Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Exploring Whether Subsurface Fluid Production Can Minimize Triggered Seismicity in Geothermal Fields

Fluid injection and production related to energy recovery and other industrial operations alter the pressure and stress state of subsurface reservoirs which can lead to induced seismicity. Here, the primary goal is to investigate the hypothesis that the modulation of stress state in subsurface reservoirs through fluid injection/production operations can reduce the likelihood of inducing seismicity. Validation of this mitigation strategy will provide an active operational method to control induced seismicity in subsurface reservoir exploitations such as geothermal energy recovery and carbon storage. In this project, we analyze the relationship between extensive fluid production and the paucity of aftershock activity at the Coso Geothermal plant (CGP) following the 2019 Ridgecrest earthquake sequence, where high rates of aftershock triggering were expected. We developed a high-fidelity multiphase coupled thermo-hydro-mechanical (THM) model to simulate fluid injection/production activities at the CGP between 1986 and 2020. THM results of surface subsidence due to high rates of fluid production agree well with field observations from global positioning system (GPS) and interferometric synthetic aperture radar (InSAR). Subsequently, the variations of pore pressure, temperature and stress state were used to drive numerical earthquake simulations of the aftershock response to the 2019 Ridgecrest earthquakes. The earthquake simulations show that seismic quiescence may occur following the Ridgecrest event, depending on the initial stress state at the time of the mainshock and at the initiation of geothermal energy production. Seismic quiescence occurs in 20% of the cases we explored, where rates are decreased by 50% of the background rate in the two years following the mainshock. In circumstances where aftershock rates increase near the CGP following Ridgecrest, the average rate change is a factor of two larger than background rates from simulations with no operations. These findings indicate that unlike many other operations that bring faults closer to failure, operations at the CGP are acting to stabilize faults such that triggering in the current stress state is minimal.

58 GEOSCIENCES↗

Scaling of two-phase water-steam relative permeability and thermal fluxes in porous media

Two-phase water-steam flow conditions are frequently encountered in many engineering applications, including geothermal reservoirs. Although routine calculations are based on the multiphase Darcy’s law, the role of the topology of the flowing phases at the pore-scale is usually neglected in the estimation of relative permeabilities. Instead, the latter are frequently computed using empirical models like the Corey correlation. In this work, we first apply the model for relative permeabilities based on pore-scale flow regimes developed by Picchi and Battiato (2019), Relative permeability scaling from pore-scale flow regimes, Water Resour. Res. 55, 3215–3233, to scenarios typical of geothermal reservoirs and then extend it by deriving the scaling laws for the transmissibilities and the thermal properties as a function of temperature. First, we discuss the scaling behavior of normalized relative permeabilities in terms of viscosity ratio and capillary number of water-steam systems and, then, we provide a validation of the model against experimental data available in the literature. The model captures well the data trends collected in real 3D porous media. These results suggest that water-steam relative permeabilities follow the same scaling behavior of gas-liquid systems where the non-wetting phase is much less viscous than the wetting phase. Finally, we investigate the impact that relative permeabilities have on heat transfer rates at two-phase flow conditions and the scaling of mass and energy transmissibility and thermal properties of the mixture. An estimation of the exergy carried by the two-phase water-steam mixture is also included.

42 ENGINEERING↗

Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Foundation Heat Exchanger Final Report: Demonstration, Measured Performance, and Validated Model and Design Tool

