Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gravity currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Planck 2018 results

We report on the implications for cosmic inflation of the 2018 release of the Planck cosmic microwave background (CMB) anisotropy measurements. The results are fully consistent with those reported using the data from the two previous Planck cosmological releases, but have smaller uncertainties thanks to improvements in the characterization of polarization at low and high multipoles. Planck temperature, polarization, and lensing data determine the spectral index of scalar perturbations to be n s = 0.9649 ± 0.0042 at 68% CL. We find no evidence for a scale dependence of n s , either as a running or as a running of the running. The Universe is found to be consistent with spatial flatness with a precision of 0.4% at 95% CL by combining Planck with a compilation of baryon acoustic oscillation data. The Planck 95% CL upper limit on the tensor-to-scalar ratio, r0.002 < 0.10, is further tightened by combining with the BICEP2/Keck Array BK15 data to obtain r 0.002 < 0.056. In the framework of standard single-field inflationary models with Einstein gravity, these results imply that: (a) the predictions of slow-roll models with a concave potential, V"(Φ) < 0, are increasingly favoured by the data; and (b) based on two different methods for reconstructing the inflaton potential, we find no evidence for dynamics beyond slow roll. Three different methods for the non-parametric reconstruction of the primordial power spectrum consistently confirm a pure power law in the range of comoving scales 0.005 Mpc -1 ≲ k ≲ 0.2 Mpc -1 . A complementary analysis also finds no evidence for theoretically motivated parameterized features in the Planck power spectra. For the case of oscillatory features that are logarithmic or linear in k, this result is further strengthened by a new combined analysis including the Planck bispectrum data. The new Planck polarization data provide a stringent test of the adiabaticity of the initial conditions for the cosmological fluctuations. In correlated, mixed adiabatic and isocurvature models, the non-adiabatic contribution to the observed CMB temperature variance is constrained to 1.3%, 1.7%, and 1.7% at 95% CL for cold dark matter, neutrino density, and neutrino velocity, respectively. Planck power spectra plus lensing set constraints on the amplitude of compensated cold dark matter-baryon isocurvature perturbations that are consistent with current complementary measurements. The polarization data also provide improved constraints on inflationary models that predict a small statistically anisotropic quadupolar modulation of the primordial fluctuations. However, the polarization data do not support physical models for a scale-dependent dipolar modulation. All these findings support the key predictions of the standard single-field inflationary models, which will be further tested by future cosmological observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Technological and Medical Human Health and Well-Being Options in Deep Space

Zeroth order, maintenance of human health requires supportive protection from the hazards of space, including supplying breathable air, comfortable temperatures, a supportive diet/nutrition, radiation protection, and sufficient gravity to avoid the combinatorial impacts of such effecting human operability and health. Spacecraft operability must be “fail-safe” to ensure these basic human life support conditions are maintained throughout the mission and the mission(s) must be affordable. There are known effects and unknowns effects regarding aspects of human health for Mars duration missions. Mars has the order of a third g. We have no data regarding the health impacts of this on humans or the combinatorial effects associated with 45% GCR on the Martian surface over time. There is a suspicion that if humans survive such conditions over long times they will evolve to living at reduced g and become “Martians”. Cascading failures and subcritical degradations in systems of systems causing an overall unrecoverable failure are a potential issue. There are two exremely complex systems associated with humans-Mars missions: the technical, engineering, and architectural system of systems that enable the mission and the humans. Both need to be mutually configured and operated to mitigate the overall risks and hazards of the mission. Regarding the humans that mitigation includes both the mission risks and supporting-to-increasing the human immune and other concomitant physiological systems. This report will summarize the risks, current mitigation approaches, and putative approaches including lifestyle, nutrition, and “wellness” approaches to possibly improve the human capacity to withstand the large number of combinatorial human physiological rigors of the missions. The wellness observations also apply to and are derived from Earth terrestrial applicable research.

