Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hubbard Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,545 records · Page 86

Rapidly changing high-latitude seasonality: implications for the 21st century carbon cycle in Alaska

Seasonal variations in high-latitude terrestrial carbon (C) fluxes are predominantly driven by air temperature and radiation. At present, high-latitude net C uptake is largest during the summer. Recent observations and modeling studies have demonstrated that ongoing and projected climate change will increase plant productivity, microbial respiration, and growing season lengths at high-latitudes, but impacts on high-latitude C cycle seasonality (and potential feedbacks to the climate system) remain uncertain. Here we use ecosys, a well-tested and process-rich mechanistic ecosystem model that we evaluate further in this study, to explore how climate warming under an RCP8.5 scenario will shift C cycle seasonality in Alaska throughout the 21st century. The model successfully reproduced recently reported large high-latitude C losses during the fall and winter and yet still predicts a high-latitude C sink, pointing to a resolution of the current conflict between process-model and observation-based estimates of high-latitude C balance. We find that warming will result in surprisingly large changes in net ecosystem exchange (NEE; defined as negative for uptake) seasonality, with spring net C uptake overtaking summer net C uptake by year 2100. This shift is driven by a factor of 3 relaxation of spring temperature limitation to plant productivity that results in earlier C uptake and a corresponding increase in magnitude of spring NEE from –19 to –144 gC m –2 season –1 by the end of the century. Although a similar relaxation of temperature limitation will occur in the fall, radiation limitation during those months will limit increases in C fixation. Additionally, warmer soil temperatures and increased carbon inputs from plants lead to combined fall and winter C losses (163 gC m –2 ) that are larger than summer net uptake (123 gC m –2 season –1 ) by year 2100. However, this increase in microbial activity leads to more rapid N cycling and increased plant N uptake during the fall and winter months that supports large increases in spring NPP. Due to the large increases in spring net C uptake, the high-latitude atmospheric C sink is projected to sustain throughout this century. Our analysis disentangles the effects of key environmental drivers of high-latitude seasonal C balances as climate changes over the 21st century.

54 ENVIRONMENTAL SCIENCES↗

First principles study of the electronic structure of the Ni 2 MnIn / InAs and Ti 2 MnIn / InSb interfaces

We present a first principles study of the electronic and magnetic properties of epitaxial interfaces between the Heusler compounds, Ti 2 MnIn and Ni 2 MnIn, and the III-V semiconductors, InSb and InAs, respectively. We use density functional theory (DFT) with a machine-learned Hubbard U correction determined by Bayesian optimization. Here, we evaluate these interfaces for prospective applications in Majorana-based quantum computing and spintronics. In both interfaces, states from the Heusler penetrate into the gap of the semiconductor, decaying within a few atomic layers. The magnetic interactions at the interface are weak and local in space and energy. Magnetic moments of less than 0.1 µB are induced in the two atomic layers closest to the interface. The induced spin polarization around the Fermi level of the semiconductor decays within a few atomic layers. The decisive factor for the induced spin polarization around the Fermi level of the semiconductor is the spin polarization around the Fermi level in the Heusler, rather than the overall magnetic moment. As a result, the ferrimagnetic narrow-gap semiconductor Ti 2 MnIn induces a more significant spin polarization in the InSb than the ferromagnetic metal Ni 2 MnIn induces in the InAs. This is explained by the position of the transition metal d states in the Heusler with respect to the Fermi level. Based on our results, these interfaces are unlikely to be useful for Majorana devices but could be of interest for spintronics.

