDG scans. All animals received a simulation CT scan (GE Medical Systems) for radiation treatment planning. Radiation treatment plans were created using the Pinncale3 treatment planning system (Philips Radiation Oncology Systems) and designed to resemble the typical cardiac exposure during left-sided breast cancer radiotherapy. Cardiac irradiations were performed in a single fraction using a TrueBeam linear accelerator (Varian Medical Systems). Results: The delivered dose (mean ± standard error) to heart, left ventricle, and left anterior descending artery were 1.7±0.1 Gy, 2.7±0.1 Gy, and 5.5±0.3 Gy respectively. At these doses, a significant increase in {sup 18}F-FDG uptake within the entire heart relative to baseline (1.1±0.02 g/ml) uptake was observed. {sup 18}F-FDG uptake at 3 months, 6 months, and 12 months post irradiation were 1.8±0.03 g/ml, 2.4±0.06 g/ml, and 2.6±0.11 g/ml respectively. Conclusion: Low doses of limited cardiac irradiation show evidence of a persistent global inflammatory response that can be detected using {sup 18}F-FDG PET imaging. This work was supported through the Translational Breast Cancer Studentship award, funded in part by the Breast Cancer Society of Canada. Additional financial support is provided by the London Regional Cancer Program Catalyst Grant and the Thames Valley Veterinary Services.

60 APPLIED LIFE SCIENCES↗

TH-CD-201-06: Experimental Characterization of Acoustic Signals Generated in Water Following Clinical Photon and Electron Beam Irradiation

Purpose: Previous work has demonstrated the detectability of acoustic waves induced following the irradiation of high density metals with radiotherapy linac photon beams. This work demonstrates the ability to experimentally detect such acoustic signals following both photon and electron irradiation in a more radiotherapy relevant material. The relationship between induced acoustic signal properties in water and the deposited dose distribution is explored, and the feasibility of exploiting such signals for radiotherapy dosimetry is demonstrated. Methods: Acoustic waves were experimentally induced in a water tank via the thermoacoustic effect following a single pulse of photon or electron irradiation produced by a clinical linac. An immersion ultrasound transducer was used to detect these acoustic waves in water and signals were read out on an oscilloscope. Results: Peaks and troughs in the detected acoustic signals were found to correspond to the location of gradients in the deposited dose distribution following both photon and electron irradiation. Signal amplitude was linearly related to the dose per pulse deposited by photon or electron beams at the depth of detection. Flattening filter free beams induced large acoustic signals, and signal amplitude decreased with depth after the depth of maximum dose. Varying the field size resulted in a temporal shift of the acoustic signal peaks and a change in the detected signal frequency. Conclusion: Acoustic waves can be detected in a water tank following irradiation by linac photon and electron beams with basic electronics, and have characteristics related to the deposited dose distribution. The physical location of dose gradients and the amount of dose deposited can be inferred from the location and magnitude of acoustic signal peaks. Thus, the detection of induced acoustic waves could be applied to photon and electron water tank and in vivo dosimetry. This work was supported in part by CIHR grants MOP-114910 and MOP-136774. S.H. acknowledges support by the NSERC CREATE Medical Physics Research Training Network grant 432290.

60 APPLIED LIFE SCIENCES↗

X-ray diffraction study of BaTiO{sub 3} single crystals before and after fast-neutron irradiation

The neutron irradiation of ferroelectrics is efficiently used to form structural states that cannot be obtained by conventional technologies. To date, the effect of neutron irradiation on the structure and properties of BaTiO{sub 3} has been studied for only ceramic materials. We have considered the influence of fast-neutron irradiation (F = 1 × 10{sup 17} cm{sup −2}) on the structure and properties of BaTiO{sub 3} single crystals for the first time. The structural changes occurring in irradiated BaTiO{sub 3} and their correlation with the behavior of dielectric and nonlinear optical characteristics are analyzed with the aid of a specially developed method for taking into account the experimental correction to diffuse scattering. Neutron irradiation to the aforementioned dose retains the polar structure of the material and only slightly changes atomic displacements. The radiationinduced structural changes occur according to the high-temperature type to form a structure similar to the cubic modification of unirradiated BaTiO{sub 3} crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of the Cluster Structure of Amorphous Fe{sub 67}Cr{sub 18}B{sub 15} Alloy in Magnetism and in the Changing of Electron Scattering Mechanisms under the Influence of Ion (Ar{sup +}) Irradiation

