Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Factorization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

The Use of a Multichannel Analyzer to Investigate Effects of Experimental Factors on Gross-Counting Gamma and Neutron Detectors

Radiation detection technology is invaluable to many fields of study in identifying nuclear materials. However, many detectors use gross-counting methods that give only a relative count rate. Without a spectrum (information on counts over time vs energy), it can be more difficult to discern if an alarm is false, innocent, or real. In particular, we would like to understand better the effect of experimental factors (i.e., external conditions and equipment parameters) on detector data, with possible implications for false alarms. To more thoroughly characterize detector technology, a multichannel analyzer (MCA) was used to record spectra from neutron (helium-3 tubes) and gamma (photomultiplier tubes) gross-counting detectors. Several factors could affect the signal-to-noise ratio of sources. For example, we examined the effects of neutron detector high voltage setting on the appearance of a californium-252 spectrum, the effect of discriminator values on integrated counts in neutron detection, and the effect of gain changes on the gamma spectra from several sources. Possible implications of ambient temperature of the experiment on the data collected will be discussed. The input impedance of the MCA must be considered to ensure that data are not affected by the measurement itself. Moreover, a calibration on the MCA was performed to verify the conversion of a MCA channel number to a voltage. In summary, the series of source spectra collected on an MCA with a variety of experimental conditions allow us to understand factors that affect data better, and assure us that gross-counting neutron and gamma detectors will have minimal false alarms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-factor authentication

Detection and deterrence of spoofing of user authentication may be achieved by including a cryptographic fingerprint unit within a hardware device for authenticating a user of the hardware device. The cryptographic fingerprint unit includes an internal physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a PUF value. Combining logic is coupled to receive the PUF value, combines the PUF value with one or more other authentication factors to generate a multi-factor authentication value. A key generator is coupled to generate a private key and a public key based on the multi-factor authentication value while a decryptor is coupled to receive an authentication challenge posed to the hardware device and encrypted with the public key and coupled to output a response to the authentication challenge decrypted with the private key.

97 MATHEMATICS AND COMPUTING↗

ROLE OF SCALE FACTOR DURING TENSILE TESTING OF SMALL SPECIMENS

The influence of scale factor (tensile specimen geometry and dimensions) on mechanical test results was investigated for different widely used types of small specimens (SS-1, SS-2, SS-3, and SS-J3) and a set of materials. It was found that the effect of scale factor on the accurate determination of yield stress, ultimate tensile stress, and uniform elongation values was weak; however, clear systematic differences were observed and should be accounted for during interpretation of results. In contrast, total elongation values were strongly sensitive to variations in specimen geometry. Modern experimental methods like digital image correlation allow the impact of scale factor to be reduced. Using these techniques, it was shown that true stress true strain curves describing strain-hardening behavior were very close for different specimen types. The limits of miniaturization are discussed, and an ultra-miniature specimen concept was suggested and evaluated. This type of specimen, as expected, may be suitable for SEM and TEM in situ testing.

Gussev, Maxim N↗

Energy Factor Analysis for Gas Heat Pump Water Heaters

Gas heat pump water heaters (HPWHs) can improve water heating efficiency with zero GWP and zero ODP working fluids. The energy factor (EF) of a gas HPWH is sensitive to several factors. In this work, expressions are derived for EF of gas HPWHs, as a function of heat pump cycle COP, tank heat losses, burner efficiency, electrical draw, and effectiveness of supplemental heat exchangers. The expressions are used to investigate the sensitivity of EF to each parameter. EF is evaluated on a site energy basis (as used by the US DOE for rating water heater EF), and a primary energy-basis energy factor (PEF) is also defined and included. Typical ranges of values for the six parameters are given. For gas HPWHs, using typical ranges for component performance, EF will be 59 80% of the heat pump cycle thermal COP (for example, a COP of 1.60 may result in an EF of 0.94 1.28). Most of the reduction in COP is due to burner efficiency and tank heat losses. Gas-fired HPWHs are theoretically be capable of an EF of up to 1.7 (PEF of 1.6); while an EF of 1.1 1.3 (PEF of 1.0 1.1) is expected from an early market entry.