Dennis M Bushnell↗

Formation of Planetary Systems

Stars are observed to be forming within cold regions of the galaxy called molecular clouds. A clump of gas and dust within a molecular cloud can collapse into a rotationally- supported disk orbiting the pre s sure -supported star. Such a disk has the same initial elemental composition as the growing star. At sufficient distances from the central star, it is cool enough for approx. 1 - 2% of this material to be in solid form, either remnant interstellar grains or condensates formed within the disk. During the infall stage, the disk is very active and probably highly turbulent. When the infall slows substantially or stops, the disk becomes more quiescent. The dust grows from micron-sized dust to kilometer-sized planetesimals by physical collisions, possibly aided by collective gravity. The dynamics of larger solid bodies within protoplanetary disks are better characterized. The primary perturbations on the orbits of kilometer-sized and larger planetesimals in protoplanetary disks are mutual gravitational interactions and physical collisions. These interactions lead to accretion (and in some cases erosion and fragmentation) of planetesimals. The most massive planets have the largest gravitationally-enhanced collision cross-sections, and accrete almost everything with which they collide. The size distribution of solid bodies becomes quite skewed, with a few large bodies growing much faster than the rest of the swarm, until they have accumulated most of the small bodies within their gravitational reach. Slower growth continues (at least for solid, earth-like planets) as the eccentricities of planetary embryos are pumped up by long-range mutual gravitational perturbations. As planetary masses increase, they become more efficient at stirring random velocities of neighboring bodies. If sufficiently massive and dense planets exist far enough from the star, they can eject material into interstellar space. In most models, giant planets begin their growth like terrestrial planets, but if they become massive enough before the protoplanetary disk dissipates, then they are able to accumulate substantial amounts of gas. Giant planet growth times predicted by current models are similar to estimates of the lifetime of the gaseous protoplanetary disk, so we don't know whether or not giant planets form in most protoplanetary disks. However, planets that become massive while a substantial amount of gas remains in the disk may migrate into the star as a consequence of their gravitational interactions with the disk.

Lissauer, Jack J.↗

Optimal Stimulus Amplitude for Vestibular Stochastic Stimulation to Improve Sensorimotor Function

Sensorimotor changes such as postural and gait instabilities can affect the functional performance of astronauts when they transition across different gravity environments. We are developing a method, based on stochastic resonance (SR), to enhance information transfer by applying non-zero levels of external noise on the vestibular system (vestibular stochastic resonance, VSR). Our previous work has shown the advantageous effects of VSR in a balance task of standing on an unstable surface. This technique to improve detection of vestibular signals uses a stimulus delivery system that is wearable or portable and provides imperceptibly low levels of white noise-based binaural bipolar electrical stimulation of the vestibular system. The goal of this project is to determine optimal levels of stimulation for SR applications by using a defined vestibular threshold of motion detection. A series of experiments were carried out to determine a robust paradigm to identify a vestibular threshold that can then be used to recommend optimal stimulation levels for SR training applications customized to each crewmember. Customizing stimulus intensity can maximize treatment effects. The amplitude of stimulation to be used in the VSR application has varied across studies in the literature such as 60% of nociceptive stimulus thresholds. We compared subjects' perceptual threshold with that obtained from two measures of body sway. Each test session was 463s long and consisted of several 15s sinusoidal stimuli, at different current amplitudes (0-2 mA), interspersed with 20-20.5s periods of no stimulation. Subjects sat on a chair with their eyes closed and had to report their perception of motion through a joystick. A force plate underneath the chair recorded medio-lateral shear forces and roll moments. First we determined the percent time during stimulation periods for which perception of motion (activity above a pre-defined threshold) was reported using the joystick, and body sway (two standard deviation of the noise level in the baseline measurement) was detected by the sensors. The percentage time at each stimulation level for motion detection was normalized with respect to the largest value and a logistic regression curve fit was applied to these data. The threshold was defined at the 50% probability of motion detection. Comparison of threshold of motion detection obtained from joystick data versus body sway suggests that perceptual thresholds were significantly lower, and were not impacted by system noise. Further, in order to determine optimal stimulation amplitude to improve balance, two sets of experiments were carried out. In the first set of experiments, all subjects received the same level of stimuli and the intensity of optimal performance was projected back on subjects' vestibular threshold curve. In the second set of experiments, on different subjects, stimulation was administered from 20-400% of subjects' vestibular threshold obtained from joystick data. Preliminary results of our study show that, in general, using stimulation amplitudes at 40-60% of perceptual motion threshold improved balance performance significantly compared to control (no stimulation). The amplitude of vestibular stimulation that improved balance function was predominantly in the range of +/- 100 to +/- 400 micro A. We hypothesize that VSR stimulation will act synergistically with sensorimotor adaptability (SA) training to improve adaptability by increasing utilization of vestibular information and therefore will help us to optimize and personalize a SA countermeasure prescription. This combination will help to significantly reduce the number of days required to recover functional performance to preflight levels after long-duration spaceflight.

