Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAIN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Experimental Studies of Particle Acceleration and Heating During Magnetic Reconnection

Energy conversion from magnetic energy to particle energy during magnetic reconnection is studied in the collisionless plasma of the Magnetic Reconnection Experiment (MRX). The plasma is in the two-fluid regime, where the ion motion is decoupled from that of the electron within the so-called ion diffusion region. For ion heating and acceleration, the role of the in-plane (Hall) electric field is emphasized. The in-plane potential responsible for the Hall electric field is established by electrons that are accelerated near the small electron diffusion region. The in-plane electrostatic potential profile shows a well structure along the direction normal to the reconnection current sheet that becomes deeper and wider downstream as its boundary expands along the separatrices where the in-plane electric field is strongest. Since the Hall electric field is 3--4 times larger than the reconnection electric field, unmagnetized ions obtain energy mostly from the in-plane electric field, especially near the separatrices. The Hall electric field ballistically accelerates ions near the separatrices toward the outflow direction. After ions are accelerated, they are heated as they travel into the high pressure downstream region. This downstream ion heating cannot be explained by classical, unmagnetized transport theory, which suggests that the magnetic field should be important due to an effect called re-magnetization. Electrons are also significantly heated during reconnection. The electron temperature sharply increases across the separatrices and peaks just outside of the electron diffusion region. Unlike ions, electrons acquire energy mostly from the reconnection electric field and the energy gain is localized near the X-point. However, the electron bulk flow energy increase remains negligible. These observations support the assertion that efficient electron heating mechanisms exist around the electron diffusion region and that the generated heat is quickly transported along the magnetic field due to the high parallel thermal conductivity of electrons. Classical Ohmic dissipation based on the perpendicular Spitzer resistivity is too small to compensate the heat flux, indicating the presence of anomalous electron heating. Finally, a total energy inventory is calculated based on analysis of the Poynting, enthalpy, flow energy, and heat flux in the measured diffusion layer. More than half of the incoming magnetic energy is converted to particle energy during collisionless reconnection. Unlike in the Sweet-Parker model, the outgoing Poynting flux is not negligible, which is due to considerable Hall fields, i.e., the quadrupole out-of-plane magnetic field and the in-plane electric field. The total ion energy gain during reconnection is larger than that of electrons, since the energy gain occurs over a broader region. The total ion thermal energy gain is larger than the increase of the ion flow energy. Finally, the electron thermal energy gain is comparable to the ion thermal energy gain, while the electron flow energy remains insignificant.

electron heating↗

32 Channel × 40 Gb/s WDM optical communication system utilizing different configurations of hybrid fiber amplifier

In this paper, a simulation analysis of 40 Gb/s wavelength division multiplexing system of 32 channels is implemented through RZ modulation format by using a different hybrid fiber amplifier (HFA) configurations, namely, serial HFA, parallel HFA, and combined serial–parallel hybrid fiber amplifier (CSP-HFA). The performance of the proposed amplifiers is compared in terms of average gain level, average noise figure, flat gain bandwidth. In addition, quality factor, bit error rate, and eye diagram for the demonstrated 32 channel × 40 Gb/s wavelength division multiplexing optical communication system utilizing different configurations of the hybrid fiber amplifier is compared. The CSP-HFA shows better performance than serial and parallel hybrid amplifiers in terms of wider flat gain bandwidth, higher quality factor, lower bit error rate, and wider and clearer eye opening. Furthermore, CSP-HFA exhibits a flat gain bandwidth of 65 nm with an acceptable average gain of 16 dB and average noise figure of 7 dB.

42 ENGINEERING↗

Concatenated analyses of phase space microbunching in high brightness electron beam transport

Microbunching instability (MBI) has been a challenging issue in high-brightness electron beam transport for modern accelerators. The existing theoretical formulation of MBI for recirculating accelerators is based on the single-pass analysis. For multi-pass recirculation or a long beam transport line, the intuitive way of quantifying MBI by successive multiplication of individual scalar amplification gains from subsections of a beamline was found to underestimate the effect. More thorough analyses based on concatenation of gain matrices, aimed to combine the density, energy, and transverse–longitudinal modulations for a general linear transport line, will be developed in this paper. Inclusion of such cross-plane microbunching structures in semi-analytical Vlasov analysis is a crucial step to systematically characterize phase space modulations for a beamline complex in terms of concatenating individual beamline segments. In this paper we outline the concept of gain matrix and develop a semi-analytical formulation to include the microbunching structures in the aforementioned phase space modulations. Moreover we investigate the phase space microbunching dynamics in an example lattice of the recirculating beamline, compare the semi-analytical calculation with particle tracking simulations, and find that the microbunching amplification calculated from multiplication of concatenated gain matrices can be considered as upper limit to the start-to-end gains.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulations of High-speed, Time-gated MCP-based X-ray Detectors: Saturation Effects in DC and Pulsed Modes and Detector Dynamic Range