Gluesenkamp, Kyle R↗

Kaon and D Meson Semileptonic Form Factors from Lattice QCD

We present the status of on-going calculations of the $K\to\pi l\nu$ and $D\to K(\pi) l\nu$ semileptonic form factors at $q^2=0$. These form factors are important for the determination of the CKM matrix elements $\lvert{V_{us}}\rvert$ and $\lvert{V_{cs(d)}}\rvert$ respectively. This work uses the HISQ action for both valence quarks and sea quarks on MILC $N_f=2+1+1$ configurations. We employ twisted boundary conditions to calculate the form factors at zero momentum transfer directly. The $K\to\pi$ results are an update to previously published results with new data at the physical point. The $D\to K(\pi)$ results are preliminary.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accessing the Elastic Form-Factors of the $Delta(1232)$ Using the Beam-Normal Asymmetry

The beam-normal single-spin asymmetry, $B_n$, exists in the scattering of high energy electrons, polarized transverse to their direction of motion, from nuclear targets. To first order, this asymmetry is caused by the interference of the one-photon exchange amplitude with the imaginary part of the two-photon exchange amplitude. Measurements of $B_n$, for the production of a $\Delta(1232)$ resonance from a proton target, will soon become available from the Qweak experiment at Jefferson Lab and the A4 experiment at Mainz. The imaginary part of two-photon exchange allows only intermediate states that are on-shell, including the $\Delta$ itself. Therefore such data is sensitive to $\gamma\Delta\Delta$, the elastic form-factors of the $\Delta$. This article will introduce the form-factors of the $\Delta$, discuss what might be learned about the elastic form-factors from these new data, describe ongoing efforts in calculation and measurement, and outline the possibility of future measurements.

Dalton, Mark M.↗

Achievement of Ultra-High Quality Factor in Prototype Cryomodule for LCLS-II

Quality factor is a primary cost driver for high energy, continuous wave (CW) SRF linacs like the LCLS-II X-ray free electron laser currently under construction. Taking this into account, several innovations were introduced in the LCLS-II cryomodule design to push substantially beyond the previous state-of-the-art quality factor achieved in operation. This includes the first ever implementation of the nitrogen doping cavity treatment, the capability to provide high mass flow cooldown to improve expulsion of magnetic flux based on recent R&D, high performance magnetic shielding, and other critical subcomponents. To evaluate the implementation of these new cryomodule features, two prototype cryomodules were produced. In this paper, we present results from the prototype cryomodule assembled at Fermilab, which achieved unprecedented cavity quality factors of 3.0e10 at a nominal cryomodule voltage. We overview cavity performance, procedures to achieve ambient magnetic field < 5 mG at the cavity wall, and the successful demonstration of high mass flow cooldown in a cryomodule. The cavity performance under various cool down conditions are presented as well to show the impact of flux expulsion on Q0.

43 PARTICLE ACCELERATORS↗

Determining Beta Radiation Protection Factors for Eye Shields

The purpose of this experiment was to determine the efficacy of INL eye shields in attenuating beta radiation and was performed in response to changes in international and national standards and guidelines. Two methods were used to determine the protection factor for each eye shield: A Fixed Evaluation and a Dosimetry Evaluation. Both evaluations showed the PAPR hood as the least protective eye shield and the respirator face mask as having the highest protection factor. Seven of the eye shields challenge the INL protection factor criteria of 3 and will require further testing. Though the two methods varied widely, the results were consistent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements toward refined methane emission factors from industrial and commercial natural gas meters

