Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Exploring Plasma Heating in the Current Sheet Region in a Three-dimensional Coronal Mass Ejection Simulation

We simulate a coronal mass ejection using a three-dimensional magnetohydrodynamic code that includes coronal heating, thermal conduction, and radiative cooling in the energy equation. The magnetic flux distribution at 1 Rs is produced by a localized subsurface dipole superimposed on a global dipole field, mimicking the presence of an active region within the global corona. Transverse electric fields are applied near the polarity inversion line to introduce a transverse magnetic field, followed by the imposition of a converging flow to form and destabilize a flux rope, producing an eruption. We examine the quantities responsible for plasma heating and cooling during the eruption, including thermal conduction, radiation, adiabatic effects, coronal heating, and ohmic heating. We find that ohmic heating is an important contributor to hot temperatures in the current sheet region early in the eruption, but in the late phase, adiabatic compression plays an important role in heating the plasma there. Thermal conduction also plays an important role in the transport of thermal energy away from the current sheet region throughout the reconnection process, producing a “thermal halo” and widening the region of high temperatures. We simulate emission from solar telescopes for this eruption and find that there is evidence for emission from heated plasma above the flare loops late in the eruption, when the adiabatic heating is the dominant heating term. These results provide an explanation for hot supra-arcade plasma sheets that are often observed in X-rays and extreme ultraviolet wavelengths during the decay phase of large flares.

79 ASTRONOMY AND ASTROPHYSICS↗

Modelling the performance of the monogroove with screen heat pipe for use in the radiator of the solar dynamic power system of the NASA Space Station

A computer code to model the steady-state performance of a monogroove heat pipe for the NASA Space Station is presented, including the effects on heat pipe performance of a screen in the evaporator section which deals with transient surges in the heat input. Errors in a previous code have been corrected, and the new code adds additional loss terms in order to model several different working fluids. Good agreement with existing performance curves is obtained. From a preliminary evaluation of several of the radiator design parameters it is found that an optimum fin width could be achieved but that structural considerations limit the thickness of the fin to a value above optimum.

Evans, Austin Lewis↗

Effect of Insertion of a Heat Flux Gage into a High Temperature Cylindrical Blackbody Cavity on the Gage

Detailed transient thermal models have been developed to simulate a heat flux gage calibration process capable of generating high heat flux levels. These heat flux levels are of interest to the reciprocating and gas turbine engine industries as well as the aerospace industry. The transient models are based on existing, experimentally validated steady state models of a cylindrical blackbody calibration system. The steady state models were modified to include insertion of a heat flux gage into the hot zone of the calibration system, time-varying electrical current that passes through the resistance heated blackbody, and the resulting heating of the heat flux gage. Heat fluxes computed using detailed transient models were compared to experimental measurements. The calculated and measured transient heat fluxes agreed to within 2 percent, indicating that the models had captured the physical phenomena in the transient calibration. The predicted and measured transient heat fluxes were also compared for two different blackbody configurations. The effect of convection on the blackbody extension was evaluated and found to be a minor factor.

Abdelmessih, Amanie N.↗

Enhanced Surface Warming and Accelerated Snow Melt in the Himalayas and Tibetan Plateau Induced by Absorbing Aerosols

Numerical experiments with the NASA finite-volume general circulation model show that heating of the atmosphere by dust and black carbon can lead to widespread enhanced warming over the Tibetan Plateau (TP) and accelerated snow melt in the western TP and Himalayas. During the boreal spring, a thick aerosol layer, composed mainly of dust transported from adjacent deserts and black carbon from local emissions, builds up over the Indo-Gangetic Plain, against the foothills of the Himalaya and the TP. The aerosol layer, which extends from the surface to high elevation (approx.5 km), heats the mid-troposphere by absorbing solar radiation. The heating produces an atmospheric dynamical feedback the so-called elevated-heat-pump (EHP) effect, which increases moisture, cloudiness, and deep convection over northern India, as well as enhancing the rate of snow melt in the Himalayas and TP. The accelerated melting of snow is mostly confined to the western TP, first slowly in early April and then rapidly from early to mid-May. The snow cover remains reduced from mid-May through early June. The accelerated snow melt is accompanied by similar phases of enhanced warming of the atmosphere-land system of the TP, with the atmospheric warming leading the surface warming by several days. Surface energy balance analysis shows that the short-wave and long-wave surface radiative fluxes strongly offset each other, and are largely regulated by the changes in cloudiness and moisture over the TP. The slow melting phase in April is initiated by an effective transfer of sensible heat from a warmer atmosphere to land. The rapid melting phase in May is due to an evaporation-snow-land feedback coupled to an increase in atmospheric moisture over the TP induced by the EHP effect.