The contribution of clusters of different sizes to magnetism and the switching of electron scattering mechanisms in amorphous Fe{sub 67}Cr{sub 18}B{sub 15} alloy during ion Ar{sup +} irradiation is studied. The cluster magnetism is found to be related to the presence of clusters of the following two types: large α-(Fe, Cr) clusters of size D = 150–250 Å and small (D = 40–80 Å) clusters in a random intercluster medium. The generation of small ferromagnetic and antiferromagnetic clusters during ion irradiation leads to the formation of cluster glass, which affects the electrical properties of the alloy and causes a magnetic frustration. The temperature dependence of the barrier height is shown to characterize the magnetic state of the alloy in low fields. On the whole, the temperature dependence of the order parameter is a universal characteristic of the system. The temperature dependence of resistivity of initial alloys in the temperature range 98–300 K (ρ(T) ∝ T{sup 2}) is determined by electron scattering by quantum defects, and the transition into a ferromagnetic state is revealed when the derivative ∂ρ/∂T ∝ T is analyzed. The increase in resistivity and the relation ρ ∝ T{sup 1/2} in strongly inhomogeneous samples after irradiation at a dose Φ = 1.5 × 10{sup 18} ions/cm{sup 2} are caused by weak localization effects, and the transition to a ferromagnetic state becomes obvious when the derivative ∂ρ/∂T ∝ T{sup –1/2} is considered. Irradiation by fluence Φ = 3 × 10{sup 18} ions/cm2 induces a giant (twofold) increase in the alloy density, restores the ferromagnetism of large clusters, decreases the resistivity by 37%, and restores the relation ρ(T) ∝ T{sup 2}, which results from the overlapping of the irradiation-induced small clusters when their concentration increases and from an increase in the alloy density. The overlapping of clusters lowers the barrier height and decreases the sensitivity of the alloy to an applied field. The relation ρ(T) ∝ T{sup 2} is valid for the entire temperature range T = 2–300 K because of the partial screening of the magnetic moments of large clusters by a medium having the properties of cluster glass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparative study of changes in electrical properties of silicon and silicon carbide upon proton irradiation

Rates of carrier removal from the conduction band in n-type FZ-Si and 4H-SiC irradiated with 8- and 15-MeV protons at room temperature are discussed. Calculated rates of formation of primary radiation defects (Frenkel pairs) in these materials are presented and compared with the corresponding experimental values. Protons create defects in collision cascades involving recoil atoms formed in the crystal lattice itself. The results are compared with similar data previously obtained in irradiation of n-type FZ-Si and 4H-SiC with 900-keV electrons, in which case isolated so-called close Frenkel pairs are absolutely dominant among primary radiation defects. It has been found that the E-center model adequately describing the decrease in the electrical conductivity of n-FZ-Si upon electron irradiation is inapplicable to interpretation of experimental data for proton-irradiated materials. It is suggested that a pronounced annealing of 'simple' radiation defects of the type of close Frenkel pairs occurs during irradiation at room temperature.

36 MATERIALS SCIENCE↗

Modification of the structural lattice parameters and electron spectra of n-GaAs films on sapphire on irradiation with reactor neutrons

Changes in the structural parameters of epitaxial GaN films on sapphire (n-GaN/Al{sub 2}O{sub 3}(0001)) induced by irradiation with reactor neutrons with integrated fluences up to 7.25 Multiplication-Sign 10{sup 19} fn cm{sup -2} ({phi}{sub fn}/{phi}{sub tn} Almost-Equal-To 1) and subsequent isochronal annealing at temperatures up to 1000 Degree-Sign C are studied. Measurements of the lattice parameters a and c of the irradiated n-GaN films show that the parameter c increases by 0.38% and the parameter a remains almost unchanged. From theoretical estimations, it follows that, in the irradiated n-GaN film, the elastic tensile stress along the c axis is as high as {approx}1.5 GPa, whereas the compression stress in the basal plane of the unit cell is about -0.5 GPa. The tension of the irradiated GaN film along the hexagonal axis induces a decrease in the band gap E{sub g} by 37 meV and a lowering of the charge neutrality level by 22 meV with respect to the corresponding parameters in the initial GaN film on sapphire. The parameter c changed by irradiation with reactor neutrons by {Delta}c can be recovered by annealing in the temperature range 100-1000 Degree-Sign C, with the basic stage of annealing at about 400 Degree-Sign C.

36 MATERIALS SCIENCE↗

Degradation of the Photoluminescence of ZnTPP and ZnTPP–C{sub 60} Thin Films under Gamma Irradiation

Porphyrins and their fullerene complexes are promising materials for organic photovoltaic structures. However, the stability of the properties of organic components under hard radiation is poorly studied. Here, the influence of γ irradiation with medium (about 10{sup 4} Gy) and large (10{sup 7} Gy) doses on the photoluminescence of thin structurally perfect films of both pure porphyrin ZnTPP and ZnTPP/C{sub 60} composite films in the molar ratio of 1.3: 1 is investigated. It is shown that the intensity of the electronic radiative transition (626 nm) decreases under the effect of γ irradiation, and the dose dependence is threshold. The threshold dose is ~20 kGy for the ZnTPP films. The intensity of the electron-vibrational part of the spectral dependence of the PL (670–690 nm) for both types of samples decreased at initial irradiation doses and decreases less with a further increase in the irradiation dose than for the purely electron transition. The addition of a fullerene in nanocomposite films increases the threshold dose, after which the PL of the films started to degrade, by a factor of ~2.5. Herewith, the spectral components of the PL associated with the manifestation of the radiation transition of the fullerene C{sub 60} are more stable under γ irradiation.

