Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Nonperturbative production of massless scalars during inflation and generation of gravitational waves

We discuss the possibility of a feature in the spectrum of inflationary gravitational waves sourced by a scalar field χ whose vacuum fluctuations are amplified by a rapidly time dependent mass. Unlike previous work which has focused on the case in which the mass of the field χ vanishes only for an instant before becoming massive again, we study a system where the scalar field becomes and remains massless through the end of inflation. After applying appropriate constraints to our parameters, we find, for future CMB experiments, a small contribution to the tensor-to-scalar ratio which can be at most of the order r ∼ 10{sup −5}. At smaller scales probed by gravitational interferometers, on the other hand, the energy density in the gravitational waves produced this way might be above the projected sensitivity of LISA, Ω{sub GW} h {sup 2} ∼ 10{sup −13}, in a narrow region of parameter space. If there is more than one χ species, then these amplitudes are enhanced by a factor equal to the number of those species.

79 ASTRONOMY AND ASTROPHYSICS↗

Calculation of the Equilibrium Evolution of the ZaP Flow $Z$ -Pinch Using a Four-Chord Interferometer

For this study, a four-chord interferometer and measurements from an array of surface-mounted magnetic probes were used in conjunction with equations of radial heat conduction and radial force balance to calculate the equilibrium evolution of a pinch plasma in the ZaP Flow Z-Pinch. A multiple shooting method was used to solve the nonlinear coupled differential equation system, with Ohmic heating and bremsstrahlung radiation as sources and sinks, respectively. Data from a single ZaP pulse are reported including profiles of magnetic field and temperature and their evolution. Profiles are dominated by high thermal conductivity near the axis which quickly decreases with radius. This is due to the plasma being weakly magnetized near the axis which increases thermal conductivity and flattens the temperature profile, but strongly magnetized near the characteristic radius, significantly reducing thermal conductivity and resulting in a large temperature gradient. The equilibrium evolution indicates that plasmas in ZaP heat and compress with increasing current as a result of magnetic compression during the quiescent period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and demonstration of tunable soft x-ray lateral shearing and Hartmann wavefront sensors

We describe design guidelines for soft x-ray wavefront sensors and experimentally demonstrate their performance, comparing grating-based lateral shearing interferometry and Hartmann wavefront sensing. We created a compact shearing interferometer concept with a dense array of binary amplitude gratings in a single membrane to support one-dimensional wavefront measurements across a wide wavelength range without the need for longitudinal position adjustment. We find that a common scaling parameter based on wavelength and the distance to the measurement plane guides the design of both systems toward optimal sensitivity. We show preliminary results from recent experiments demonstrating one and two-dimensional wavefront sensing below the Marechal criterion.

Chao, Weilun↗

Unwrapping Radiograph Target Disassembly Using Adaptive Machine Learning [Slides]

Advanced analysis methods were developed to determine the electron temperature and density evolution of targets disassembly by intense electron beams at DARHT based on shearing interferometer and shadowgraph measurements. New methods have been developed to spatially and temporally resolve electron velocity and temperature, expanding on recently published first results of Aluminum target disassembly. A surrogate model has been created for use in developing Adaptive Machine Learning analysis techniques. The results will also be used to guide the development of the system and experimental approach to future measurements on DARHT Axis-I and a new system to be deployed on DARHT Axis-II.

43 PARTICLE ACCELERATORS↗

A description of the University of Illinois meteor radar system and some first results

A recently established meteor radar system for observing motions in the upper atmosphere is described, which features a peak transmitter power of 5 megawatts. This large peak power should allow a much greater number of wind determination during a fixed period of time than other meteor radar stations. The essential features of the range algorithm, two velocity algorithms, and the interferometer phase difference algorithm in use are described. A typical measured variation in the radial southward wind as a function of time of day based on data from all altitudes is shown as an example, and some results of spectral analysis of the data, yielding amplitude and phase variation with altitude for significant waves, is discussed.