Lau, William K.↗

Comparing Velocity Profiles Along the Rod Length of a Helical Coil Steam Generator Model

A model of a specific type of tube and shell heat exchanger, the helical coil steam generator (HCSG), was designed and constructed to study multiple fluidic properties that attribute to the efficiency of the heat transfer it provides. Tube and shell heat exchangers are currently used throughout industry in chemical, power and petroleum engineering. Most commonly, a primary flow is circulated through a shell, while the secondary flow is run through several small tubes that are bundled together. Methods to increase the heat transfer between the two flows include adding baffles to force shell side flow over more tubes, fins added in-between layers of tubes and passing tubes multiple times through the shell to increase heat exchanger effectiveness. The HCSG incorporates many of the proposed methods but also relies on a complex geometry to increase the heat transfer between tube and shell side flow. In an area where cost effectiveness is favorable, such as inside a nuclear reactor, helically banked steam generators makes extensive use of the room with no sharp tube bends. This increases the pressure loss on the secondary flow and can solve potential temperature manufacturing issues at the welds of junctions. Additionally, they have exhibited pure cross flow behaviors with high heat transfer coefficients and axial temperature profiles that correspond to pure counter-flow with high mean temperature differences. Early work showed that helical banks can have a significant increase of 16 to 43% higher heat transfer coefficient than straight pipe heat exchangers. While many previous studies have looked at the heat transfer, pressure drop and flow fields of a tube and shell heat exchanger, they all focus on tube bundles that are either in-line or staggered. The early flow visualization studies on these types of bundle arrangements reported that attached eddies were formed alternatively behind each of the rods and were occasionally dragged into the main stream of shell side flow. Later studies suggested that observable periodic vortex shedding was dependent on geometry. Experimental data taken using techniques such as laser Doppler anemometry (LDV) by Simonin and Barcouda (1986) as mentioned in Hassan (2002), hot-wire anemometry with Tsuchida (1982) and particle image velocimetry (PIV) conducted by researchers as late as 2007 have been used to characterize turbulent flow and distinguish flow field structures within in-line and staggered tube bundles. By studying these flow field structures, their contribution to fluidic properties such as heat transfer efficiency and pressure drop can be characterized effectively. Literature review lead to a design that incorporated five layers of coils wrapped around one another. The outermost and middle layers of tubes coiled at a specific pitch in a clockwise direction while the other two layers coiled counterclockwise. The proposed design incorporates a constantly changing lateral pitch ratio, a, between adjacent rods. The constructed test section isolates a single interface between two adjacent coiling rod bundles of twelve rods. Three distinct cross sectional planes along the rod bundles were looked at to study the effect of the local geometry to flow fields, Section A, B and C. Particle Image Velocimetry (PIV) frames of 896 x 848 pixels were captured at each section across a specific height. Profiles of mean velocity fields for each section are compared and discussed as possible features of the changing lateral pitch ratio.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tensile Properties of 7075-T6 and 2024-T3 Aluminum-alloy Sheet Heated at Uniform Temperature Rates Under Constant Load

Results are presented of tests to determine the effect of heating at uniform temperature rates from 0.2 degrees to 100 degrees F. per second on the tensile properties of 7075-T6 d(75s-T6) and 2024-T3 (24s-T3) aluminum-alloy sheet under constant-load conditions. Yield and rupture stresses, obtained under rapid-heating conditions, are compared with results of elevated-temperature stress-strain tests for 1/2-hour exposure. Master yield-and-rupture-stress curves based on linear temperature-rate parameter are presented. Yield and rupture stresses and temperatures may be predicted by means of master curves and the parameter.

Heimerl, George J↗

Transient Convection Due to Imposed Heat Flux: Application to Liquid-Acquisition Devices

A model problem is considered that addresses the effect of heat load from an ambient laboratory environment on the temperature rise of liquid nitrogen inside an enclosure. This model has applications to liquid acquisition devices inside the cryogenic storage tanks used to transport vapor-free propellant to the main engine. We show that heat loads from Q = 0.001 to 10 W, with corresponding Rayleigh numbers from Ra = 109 to 1013, yield a range of unsteady convective states and temperature rise in the liquid. The results show that Q = 1 to 10 W (Ra = 1012 to 1013) yield temperature distributions along the enclosure height that are similar in trend to experimental measurements. Unsteady convection, which shows selfsimilarity in its planforms, is predicted for the range of heat-load conditions. The onset of convection occurs from a free-convection-dominated base flow that becomes unstable against convective instability generated at the bottom of the enclosure while the top of the enclosure is convectively stable. A number of modes are generated with small-scale thermals at the bottom of the enclosure in which the flow selforganizes into two symmetric modes prior to the onset of the propagation of the instability. These symmetric vertical modes transition to asymmetric modes that propagate as a traveling-wave-type motion of convective modes and are representative of the asymptotic convective state of the flow field. Intense vorticity production is created in the core of the flow field due to the fact that there is shear instability between the vertical and horizontal modes. For the higher Rayleigh numbers, 1012 to 1013, there is a transition from a stationary to a nonstationary response time signal of the flow and temperature fields with a mean value that increases with time over various time bands and regions of the enclosure.