Goel, R.↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗

A Micromechanical INS/GPS System for Small Satellites

The cost and complexity of large satellite space missions continue to escalate. To reduce costs, more attention is being directed toward small lightweight satellites where future demand is expected to grow dramatically. Specifically, micromechanical inertial systems and microstrip global positioning system (GPS) antennas incorporating flip-chip bonding, application specific integrated circuits (ASIC) and MCM technologies will be required. Traditional microsatellite pointing systems do not employ active control. Many systems allow the satellite to point coarsely using gravity gradient, then attempt to maintain the image on the focal plane with fast-steering mirrors. Draper's approach is to actively control the line of sight pointing by utilizing on-board attitude determination with micromechanical inertial sensors and reaction wheel control actuators. Draper has developed commercial and tactical-grade micromechanical inertial sensors, The small size, low weight, and low cost of these gyroscopes and accelerometers enable systems previously impractical because of size and cost. Evolving micromechanical inertial sensors can be applied to closed-loop, active control of small satellites for micro-radian precision-pointing missions. An inertial reference feedback control loop can be used to determine attitude and line of sight jitter to provide error information to the controller for correction. At low frequencies, the error signal is provided by GPS. At higher frequencies, feedback is provided by the micromechanical gyros. This blending of sensors provides wide-band sensing from dc to operational frequencies. First order simulation has shown that the performance of existing micromechanical gyros, with integrated GPS, is feasible for a pointing mission of 10 micro-radians of jitter stability and approximately 1 milli-radian absolute error, for a satellite with 1 meter antenna separation. Improved performance micromechanical sensors currently under development will be suitable for a range of micro-nano-satellite applications.

Barbour, N.↗

Splashing Droplets

Current data on droplet breakup is scarce for the sizes and velocities typical of practical applications such as in spray combustion processes and coating processes. While much more representative of practical applications, the small spatial scales and rapid time-scales prevent detailed measurement of the internal fluid dynamics and liquid property gradients produced by impinging upon surfaces. Realized through the extended spatial and temporal scales afforded by a microgravity environment, an improved understanding of drop breakup dynamics is sought to understand and ultimately control the impingement dynamics of droplets upon surfaces in practical situations. The primary objective of this research will be to mark the onset of different 'splashing modes' and to determine their temperature, pressure and angle dependence for impinging droplets representative of practical fluids. In addition, we are modeling the evolution of droplets that do not initially splash but rather undergo a 'fingering' evolution observed on the spreading fluid front and the transformation of these fingers into splashed products. An example of our experimental data is presented below. These images are of Isopar V impacting a mirror-polished surface. They were acquired using a high-speed camera at 1000 frames per second. They show the spreading of a single droplet after impact and ensuing finger instabilities. Normal gravity experimental data such as this will guide low gravity measurements in the 2.2 second drop tower and KC-135 aircraft as available. Presently we are in the process of comparing the experimental data of droplet shape evolution to numerical models, which can also capture the internal fluid dynamics and liquid property gradients such as produced by impingement upon a heated surface. To-date isothermal numerical data has been modeled using direct numerical simulations of representative splashing droplets. The data obtained so far indicates that the present model describes well the droplet wall interactions to a point in time just before splash. Additional information is included in the original extended abstract.

