Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “H- source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source

Purpose: Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments, {sup 137}Cs sources have been used for several decades. A new {sup 137}Cs source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The goal of the present work is to implement the TG-43 U1 protocol in the characterization of the aforementioned {sup 137}Cs source. Methods: The dosimetric characteristics of the IPL {sup 137}Cs source are measured using LiF thermoluminescent dosimeters in a Solid Water phantom material and calculated using Monte Carlo simulations with the GEANT4 code in Solid Water and liquid water. The dose rate constant, radial dose function, and two-dimensional anisotropy function of this source model were obtained following the TG-43 U1 recommendations. In addition, the primary and scatter dose separation (PSS) formalism that could be used in convolution/superposition methods to calculate dose distributions around brachytherapy sources in heterogeneous media was studied. Results: The measured and calculated dose rate constants of the IPL {sup 137}Cs source in Solid Water were found to be 0.930({+-}7.3%) and 0.928({+-}2.6%) cGy h{sup -1} U{sup -1}, respectively. The agreement between these two methods was within our experimental uncertainties. The Monte Carlo calculated value in liquid water of the dose rate constant was {Lambda}=0.948({+-}2.6%) cGy h{sup -1} U{sup -1}. Similarly, the agreement between measured and calculated radial dose functions and the anisotropy functions was found to be within {+-}5%. In addition, the tabulated data that are required to characterize the source using the PSS formalism were derived. Conclusions: In this article the complete dosimetry of the newly designed {sup 137}Cs IPL source following the AAPM TG-43 U1 dosimetric protocol and the PSS formalism is provided.

07 ISOTOPE AND RADIATION SOURCES↗

Reduction of beam current noise in the FNAL magnetron ion source

The new FNAL Injector Line with a circular dimple magnetron ion source has been operational since December of 2012. Since the new injector came on line there have been variations in the H- beam current flattop observed near the downstream end of the Linac. Several different cathode geometries including a hollow cathode suggested by Dudnikov [1] were tried. Previous studies also showed that different mixtures of hydrogen and nitrogen had an effect on beam current noise [2]. We expanded on those studies by trying mixtures ranging from (0.25% nitrogen, 99.75% hydrogen) to (3% nitrogen, 97% hydrogen). The results of these studies in our test stand will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Compact deuterium-tritium neutron generator using a novel field ionization source

Active interrogation using neutrons is an effective method for detecting shielded nuclear material. A lightweight, lunch-box-sized, battery-operated neutron source would enable new concepts of operation in the field. We have developed at-scale components for a highly portable, completely self-contained, pulsed Deuterium-Tritium (DT) neutron source producing 14 MeV neutrons with average yields of 10{sup 7} n/s. A gated, field ionization ion source using etched electrodes has been developed that produces pulsed ion currents up to 500 nA. A compact Cockcroft-Walton high voltage source is used to accelerate deuterons into a metal hydride target for neutron production. The results of full scale DT tests using the field ionization source are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operating single quantum emitters with a compact Stirling cryocooler

The development of an easy-to-operate light source emitting single photons has become a major driving force in the emerging field of quantum information technology. Here, we report on the application of a compact and user-friendly Stirling cryocooler in the field of nanophotonics. The Stirling cryocooler is used to operate a single quantum emitter constituted of a semiconductor quantum dot (QD) at a base temperature below 30 K. Proper vibration decoupling of the cryocooler and its surrounding enables free-space micro-photoluminescence spectroscopy to identify and analyze different charge-carrier states within a single quantum dot. As an exemplary application in quantum optics, we perform a Hanbury-Brown and Twiss experiment demonstrating a strong suppression of multi-photon emission events with g{sup (2)}(0) < 0.04 from this Stirling-cooled single quantum emitter under continuous wave excitation. Comparative experiments performed on the same quantum dot in a liquid helium (LHe)-flow cryostat show almost identical values of g{sup (2)}(0) for both configurations at a given temperature. The results of this proof of principle experiment demonstrate that low-vibration Stirling cryocoolers that have so far been considered exotic to the field of nanophotonics are an attractive alternative to expensive closed-cycle cryostats or LHe-flow cryostats, which could pave the way for the development of high-quality table-top non-classical light sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HUBBLE SPACE TELESCOPE SURVEY OF H{sub 2} EMISSION IN THE CIRCUMSTELLAR ENVIRONMENTS OF YOUNG STARS