36 MATERIALS SCIENCE↗

Features of Defect Formation in Nanostructured Silicon under Ion Irradiation

Nanostructured silicon is irradiated by Si{sup +} and He{sup +} ions with energies of 200 and 150 keV, respectively. Destruction of the structure of irradiated samples and the accumulation of defects at different irradiation fluences are investigated by Raman scattering. It is shown that single-crystal silicon films are amorphized under irradiation at 0.7 displacements per atom. However, at 0.5 displacements per atom, porous silicon does not completely amorphize and the Raman spectra contain a weak signal of the amorphous silicon phase along with a pronounced signal of the crystalline silicon phase. The size of nanocrystals in the structure of porous silicon at different irradiation fluences is estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of Ultraviolet Irradiation on Stress–Strain Behavior of Syndiotactic 1,2-Polybutadien: The Role of Oxidation

We studied the impact of ultraviolet (UV) irradiation on stress–strain characteristics, derived from uniaxial stretching measurements, and the molecular structure (photoinduced changes) of syndiotactic 1,2-polybutadien, a polymer with thermoplastic elastomer properties. Uniaxial stretching stress–strain curves are recorded for samples subjected to UV irradiation for different times and the effects UV irradiation has on the stress–strain behavior of polymers are analyzed. Long UV irradiation is found to markedly increase the hardening of polymers: Young’s modulus and yield strength increase, while the fracture strain decreases. At the same time, we observe a sharp increase in polymer molecular weight and its considerable oxidation that particularly involves surface layers. The mechanisms of cross-linking between macromolecules and their simultaneous oxidation induced by exposure to UV light are discussed along with the role these processes play in evolution of the physical mechanical properties under UV irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural evolution of Q12{sup TM} alloy irradiated in PWRs and comparison with other Zr base alloys - 2016-0061

Based on the M5{sup R}* alloy metallurgy, the Q12{sup TM} alloy (Zr-1Nb-0.5Sn-0.1Fe) was developed by AREVA NP for structural components, with ultra-low tin addition and slightly increased iron content. The behavior of this alloy was tested under irradiation in a pressurized water reactor (PWR) and has shown improvement in irradiation creep strength and similar free growth compared with M5. This paper provides results on dimensional stability and details the microstructural evolution of the Q12 alloy under neutron irradiation in PWRs. The Q12 microstructural evolution under irradiation was studied for fast neutron fluences up to 13 X 10{sup 25} n/m{sup 2} (E>1 MeV) with analytical transmission electron microscopy observations. We focused on radiation-enhanced needle-like particles, Laves phases, and the linear density of -component loops. These results are compared with other quaternary zirconium-niobium-tin-iron alloys and with M5. All these results allow a general discussion about microstructural evolution and behavior under irradiation of quaternary-type alloys compared to M5 alloy. This study, in agreement with previous works on Zr-1Nb and quaternary alloys, seems to show that increasing the iron content with the presence of niobium and tin will decrease the -component loop linear density and delay the growth breakaway. (authors)

36 MATERIALS SCIENCE↗

Irradiation of strontium chloride targets at proton energies above 35 MeV to produce PET radioisotope Y-86

Proton irradiation of natural and enriched SrCl{sub 2} targets was used to produce PET radioisotope {sup 86}. The proton energy was degraded from the incident 117.8 MeV to induce the {sup 88}Sr(p,3n) reaction. For the irradiation three pellets made of {sup nat}SrCl{sub 2} (6.61 and 74.49 g) and {sup 88}SrCl{sub 2} (5.02 g) were pressed and individually encapsulated in stainless steel target bodies. The two smaller targets were irradiated for 0.5-1 h at the energy - 46 {yields} 37 MeV to take advantage of the peak in the excitation function of the {sup 88}Sr(p,3n) reaction. The larger target was irradiated at 66.4 {yields} 44.6 MeV. The irradiated pellets were chemically processed to selectively separate {sup 86}Y radioisotope using Eichrom DGA (N,N,N{prime},N{prime}-tetra-n-octyldiglycolamide) resin. The production yields of {sup 86}Y were determined to be 10-13 mCi/{mu}A h. Coproduction of {sup 87m}Y in the final product was 34% for {sup nat}SrCl{sub 2} and 54% for {sup 88}SrCl{sub 2} target. The chemical separation yield of yttrium reached 88-92%. The developed chemical procedure allows for the same day processing and shipment of the isotope to users.

