Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Climate-Water Impacts on Interconnection-Scale Electricity System Planning

A growing literature emphasizes the importance of integrating climate change impacts into electricity system planning. Rising average temperatures can increase and shift electricity demand while reducing generator and transmission efficiency. Changes to water availability and quality can reduce the output of thermally cooled generators and hydropower. Electric power grids across the US and globally are undergoing transformational changes that present new opportunities and challenges to reliability assurance. However, electric utilities and system operators have limited internal capabilities to incorporate these effects into planning practices. This work addresses gaps in utility and system planner practices by integrating climate-water-electricity expertise from universities and U.S. Department of Energy National Laboratories with electricity system planners and stakeholders in the Western Electricity Coordinating Council (WECC). Using a highly collaborative approach, global climate model data, high-resolution hydrology models, and long-term electric sector capacity expansion tools are employed to analyze a range of climate outcomes for future electricity scenarios aligned with recent WECC planning studies. Doing so allows WECC to expand its climate-agnostic planning assessments to consider how future temperature and precipitation patterns could influence generation and transmission planning. We explore how changes to climate-water conditions can affect power plant investment and operation, system economics, and environmental impacts, providing an expanded perspective on interconnection-wide decision making under climate uncertainty.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A simple way to integrate distributed storage into a wholesale electricity market

Abstract Current plans to decarbonize the electric supply system imply that the generation from wind and solar sources will grow substantially. This growth will increase the uncertainty of system operations due to the inherent variability of these renewable sources, and as a result, more reserve capacity will be required to provide the ramping (flexibility) needed for reliable operations. This paper assumes that all of the increased uncertainty comes from wind farms on the grid, and it shows how distributed storage managed locally by aggregators can provide the ramping needed without introducing a separate market for flexibility. This can be accomplished when the aggregators minimize the expected daily cost of the energy purchased from the grid for their customers by submitting optimal bids into the wholesale market with high and low price thresholds for discharging and charging the storage. This model is illustrated using a stochastic multi-period security constrained optimal power flow together with realistic data for a reduction of the network in the Northeast Power Coordinating Council region of the United States. The results show that the bidding strategy for distributed storage provides ramping to the grid just as effectively as storage managed by a system operator.

Lamadrid, Alberto J.↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Thermal Energy Corporation Combined Heat and Power Project

To meet the planned heating and cooling load growth at the Texas Medical Center (TMC), Thermal Energy Corporation (TECO) implemented Phase 1 of a Master Plan to install an additional 32,000 tons of chilled water capacity, a 75,000 ton-hour (8.8 million gallon) Thermal Energy Storage (TES) tank, and a 48 MW Combined Heat and Power (CHP) system. The Department of Energy selected TMC for a $10 million grant award as part of the Financial Assistance Funding Opportunity Announcement, U.S. Department of Energy National Energy Technology, Recovery Act: Deployment of Combined Heat and Power (CHP) Systems, District Energy Systems, Waste Energy Recovery Systems, and Efficiency Industrial Equipment Funding Opportunity Number: DE-FOA-0000044 to support the installation of a new 48 MW CHP system at the TMC located just outside downtown Houston. As the largest medical center in the world, TMC is home to many of the nation's best hospitals, physicians, researchers, educational institutions, and health care providers. TMC provides care to approximately six million patients each year, and medical instruction to over 71,000 students. A medical center the size of TMC has enormous electricity and thermal energy demands to help it carry out its mission. Reliable, high-quality steam and chilled water are of utmost importance to the operations of its many facilities. For example, advanced medical equipment, laboratories, laundry facilities, space heating and cooling all rely on the generation of heat and power. As result of this project TECO provides this mission critical heating and cooling to TMC utilizing a system that is both energy-efficient and reliable since it provides the capability to run on power independent of the already strained regional electric grid. This allows the medical center to focus on its primary mission providing top quality medical care and instruction without worrying about excessive energy costs or the loss of heating and cooling due to the risk of power outages. TECO's operation is the largest Chilled Water District Energy System in the United States. The company used DOE's funding to help install a new high efficiency CHP system consisting of a Combustion Turbine and a Heat Recovery Steam Generator. This CHP installation was just part of a larger project undertaken by TECO to ensure that it can continue to meet TMC's growing needs. The complete efficiency overhaul that TECO undertook supported more than 1,000 direct and indirect jobs in manufacturing, engineering, and construction, with approximately 400 of those being jobs directly associated with construction of the combined heat and power plant. This showcase industrial scale CHP project, serving a critical component of the nation's healthcare infrastructure, directly and immediately supported the energy efficiency and job creation goals established by ARRA and DOE. It also provided an unsurpassed model of a district energy CHP application that can be replicated within other energy intensive applications in the industrial, institutional and commercial sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IRPS Increases its Coverage of SiC and GaN