VanderWal, Randall L.↗

Study of geopotential error models used in orbit determination error analysis

The uncertainty in the geopotential model is currently one of the major error sources in the orbit determination of low-altitude Earth-orbiting spacecraft. The results of an investigation of different geopotential error models and modeling approaches currently used for operational orbit error analysis support at the Goddard Space Flight Center (GSFC) are presented, with emphasis placed on sequential orbit error analysis using a Kalman filtering algorithm. Several geopotential models, known as the Goddard Earth Models (GEMs), were developed and used at GSFC for orbit determination. The errors in the geopotential models arise from the truncation errors that result from the omission of higher order terms (omission errors) and the errors in the spherical harmonic coefficients themselves (commission errors). At GSFC, two error modeling approaches were operationally used to analyze the effects of geopotential uncertainties on the accuracy of spacecraft orbit determination - the lumped error modeling and uncorrelated error modeling. The lumped error modeling approach computes the orbit determination errors on the basis of either the calibrated standard deviations of a geopotential model's coefficients or the weighted difference between two independently derived geopotential models. The uncorrelated error modeling approach treats the errors in the individual spherical harmonic components as uncorrelated error sources and computes the aggregate effect using a combination of individual coefficient effects. This study assesses the reasonableness of the two error modeling approaches in terms of global error distribution characteristics and orbit error analysis results. Specifically, this study presents the global distribution of geopotential acceleration errors for several gravity error models and assesses the orbit determination errors resulting from these error models for three types of spacecraft - the Gamma Ray Observatory, the Ocean Topography Experiment, and the Cosmic Background Explorer.

Yee, C.↗

Reactions and Surface Transformations of a Bone-Bioactive Material in a Simulated Microgravity Environment

A comprehensive program to investigate the expeditious in vitro formation of three-dimensional bone-like tissue is currently underway at the University of Pennsylvania. The study reported here forms a part of that program. Three-dimensional bone-like tissue structures may be grown under the simulated microgravity conditions of NASA designed Rotating Wall Bioreactor Vessels (RWV's). Such tissue growth will have wide clinical applications. In addition, an understanding of the fundamental changes that occur to bone cells under simulated microgravity would yield important information that will help in preventing or minimizing astronaut bone loss, a major health issue with travel or stay in space over long periods of time. The growth of three-dimensional bone-like tissue structures in RWV's is facilitated by the use of microcarriers which provide structural support. If the microcarrier material additionally promotes bone cell growth, then it is particularly advantageous to employ such microcarriers. We have found that reactive, bone-bioactive glass (BBG) is an attractive candidate for use as microcarrier material. Specifically, it has been found that BBG containing Ca- and P- oxides upregulates osteoprogenitor cells to osteoblasts. This effect on cells is preceded by BBG reactions in solution which result in the formation of a Ca-P surface layer. This surface further transforms to a bone-like mineral (i.e., carbonated crystalline hydroxyapatite (c-HA)). At normal gravity, time-dependent, immersion-induced BBG reactions and transformations are greatly affected both by variations in the composition of the milieu in which the glass is immersed and on the immersion conditions. However, the nature of BBG reactions and phase transformations under the simulated microgravity conditions of RWV's are unknown, and must be understood in order to successfully use BBG as microcarrier material in RWV'S. In this paper, we report some of our recent findings in this regard using experimental and numerical methods. BBG composition 45S5, the most reactive among known bone-bioactive glasses, was chosen for the study. BBG 45S5 behavior in physiological solutions was tested in simulated microgravity and compared with that at normal gravity. On the basis of our numerical study, we have chosen the BBG granule size to be in the range 40-70 microns, and a RWV rotational speed of 10 rpm. Our numerical study has shown that these parameters enable the microcarrier to remain suspended in the medium without experiencing collisions with the wall of the vessel. Immersion-induced changes in the solution composition and the material surface were analyzed after immersion.