The formation timescale and final architecture of exoplanetary systems are closely related to the properties of the molecular disks from which they form. Observations of the spatial distribution and lifetime of the molecular gas at planet-forming radii (a < 10 AU) are important for understanding the formation and evolution of exoplanetary systems. Toward this end, we present the largest spectrally resolved survey of H{sub 2} emission around low-mass pre-main-sequence stars compiled to date. We use a combination of new and archival far-ultraviolet spectra from the Cosmic Origins Spectrograph and Space Telescope Imaging Spectrograph instruments on the Hubble Space Telescope to sample 34 T Tauri stars (27 actively accreting Classical T Tauri Stars and 7 non-accreting Weak-lined T Tauri Stars) with ages ranging from {approx}1 to 10 Myr. We observe fluorescent H{sub 2} emission, excited by Ly{alpha} photons, in 100% of the accreting sources, including all of the transitional disks in our sample (CS Cha, DM Tau, GM Aur, UX Tau A, LkCa 15, HD 135344B, and TW Hya). The spatial distribution of the emitting gas is inferred from spectrally resolved H{sub 2} line profiles. Some of the emitting gas is produced in outflowing material, but the majority of H{sub 2} emission appears to originate in a rotating disk. For the disk-dominated targets, the H{sub 2} emission originates predominately at a {approx}< 3 AU. The emission line widths and inner molecular radii are found to be roughly consistent with those measured from mid-IR CO spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Massive Stars in Molecular Clouds Rich in High-energy Sources: The Bridge of G332.809–0.132 and CS 78 in NGC 6334

Detections of massive stars in the direction of the H ii region CS 78 in NGC 6334 and of G332.809−0.132 are here presented. The region covered by the G332.809−0.132 complex coincides with the RCW 103 stellar association. In its core (40′ in radius), approximately 110 OB candidate stars (K {sub s} < 10 mag and 0.4 < A{sub K{sub s}} < 1.6 mag) were identified using 2MASS, DENIS, and GLIMPSE data. This number of OB stars accounts for more than 50% of the observed number of Lyman continuum photons from this region. Medium-resolution K-band spectra were obtained for seven early types, including one WN 8 star and one Ofpe/WN 9 star; the latter is located near the RCW 103 remnant and its luminosity is consistent with a distance of ≈3 kpc. The area analyzed encloses 9 of the 34 OB stars previously known in RCW 103, as well as IRAS 16115−5044, which we reclassify as a candidate luminous blue variable. The line of sight is particularly interesting, crossing three spiral arms; a molecular cloud at −50 (with RCW 103 in the Scutum-Crux arm) and another at −90 km s{sup −1} (in the Norma arm) are detected, both rich in massive stars and supernova remnants. We also report the detection of a B supergiant as the main ionizing source of CS 78, 2MASS J17213513−3532415. Medium-resolution H- and K-band spectra display H i and He i lines, as well as Fe ii lines. By assuming a distance of 1.35 kpc, we estimate a bolometric magnitude of −6.16, which is typical of supergiants.

79 ASTRONOMY AND ASTROPHYSICS↗

Front-end simulation of injector for terawatt accumulator

A terawatt accumulator (TWAC) accelerator/storage ring complex with the laser ion source is in progress at ITEP. The new injector I4 based on the radio frequency quadrupole (RFQ) and interdigital H-mode (IH) linear accelerator is under construction. The front end of the new TWAC injector consists of a laser ion source, an extraction system, and a low energy beam transport (LEBT). The KOBRA3-INP was used for the simulation and optimization of the ion source extraction system. The optimization parameter is the maximum brightness of the beam generated by the laser ion source. Also the KOBRA3-INP code was used for LEBT investigation. The LEBT based on electrostatic grid lenses is chosen for injector I4. The results of the extraction system and LEBT investigations for ion beam matching with RFQ are presented.

43 PARTICLE ACCELERATORS↗

Estimating the AmLi Neutron Spectrum from Measured Ring Ratios

These are a set of slides on estimating the AmLi neutron spectrum from measured ring ratios. The IAEA uses an AmLi source in the Uranium Neutron Coincidence Collar (UNCL) to verify compliance with nonproliferation treaties. The UNCL requires calibration with known uranium samples. The AmLi spectrum isn’t known well enough to allow simulated calibrations. Alphas lose energy traveling through AmO 2 particle of unknown size. Energy reduction below Li threshold enhances O contribution. Unknown Li matrix material affects neutron production and thermalization. There is large variation in spectra from each element. Other topics covered include: applications, physics considerations, current spectra, measurement overview, measurement results - variation between sources, simulations, spectra fitting, other simulations, and conclusions.