Over the past few years, interest has rocketed in the use of wide bandgap devices for energy-efficiency applications such as the electric grid, vehicle electrification, and more-electric aircraft. Deployed in these situations, devices must have a high reliability. In fact, this attribute is so crucial that it is a primary gatingfactor, determining the rate at which these wide bandgap devices are being inserted into these system applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Innovative Secure mmWave M2M Communication Network for Operating Drones

Analyze RF (Radio Frequency) coverage in the sky with the innovative use of mmWave phased arrays aimed towards the drone corridor to harness the power of 5G – multiplicative improvement in data throughput & reduction in latency, and support of massive M2M communications. Apply MA (Multiple Access) technology to increase the spectral efficiency by covering a swarm of drones with a single mmWave beam and associated radio resources. Design energy efficient low-bit quantization to form mmWave beams for drone operation. Use drones’ navigation capabilities to significantly improve security by e.g. evading attackers. Utilize intra-drone communication to improve reliability as well as security. Demonstrate the simulated recovery of a critical infrastructure such as a power grid that requires a black restart with mmWave modeling and experiments .

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Managing Power Systems-Induced Wildfire Risks Using Optimal Scheduled Shutoffs

The increasing demands for electricity and the increase in extreme weather conditions are putting unprecedented pressure on our electric grids. Often, this pressure leads to electrical component failures, which might ignite wildfires. This work develops a novel model to balance the reliability of power network operations and the risk of wildfire ignition by opti- mizing the operational schedule of power transmission networks considering time-varying risk measures that include exogenous and operational factors. Energy storage systems are considered to deliver power during peak wildfire hours and enable temporal load shifting. The problem is formulated as a mixed-integer linear program that maximizes a weighted sum of the served power demand and the reduction in grid-induced wildfire risk. The results demonstrate the ability of the model to significantly reduce wildfire risk without considerable load shedding.

power systems operations↗

Spatiotemporal Variability of Electric System Reliability Metrics

As urbanization continues to grow, urban density also rises, placing significant stress on critical infrastructure. Cities often face challenges in investing in new infrastructure or upgrading existing ones. One area of infrastructure that has come under strain is the electric grid, leading to prolonged power outages. According to data from the U.S. Energy Information Administration, the average duration of power outages has steadily doubled from 2013 to 2021, primarily due to extreme weather events. The IEEE has developed a series of reliability metrics to assess the reliability of the electric system. However, these metrics are only applied at the utility level, making it challenging to comprehend the variations in these indices at finer spatial resolutions and, consequently, evaluate reliability at the non-utility level. In this study, we leveraged electric outage data collected at 15-minute intervals at the county level to estimate electric system reliability over a six-year period using a novel data analysis approach. Our findings reveal a gradual decline in reliability in the U.S. Southwest compared to national averages. Furthermore, the duration of outages per customer per event has significantly decreased in large portions of California and Florida. These discoveries can be valuable for utility companies as they seek to pinpoint regional anomalies and plan for prioritized remediation efforts.