Radin, S.↗

The Deep Space 1 and Space Technology 4/Champollion Missions

NASA's New Millennium Program (NMP) is designed to develop, test, and flight validate new, advanced technologies for planetary and Earth exploration missions, using a series of low cost spacecraft. Two of NMP's current missions include encounters with comets and asteroids. The Deep Space 1 mission was launched on October 24, 1998 and will fly by asteroid 1992 KD on July 29, 1999, and possibly Comet Wilson-Harrington and/or Comet Borrelly in 2001. The Space Technology 4/Champollion mission will be launched in April, 2003 and will rendezvous with, orbit and land on periodic Comet Tempel 1 in 2006. ST-4/Champollion is a joint project with CNES, the French space agency. The DS-1 mission is going well since launch and has already validated several major technologies, including solar electric propulsion (SEP), solar concentrator arrays, a small deep space transponder, and autonomous navigation. The spacecraft carries two scientific instruments: MICAS, a combined visible camera and UV and IR spectrometers, and PEPE, an ion and electron spectrometer. Testing of the science instruments is ongoing. Following the asteroid encounter in July, 1999, DS-1 will go on to encounters with one or both comets if NASA approves funding for an extended mission. The ST-4/Champollion mission will use an advanced, multi-engine SEP system to effect a rendezvous with Comet P/Tempel 1 in February, 2006, after a flight time of 2.8 years. After orbiting the comet for several months in order to map its surface and determine its gravity field, ST-4/Champollion will descend to the comet's surface and will anchor itself with a 3-meter long harpoon. Scientific experiments include narrow and wide angle cameras for orbital mapping, panoramic and near-field cameras for landing site mapping, a gas chromatograph/mass spectrometer, a combined microscope and infrared spectrometer, and physical properties probes. Cometary samples will be obtained from depths up to 1.4 meters. The spacecraft is solar powered with rechargeable batteries, thus allowing a long duration mission on the nucleus surface. At the time of this writing, the ST-4/Champollion spacecraft was undergoing a major redesign to fit within NASA cost constraints, and approval of the mission is pending.

Weissman, Paul R.↗

Comet and Asteroid Missions in NASA's New Millennium Program

NASA's New Millennium Program (NMP) is designed to develop, test, and flight validate new, advanced technologies for planetary and Earth exploration missions, using a series of low cost spacecraft. Two of NMP's current missions include encounters with comets and asteroids. The Deep Space 1 mission was launched on October 24, 1998 and will fly by asteroid 1992 KD on July 29, 1999, and possibly Comet Wilson-Harrington and/or Comet Borrelly in 2001. The Space Technology 4/Champollion mission will be launched in April, 2003 and will rendezvous with, orbit and land on periodic Comet Tempel 1 in 2006. ST-4/Champollion is a joint project with CNES, the French space agency. The DS-1 mission is going well since launch and has already validated several major technologies, including solar electric propulsion (SEP), solar concentrator arrays, a small deep space transponder, and autonomous navigation. The spacecraft carries two scientific instruments: MICAS, a combined visible camera and UV and IR spectrometers, and PEPE, an ion and electron spectrometer. Testing of the science instruments is ongoing. Following the asteroid encounter in July, 1999, DS-1 will go on to encounters with one or both comets if NASA approves funding for an extended mission. The ST-4/Champollion mission will use an advanced, multi-engine SEP system to effect a rendezvous with Comet P/Tempel 1 in February, 2006, after a flight time of 2.8 years. After orbiting the comet for several months in order to map its surface and determine its gravity field, ST-4/Chainpollion will descend to the comet's surface and will anchor itself with a 3-meter long harpoon. Scientific experiments include narrow and wide angle cameras for orbital mapping, panoramic and near-field cameras for landing site mapping, a gas chromatograph/mass spectrometer, a combined microscope and infrared spectrometer, and physical properties probes. Cometary samples will be obtained from depths up to 1.4 meters. The spacecraft is solar powered with rechargeable batteries, thus allowing a long duration mission on the nucleus surface. At the time of this writing, the ST-4/Champollion spacecraft was undergoing a major redesign to fit within NASA cost constraints, and approval of the mission is pending.