Geller, M. A.↗

Precision optical interferometry in space

POINTS, an astrometric Optical interferometer with a nominal measurement accuracy of 5 microarcseconds for the angle between a pair of stars separated by about 90 deg, is presently under consideration by two divisions of NASA-OSSA. It will be a powerful new multi-disciplinary tool for astronomical research. If chosen as the TOPS-1 (Toward Other Planetary Systems) instrument by the Solar-System Exploration Division, it will perform a definitive search for extra-solar planetary systems, either finding and characterizing a large number of them or showing that they are far less numerous than now believed. If chosen as the AIM (Astrometric Interferometry Mission) by the Astrophysics Division, POINTS will open new areas of astrophysical research and change the nature of the questions being asked in some old areas. In either case. it will be the first of a new class of powerful instruments in space and will prove the technology for the larger members of that class to follow. Based on a preliminary indication of the observational needs of the two missions, we find that a single POINTS mission will meet the science objectives of both TOPS-1 and AIM. The instrument detects dispersed fringe (channel led spectrum) and therefore can tolerate large pointing errors.

Reasenberg, Robert D.↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗

Constraining parameters of white-dwarf binaries using gravitational-wave and electromagnetic observations

The space-based gravitational wave (GW) detector, evolved Laser Interferometer Space Antenna (eLISA) is expected to observe millions of compact Galactic binaries that populate our Milky Way. GW measurements obtained from the eLISA detector are in many cases complimentary to possible electromagnetic (EM) data. In our previous papers, we have shown that the EM data can significantly enhance our knowledge of the astrophysically relevant GW parameters of Galactic binaries, such as the amplitude and inclination. This is possible due to the presence of some strong correlations between GW parameters that are measurable by both EM and GW observations, for example, the inclination and sky position. In this paper, we quantify the constraints in the physical parameters of the white-dwarf binaries, i.e., the individual masses, chirp mass, and the distance to the source that can be obtained by combining the full set of EM measurements such as the inclination, radial velocities, distances, and/or individual masses with the GW measurements. We find the following 2σ fractional uncertainties in the parameters of interest. The EM observations of distance constrain the chirp mass to ∼15%-25%, whereas EM data of a single-lined spectroscopic binary constrain the secondary mass and the distance with factors of two to ∼40%. The single-line spectroscopic data complemented with distance constrains the secondary mass to ∼25%-30%. Finally, EM data on double-lined spectroscopic binary constrain the distance to ∼30%. All of these constraints depend on the inclination and the signal strength of the binary systems. We also find that the EM information on distance and/or the radial velocity are the most useful in improving the estimate of the secondary mass, inclination, and/or distance.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of predictive performance models for supersonic gas-jet nozzles at the Laboratory for Laser Energetics

We present results characterizing the neutral-density distributions produced by the supersonic nozzles used in experiments on the OMEGA-60 and OMEGA-EP laser systems at the University of Rochester’s Laboratory for Laser Energetics (LLE). Axisymmetric Fluent® simulations using LLE nozzle specifications capture the viscous effects, gas expansion, and shock waves that complicate flow predictions for offsets above the nozzle exit. Here, these simulations show good agreement with neutral-density measurements obtained using a four-wave shearing interferometer. An analytical form is given for the plateau length. Fits to simulation data for boundary layer thickness, mean plateau density, and density ramps are given as functions of nozzle offset and nozzle backing pressure for a number of nozzles and gases.

47 OTHER INSTRUMENTATION↗

The Hawaii Imaging Fabry-Perot Interferometer (HIFI)

At Mauna Kea Observatory, researchers conducted optical, imaging spectrophotometric studies of selected active galaxies using both the Canada-France-Hawaii 3.6m and University of Hawaii 2.2m telecopes (Tully, Bland and Cecil 1988). To maximize spatial resolution, researchers select galaxies independent of luminosity but known to possess interesting morphologies or high-velocity, extranuclear ionized gas (Walker 1968; Rubin and Ford 1968). They study both the large-scale patterns produced in IR-luminous, starburst systems (e.g., M82, NGC 253, NGC 6240) and those with compact, but spatially extended, circumnuclear, narrow line regions (e.g., M51, NGC 1068, NGC 4151). Current studies are restricted to the optical (SII), (NII) and (OIII) lines and the brightest Balmer recombination lines. These lines are, in principle, sufficient to constrain the dynamical structure and dominant excitation mechanism of the ionized component.