36 MATERIALS SCIENCE↗

HIGH FUSION PERFORMANCE IN SUPER H-MODE EXPERIMENTS ON ALCATOR C-MOD AND DIII-D

We report that the “Super H-Mode” regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest pedestal pressure ever achieved on a tokamak (p ped ~80kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated high performance, including the highest stored energy in the present configuration of DIII-D (W~2.2-3.2MJ), while utilizing only about half of the available heating power (P heat ~7-12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, Q DT,equiv ~0.5, ever achieved on a medium scale (R<2m) tokamak. Sustained high performance operation (β N ~2.9, H 98 ~1.6) has been achieved utilizing n=3 magnetic perturbations for density and impurity control. High pedestal and global performance has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. Lastly, Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its performance goals (Q=10) at I p < 15MA, and to enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Remote sensing and geophysical characterization of a floodplain-hillslope system in the East River watershed, Colorado

This package is part of the Watershed Function SFA Data Collection and contains remote sensing data and geophysical measurements acquired at the Pumphouse hillslope-floodplain site, in the East River, Colorado. The remote sensing dataset includes: a) a WorldView-2 (WV-2) pan-sharpened multi-spectral remote sensing image, and b) LiDAR derived products. The WV-2 image was acquired on September 24th, 2015, and it is composed of eight spectral bands (coastal, blue, green, yellow, red, red edge, NIR1, and NIR2) with a spatial resolution of 0.5 m, covering an area of 750x750 m. The LiDAR products are a digital surface model (DSM), representing the top-of-canopy elevation, and a digital terrain model (DTM), representing the bare-ground elevation, at the spatial resolution of 0.5 m. Such data are extracted from the LiDAR point-cloud dataset acquired over the entire watershed on August 2015 (http://dx.doi.org/10.21952/WTR/1412542). The geophysical dataset is composed of the electrical resistivity tomography (ERT) data acquired along a 158.75 m long transect, spanning the hillslope topographical gradient with 1.25 m electrode spacing. The dataset also includes soil water content measured with a TDR system. The package provides also polygons of different vegetation communities, which were used as reference data for mapping plant community distributions. The spatial polygons are based on plant locations acquired during the field campaign of June-July 2017 using an RTK DGPS system. The reference dataset is composed by 11 vegetation classes, namely, deciduous forest, evergreen forest, riparian shrubland, sagebrush, shrubland, potentilla, frasera, lupine meadow, veratrum, bunchgrass meadow, and forb, as well as four non-vegetation classes, such as water-river, water-lake, man-made, bare area, and shadow. The vegetation classes are determined based on distinct spectral and/or structural signatures of dominant species. The package includes products derived by these datasets, such as: a) a plant height map, computed by subtracting the DTM from the DSM, and b) a plant community distribution map, obtained by using a data-fusion machine-learning-based framework that exploit the WV-2 image and plant height information.

54 ENVIRONMENTAL SCIENCES↗

Determination of confinement regime boundaries via separatrix parameters on Alcator C-Mod based on a model for interchange-drift-Alfvén turbulence

The separatrix operational space (SepOS) model (Eich and Manz 2021 Nucl. Fusion 61 086017) is shown to predict the L–H transition, the L-mode density limit, and the ideal magnetohydrodynamic ballooning limit in terms of separatrix parameters for a wide range of Alcator C-Mod plasmas. The model is tested using Thomson scattering measurements across a wide range of operating conditions on C-Mod, spanning $\overline{n}_{\mathrm{e}}$ = 0.3–5.5 $\times 10^{20}\,$m −3 , $B_{\mathrm{t}} = 2.5$–8.0 T, and $B_{\mathrm{p}}$= 0.1–1.2 T. An empirical regression for the electron pressure gradient scale length, $\lambda_{{p}_{\mathrm{e}}}$, against a turbulence control parameter, $\alpha_{\mathrm{t}}$, and the poloidal fluid gyroradius, $\rho_{\mathrm{s,p}}$, is constructed for H-modes and found to require positive exponents for both regression parameters, indicating turbulence widening of near-scrape-off layer widths at high $\alpha_{\mathrm{t}}$ and an inverse scaling with $B_{\mathrm{p}}$, consistent with results on ASDEX Upgrade. The SepOS model is also tested in the unfavorable drift direction and found to apply well to all three boundaries, including the L–H transition as long as a correction to the Reynolds energy transfer term, $\alpha_\mathrm{RS} \lt 1$ is applied. I-modes typically exist in the unfavorable drift direction for values of $\alpha_{\mathrm{t}} \lesssim 0.3$. Finally, an experiment studying the transition between the Type-I ELMy and EDA H-mode is analyzed using the same framework. It is found that a recently identified boundary $\alpha_{\mathrm{t}} = 0.55$ at excludes most EDA H-modes but that the balance of wavenumbers responsible for the L-mode density limit, namely $k_\mathrm{EM} = k_\mathrm{RBM}$, may better describe the transition on C-Mod. The ensemble of boundaries validated and explored is then applied to project regime access and limit avoidance for the SPARC primary reference discharge parameters.