Weissman, Paul R.↗

Modeling of Orbital and Attitude Dynamics of Nanosatellites Controlled via Active Electrostatic Charging

The large-scale exploration of airless bodies, such as asteroids and moons, is gaining interest, however it is limited by mobility issues: the lack of atmosphere, low gravity, and unknown soil properties pose difficult challenges for many forms of traditional locomotion. The environment in proximity of these bodies is also electrically charged due to interactions with solar wind and UV radiation. The EGlider (Electrostatic Glider) concept would be able to overcome these mobility issues by leveraging the natural environment, allowing operations in close proximity of the surface, while enabling long duration missions by minimizing propellant consumption. The EGlider is an advanced concept for small satellite mobility and propulsion, which relies on the electric fields naturally present around airless bodies in order to generate forces and torques useful for maneuvering. It does so by extending electrically charged appendages, which enable it to electrostatically soar above the surface. By differentially charging its electrodes it can also produce torques to control its attitude. The charges are maintained by continuous active ion or electron emission from the spacecraft, in order to cancel out the neutralizing influx of charges from surrounding plasma. An investigation of the spacecraft-plasma interaction was carried out. This included studying the effect of electrode geometry and calculating the charge-to-mass ratios required to enable several mission scenarios. Long, thin wire electrodes were identified to be the most power-efficient and would allow power-to-weight ratios achievable with current nanosatellite technologies. High electrode potential represents the main limiting factor for the system design. In order to test the feasibility of active control by means of differential charging, a simple 2D interaction model was developed, and a feedback controller to stabilize the vehicle was tested in a simulation environment. The results confirmed that good performance could be obtained for both position and attitude control. Finally, a dedicated software was developed for future simulation and testing of control strategies for the EGlider. This software allows to study the trajectory and attitude of an arbitrarily configured spacecraft in the proximity of an arbitrarily defined main airless body. The spacecraft can be assembled from basic parts, each with specified electrical, mass and optical properties. Efficient models allow to calculate gravitational and electrical interactions with the rotating main body and the local plasma field, as well as solar radiation pressure effects. Control models can be implemented as simple plug-in functions and easily tested. The preliminary validation campaign showed good matching with the reference cases that have been analyzed.

Corpino, Sabrina↗

SAO and Kelvin Waves in the EuroGRIPS GCMS and the UK Meteorological Offices Analyses

This work is an intercomparison of four tropospheric-stratospheric climate models, the Unified Model (UM) of the U.K. Meteorological Office (UKMO), the model of the Free University in Berlin (FUB). the ARPEGE-climat model of the National Center for Meteorological Research (CNRM), and the Extended UGAMP GCM (EUGCM) of the Center for Global Atmospheric Modelling (CGAM), against the UKMO analyses. This comparison has been made in the framework of the "GSM-Reality Intercomparison Project for SPARC" (GRIPS). SPARC (Stratospheric Processes and their Role in Climate) aims are to investigate the effects of the middle atmosphere on climate and the GRIPS purpose is to organized a comprehensive assessment of current Middle Atmosphere-Climate Models (MACMs). The models integrations were made without identical contraints e.g. boundary conditions, incoming solar radiation). All models are able to represent the dominant features of the extratropical circulation. In this paper, the structure of the tropical winds and the strengths of the Kelvin waves are examined. Explanations for the differences exhibited. between the models. as well as between models and analyses, are also proposed. In the analyses a rich spectrum of waves (eastward and westward) is present and contributes to drive the SAO (SemiAnnual Oscillation) and the QBO (Quasi-Biennal Oscillation). The amplitude of the Kelvin waves is close to the one observed in UARS (Upper Atmosphere Research Satellite) data. In agreement with observations, the Kelvin waves generated in the models propagate into the middle atmosphere as wave packets which underlines convective forcing origin. In most models, slow Kelvin waves propagate too high and are hence overestimated in the upper stratosphere and in the mesosphere, except for the UM which is more diffusive. These waves are not sufficient to force realistic westerlies of the QBO or SAO westerly phases. If the SAO is represented by all models only two of them are able to generate westerlies between 10 hPa and 50 hPa. The importance of the role played by subgrided gravity waves is more and more recognized. Actually, the EUGCM which includes a parametrization of gravity waves with a non-zero phase speed is able to simulate. with however some unrealistic features, clear easterly to westerly transitions as well as westerlies downward propagations. Thermal damping is also important in the westerlies forcing in the stratosphere. The model ARPEGE-climat shows more westerlies in the stratosphere than tile other three models probably due to the use of a simplified scheme to predict the ozone distribution in the middle atmosphere.