36 MATERIALS SCIENCE↗

In situ ion irradiation of amorphous TiO 2 nanotubes

Understanding of structural and morphological evolution in nanomaterials is critical in tailoring their functionality for applications such as energy conversion and storage. Here, we examine irradiation effects on the morphology and structure of amorphous TiO 2 nanotubes in comparison with their crystalline counterpart, anatase TiO 2 nanotubes, using high-resolution transmission electron microscopy (TEM), in situ ion irradiation TEM, and molecular dynamics (MD) simulations. Anatase TiO 2 nanotubes exhibit morphological and structural stability under irradiation due to their high concentration of grain boundaries and surfaces as defect sinks. On the other hand, amorphous TiO 2 nanotubes undergo irradiation-induced crystallization, with some tubes remaining only partially crystallized. The partially crystalline tubes bend due to internal stresses associated with densification during crystallization as suggested by MD calculations. Furthermore, these results present a novel irradiation-based pathway for potentially tuning structure and morphology of energy storage materials.

36 MATERIALS SCIENCE↗

FFT-based model for irradiated aggregate microstructures in concrete

The concrete biological shield of light water reactors is exposed to neutron and gamma irradiation throughout its lifetime, which results in the long-term degradation of the concrete’s mechanical properties. Under neutron irradiation, the concrete’s aggregates are subjected to radiation-induced volumetric expansion (RIVE), which strongly depends on the mineral content of the aggregate and exhibits the largest expansion in silicate-bearing minerals. In this work, the authors used the fast Fourier transform-based code Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) in 2D to model the expansion of five different aggregates provided by the Japan Concrete Aging Management Program (JCAMP). Comparable rock specimens were irradiated at the JEEP-II test reactor. The model uses realistic aggregate microstructure reconstruction based on high-resolution characterization images. The model accounts for anisotropic RIVE, thermal expansion, and the associated initiation and propagation of damage. The RIVE models are calibrated based on expansion data in the literature. The authors assume that damage occurs exclusively at interfaces between the particles that compose an aggregate and that these interfaces also exhibit swelling. Using a micromechanical model, the evolution of Young’s modulus with RIVE is calculated for each aggregate and compared with Russian irradiation data. The modeled linear expansion agrees well with the experimentally measured expansion. Furthermore, the model also predicts that anisotropic RIVE and thermal expansion result in an earlier onset of damage with neutron fluence than in the isotropic case.

36 MATERIALS SCIENCE↗

EFFECTS OF GAMMA IRRADIATION ON EPDM ELASTOMERS

Two formulations of EPDM elastomer, one substituting a UV stabilizer for the normal antioxidant in this polymer, and the other the normal formulation, were synthesized and samples of each were exposed to gamma irradiation in initially pure deuterium gas to compare their radiation stability. Stainless steel containers having rupture disks were designed for this task. After 130 MRad dose of cobalt-60 radiation in the SRNL Gamma Irradiation Facility, a significant amount of gas was created by radiolysis; however the composition indicated by mass spectroscopy indicated an unexpected increase in the total amount deuterium in both formulations. The irradiated samples retained their ductility in a bend test. No change of sample weight, dimensions, or density was observed. No change of the glass transition temperature as measured by dynamic mechanical analysis was observed, and most of the other dynamic mechanical properties remained unchanged. There appeared to be an increase in the storage modulus of the irradiated samples containing the UV stabilizer above the glass transition, which may indicate hardening of the material by radiation damage. Polymeric materials become damaged by exposure over time to ionizing radiation. Despite the limited lifetime, polymers have unique engineering material properties and polymers continue to be used in tritium handling systems. In tritium handling systems, polymers are employed mainly in joining applications such as valve sealing surfaces (eg. Stem tips, valve packing, and O-rings). Because of the continued need to employ polymers in tritium systems, over the past several years, programs at the Savannah River National Laboratory have been studying the effect of tritium on various polymers of interest. In these studies, samples of materials of interest to the SRS Tritium Facilities (ultra-high molecular weight polyethylene (UHMW-PE), polytetrafluoroethylene (PTFE, Teflon{reg_sign}), Vespel{reg_sign} polyimide, and the elastomer ethylene propylene diene monomer (EPDM)) have been exposed in closed containers to tritium gas initially at 1 atmosphere pressure. These studies have demonstrated the degradation of properties when exposed to tritium gas. Also, the radiolytic production of significant amounts of hydrogen has been observed for UHMW-PE and EPDM. The study documented in this report exposes two similar formulations of EPDM elastomer to gamma irradiation in a closed container backfilled with deuterium. Deuterium is chemically identical to protium and tritium, but allows the identification of protium that is radiolytically produced from the samples. The goal of this program is to compare and contrast the response of EPDM exposure to two different types of ionizing radiation in a similar chemical environment.

36 MATERIALS SCIENCE↗