We present here results of continued efforts to understand the performance of microchannel plate (MCP)–based, high-speed, gated, x-ray detectors. This work involves the continued improvement of a Monte Carlo simulation code to describe MCP performance coupled with experimental efforts to better characterize such detectors. Our goal is a quantitative description of MCP saturation behavior in both static and pulsed modes. We have developed a new model of charge buildup on the walls of the MCP channels and measured its effect on MCP gain. The results are compared to experimental data obtained with a short-pulse, high-intensity ultraviolet laser; these results clearly demonstrate MCP saturation behavior in both DC and pulsed modes. The simulations compare favorably to the experimental results. The dynamic range of the detectors in pulsed operation is of particular interest when fielding an MCP–based camera. By adjusting the laser flux we study the linear range of the camera. These results, too, are compared to our simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carrier dynamics in inhomogeneously broadened InAs/AlGaInAs/InP quantum-dot semiconductor optical amplifiers

We report on a characterization of fundamental gain dynamics in recently developed InAs/InP quantum-dot semiconductor optical amplifiers. Multi-wavelength pump-probe measurements were used to determine gain recovery rates, following a powerful optical pump pulse, at various wavelengths for different bias levels and pump excitation powers. The recovery was dominated by coupling between the electronic states in the quantum-dots and the high energy carrier reservoir via capture and escape mechanisms. These processes determine also the wavelength dependencies of gain saturation depth and the asymptotic gain recovery level. Unlike quantum-dash amplifiers, these quantum-dots exhibit no instantaneous gain response, confirming their quasi zero-dimensional nature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Envelope matching for enhanced backward Raman amplification by using self-ionizing plasmas

Backward Raman amplification (BRA) in plasmas has been promoted as a means for generating ultrapowerful laser pulses. For the purpose of achieving the maximum intensities over the shortest distances, an envelope matching between the seed pulse and the amplification gain is required, i.e., the seed pulse propagates at the same velocity with the gain such that the peak of the seed pulse can always enjoy the maximum gain. However, such an envelope matching is absent in traditional BRA because in the latter the amplification gain propagates at superluminous velocity while the seed pulse propagates at the group velocity, which is less than the speed of light. It is shown here that, by using self-ionizing plasmas, the speed of the amplification gain can be well reduced to reach the envelope matching regime. This results in a favorable BRA process, in which higher saturated intensity, shorter interaction length and higher energy-transfer efficiency are achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ignition design space of magnetized target fusion

The simple magnetized target implosion model of Lindemuth and Kirkpatrick [Nucl. Fusion 23, 263 (1983)] has been extended to survey the potential parameter space in which three types of magnetized targets—cylindrical with axial magnetic field, cylindrical with azimuthal magnetic field, and spherical with azimuthal magnetic field—might achieve ignition and produce large gain at achievable radial convergence ratios. The model has been used to compute the dynamic, time-dependent behavior of many initial parameter sets that have been based upon projected ignition conditions using the quasi-adiabatic and quasi-flux-conserving properties of magnetized target implosions. The time-dependent calculations have shown that energy gains greater than 30 can potentially be achieved for each type of target. By example, it is shown that high gain may be obtained at extremely low convergence ratios, e.g., less than 15, for appropriate initial conditions. It is also shown that reaching the ignition condition, i.e., when fusion deposition rates equal total loss rates, does not necessarily lead to high gain and high fuel burn-up. At the lower densities whereby fusion temperatures can be reached in magnetized targets, the fusion burn rate may be only comparable with the hydrodynamic heating/cooling rates. On the other hand, when the fusion burn rates significantly exceed the hydrodynamic rates, the calculations show a characteristic rapid increase in temperature due to alpha particle deposition with a subsequent increased burn rate and high gain. A major result of this paper is that each type of target operates in a different initial density-energy-velocity range. The results of this paper provide initial target plasma parameters and driver parameters that can be used to guide plasma formation and driver development for magnetized targets. The results indicate that plasmas for spherical, cylindrical with azimuthal field, and cylindrical with axial field targets must have an initial density greater than approximately 10{sup 17}/cm{sup 3}, 10{sup 18}/cm{sup 3}, and 10{sup 20}/cm{sup 3}, respectively, implying constraints on target plasma formation research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10{sup 4} photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm{sup 2} pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm{sup 2}. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Table-top two-color soft X-ray laser by means of Ni-like plasmas