Amodei, M.↗

Investigation of a geodesy coexperiment to the Gravity Probe B relativity gyroscope program

Geodesy is the science of measuring the gravitational field of and positions on the Earth. Estimation of the gravitational field via gravitation gradiometry, the measurement of variations in the direction and magnitude of gravitation with respect to position, is this dissertation's focus. Gravity Probe B (GP-B) is a Stanford satellite experiment in gravitational physics. GP-B will measure the precession the rotating Earth causes on the space time around it by observing the precessions of four gyroscopes in a circular, polar, drag-free orbit at 650 km altitude. The gyroscopes are nearly perfect niobium-coated spheres of quartz, operating at 1.8 K to permit observations with extremely low thermal noise. The permissible gyroscope drift rate is miniscule, so the torques on the gyros must be tiny. A drag-free control system, by canceling accelerations caused by nongravitational forces, minimizes the support forces and hence torques. The GP-B system offers two main possibilities for geodesy. One is as a drag-free satellite to be used in trajectory-based estimates of the Earth's gravity field. We described calculations involving that approach in our previous reports, including comparison of laser only, GPS only, and combined tracking and a preliminary estimate of the possibility of estimating relativistic effects on the orbit. The second possibility is gradiometry. This technique has received a more cursory examination in previous reports, so we concentrate on it here. We explore the feasibility of using the residual suspension forces centering the GP-B gyros as gradiometer signals for geodesy. The objective of this work is a statistical prediction of the formal uncertainty in an estimate of the Earth's gravitation field using data from GP-B. We perform an instrument analysis and apply two mathematical techniques to predict uncertainty. One is an analytical approach using a flat-Earth approximation to predict geopotential information quality as a function of spatial wavelength. The second estimates the covariance matrix arising in a least-squares estimate of a spherical harmonic representation of the geopotential using GP-B gradiometer data. The results show that the GP-B data set can be used to create a consistent estimate of the geopotential up to spherical harmonic degree and order 60. The formal uncertainty of all coefficients between degrees 5 and 50 is reduced by factors of up to 30 over current satellite-only estimates and up to 7 over estimates which include surface data. The primary conclusion resulting from this study is that the gravitation gradiometer geodesy coexperiment to GP-B is both feasible and attractive.