Bland, Jonathan↗

High Resolution Imaging of Circumstellar Disks at Millimeter Wavelengths

Our program uses the techniques of millimeter interferometry to make high resolution observations of dust continuum emission to study the structure of protoplanetary disks and debris disks around nearby stars. Observations of dust emission at these wavelengths are advantageous because the dust emission is generally optically thin and directly proportional to mass, and contrast with stellar photospheres is not a problem. We are using of several observational facilities, including (1) the Very Large Array (VLA) of the National Radio Astronomy Observatories, (2) the Plateau de Bure Interferometer (PdBI) of the Institut de RadioAstronomie Millimetrique, and (3) the Submillimeter Array (SMA), now under construction by the Smithsonian Astrophysical Observatory and Academia Sinica (Taiwan). In the past year, we have accomplished the following (more details below): (1) We continued work on our 'low resolution' VLA survey of disks in Herbig Ae star and binary systems, primarily to identify candidates for higher resolution follow-up. We have submitted a paper for publication on the detailed analysis of the structure of the disk around CQ Tauri; (2) We completed analysis of our PdBI observations of the debris disk around Vega, and we presented these results at (1) the 199th AAS meeting in Washington, DC, and (2) a symposium in memory of Fred Gillett on Debris Disks and the Formation of Planets, in Tucson, AZ; (3) We continue commissioning observations with the SMA, which include the first ever interferometric images in the 850 micron wavelength band, in preparation for eventually imaging debris disks.

Wilner, David J.↗

Astrophysics to z approx. 10 with Gravitational Waves

The most useful characterization of a gravitational wave detector's performance is the accuracy with which astrophysical parameters of potential gravitational wave sources can be estimated. One of the most important source types for the Laser Interferometer Space Antenna (LISA) is inspiraling binaries of black holes. LISA can measure mass and spin to better than 1% for a wide range of masses, even out to high redshifts. The most difficult parameter to estimate accurately is almost always luminosity distance. Nonetheless, LISA can measure luminosity distance of intermediate-mass black hole binary systems (total mass approx.10(exp 4) solar mass) out to z approx.10 with distance accuracies approaching 25% in many cases. With this performance, LISA will be able to follow the merger history of black holes from the earliest mergers of proto-galaxies to the present. LISA's performance as a function of mass from 1 to 10(exp 7) solar mass and of redshift out to z approx. 30 will be described. The re-formulation of LISA's science requirements based on an instrument sensitivity model and parameter estimation will be described.

Stebbins, Robin↗

ORION S-band data acquisition for S-Y calibration

Error sources in the Operational Radio Interferometry Observing Network (ORION) are addressed. Specifically, the performance of the S-band receiver and the optimum allocation of data volume between S- and X-band observations is studied. It is found that the requirements on the S-band receiver are not very stringent. The system temperature of the ORION S-band receiver has a very small effect on baseline determination accuracy. It is unwise to pay a high cost for an S-band receiver with a low system temperature; a system temperature as high as 240 K is tolerable. Only 20 to 40 percent of data volume is to be allocated to S-band observations for minimum baseline error. The error remains low over a rather wide range of data volume ratio. Hence precise allocation of the 14 pairs of the Mark 3 very long base interferometer data channels between S- and X-band observations is not critical.