Geothermal heat pumps, sometimes called ground-source heat pumps (GSHPs), have been proven capable of significantly reducing energy use and peak demand in buildings. Conventional equipment for controlling the temperature and humidity of a building, or supplying hot water and fresh outdoor air, must exchange energy (or heat) with the building's outdoor environment. Equipment using the ground as a heat source and heat sink consumes less non-renewable energy (electricity and fossil fuels) because the earth is cooler than outdoor air in summer and warmer in winter. The most important barrier to rapid growth of the GSHP industry is high first cost of GSHP systems to consumers. The most common GSHP system utilizes a closed-loop ground heat exchanger. This type of GSHP system can be used almost anywhere. There is reason to believe that reducing the cost of closed-loop systems is the strategy that would achieve the greatest energy savings with GSHP technology. The cost premium of closed-loop GSHP systems over conventional space conditioning and water heating systems is primarily associated with drilling boreholes or excavating trenches, installing vertical or horizontal ground heat exchangers, and backfilling the excavations. This project investigates reducing the cost of horizontal closed-loop ground heat exchangers by installing them in the construction excavations, augmented when necessary with additional trenches. This approach applies only to new construction of residential and light commercial buildings or additions to such buildings. In the business-as-usual scenario, construction excavations are not used for the horizontal ground heat exchanger (HGHX); instead the HGHX is installed entirely in trenches dug specifically for that purpose. The potential cost savings comes from using the construction excavations for the installation of ground heat exchangers, thereby minimizing the need and expense of digging additional trenches. The term foundation heat exchanger (FHX) has been coined to refer exclusively to ground heat exchangers installed in the overcut around the basement walls. The primary technical challenge undertaken by this project was the development and validation of energy performance models and design tools for FHX. In terms of performance modeling and design, ground heat exchangers in other construction excavations (e.g., utility trenches) are no different from conventional HGHX, and models and design tools for HGHX already exist. This project successfully developed and validated energy performance models and design tools so that FHX or hybrid FHX/HGHX systems can be engineered with confidence, enabling this technology to be applied in residential and light commercial buildings. The validated energy performance model also addresses and solves another problem, the longstanding inadequacy in the way ground-building thermal interaction is represented in building energy models, whether or not there is a ground heat exchanger nearby. Two side-by-side, three-level, unoccupied research houses with walkout basements, identical 3,700 ft{sup 2} floor plans, and hybrid FHX/HGHX systems were constructed to provide validation data sets for the energy performance model and design tool. The envelopes of both houses are very energy efficient and airtight, and the HERS ratings of the homes are 44 and 45 respectively. Both houses are mechanically ventilated with energy recovery ventilators, with space conditioning provided by water-to-air heat pumps with 2 ton nominal capacities. Separate water-to-water heat pumps with 1.5 ton nominal capacities were used for water heating. In these unoccupied research houses, human impact on energy use (hot water draw, etc.) is simulated to match the national average. At House 1 the hybrid FHX/HGHX system was installed in 300 linear feet of excavation, and 60% of that was construction excavation (needed to construct the home). At House 2 the hybrid FHX/HGHX system was installed in 360 feet of excavation, 50% of which was construction excavation. There are six pipes in all excavations (three parallel circuits - out and back), and the multiple instances of FHX and/or HGHX are all connected in series. The working fluid is 20% by weight propylene glycol in water. Model and design tool development was undertaken in parallel with constructing the houses, installing instrumentation, and monitoring performance for a year. Several detailed numerical models for FHX were developed as part of the project. Essentially the project team was searching for an energy performance model accurate enough to achieve project objectives while also having sufficient computational efficiency for practical use in EnergyPlus. A 3-dimensional, dual-coordinate-system, finite-volume model satisfied these criteria and was included in the October 2011 EnergyPlus Version 7 public release after being validated against measured data.

15 GEOTHERMAL ENERGY↗

Newton trust-region methods with primary variable switching for simulating high temperature multiphase porous media flow

Coupling multiphase flow with energy transport due to high temperature heat sources introduces significant new challenges since boiling and condensation processes can lead to dry-out conditions with subsequent re-wetting. The transition between two-phase and single-phase behavior can require changes to the primary dependent variables adding discontinuities as well as extending constitutive nonlinear relations to extreme physical conditions. Practical simulations of large-scale engineered domains lead to Jacobian systems with a very large number of unknowns that must be solved efficiently using iterative methods in parallel on high-performance computers. Performance assessment of potential nuclear repositories, carbon sequestration sites and geothermal reservoirs can require numerous Monte-Carlo simulations to explore uncertainty in material properties, boundary conditions, and failure scenarios. Due to the numerical challenges, standard NR iteration may not converge over the range of required simulations and require more sophisticated optimization method like trust-region. In this study, we use the open-source simulator PFLOTRAN for the important practical problem of the safety assessment of future nuclear waste repositories in the U.S. DOE geologic disposal safety assessment Framework. The simulator applies the PETSc parallel framework and a backward Euler, finite volume discretization. We demonstrate failure of the conventional NR method and the success of trust-region modifications to Newton’s method for a series of test problems of increasing complexity. Trust-region methods essentially modify the Newton step size and direction under some circumstances where the standard NR iteration can cause the solution to diverge or oscillate. Furthermore, we show how the Newton Trust-Region method can be adapted for Primary Variable Switching (PVS) when the multiphase state changes due to boiling or condensation. The simulations with high-temperature heat sources which led to extreme nonlinear processes with many state changes in the domain did not converge with NR, but they do complete successfully with the trust-region methods modified for PVS. This implementation effectively decreased weeks of simulation time needing manual adjustments to complete a simulation down to a day. Finally, we show the strong scalability of the methods on a single node and multiple nodes in an HPC cluster.