ELM suppression↗

Variability in observed stable water isotopes in snowpack across a mountainous watershed in Colorado

In this study, isotopic information from 81 snowpits was collected over a 5-year period in a large, Colorado watershed. Data spans gradients in elevation, aspect, vegetation, and seasonal climate. They are combined with overlapping campaigns for water isotopes in precipitation and snowmelt, and a land-surface model for detailed estimates of snowfall and climate at sample locations. Snowfall isotopic inputs, describe the majority of δ18O snowpack variability. Aspect is a secondary control, with slightly more enriched conditions on east and north facing slopes. This is attributed to preservation of seasonally enriched snowfall and vapour loss in the early winter. Sublimation, expressed by decreases in snowpack d-excess in comparison to snowfall contributions, increases at low elevation and when seasonal temperature and solar radiation are high. At peak snow accumulation, post-depositional fractionation appears to occur in the top 25 ± 14% of the snowpack due to melt-freeze redistribution of lighter isotopes deeper into the snowpack and vapour loss to the atmosphere during intermittent periods of low relative humidity and high windspeed. Relative depth of fractionation increases when winter daytime temperatures are high and winter precipitation is low. Once isothermal, snowpack isotopic homogenization and enrichment was observed with initial snowmelt isotopically depleted in comparison to snowpack and enriching over time. The rate of δ18O increase (d-excess decrease) in snowmelt was 0.02‰ per day per 100-m elevation loss. Isotopic data suggests elevation dictates snowpack and snowmelt evolution by controlling early snow persistence (or absence), isotopic lapse rates in precipitation and the ratio of energy to snow availability. Hydrologic tracer studies using stable water isotopes in basins of large topographic relief will require adjustment for these elevational controls to properly constrain stream water sourcing from snowmelt.

54 ENVIRONMENTAL SCIENCES↗

High fusion performance in Super H-mode experiments on Alcator C-Mod and DIII-D

The ‘Super H-Mode’ regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest achieved on a tokamak (pped ~ 80 kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated strong performance, including the highest stored energy in the present configuration of DIII-D (W ~ 2.2–3.2 MJ), while utilizing only about half of the available heating power (Pheat ~ 7–12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, QDT,equiv ~ 0.5, achieved on a medium scale (R < 2 m) tokamak. Sustained high performance operation (βN ~ 2.9, H98 ~ 1.6) has been achieved utilizing n = 3 magnetic perturbations for density and impurity control. Pedestal and global confinement has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. A pair of simple performance metrics is developed to assess and compare regimes. Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its goals (Q = 10) at Ip < 15 MA, and to potentially enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature and injection water source influence microbial community structure in four Alaskan North Slope hydrocarbon reservoirs