Wu, S. C.↗

Wavefront sensing, control, and pointing

A majority of future NASA astrophysics missions from orbiting interferometers to 16-m telescopes on the Moon have, as a common requirement, the need to bring light from a large entrance aperture to the focal plane in a way that preserves the spatial coherence properties of the starlight. Only by preserving the phase of the incoming wavefront, can many scientific observations be made, observations that range from measuring the red shift of quasi-stellar objects (QSO's) to detecting the IR emission of a planet in orbit around another star. New technologies for wavefront sensing, control, and pointing hold the key to advancing our observatories of the future from those already launched or currently under development. As the size of the optical system increases, either to increase the sensitivity or angular resolution of the instrument, traditional technologies for maintaining optical wavefront accuracy become prohibitively expensive or completely impractical. For space-based instruments, the low mass requirement and the large temperature excursions further challenge existing technologies. The Hubble Space Telescope (HST) is probably the last large space telescope to rely on passive means to keep its primary optics stable and the optical system aligned. One needs only look to the significant developments in wavefront sensing, control, and pointing that have occurred over the past several years to appreciate the potential of this technology for transforming the capability of future space observatories. Future developments in space-borne telescopes will be based in part on developments in ground-based systems. Telescopes with rigid primary mirrors much larger than 5 m in diameter are impractical because of gravity loading. New technologies are now being introduced, such as active optics, that address the scale problem and that allow very large telescopes to be built. One approach is a segmented design such as that being pioneered by the W.M. Keck telescope now under construction at the Mauna Kea Observatory. It consists of 36 hexagonal mirror segments, supported on a framework structure, which are positioned by actuators located between the structure and the mirrors. The figure of the telescope is initialized by making observations of a bright star using a Shack Hartmann sensor integrated with a white light interferometer. Then, using sensed data from the mirror edges to control these actuators, the figure of the mosaic of 36 segments is maintained as if it were a rigid primary mirror. Another active optics approach is the use of a thin meniscus mirror with actuators. This technique was demonstrated on the European Southern Observatory's New Technology Telescope (NTT) and is planned for use in the Very Large Telescope (consists of four 8-m apertures), which is now entering the design phase.

Pitts, Thomas↗

Technology Development Roadmap: A Technology Development Roadmap for a Future Gravitational Wave Mission

Humankind will detect the first gravitational wave (GW) signals from the Universe in the current decade using ground-based detectors. But the richest trove of astrophysical information lies at lower frequencies in the spectrum only accessible from space. Signals are expected from merging massive black holes throughout cosmic history, from compact stellar remnants orbiting central galactic engines from thousands of close contact binary systems in the Milky Way, and possibly from exotic sources, some not yet imagined. These signals carry essential information not available from electromagnetic observations, and which can be extracted with extraordinary accuracy. For 20 years, NASA, the European Space Agency (ESA), and an international research community have put considerable effort into developing concepts and technologies for a GW mission. Both the 2000 and 2010 decadal surveys endorsed the science and mission concept of the Laser Interferometer Space Antenna (LISA). A partnership of the two agencies defined and analyzed the concept for a decade. The agencies partnered on LISA Pathfinder (LPF), and ESA-led technology demonstration mission, now preparing for a 2015 launch. Extensive technology development has been carried out on the ground. Currently, the evolved Laser Interferometer Space Antenna (eLISA) concept, a LISA-like concept with only two measurement arms, is competing for ESA's L2 opportunity. NASA's Astrophysics Division seeks to be a junior partner if eLISA is selected. If eLISA is not selected, then a LISA-like mission will be a strong contender in the 2020 decadal survey. This Technology Development Roadmap (TDR) builds on the LISA concept development, the LPF technology development, and the U.S. and European ground-based technology development. The eLISA architecture and the architecture of the Mid-sized Space-based Gravitational-wave Observatory (SGO Mid)-a competitive design with three measurement arms from the recent design study for a NASA-led mission after 2020-both use the same technologies. Further, NASA participation in an ESA-led mission would likely augment the eLISA architecture with a third arm to become the SGO Mid architecture. For these reasons, this TDR for a future GW mission applies to both designs and both programmatic paths forward. It is adaptable to the different timelines and roles for an ESA-led or a NASA-led mission, and it is adaptable to available resources. Based on a mature understanding of the interaction between technology and risk, the authors of this TDR have chosen a set of objectives that are more expansive than is usual. The objectives for this roadmap are: (1) reduce technical and development risks and costs; (2) understand and, where possible, relieve system requirements and consequences; (3) increase technical insight into critical technologies; and (4) validate the design at the subsystem level. The emphasis on these objectives, particularly the latter two, is driven by outstanding programmatic decisions, namely whether a future GW mission is ESA-led or NASA-led, and availability of resources. The relative emphasis is best understood in the context of prioritization.