Singh, Nagendra↗

Addressing Rising Energy Demand Through Innovation

The U.S. is facing a significant increase in energy demand, driven by AI advancements, the rapid expansion of data centers, manufacturing and industrial growth, and the electrification of transportation and buildings. Buildings alone account for approximately 75% of U.S. electricity consumption and 40% of total energy use. To address these challenges, NLR leverages its state-of-the-art research facilities, advanced energy modeling, hardware-in-the-loop emulation, and real-world demonstrations to provide data-driven insights that de-risk emerging energy solutions, increase efficiency and demand flexibility, optimize grid controls, and identify vulnerabilities to enhance energy security. This presentation will highlight our research ecosystem and its role in supporting a more reliable, affordable, and adaptive energy infrastructure in the face of accelerating demand.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fault Locating, Prediction and Protection (FLPPS)

One of the main objectives of this DOE-sponsored project was to reduce customer outage time. Fault location, prediction, and protection are the most important aspects of fault management for the reduction of outage time. In the past most of the research and development on power system faults in these areas has focused on transmission systems, and it is not until recently with deregulation and competition that research on power system faults has begun to focus on the unique aspects of distribution systems. This project was planned with three Phases, approximately one year per phase. The first phase of the project involved an assessment of the state-of-the-art in fault location, prediction, and detection as well as the design, lab testing, and field installation of the advanced protection system on the SCE Circuit of the Future located north of San Bernardino, CA. The new feeder automation scheme, with vacuum fault interrupters, will limit the number of customers affected by the fault. Depending on the fault location, the substation breaker might not even trip. Through the use of fast communications (fiber) the fault locations can be determined and the proper fault interrupting switches opened automatically. With knowledge of circuit loadings at the time of the fault, ties to other circuits can be closed automatically to restore all customers except the faulted section. This new automation scheme limits outage time and increases reliability for customers. The second phase of the project involved the selection, modeling, testing and installation of a fault current limiter on the Circuit of the Future. While this project did not pay for the installation and testing of the fault current limiter, it did perform the evaluation of the fault current limiter and its impacts on the protection system of the Circuit of the Future. After investigation of several fault current limiters, the Zenergy superconducting, saturable core fault current limiter was selected for installation. Because of some testing problems with the Zenergy fault current limiter, installation was delayed until early 2009 with it being put into operation on March 6, 2009. A malfunction of the FCL controller caused the DC power supply to the superconducting magnet to be turned off. This inserted the FCL impedance into the circuit while it was in normal operation causing a voltage resonance condition. While these voltages never reached a point where damage would occur on customer equipment, steps were taken to insure this would not happen again. The FCL was reenergized with load on December 18, 2009. A fault was experienced on the circuit with the FCL in operation on January 14, 2010. The FCL operated properly and reduced the fault current by about 8%, what was expected from tests and modeling. As of the end of the project, the FCL was still in operation on the circuit. The third phase of the project involved the exploration of several advanced protection ideas that might be at a state where they could be applied to the Circuit of the Future and elsewhere in the SCE electrical system. Based on the work done as part of the literature review and survey, as well as a number of internal meetings with engineering staff at SCE, a number of ideas were compiled. These ideas were then evaluated for applicability and ability to be applied on the Circuit of the Future in the time remaining for the project. Some of these basic ideas were implemented on the circuit including measurement of power quality before and after the FCL. It was also decided that we would take what was learned as part of the Circuit of the Future work and extend it to the next generation circuit protection for SCE. Also at this time, SCE put in a proposal to the DOE for the Irvine Smart Grid Demonstration using ARRA funding. SCE was successful in obtaining funding for this proposal, so it was felt that exploration of new protection schemes for this Irvine Smart Grid Demonstration would be a good use of the project resources. With this in mind, a protection system that uses fault interrupting switches, high speed communications, and looping two radial distribution circuits would have the potential for significant reductions in interruption time and number of interruptions for customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantifying impacts of heat waves on power grid operation

Climate change is projected to cause an increase in the severity and frequency of extreme weather events such as heat waves and droughts. Such changes present planning and operating challenges and risks to many economic sectors. In the electricity sector, statistics of extreme events in the past have been used to help plan for future peak loads, determine associated infrastructure requirements, and evaluate operational risks, but industry-standard planning tools have yet to be coupled with or informed by temperature models to explore the impacts of the "new normal" on planning studies. For example, high ambient temperatures during heat waves reduce the output capacity and efficiency of gas fired combustion turbines just when they are needed most to meet peak demands. This paper describes the development and application of a production cost and unit commitment model coupled to high resolution, hourly temperature data and a temperature dependent load model. The coupled system has the ability to represent the impacts of hourly temperatures on load conditions and available capacity and efficiency of combustion turbines, and therefore capture the potential impacts on system reliability and production cost. Ongoing work expands this capability to address the impacts of water availability and temperature on power grid operation.