A fundamental knowledge of microbial community structure in petroleum reservoirs can improve predictive modeling of these environments. We used hydrocarbon profiles, stable isotopes, and high-density DNA microarray analysis to characterize microbial communities in produced water from four Alaskan North Slope hydrocarbon reservoirs. Produced fluids from Schrader Bluff (24–27°C), Kuparuk (47–70°C), Sag River (80°C), and Ivishak (80–83°C) reservoirs were collected, with paired soured/non-soured wells sampled from Kuparuk and Ivishak. Chemical and stable isotope data suggested Schrader Bluff had substantial biogenic methane, whereas methane was mostly thermogenic in deeper reservoirs. Acetoclastic methanogens (Methanosaeta) were most prominent in Schrader Bluff samples, and the combined δD and δ 13 C values of methane also indicated acetoclastic methanogenesis could be a primary route for biogenic methane. Conversely, hydrogenotrophic methanogens (e.g., Methanobacteriaceae) and sulfide-producing Archaeoglobus and Thermococcus were more prominent in Kuparuk samples. Sulfide-producing microbes were detected in all reservoirs, uncoupled from souring status (e.g., the non-soured Kuparuk samples had higher relative abundances of many sulfate-reducers compared to the soured sample, suggesting sulfate-reducers may be living fermentatively/syntrophically when sulfate is limited). Sulfate abundance via long-term seawater injection resulted in greater relative abundances of Desulfonauticus, Desulfomicrobium, and Desulfuromonas in the soured Ivishak well compared to the non-soured well. In the non-soured Ivishak sample, several taxa affiliated with Thermoanaerobacter and Halomonas predominated. Archaea were not detected in the deepest reservoirs. Functional group taxa differed in relative abundance among reservoirs, likely reflecting differing thermal and/or geochemical influences.

59 BASIC BIOLOGICAL SCIENCES↗

Climate, food and humans predict communities of mammals in the United States

Abstract Aim The assembly of species into communities and ecoregions is the result of interacting factors that affect plant and animal distribution and abundance at biogeographic scales. Here, we empirically derive ecoregions for mammals to test whether human disturbance has become more important than climate and habitat resources in structuring communities. Location Conterminous United States. Time Period 2010–2021. Major Taxa Studied Twenty‐five species of mammals. Methods We analysed data from 25 mammal species recorded by camera traps at 6645 locations across the conterminous United States in a joint modelling framework to estimate relative abundance of each species. We then used a clustering analysis to describe 8 broad and 16 narrow mammal communities. Results Climate was the most important predictor of mammal abundance overall, while human population density and agriculture were less important, with mixed effects across species. Seed production by forests also predicted mammal abundance, especially hard‐mast tree species. The mammal community maps are similar to those of plants, with an east–west split driven by different dominant species of deer and squirrels. Communities vary along gradients of temperature in the east and precipitation in the west. Most fine‐scale mammal community boundaries aligned with established plant ecoregions and were distinguished by the presence of regional specialists or shifts in relative abundance of widespread species. Maps of potential ecosystem services provided by these communities suggest high herbivory in the Rocky Mountains and eastern forests, high invertebrate predation in the subtropical south and greater predation pressure on large vertebrates in the west. Main Conclusions Our results highlight the importance of climate to modern mammals and suggest that climate change will have strong impacts on these communities. Our new empirical approach to recognizing ecoregions has potential to be applied to expanded communities of mammals or other taxa.

Kays, Roland↗

Neutron Diffraction Residual Strain Tensor Measurements Within The Phase IA Weld Mock-up Plate P-5

Oak Ridge National Laboratory (ORNL) has worked with NRC and EPRI to apply neutron and X-ray diffraction methods to characterize the residual stresses in a number of dissimilar metal weld mockups and samples. The design of the Phase IA specimens aimed to enable stress measurements by several methods and computational modeling of the weld residual stresses. The partial groove in the 304L stainless steel plate was filled with weld beads of Alloy 82. A summary of the weld conditions for each plate is provided in Table 1. The plates were constrained along the long edges during and after welding by bolts with spring-loaded washers attached to the 1-inch thick Al backing plate. The purpose was to avoid stress relief due to bending of the welded stainless steel plate. The neutron diffraction method was one of the methods selected by EPRI for non-destructive through thickness strain and stress measurement. Four different plates (P-3 to P-6) were studied by neutron diffraction strain mapping, representing four different welding conditions. Through thickness neutron diffraction strain mappings at NRSF2 for the four plates and associated strain-free d-zero specimens involved measurement along seven lines across the weld and at six to seven depths. The mountings of each plate for neutron diffraction measurements were such that the diffraction vector was parallel to each of the three primary orthogonal directions of the plate: two in-plane directions, longitudinal and transverse, and the direction normal to the plate (shown in left figure within Table 1). From the three orthogonal strains for each location, the residual stresses along the three plate directions were calculated. The principal axes of the strain and stress tensors, however, need not necessarily align with the plate coordinate system. To explore this, plate P-5 was selected for examination of the possibility that the principal axes of strain are not along the sample coordinate system axes. If adequate data could be collected the goal would be to determine the strain tensor's orientation and magnitude of strain along each principle axis direction.