Laser-produced Ni-like plasmas are known as active media for extreme ultraviolet lasing, with the flexibility to two-color lasing. Two-color laser generation is very complex at accelerator facilities. In this work, plasma lasing at the 3d{sup 9}4d{sup 1}(J = 0) → 3d{sup 9}4p{sup 1}(J = 1) (collisional-pumping process) and the 3d{sup 9}4f{sup 1}(J = 1) → 3d{sup 9}4d{sup 1}(J = 1) (photo-pumping process) transitions is studied experimentally and computationally. Several key characteristics of collisional- and photo-pumping laser, such as divergence, pointing stability, and intensity have been investigated. The measurements showed different pulse characteristics for the two lasing processes affected by plasma inhomogeneity in temperature and density. Analytical expressions of these characteristics for both collisional- and photo-pumping are derived. It is found that the plasma that maximizes the photo-pumping lasing is 20% hotter and 70% denser than the plasma that optimizes the collisional-pumping lasing. The gain of collisional pumping is ≈4 times higher than the gain for the photo-pumping. The gain lifetime is a factor of ≈5.2 larger for the monopole-pumping. Similarly, the gain thickness is a factor of ≈1.8 larger. It is also found that the gain build-up time for collisional- and photo-pumping is 0.7 ps and 0.9 ps, respectively, whereas the build-up length-scale is 11.5 μm and 6.3 μm, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two‐Color Amplified Spontaneous Emission from Auger‐Suppressed Quantum Dots in Liquids

Abstract Colloidal quantum‐dot (QD) lasing is normally achieved in close‐packed solid‐state films, as a high QD volume fraction is required for stimulated emission to outcompete fast Auger decay of optical‐gain‐active multiexciton states. Here a new type of liquid optical‐gain medium is demonstrated, in which compact compositionally‐graded QDs (ccg‐QDs) that feature strong suppression of Auger decay are liquefied using a small amount of solvent. Transient absorption measurements of ccg‐QD liquid suspensions reveal broad‐band optical gain spanning a wide spectral range from 560 (green) to 675 nm (red). The gain magnitude is sufficient to realize a two‐color amplified spontaneous emission (ASE) at 637 and 594 nm due to the band‐edge (1S) and the excited‐state (1P) transition, respectively. Importantly, the ASE regime is achieved using quasicontinuous excitation with nanosecond pulses. Furthermore, the ASE is highly stable under prolonged excitation, which stands in contrast to traditional dyes that exhibit strong degradation under identical excitation conditions. These observations point toward a considerable potential of high‐density ccg‐QD suspensions as liquid, dye‐like optical gain media that feature readily achievable spectral tunability and stable operation under intense photoexcitation.

Li, Xueyang↗

CheKiPEUQ Intro 2: Harnessing Uncertainties from Data Sets, Bayesian Design of Experiments in Chemical Kinetics**

When choosing experimental conditions, Bayesian statistical tools can predict the experimental choices which will yield the highest information gain. Experimental choices could be temperature, pressure, reaction time, number of measurements, reactor volume, etc.. Three example analyses are presented here, each using the software Chemical Kinetics Parameter Estimation and Uncertainty Quantification (CheKiPEUQ). Information gain is a measure of reduction of uncertainty in a model's parameters. The three chemical system examples presented each illustrate Bayesian Design of Experiments using information gain. In the first chemical example, temperature selection impacts the information gain for the free energy of reaction in a two-component equilibrium reaction. In the second example, temperature and pressure are explored for a competitive adsorption Langmuir replacement reaction system. Finally, the third example is a catalytic membrane reactor which is a culmination of the previous examples. The catalytic membrane reactor has a complex and nonlinear response in the observables which is solved by numerical evaluation. In the three examples, the experimental conditions are treated as design variables for maximizing information gain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bio-inspired alula-based winglet design for enhanced heat transfer in high temperature fin-and-tube heat exchangers