07 ISOTOPE AND RADIATION SOURCES↗

Using adaptive proper orthogonal decomposition to solve the reaction-diffusion equation

We introduce an adaptive POD method to reduce the computational cost of reacting flow simulations. The scheme is coupled with an operator-splitting algorithm to solve the reaction-diffusion equation. For the reaction sub-steps, locally valid basis vectors, obtained via POD and the method of snapshots, are used to project the minor species mass fractions onto a reduced dimensional space thereby decreasing the number of equations that govern combustion chemistry. The method is applied to a one-dimensional laminar premixed CH{sub 4}-air flame using GRImech 3.0; with errors less than 0:25%, a speed-up factor of 3:5 is observed. The speed-up results from fewer source term evaluations required to compute the Jacobian matrices.

99 GENERAL AND MISCELLANEOUS↗

Over 8 hours of continuous operation of a free-electron laser driven by a laser-plasma accelerator

Since the emergence of laser-plasma accelerators (LPAs), substantial work has been dedicated to using LPAs to drive free-electron lasers (FELs) for a broad range of applications. Despite recent breakthroughs, which have proven the fundamental feasibility of operating FELs with an LPA source, stable FEL operation over multiple hours without operator input had yet to be achieved. In this work, we report significant improvements to the stability of a hundred terawatt laser system, resulting in successful demonstration of reliable, long-term operation of an LPA-driven FEL in the self-amplified spontaneous emission (SASE) regime at 420 nm. The LPA source delivered 100 MeV electron beams at 1 Hz with high stability over more than 10 h, enabling over 8 h of continuous FEL operation without operator input. The acquired data were subsequently used to investigate correlations between the measured undulator radiation and parameters of the drive laser, plasma source, and electron beam. The revealed connections between LPA and FEL performance gave important additional insights into ways to further improve and stabilize the system, thus demonstrating the capability of our setup to serve as a powerful platform for future studies of LPA-driven FEL operation. The one-of-a-kind integration of multiple stabilization concepts onto the LPA facility discussed in this manuscript yielded significant accelerator and light source improvements (with residual correlations suggesting even more is possible), which will positively impact LPA applications at large.

Kohrell, Finn [Lawrence Berkeley National Laborato↗

SUZAKU VIEW OF THE SWIFT/BAT ACTIVE GALACTIC NUCLEI. I. SPECTRAL ANALYSIS OF SIX ACTIVE GALACTIC NUCLEI AND EVIDENCE FOR TWO TYPES OF OBSCURED POPULATION

We present a systematic spectral analysis with Suzaku of six active galactic nuclei (AGNs) detected in the Swift/BAT hard X-ray (15-200 keV) survey: Swift J0138.6-4001, J0255.2-0011, J0350.1-5019, J0505.7-2348, J0601.9-8636, and J1628.1-5145. This is considered to be a representative sample of new AGNs without X-ray spectral information before the BAT survey. We find that the 0.5-200 keV spectra of these sources can be uniformly fitted with a base model consisting of heavily absorbed (log N {sub H} > 23.5 cm{sup -2}) transmitted components, scattered lights, a reflection component, and an iron-K emission line. There are two distinct groups: three 'new-type' AGNs (including the two sources reported by Ueda et al.) with an extremely small scattered fraction (f {sub scat} < 0.5%) and strong reflection component (R = {omega}/2{pi} {approx}> 0.8, where {omega} is the solid angle of the reflector), and three 'classical-type' ones with f {sub scat} > 0.5% and R {approx}< 0.8. The spectral parameters suggest that the new type has an optically thick torus for Thomson scattering (N {sub H} {approx} 10{sup 25} cm{sup -2}) with a small opening angle {theta} {approx} 20 deg. viewed in a rather face-on geometry, while the classical type has a thin torus (N {sub H} {approx} 10{sup 23-24} cm{sup -2}) with {theta} {approx}> 30 deg. We infer that a significant number of new-type AGNs with an edge-on view are missing in the current all-sky hard X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of measured and modelled negative hydrogen ion densities at the ECR-discharge HOMER