Duval, Walter M. B.↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Investigation of Body Force Effects on Flow Boiling Critical Heat Flux

The bubble coalescence and interfacial instabilities that are important to modeling critical heat flux (CHF) in reduced-gravity systems can be sensitive to even minute body forces. Understanding these complex phenomena is vital to the design and safe implementation of two-phase thermal management loops proposed for space and planetary-based thermal systems. While reduced gravity conditions cannot be accurately simulated in 1g ground-based experiments, such experiments can help isolate the effects of the various forces (body force, surface tension force and inertia) which influence flow boiling CHF. In this project, the effects of the component of body force perpendicular to a heated wall were examined by conducting 1g flow boiling experiments at different orientations. FC-72 liquid was boiled along one wall of a transparent rectangular flow channel that permitted photographic study of the vapor-liquid interface at conditions approaching CHF. High-speed video imaging was employed to capture dominant CHF mechanisms. Six different CHF regimes were identified: Wavy Vapor Layer, Pool Boiling, Stratification, Vapor Counterflow, Vapor Stagnation, and Separated Concurrent Vapor Flow. CHF showed great sensitivity to orientation for flow velocities below 0.2 m/s, where very small CHF values where measured, especially with downflow and downward-facing heated wall orientations. High flow velocities dampened the effects of orientation considerably. Figure I shows representative images for the different CHF regimes. The Wavy Vapor Layer regime was dominant for all high velocities and most orientations, while all other regimes were encountered at low velocities, in the downflow and/or downward-facing heated wall orientations. The Interfacial Lift-off model was modified to predict the effects of orientation on CHF for the dominant Wavy Vapor Layer regime. The photographic study captured a fairly continuous wavy vapor layer travelling along the heated wall while permitting liquid contact only in wetting fronts, located in the troughs of the interfacial waves. CHF commenced when wetting fronts near the outlet were lifted off the wall. The Interfacial Lift-off model is shown to be an effective tool for predicting the effects of body force on CHF at high velocities.

Zhang, Hui↗

A general method for the analysis of compact multifluid heat exchangers.

An analytical method of treating the complex heat-transfer processes involved in compact multifluid heat exchangers is described. The method is based on representing the heat transfer by means of the analogy between heat-transfer paths and electrical circuits. For plate-fin configurations, it includes the effects of heat exchange among nonadjacent fluids due to conduction through the fins of intervening passages. The application of the developed solution procedures to the design and analysis of multifluid heat exchangers is also discussed. Results obtained in using the electrical-analog method to examine the effects of conduction on performance are presented graphically in parametric form for a number of three-fluid plate-fin configurations. The discussion of the data presented includes a comparison with results given by alternative analytical procedures which neglect direct transfer between nonadjacent fluids.

Demetri, E. P.↗

Hotter droughts alter resource allocation to chemical defenses in piñon pine

Abstract Heat and drought affect plant chemical defenses and thereby plant susceptibility to pests and pathogens. Monoterpenes are of particular importance for conifers as they play critical roles in defense against bark beetles. To date, work seeking to understand the impacts of heat and drought on monoterpenes has primarily focused on young potted seedlings, leaving it unclear how older age classes that are more vulnerable to bark beetles might respond to stress. Furthermore, we lack a clear picture of what carbon resources might be prioritized to support monoterpene synthesis under drought stress. To address this, we measured needle and woody tissue monoterpene concentrations and physiological variables simultaneously from mature piñon pines ( Pinus edulis ) from a unique temperature and drought manipulation field experiment. While heat had no effect on total monoterpene concentrations, trees under combined heat and drought stress exhibited ~ 85% and 35% increases in needle and woody tissue, respectively, over multiple years. Plant physiological variables like maximum photosynthesis each explained less than 10% of the variation in total monoterpenes for both tissue types while starch and glucose + fructose measured 1-month prior explained ~ 45% and 60% of the variation in woody tissue total monoterpene concentrations. Although total monoterpenes increased under combined stress, some key monoterpenes with known roles in bark beetle ecology decreased. These shifts may make trees more favorable for bark beetle attack rather than well defended, which one might conclude if only considering total monoterpene concentrations. Our results point to cumulative and synergistic effects of heat and drought that may reprioritize carbon allocation of specific non-structural carbohydrates toward defense.