Laser Interferometry Space Antenna↗

MAGIS-100 environmental characterization and noise analysis

We investigate and analyze site specific systematics for the MAGIS-100 atomic interferometry experiment at Fermi National Accelerator Laboratory. As atom interferometers move out of the laboratory environment passive and active mitigation for noise sources must be implemented. To inform the research and development of the experiment design, we measure ambient temperature, humidity, and vibrations of the installation site. We find that temperature fluctuations will necessitate enclosures for critical subsystems and a temperature controlled laser room for the laser system. We also measure and analyze the vibration spectrum above and below ground for the installation site. The seismic vibration effect of gravity gradient noise is also modeled using input from a low-noise seismometer at multiple locations and a mitigation scheme is studied using a stochastic simulation and characterized by a suppression factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Revealing the Origin of Time-Reversal Symmetry Breaking in Fe-Chalcogenide Superconductor FeTe 1 - x Se x

We report that recently evidence has emerged in the topological superconductor Fe-chalcogenide FeTe 1-x Se x for time-reversal symmetry breaking (TRSB), the nature of which has strong implications on the Majorana zero modes (MZM) discovered in this system. It remains unclear however whether the TRSB resides in the topological surface state (TSS) or in the bulk, and whether it is due to an unconventional TRSB superconducting order parameter or an intertwined order. Here by performing in superconducting FeTe 1-x Se x crystals both surface-magneto-optic-Kerr effect (SMOKE) measurements using a Sagnac interferometer and bulk magnetic susceptibility measurements, we pinpoint the TRSB to the TSS, where we also detect a Dirac gap. Further, we observe surface TRSB in non-superconducting FeTe 1-x Se x of nominally identical composition, indicating that TRSB arises from an intertwined surface ferromagnetic (FM) order. The observed surface FM bears striking similarities to the two-dimensional (2D) FM found in 2D van der Waals crystals, and is highly sensitive to the exact chemical composition, thereby providing a means for optimizing the conditions for Majorana particles that are useful for robust quantum computing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating biofilm structure using x-ray microtomography and gratings-based phase contrast

Direct examination of natural and engineered environments has revealed that the majority of microorganisms in these systems live in structured communities termed biofilms. To gain a better understanding for how biofilms function and interact with their local environment, fundamental capabilities for enhanced visualization, compositional analysis, and functional characterization of biofilms are needed. For pore-scale and community-scale analysis (100’s of nm to 10’s of microns), a variety of surface tools are available. However, understanding biofilm structure in complex three-dimensional (3-D) environments is considerably more difficult. X-ray microtomography can reveal a biofilm’s internal structure, but the obtaining sufficient contrast to image low-Z biological material against a higher-Z substrate makes detecting biofilms difficult. Here we present results imaging Shewanella oneidensis biofilms on a Hollow-fiber Membrane Biofilm Reactor (HfMBR), using the x-ray microtomography system at sector 2-BM of the Advanced Photon Source (APS), at energies ranging from 13-15.4 keV and pixel sizes of 0.7 and 1.3 μm/pixel. We examine the use of osmium (Os) as a contrast agent to enhance biofilm visibility and demonstrate that staining improves imaging of hydrated biofilms. We also present results using a Talbot interferometer to provide phase and scatter contrast information in addition to absorption. Talbot interferometry allows imaging of unstained hydrated biofilms with phase contrast, while absorption contrast primarily highlights edges and scatter contrast provides little information. However, the gratings used here limit the spatial resolution to no finer than 2 μm, which hinders the ability to detect small features. Future studies at higher resolution or higher Talbot order for greater sensitivity to density variations may improve imaging.

Environmental Molecular Sciences Laboratory↗