Everitt, C. W. F.↗

Modeling and Simulation Efforts to Support Improved Comfort in ARGOS

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch, and here we present preliminary modeling of that device using the open-source biomechanical tool OpenSim [1,2] with an in-house developed plugin. We analyze a series of motions performed by a single shirt-sleeved subject with goals of characterizing the device, validating the model, and predicting whether reduced gravity conditions (i.e., lunar gravity (Lg) or Martian gravity (Mg)) can be accurately simulated with the device, as well as providing comfort to the ARGOS user. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are either obtained from (1) inverse kinematics (IK) using motion capture markers on the various components of the device or (2) calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. Given the joint angles of the device, the resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) in order to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data and the forces from manual measurements of the spring both independently and integrated within the device. We found that calculated joint angles generally represent the angles measured and computed with IK, supporting a possible analysis workflow inputting human motion data and observing system behavior under varied design parameters. In two different device configurations in which the maximum applied force was 131 N, our current model accurately captured force with a difference of 2-3 N from measured loads. Though our initial test was performed with a shirt-sleeve subject, arm weights were added to emulate the weight of the suit sleeve and the subject was positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup. Arm range of motion tasks were performed outside of the HUT, inside the HUT, and inside the HUT while using the device. A variety of other upper body tasks were completed as well. In summary, we have developed a model to investigate and verify an upper limb offload device currently in development. We believe this model will be a valuable tool not only for device characterization but also to predict proper configurations to simulate Lg or Mg conditions, investigate range of motion concerns, predict limitations such as internal collisions and contacts, and inform future design improvements.

L B Nilsson↗

Comments on the quantum field theory of the Coulomb gas formalism

The holomorphic Coulomb gas formalism, as developed by Feigin-Fuchs, Dotsenko-Fateev and Felder, is a set of rules for computing minimal model observables using free field techniques. We attempt to derive and clarify these rules using standard techniques of quantum field theory. We begin with a careful examination of the timelike linear dilaton. Although the background charge of the model breaks the scalar field’s continuous shift symmetry, the exponential of the action remains invariant under a discrete shift because the background charge is imaginary. Gauging this symmetry makes the dilaton compact and introduces winding modes into the spectrum. One of these winding operators corresponds to the anti-holomorphic completion of the BRST current first introduced by Felder, and the full left/right cohomology of this BRST charge isolates the irreducible representations of the Virasoro algebra within the degenerate Fock space of the linear dilaton. The “supertrace” in the BRST complex reproduces the minimal model partition function and exhibits delicate cancellations between states with both momentum and winding. The model at the radius $R=\sqrt{pp^{\prime }}$ has two marginal operators corresponding to the Dotsenko-Fateev “screening charges”. Deforming by them, we obtain a model that might be called a “BRST quotiented compact timelike Liouville theory”. The Hamiltonian of the zero-mode quantum mechanics of this model is not Hermitian, but it is PT -symmetric and exactly solvable. Its eigenfunctions have support on an infinite number of plane waves, suggesting an infinite reduction in the number of independent states in the full quantum field theory. Applying conformal perturbation theory to the exponential interactions reproduces the Coulomb gas calculations of minimal model correlation functions. In contrast to spacelike Liouville, these “resonance correlators” are finite because the zero mode is compact. We comment on subtleties regarding the reflection operator identification, as well as naive violations of truncation in correlators with multiple reflection operators inserted. This work is part of an attempt to understand the relationship between the JT model of two dimen- sional gravity and the worldsheet description of the (2 , p ) minimal string as suggested by Seiberg and Stanford.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Locomotion in a rotating space station: a synthesis of new data with established concepts

Despite technical problems associated with designing a rotating space station it is still thought that such a device may provide a more tolerable work environment and prevent some of the physiological changes that currently pose a threat to long-duration space missions. In the present analysis four case studies are presented and the results show that centrifugal and Coriolis effects could hinder one's ability to walk or run in a natural way in such an environment. In a rotating station that has a nominal 'G-level' equal to that on earth it can be shown that a person running at 3.8 m s -1 could experience foot 'heaviness' effects that range from 1 to 3 g and fore-aft foot 'forces' that range fom -0.5 to +0.5 g. In contrast the hip region could sense a relatively constant 'force' equal to 2 g. With regard to the body as a whole there would be 'weight changes' that depended on the direction of gait. While these conditions imply that locomotion in a rotating space station would be different from normal gait, it is likely that given sufficient training, astronauts could learn optimal strategies to account for centrifugal and Coriolis effects on individual body segments. The learning process would also entail developing strategies on which route to take when moving from one location to another, since in many cases the shortest route would not be the least energy consuming. Such training would be justified if it were shown that artificial gravity was an effective countermeasure to the problems of muscle atrophy and bone loss.

NASA Discipline Musculoskeletal↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