54 ENVIRONMENTAL SCIENCES↗

Industry case studies: Finance

This article, the third in a series on the U.S. Department of Energy and IDEA collaboration, focuses on financial strategies used by institutions to support district energy system modernization and decarbonization. It highlights how effective funding models, long-term cost analysis, and leadership support are critical to implementing large-scale infrastructure upgrades. The case studies show different approaches to financing. Ball State University demonstrates how life-cycle cost analysis and phased funding—supported by state funding, bonds, and grants—enabled a transition to geothermal energy. Penn State’s Hershey Medical Center emphasizes the importance of financial leadership, shifting from reactive budgeting to data-driven, proactive investment in infrastructure. The University of Washington highlights how comprehensive data collection and analytics can justify investments and even create self-sustaining funding mechanisms like green revolving funds. Overall, the article shows that combining strong financial planning, data-driven decision-making, and innovative funding approaches is essential for advancing sustainable district energy systems while managing high upfront costs.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

National Geothermal Database

THE NGDS IS A USER-FRIENDLY, WEB-BASED APPLICATION TO SUPPORT FINDING, VISUALIZING, MAPPING, AND ACQUISITION OF DATA BY END-USERS. THIS APPLICATION ALLOWS USERS TO DISCOVER AND ACCESS RESOURCES MADE AVAILABLE ACROSS ALL NGDS NODES, AND TO SEARCH FOR DATA ACROSS THE SYSTEM BASED ON TOPIC, LOCATION, AND OR OTHER CRITERIA. STANDARDIZED METADATA DESCRIBING EACH DATASET PROVIDES THE USER WITH THE INFORMATION NECESSARY TO DETERMINE THE UTILITY OF THAT DATASET FOR THEIR PURPOSES. GEOGRAPHIC DATASETS CAN BE VISUALIZED THROUGH A MAP INTERFACE THAT ALLOWS USERS TO INSPECT THE DETAILS OF INDIVIDUAL DATA POINTS (E.G. WELLS, TEMPERATURE MEASUREMENTS, ETC.) FROM PROPERLY FORMATTED DATASETS. IN ADDITION TO VISUALIZATION WITHIN THE APPLICATION, THE INTERFACE PROVIDES THE INFORMATION NECESSARY FOR USERS TO ACCESS THE DATA FROM OTHER APPLICATIONS.

Source record↗

National Geothermal Database

THE NGDS IS A USER-FRIENDLY, WEB-BASED APPLICATION TO SUPPORT FINDING, VISUALIZING, MAPPING, AND ACQUISITION OF DATA BY END-USERS. THIS APPLICATION ALLOWS USERS TO DISCOVER AND ACCESS RESOURCES MADE AVAILABLE ACROSS ALL NGDS NODES, AND TO SEARCH FOR DATA ACROSS THE SYSTEM BASED ON TOPIC, LOCATION, AND OR OTHER CRITERIA. STANDARDIZED METADATA DESCRIBING EACH DATASET PROVIDES THE USER WITH THE INFORMATION NECESSARY TO DETERMINE THE UTILITY OF THAT DATASET FOR THEIR PURPOSES. GEOGRAPHIC DATASETS CAN BE VISUALIZED THROUGH A MAP INTERFACE THAT ALLOWS USERS TO INSPECT THE DETAILS OF INDIVIDUAL DATA POINTS (E.G. WELLS, TEMPERATURE MEASUREMENTS, ETC.) FROM PROPERLY FORMATTED DATASETS. IN ADDITION TO VISUALIZATION WITHIN THE APPLICATION, THE INTERFACE PROVIDES THE INFORMATION NECESSARY FOR USERS TO ACCESS THE DATA FROM OTHER APPLICATIONS.

Source record↗

Chapter 11: Marine and Hydrokinetic Power Generation and Power Plants

Marine and hydrokinetic (MHK) power generation is a relatively new type of renewable generation. Predecessors such as wind power generation, hydropower plant generation, geothermal generation, photovoltaic generation, and solar thermal generation have gained a lot of attention because of their successful implementation. The successful integration of renewable generation into the electric power grid has energized the power system global communities to take the lessons learned, innovations, and market structure to focus on the large potential of MHK to also contribute to the pool of renewable energy generation. This chapter covers the broad spectrum of MHK generation. The state-of-the-art power takeoff methods will be discussed. Types of electrical generators will be presented, and the options for implementation will be presented.