36 MATERIALS SCIENCE↗

Quantification of Arctic Soil and Permafrost Properties Using Ground-Penetrating Radar and Electrical Resistivity Tomography Datasets

Improving understanding of Arctic ecosystem climate feedback and parameterization of models that simulate freeze-Thaw dynamics require advances in quantifying soil and snow properties. Due to the significant spatiotemporal variability of soil properties and the limited information provided by point-scale measurements (e.g., cores), geophysical methods hold potential for improving soil and permafrost characterization. In this study, we evaluate the use of a ground-penetrating radar (GPR) to estimate thaw layer thickness, snow depth, and ice-wedge characteristics in an ice-wedge-dominated tundra region near Barrow, AK, USA. To this end, we analyze GPR and point-scale measurements collected along several parallel transects at the end of the growing season and the end of frozen season. In addition, we compare the structural information extracted from the GPR data with electrical resistivity tomography (ERT) information about ice-wedge characteristics. Our study generally highlights the value of GPR data collected in the frozen season, when conditions lead to the improved GPR signal-To-noise ratio, facilitate data acquisition, and reduce acquisition-related ecosystem disturbance relative to growing season. We document for the first time that GPR data collected during the frozen season can provide reliable estimates of active layer thickness and geometry of ice wedges. We find that the ice-wedge geometry extracted from GPR data collected during the frozen season is consistent with ERT data, and that GPR data can be used to constrain the ERT inversion. Consistent with recent studies, we also find that GPR data collected during the frozen season can provide good estimates of snow thickness, and that GPR data collected during the growing season can provide reliable estimate thaw depth. As a result, our quantification of the value of the GPR and ERT data collected during growing and frozen seasons paves the way for coupled inversion of the datasets to improve understanding of permafrost variability.

54 ENVIRONMENTAL SCIENCES↗

Formation of Aerosol Nanoparticles by Gas-Phase Hydrolysis Reaction of Uranium Hexafluoride

The aerosol physics of uranyl particle formation has been addressed in this research using advanced aerosol instrumentation and an aerosol dynamics model. Based on the research works, we conclude that the formation and growth of aerosol particles by gas-phase UF6 hydrolysis strongly depends on the availability of water molecules in our reactor conditions. The total number concentration of the UO 2 F 2 particulate material that could be produced in the hydrolysis reaction is also regulated primarily by the availability of water molecule concentration. The higher the water molecule concentration, the higher the number and the larger the size of UO 2 F 2 aerosol particles that could be produced in a reactor custom-built at ORNL. Although the aerosol reactor was enabling the study of particle formation kinetics, the instrumentation was still insufficient in characterizing the chemical composition of the produced particles as well as the time-dependent evolution of the particulate species. The temporal evolution could impact the eventual fate of the particles upon release to the environment (i.e., the physio-chemical transformation, transport, and removal). On uranyl particle formation kinetics, we found that the growth rates of aerosol particles appeared to approach a single number in the range of 0.05 ± 0.03 - 0.08 ± 0.04 nm/s, statistically, as the ω value becomes smaller than 1. The size of primary particles from the UF6 hydrolysis at water-deprived condition was estimated to be 3.6 ± 0.4 nm; the higher the availability of water molecules, the larger the primary particles. The ability to precisely control the availability of water molecules in the reaction could lead to the production of nearly monodispersed aerosol particles. In other words, the result suggests that one can precisely manipulate the size of UO 2 F 2 aerosol particles by controlling the water vapor availability and interaction of water molecules with U F6 in the reaction. This finding has significant implications in the engineering manufacturing of fuel powder materials and possibly to future development and deployment of an environmental sampling apparatus.