As the negative hydrogen ion density n{sub H{sup −}} is a key parameter for the investigation of negative ion sources, its diagnostic quantification is essential in source development and operation as well as for fundamental research. By utilizing the photodetachment process of negative ions, generally two different diagnostic methods can be applied: via laser photodetachment, the density of negative ions is measured locally, but only relatively to the electron density. To obtain absolute densities, the electron density has to be measured additionally, which induces further uncertainties. Via cavity ring-down spectroscopy (CRDS), the absolute density of H{sup −} is measured directly, however LOS-averaged over the plasma length. At the ECR-discharge HOMER, where H{sup −} is produced in the plasma volume, laser photodetachment is applied as the standard method to measure n{sub H{sup −}}. The additional application of CRDS provides the possibility to directly obtain absolute values of n{sub H{sup −}}, thereby successfully bench-marking the laser photodetachment system as both diagnostics are in good agreement. In the investigated pressure range from 0.3 to 3 Pa, the measured negative hydrogen ion density shows a maximum at 1 to 1.5 Pa and an approximately linear response to increasing input microwave powers from 200 up to 500 W. Additionally, the volume production of negative ions is 0-dimensionally modelled by balancing H{sup −} production and destruction processes. The modelled densities are adapted to the absolute measurements of n{sub H{sup −}} via CRDS, allowing to identify collisions of H{sup −} with hydrogen atoms (associative and non-associative detachment) to be the dominant loss process of H{sup −} in the plasma volume at HOMER. Furthermore, the characteristic peak of n{sub H{sup −}} observed at 1 to 1.5 Pa is identified to be caused by a comparable behaviour of the electron density with varying pressure, as n{sub e} determines the volume production rate via dissociative electron attachment to vibrationally excited hydrogen molecules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Final design of thermal diagnostic system in SPIDER ion source

The prototype radio frequency source of the ITER heating neutral beams will be first tested in SPIDER test facility to optimize H{sup −} production, cesium dynamics, and overall plasma characteristics. Several diagnostics will allow to fully characterise the beam in terms of uniformity and divergence and the source, besides supporting a safe and controlled operation. In particular, thermal measurements will be used for beam monitoring and system protection. SPIDER will be instrumented with mineral insulated cable thermocouples, both on the grids, on other components of the beam source, and on the rear side of the beam dump water cooled elements. This paper deals with the final design and the technical specification of the thermal sensor diagnostic for SPIDER. In particular the layout of the diagnostic, together with the sensors distribution in the different components, the cables routing and the conditioning and acquisition cubicles are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast x-ray scattering of photodissociation dynamics in 2-iodothiophene

Here, a time-resolved x-ray scattering (TRXS) investigation of the photodissociation dynamics of gas-phase 2-iodothiophene molecules following 252 nm excitation is presented. Structural evolution of the molecule and dynamical information on the resulting photofragments were captured using femtosecond x-ray free-electron laser pulses. Two dissociation pathways were identified, arising via excitation to ππ* and (n/π)σ* states, respectively, yielding distinct interfragment recoil velocities of ∼6.4 Åps −1 and 17.0 Åps −1 . A comparison of asymptotic scattering data with simulated patterns indicates that the thiophene ring remains closed following dissociation at this wavelength. Modeling the experimental data yields a branching ratio of ∼3:1 in favor of the high velocity channel. These findings demonstrate the capability of TRXS to disentangle concurrent ultrafast reaction pathways and provide detailed structural insight into energy redistribution during photoinduced bond fission in complex molecular systems.

Razmus, Weronika O. [Univ. of Southampton (United ↗

SULFUR- AND SILICON-BEARING MOLECULES IN PLANETARY NEBULAE: THE CASE OF M2-48

Molecular-line observations of the bipolar planetary nebula (PN) M2-48 have been conducted using the Sub-Millimeter Telescope and the 12 m antenna of the Arizona Radio Observatory at 1, 2, and 3 mm. M2-48 is estimated to be ∼4800 yr old, midway through the PN evolutionary track. SiO and SO{sub 2} were detected in this source—the first identification of either molecule in a PN. CN, HCN, HNC, CS, SO, HCO{sup +}, N{sub 2}H{sup +}, and several {sup 13}C isotopologues such as {sup 13}CN, H{sup 13}CN, and H{sup 13}CO{sup +} were also observed toward this object. A radiative transfer analysis of multiple SiO transitions indicates a gas kinetic temperature of T {sub K} ∼ 55 K and a density of n(H{sub 2}) ∼ 9 × 10{sup 5} cm{sup –3} in M2-48, in agreement with previous CS and CO modeling. After CO, CN, and SO were found to be the most prevalent molecules in this nebula, with fractional abundances, relative to H{sub 2}, of f ∼ 3.8 × 10{sup –7} and 2.4 × 10{sup –7}, respectively. SO{sub 2} and HCN are also abundant, with f ∼ 1.2 × 10{sup –7}, indicating an [SO]/[SO{sub 2}] ratio of ∼2. Relatively high ion abundances were measured in M2-48 as well, with f ∼ 10{sup –7} for both HCO{sup +} and N{sub 2}H{sup +}. An [HCN]/[HNC] ratio of ∼2 was determined, as typically observed in other PNe, independent of age. The high abundances of SO and SO{sub 2}, along with the presence of SiO with f ∼ 2.9 × 10{sup –8}, suggest O/C > 1 in this source; furthermore, the prevalence of CN and N{sub 2}H{sup +} indicates nitrogen enrichment. The {sup 12}C/{sup 13}C ratio of ∼3 in the nebula was also established. These factors indicate hot-bottom burning occurred in the progenitor star of M2-48, suggesting an initial mass > 4 M {sub ☉}.