Climate change↗

Open Automated Demand Response Communications Specification (Version 1.0)

The development of the Open Automated Demand Response Communications Specification, also known as OpenADR or Open Auto-DR, began in 2002 following the California electricity crisis. The work has been carried out by the Demand Response Research Center (DRRC), which is managed by Lawrence Berkeley National Laboratory. This specification describes an open standards-based communications data model designed to facilitate sending and receiving demand response price and reliability signals from a utility or Independent System Operator to electric customers. OpenADR is one element of the Smart Grid information and communications technologies that are being developed to improve optimization between electric supply and demand. The intention of the open automated demand response communications data model is to provide interoperable signals to building and industrial control systems that are preprogrammed to take action based on a demand response signal, enabling a demand response event to be fully automated, with no manual intervention. The OpenADR specification is a flexible infrastructure to facilitate common information exchange between the utility or Independent System Operator and end-use participants. The concept of an open specification is intended to allow anyone to implement the signaling systems, the automation server or the automation clients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Mechanical Solutions Scan Report

Power lines, poles, and towers are the backbone of the United States (U.S.) electric-power grid. These transmission and distribution networks route electricity from generator to loads. The characteristics of these routes are rapidly changing -- trending towards decentralized renewable generation, electric heating, vehicle charging, and large data-center loads. Coupled with aging infrastructure and the increased frequency of extreme weather events, there is concern about the future reliability and transmission capacity of conductors and adjacent components. This scan report seeks to provide an overview of mechanical solutions to challenges caused by extreme weather events associated with components of transmission and distribution infrastructure, including conductor heat sag, ice accumulation, wind, and wildfire. Many options could increase transmission capacity or reliability, and these are at various stages of technological readiness. Some have only been lab tested, while some have been widely deployed in the U.S. or overseas for decades. The solution categories and providers featured in this report are intended to be comprehensive at the time of publication and to serve as a reference for decision-makers concerned about transmission and distribution reliability. There are two other categories of large, complex solutions, which are not covered in this report: replacing existing conductors with advanced conductors and implementing digital grid enhancing technologies. A separate scan report titled “Advanced Conductor Scan Report,” which discusses advanced carbon-core conductors, was published by the Idaho National Laboratory (INL) in 2023. Information on digital technologies, such as dynamic line ratings, power-flow controllers, and other power electronics and communications-based devices, can be found on the Grid- Enhancing Technologies landing page. Mechanical grid-enhancing technologies, or solutions covered in this report, often do not require full equipment replacement and do not rely on digital components. Mechanical technologies are overlooked because they may be older, simpler, or seemingly “more obvious” than digital or carbon-core technologies. However, it is wise to consider mechanical solutions in a thorough evaluation of grid enhancing technology solutions.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating the Need for Adaptive Droop Control for Grid-Forming Inverters in Islanded and Grid-Connected Modes

This paper demonstrates the need of adaptive droop of grid-forming (GFM) inverters operating in different operation modes (grid-connected and islanded). A pure hardware microgrid comprising multiple grid-forming (GFM) inverters from different vendors, multiple grid-following inverters, and a diesel generator is used for the demonstration. The key findings are summarized as follows: Tighter droop slope should be used in the islanded mode, and looser droop slope should be used in the grid-connected mode to ensure stability. It is important to have adaptive droop control in GFM inverters to ensure stable and reliable microgrid operation.

14 SOLAR ENERGY↗

Transmission Cost Allocation Methodologies for Regional Transmission Organizations

This report describes transmission cost allocation methodologies for transmission projects developed to maintain or enhance reliability, to interconnect new generators, or to access new resources and enhance competitive bulk power markets, otherwise known as economic transmission projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