16 TIDAL AND WAVE POWER↗

Ground Source Heat Pump Screening Tool and Related Resources

This archive contains both a link to Oak Ridge National Laboratory's Ground Source Heat Pump (GSHP) Screening Tool and related resources documenting its development, technical features, and applications. The web-based screening tool is a techno-economic analysis resource designed to evaluate the feasibility, costs, and benefits of implementing GSHP systems in buildings across various U.S. climate zones. It is intended for use by building owners, HVAC system designers, and installers to support decision-making in residential and commercial applications, incorporating advanced modeling capabilities such as ground heat exchanger design. The included resources detail the tool's creation and use, covering topics such as innovative ground heat exchanger design methodologies, the development of an open library of g-functions for borehole configurations, and studies on GSHP performance and economic viability in retrofitting single-family homes.

15 GEOTHERMAL ENERGY↗

Building America Case Study: Simplified Air Distribution, Desuperheaters, and Sub-Slab Geothermal Heat Exchangers, Pittsburgh, Pennsylvania

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab.

Building America↗

Building America Case Study: Simplified Air Distribution, Desuperheaters, and Sub-Slab Geothermal Heat Exchangers, Pittsburgh, Pennsylvania

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine-learning-assisted high-temperature reservoir thermal energy storage optimization

High-temperature reservoir thermal energy storage (HT-RTES) has the potential to become an indispensable component in achieving the goal of the net-zero carbon economy, given its capability to balance the intermittent nature of renewable energy generation. In this study, a machine-learning-assisted computational framework is presented to co-optimize the performance metrics of HT-RTES by combining physics-based simulation with stochastic hydrogeologic formation and thermal energy storage operation parameters, artificial neural network regression of the simulation data, and genetic algorithm-enabled multi-objective optimization. A doublet well configuration with a layered (aquitard-aquifer-aquitard) generic reservoir is simulated for cases of continuous operation and seasonal-cycle operation scenarios. Further, neural network-based surrogate models are developed for the two scenarios and applied to generate the Pareto fronts of the HT-RTES performance for four potential HT-RTES sites. The developed Pareto optimal solutions indicate the performance of HT-RTES is operation-scenario (i.e., fluid cycle) and reservoir-site dependent, and the performance metrics have competing effects for a given site and a given fluid cycle. The developed neural network models can be applied to identify suitable sites for HT-RTES, and the proposed framework sheds light on the design of resilient HT-RTES systems.

15 GEOTHERMAL ENERGY↗

Hydroshear Simulation Lab Test 2

This data file is for test 2. In this test a sample of granite with a pre-cut (man made fracture) is confined, heated and differential stress is applied. The max temperature in this this system development test is 95C. More test details can be found on the spreadsheets--note that there are 2 spreadsheets

15 GEOTHERMAL ENERGY↗

Daemen Alternative Energy/Geothermal Technologies Demonstration Program Erie County

The purpose of the Daemen Alternative Energy/Geothermal Technologies Demonstration Project is to demonstrate the use of geothermal technology as model for energy and environmental efficiency in heating and cooling older, highly inefficient buildings. The former Marian Library building at Daemen College is a 19,000 square foot building located in the center of campus. Through this project, the building was equipped with geothermal technology and results were disseminated. Gold LEED certification for the building was awarded. 1) How the research adds to the understanding of the area investigated. This project is primarily a demonstration project. Information about the installation is available to other companies, organizations, and higher education institutions that may be interested in using geothermal energy for heating and cooling older buildings. 2) The technical effectiveness and economic feasibility of the methods or techniques investigated or demonstrated. According to the modeling and estimates through Stantec, the energy-efficiency cost savings is estimated at 20%, or $24,000 per year. Over 20 years this represents $480,000 in unrestricted revenue available for College operations. See attached technical assistance report. 3) How the project is otherwise of benefit to the public. The Daemen College Geothermal Technologies Ground Source Heat Pumps project sets a standard for retrofitting older, highly inefficient, energy wasting and environmentally irresponsible buildings quite typical of many of the buildings on the campuses of regional colleges and universities. As a model, the project serves as an energy-efficient system with significant environmental advantages. Information about the energy-efficiency measures is available to other colleges and universities, organizations and companies, students, and other interested parties. The installation and renovation provided employment for 120 individuals during the award period. Through the new Center, Daemen will continue to host a range of events on campus for the general public. The College does not charge fees for speakers or most other events. This has been a long-standing tradition of the College.

15 GEOTHERMAL ENERGY↗