Fin-and-tube heat exchangers (FTHEs) are widely used for high-temperature flue-gas heat recovery, but their performance is often limited by wake regions and non-uniform fin-surface temperatures. This study proposes and numerically evaluates four bio-inspired longitudinal vortex generator (VG) configurations in a high-temperature FTHE with flue-gas inlet temperature ∼1230 K: double-delta, curved double-delta, alula, and a new curved-alula geometry. The reference fin is not hydraulically plain; it already incorporates leading-edge separation columns and convex protrusions, so the alula-type winglets are assessed as downstream add-ons acting on a strongly disturbed flow. In a second step, perforations (one, two and three circular holes) are introduced into the curved-alula VGs to further tailor the flow field. Three-dimensional simulations with the Shear Stress Transpor (SST) $k - ω$ model, temperature-dependent flue-gas properties and conjugate conduction are carried out for gas-side Reynolds numbers $Re_g ≈ 8.0$ x $10^2 - 3.6$ x $10^3$ (mass flow rates 0.5 – 2.5 g/s), and the designs are compared in terms of surface heat flux, Nusselt number, friction factor and hydrothermal performance factor (HTPF). For this already-promoted fin, the additional downstream winglets provide moderate, incremental hydrothermal gains. At the highest Reynolds number, the best non-perforated design (curved-alula) increases surface heat flux from 1630.9 to 1794.7 kW/m² (∼ 10 % gain) and the Nusselt number from 227.6 to 242.6 (∼ 7 % gain), while the friction factor rises from 0.26 to about 0.30, yielding HTPF values close to unity (∼ 0.9 – 1.0). Introducing circular perforations into the curved-alula winglets acts mainly as a wake-bleeding refinement: the three-hole configuration provides a heat flux of 1824.7 kW/m² and a pressure drop of 127.9 Pa, with HTPF in the range ∼ 1.03 – 1.14 and a small (∼ 1 – 3 %) improvement over the solid curved-alula design. Flow-field analysis shows that the perforated curved-alula VGs shrink tube-wake regions, thin the thermal boundary layer and homogenize the fin-surface temperature (outlet-gas temperature ∼ 510 – 520 K and fin-surface temperature ∼ 420 – 421 K for the three-hole case). An optimal flue-gas mass flow rate of ∼ 1 g/s ($Re_g ≈ 1.5$ x $10^3$) is identified, beyond which additional heat-transfer gains are offset by rapidly increasing pressure losses. Overall, the results highlight that initial fin geometry and VG placement are as important as VG shape: alula-based winglets are expected to yield larger relative gains on simpler flat-fin layouts or when positioned closer to the fin leading edge and tube

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Individualized Dose Prescription for Hypofractionation in Advanced Non-Small-Cell Lung Cancer Radiotherapy: An in silico Trial

Purpose: Local tumor control and outcome remain poor in patients with advanced non-small-cell lung cancer (NSCLC) treated by external beam radiotherapy. We investigated the therapeutic gain of individualized dose prescription with dose escalation based on normal tissue dose constraints for various hypofractionation schemes delivered with intensity-modulated radiation therapy. Methods and Materials: For 38 Stage III NSCLC patients, the dose level of an existing curative treatment plan with standard fractionation (66 Gy) was rescaled based on dose constraints for the lung, spinal cord, esophagus, brachial plexus, and heart. The effect on tumor total dose (TTD) and biologic tumor effective dose in 2-Gy fractions (TED) corrected for overall treatment time (OTT) was compared for isotoxic and maximally tolerable schemes given in 15, 20, and 33 fractions. Rescaling was accomplished by altering the dose per fraction and/or the number of fractions while keeping the relative dose distribution of the original treatment plan. Results: For 30 of the 38 patients, dose escalation by individualized hypofractionation yielded therapeutic gain. For the maximally tolerable dose scheme in 33 fractions (MTD{sub 33}), individualized dose escalation resulted in a 2.5-21% gain in TTD. In the isotoxic schemes, the number of fractions could be reduced with a marginal increase in TED. For the maximally tolerable dose schemes, the TED could be escalated up to 36.6%, and for all patients beyond the level of the isotoxic and the MTD{sub 33} schemes (range, 3.3-36.6%). Reduction of the OTT contributed to the therapeutic gain of the shortened schemes. For the maximally tolerable schemes, the maximum esophageal dose was the dominant dose-limiting constraint in most patients. Conclusions: This modeling study showed that individualized dose prescription for hypofractionation in NSCLC radiotherapy, based on scaling of existing treatment plans up to normal tissue dose constraints, enables dose escalation with therapeutic gain in 79% of the cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Single Fraction of Stereotactic Body Radiation Therapy Compared With Single Fraction of External Beam Radiation Therapy for Palliation of Vertebral Bone Metastases