74 ATOMIC AND MOLECULAR PHYSICS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selective triplet exciton formation in a single molecule

The formation of excitons in organic molecules by charge injection is an essential process in organic light-emitting diodes (OLEDs). According to a simple model based on spin statistics, the injected charges form spin-singlet (S1) excitons and spin-triplet (T 1 ) excitons in a 1:3 ratio. After the first report of a highly efficient OLED based on phosphorescence, which is produced by the decay of T 1 excitons, more effective use of these excitons has been the primary strategy for increasing the energy efficiency of OLEDs. Another route to improving OLED energy efficiency is reduction of the operating voltage. Because T 1 excitons have lower energy than S 1 excitons (owing to the exchange interaction), use of the energy difference could—in principle—enable exclusive production of T 1 excitons at low OLED operating voltages. However, a way to achieve such selective and direct formation of these excitons has not yet been established. Here we report a single-molecule investigation of electroluminescence using a scanning tunnelling microscope and demonstrate a simple method of selective formation of T 1 excitons that utilizes a charged molecule. A 3,4,9,10-perylenetetracarboxylicdianhydride (PTCDA) molecule adsorbed on a three-monolayer NaCl film atop Ag(111) shows both phosphorescence and fluorescence signals at high applied voltage. In contrast, only phosphorescence occurs at low applied voltage, indicating selective formation of T 1 excitons without creating their S 1 counterparts. The bias voltage dependence of the phosphorescence, combined with differential conductance measurements, reveals that spin-selective electron removal from a negatively charged PTCDA molecule is the dominant formation mechanism of T 1 excitons in this system, which can be explained by considering the exchange interaction in the charged molecule. Our findings show that the electron transport process accompanying exciton formation can be controlled by manipulating an electron spin inside a molecule. We anticipate that designing a device taking into account the exchange interaction could realize an OLED with a lower operating voltage.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Access to pedestal pressure relevant to burning plasmas on the high magnetic field tokamak Alcator C-Mod

Experiments on the Alcator C-Mod tokamak have utilized reactor-relevant magnetic fields to sustain substantially higher pedestal pressure than in other devices and allow close approach to the ITER H-mode baseline target pedestal pressure of 90 kPa. The EPED model, which couples the physics of transport driven by kinetic ballooning modes and MHD instabilities arising from peeling-ballooning modes, predicts the pressure profile at the onset of edge-localized modes (ELMs), and yields to lowest order a critical-βN like behavior for the pedestal: p∝Bt×Bp ( ∝Bt^2 for fixed edge q). C-Mod routinely accesses edge plasma pressure in excess of 30 kPa, often by using a high-density (ne>3×10^20 m^-3) approach to high confinement, taking advantage of a regime known as enhanced D-alpha (EDA) H-mode. In the EDA H-mode, plasma transport regulates both the pedestal profiles and the core impurity content, thus holding the pedestal stationary at just below the peeling-ballooning stability boundary. This stationary ELM-suppressed regime has approached the maximum pedestal predicted by EPED at these densities: 60 kPa. This in turn gives rise to volume-averaged core plasma pressure in excess of 0.2MPa, a world record value for a magnetic fusion device. Another approach to achieving high pressure utilizes a pedestal limited by current-driven modes at low collisionality, in which pressure increases with density and which allows access to a higher EPED solution, termed “super-H”. C-Mod experiments at reduced density (ne<2×10^20 m^-3) and strong plasma shaping (δ>0.5) accessed this regime, producing pedestals with pressures up to 80kPa (approximately 90% of the ITER target) and temperatures of nearly 2 keV. In a number of these hot H-modes, we observe strong edge instabilities at low toroidal mode number (n=1) when pedestal pressure approaches predicted values from EPED, showing that current-driven MHD modes can serve as a limit on the pedestal in a metal-walled tokamak at high pressure and low collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