59 BASIC BIOLOGICAL SCIENCES↗

The effect of powder feedstock and heat treatment on the thermal and mechanical properties of binder jet printed ZrC

In this study, zirconium carbide (ZrC) disks were fabricated using binder jet printing to study the effect of powder feedstock, print parameters, and heat treatment on flowability and final materials properties. A median volumetric particle size smaller than 10 μm was shown to cause the powder to stop flowing during printing. Disks were printed using ZrC with suitable flowability and then heat-treated at temperatures between 1800°C and 2200°C for 1 or 5h. The density, part shrinkage, thermal diffusivity, and fracture strength all increased with increasing temperature and time. The heat-treated disks were then heated to 2200°C for 5h and the properties converged for disks of the same particle size, indicating the hottest temperature and longest time of exposure dictates the final properties. Lastly, it was shown that larger particles produce lower density materials with worse thermal diffusivity, most likely because of poor connectivity between particles after heat treatment.

36 MATERIALS SCIENCE↗

Conditionally averaged balance equations for modeling premixed turbulent combustion in flamelet regime

Balance equations for mass, velocity, and Reynolds stresses conditioned either to an unburned or to a burned mixture are derived from standard mass conservation, Navier-Stokes, and combustion progress variable balance equations by assuming that the probability of finding intermediate states of a reacting mixture is much less than unity. The derived equations contain three unclosed terms controlled by flamelet structure and flamelet statistics, whereas other unclosed terms are not straightforwardly affected by heat release and have counterparts in models of nonreacting flows. Equations of this type offer an opportunity to facilitate modeling the effects of heat release on turbulence. The modeling of these effects is further simplified if flamelet structure perturbations by turbulent eddies are neglected. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of non-equilibrium flow chemistry and surface catalysis on surface heating to AFE

The effect of nonequilibrium flow chemistry on the surface temperature distribution over the forebody heat shield on the Aeroassisted Flight Experiment (AFE) vehicle was investigated using a reacting boundary-layer code. Computations were performed by using boundary-layer-edge properties determined from global iterations between the boundary-layer code and flow field solutions from a viscous shock layer (VSL) and a full Navier-Stokes solution. Surface temperature distribution over the AFE heat shield was calculated for two flight conditions during a nominal AFE trajectory. This study indicates that the surface temperature distribution is sensitive to the nonequilibrium chemistry in the shock layer. Heating distributions over the AFE forebody calculated using nonequilibrium edge properties were similar to values calculated using the VSL program.

Stewart, David A.↗

Diagnostics of electron-heated solar flare models. III - Effects of tapered loop geometry and preheating

A series of hydrodynamic numerical simulations of nonthermal electron-heated solar flare atmospheres and their corresponding soft X-ray Ca XIX emission-line profiles, under the conditions of tapered flare loop geometry and/or a preheated atmosphere, is presented. The degree of tapering is parameterized by the magnetic mirror ratio, while the preheated atmosphere is parameterized by the initial upper chromospheric pressure. In a tapered flare loop, it is found that the upward motion of evaporated material is faster compared with the case where the flare loop is uniform. This is due to the diverging nozzle seen by the upflowing material. In the case where the flare atmosphere is preheated and the flare geometry is uniform, the response of the atmosphere to the electron collisional heating is slow. The upward velocity of the hydrodynamic gas is reduced due not only to the large coronal column depth, but also to the increased inertia of the overlying material. It is concluded that the only possible electron-heated scenario in which the predicted Ca XIX line profiles agree with the BCS observations is when the impulsive flare starts in a preheated dense corona.

Emslie, A. G.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Evolution of TiS and TiN in Fe-40 MassPctNi Austenitic Alloy During Heating at 1273 K (1000 °C)

Evolution of TiS in composition and morphology as well as the change in size distribution of TiS and TiN in Fe-40 masspctNi austenitic alloy during heating at 1273 K (1000 °C) was investigated using manual/automatic scanning electron microscopy energy-dispersive X-ray spectroscopy (SEM/EDS). Two types of TiS morphologies, spindle and spherical, were maintained during heating. The molar ratio of Ti/S of TiS increased while the aspect ratio of TiS was maintained in both alloys during heating. The number density of TiN inclusions was low compared with TiS in each alloy during heating. The pinning effect of TiS during heating was confirmed, and was stronger in alloy with a larger volume fraction of TiS. The results contribute to the establishment of optimum heat treatment processes for austenitic stainless steel to obtain better pitting corrosion resistance.

36 MATERIALS SCIENCE↗