Purpose: Stereotactic body radiation therapy (SBRT) has been proposed for the palliation of painful vertebral bone metastases because higher radiation doses may result in superior and more durable pain control. A phase III clinical trial (Radiation Therapy Oncology Group 0631) comparing single fraction SBRT with single fraction external beam radiation therapy (EBRT) in palliative treatment of painful vertebral bone metastases is now ongoing. We performed a cost-effectiveness analysis to compare these strategies. Methods and Materials: A Markov model, using a 1-month cycle over a lifetime horizon, was developed to compare the cost-effectiveness of SBRT (16 or 18 Gy in 1 fraction) with that of 8 Gy in 1 fraction of EBRT. Transition probabilities, quality of life utilities, and costs associated with SBRT and EBRT were captured in the model. Costs were based on Medicare reimbursement in 2014. Strategies were compared using the incremental cost-effectiveness ratio (ICER), and effectiveness was measured in quality-adjusted life years (QALYs). To account for uncertainty, 1-way, 2-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay (WTP) threshold of $100,000 per QALY gained. Results: Base case pain relief after the treatment was assumed as 20% higher in SBRT. Base case treatment costs for SBRT and EBRT were $9000 and $1087, respectively. In the base case analysis, SBRT resulted in an ICER of $124,552 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of the utility of unrelieved pain; the utility of relieved pain after initial treatment and median survival were also sensitive to variation. If median survival is ≥11 months, SBRT cost <$100,000 per QALY gained. Conclusion: SBRT for palliation of vertebral bone metastases is not cost-effective compared with EBRT at a $100,000 per QALY gained WTP threshold. However, if median survival is ≥11 months, SBRT costs ≤$100,000 per QALY gained, suggesting that selective SBRT use in patients with longer expected survival may be the most cost-effective approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cost-Effectiveness Analysis of Stereotactic Body Radiation Therapy Compared With Radiofrequency Ablation for Inoperable Colorectal Liver Metastases

Purpose: To conduct a cost-effectiveness analysis to determine whether stereotactic body radiation therapy (SBRT) is a cost-effective therapy compared with radiofrequency ablation (RFA) for patients with unresectable colorectal cancer (CRC) liver metastases. Methods and Materials: A cost-effectiveness analysis was conducted using a Markov model and 1-month cycle over a lifetime horizon. Transition probabilities, quality of life utilities, and costs associated with SBRT and RFA were captured in the model on the basis of a comprehensive literature review and Medicare reimbursements in 2014. Strategies were compared using the incremental cost-effectiveness ratio, with effectiveness measured in quality-adjusted life years (QALYs). To account for model uncertainty, 1-way and probabilistic sensitivity analyses were performed. Strategies were evaluated with a willingness-to-pay threshold of $100,000 per QALY gained. Results: In base case analysis, treatment costs for 3 fractions of SBRT and 1 RFA procedure were $13,000 and $4397, respectively. Median survival was assumed the same for both strategies (25 months). The SBRT costs $8202 more than RFA while gaining 0.05 QALYs, resulting in an incremental cost-effectiveness ratio of $164,660 per QALY gained. In 1-way sensitivity analyses, results were most sensitive to variation of median survival from both treatments. Stereotactic body radiation therapy was economically reasonable if better survival was presumed (>1 month gain) or if used for large tumors (>4 cm). Conclusions: If equal survival is assumed, SBRT is not cost-effective compared with RFA for inoperable colorectal liver metastases. However, if better local control leads to small survival gains with SBRT, this strategy becomes cost-effective. Ideally, these results should be confirmed with prospective comparative data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