79 ASTRONOMY AND ASTROPHYSICS↗

The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields

Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secondary particle spectra. Further irradiations have been made in the epithermal neutron beams at the research reactors FiR 1 in Helsinki, Finland, and Tsing Hua open pool reactor in HsinChu, Taiwan ROC. Readout has been performed with electron spin resonance spectrometry with reference to an absorbed dose standard in a {sup 60}Co gamma ray beam. Absorbed doses and dose components have been calculated using the Monte Carlo codes FLUKA and MCNP. The relative effectiveness (RE), linking absorbed dose and detector response, has been calculated using the Hansen and Olsen alanine response model. Results: The measured dose response of the alanine detector in the different experiments has been evaluated and compared to model predictions. Therefore, a relative effectiveness has been calculated for each dose component, accounting for its dependence on particle type and energy. Agreement within 5% between model and measurement has been achieved for most irradiated detectors. Significant differences have been observed in response behavior between thermal and epithermal neutron fields, especially regarding dose composition and depth dose curves. The calculated dose components could be verified with the experimental results in the different primary and secondary particle fields. Conclusions: The alanine detector can be used without difficulty in neutron fields. The response has been understood with the model used which includes the relative effectiveness. Results and the corresponding discussion lead to the conclusion that application in neutron fields for medical purpose is limited by its sensitivity but that it is a useful tool as supplement to other detectors and verification of neutron source descriptions.

07 ISOTOPE AND RADIATION SOURCES↗

BATMAN beam properties characterization by the beam emission spectroscopy diagnostic

The ITER neutral beam heating systems are based on the production and acceleration of negative ions (H/D) up to 1 MV. The requirements for the beam properties are strict: a low core beam divergence (< 0.4 °) together with a low source pressure (≤ 0.3 Pa) would permit to reduce the ion losses along the beamline, keeping the stripping particle losses below 30%. However, the attainment of such beam properties is not straightforward. At IPP, the negative ion source testbed BATMAN (BAvarian Test MAchine for Negative ions) allows for deepening the knowledge of the determination of the beam properties. One of the diagnostics routinely used to this purpose is the Beam Emission Spectroscopy (BES): the H{sub α} light emitted in the beam is detected and the corresponding spectra are evaluated to estimate the beam divergence and the stripping losses. The BES number of lines of sight in BATMAN has been recently increased: five horizontal lines of sight providing a vertical profile of the beam permit to characterize the negative ion beam properties in relation to the source parameters. Different methods of H{sub α} spectra analysis are here taken into account and compared for the estimation of the beam divergence and the amount of stripping. In particular, to thoroughly study the effect of the space charge compensation on the beam divergence, an additional hydrogen injection line has been added in the tank, which allows for setting different background pressure values (one order of magnitude, from about 0.04 Pa up to the source pressure) in the beam drift region.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First measurement of the asymmetry and the Gerasimov-Drell-Hearn integrand from the 3 $\vec{H}$e ($\vec{γ},p$) 2 H reaction at an incident photon energy of 29 MeV

The first measurement of the 3 $\vec{H}$e ($\vec{γ},p$) 2 H process was performed at the High Intensity γ-ray Source ( HIγS ) facility at Triangle Universities Nuclear Laboratory using a circularly polarized, monoenergetic γ -ray beam and a longitudinally polarized 3 He target. The spin-dependent asymmetry and the contribution from the two-body photodisintegration to the 3 He Gerasimov-Drell-Hearn integrand are extracted and compared with state-of-the-art three-nucleon system calculations at the incident photon energy of 29 MeV. The data are in general agreement with the various theoretical predictions based on the Siegert theorem or on explicit inclusion of meson-exchange currents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