The methane emission factors used in the U.S. EPA Greenhouse Gas Inventory (GHGI) for several categories of equipment in the natural gas supply chain currently have large uncertainties. The purpose of this project was to focus on one of those categories, industrial/commercial customer meters. The potential effect of the uncertainty for this category could be large due to the 5.6 million meters nationwide. We divided the country into six regions and worked extensively with local natural gas distribution companies to gain access to the meters. Ten weeks of measurements were conducted with an additional three weeks spent later revisiting the first sites. Sites were selected pseudo-randomly, by first randomly selecting a location then driving to as many meters as possible during that day, then randomly selecting another starting meter for the next day. At each site, every component was scanned with a combustible gas indicator (CGI), all components were counted, and all leaks with indications above 100ppm were logged. For 3 of the 10 weeks of measurements all leaks above 100ppm were quantified and for the remaining seven only leaks with an indication concentration above 22,500 ppm (45% of lower explosive limit) were quantified. Leaks were quantified using an enclosure, a vacuum pump, and methane sensor (either a CGI or Los Gatos Research Greenhouse Gas Analyzer). Through the initial visits 18,934 components were scanned, resulting in 1,170 leak indications above 100ppm, 351 leaks quantified at 174 different meter sets. The data was collected in a way so that it could be stratified by region, meter type, and component type. The largest number of components scanned were valves (4908) and flanges (4571). Very preliminary analysis of the data indicates that the mean leak size (not by meter) by region was Southeast (0.78 ± 2.2 lpm) Southwest (0.63 ± 1.5 lpm), Rocky Mountain (0.54 ± 1.3 lpm) Northeast (0.14 ± 0.56 lpm), Midwest (0.14 ± 0.56 lpm), and Pacific (0.07 ± 0.56 lpm). We also have determined that of the component types logged, roughly 2 – 5% of all components leaked. Our results are only preliminary, but initial indications are that based on data from this study, the current emission factors could increase by a factor of 5 to 10. Data analysis is ongoing to verify.

03 NATURAL GAS↗

Numerical Simulation of Critical Factors Controlling Heat Extraction from Geothermal Systems Using a Closed-Loop Heat Exchange Method

Closed-loop heat exchange for geothermal energy production involves injecting working fluid down a well that extends through the geothermal resource over a significant length to absorb heat by conduction through the well pipe. The well then needs to return to the surface for energy recovery and fluid re-injection to complete the cycle. We have carried out mixed convective-conductive fluid-flow modeling using a wellbore flow model for TOUGH2 called T2Well to investigate the critical factors that control closed-loop geothermal energy recovery. T2Well solves a mixed explicit-implicit set of momentum equations for flow in the pipe with full coupling to the implicit three-dimensional integral finite difference equations for Darcy flow in the porous medium. T2Well has the option of modeling conductive heat flow from the porous medium to the pipe by means of a semi-analytical solution which makes the computation very efficient because the porous medium does not have to be discretized. When the fully three-dimensional option is chosen, the porous medium is discretized and heat flow to the pipe is by conduction and convection, depending on reservoir permeability and other factors. Simulations of the closed-loop system for a variety of parameter values have been carried out to elucidate the heat recovery process. To the extent that convection may occur to aid in heat delivery to the pipe, the permeability of the geothermal reservoir, whether natural or stimulated, is an important property in heat extraction. The injection temperature and flow rate of the working fluid strongly control the ultimate energy recovery. Pipe diameter also plays a strong role in heat extraction, but is correlated with flow rate. Similarly, the choice of working fluid plays an important role, with water showing better heat extraction than CO2 for certain flow rates, while the CO2 has higher pressure at the production wellhead which can aid in surface energy recovery. In general, we find complex interactions between the critical factors that will require advanced computational approaches to fully optimize.

Oldenburg, Curtis↗

Assessment of Overmatched Filler (Alloy 617) to Improve Alloy 800H Stress Rupture Factors

Section III, Division 5 of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) specifies rules for elevated temperature nuclear reactors. Currently, only six metals are qualified in Section III, Division for construction of Class A metallic pressure boundary components for elevated-temperature service, one of these being Alloy 800H. There are only two permissible filler metals Alloy 800H is qualified to be welded with: Alloy A and Alloy 82. The stress rupture factors for these two filler metals are low near the maximum temperatures and service lives Alloy 800H is qualified for. This may preclude vendors from being able to use Alloy 800H for elevated-temperature nuclear construction. In this work, an overmatched filler metal, Alloy 617 is assessed to determine its potential to offer improved stress rupture factors. Scoping creep-rupture tests of cross-welds with Alloy 800H base metal and Alloy 617 filler metal were conducted. Preliminary results do not indicate that Alloy 617 will offer significantly improved stress rupture factors. Consequently, a matching filler metal, UTP A 2133, is now being investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraints on the electron-hole pair creation energy and Fano factor below 150 eV from Compton scattering in a Skipper-CCD

Fully-depleted thick silicon Skipper-charge-coupled devices (Skipper-CCDs) have achieved sub-electron read-out noise and are an important technology to probe neutrino and light dark matter interactions. However, the successful search for rare neutrino or dark-matter events requires the signal and all backgrounds to be fully characterized. In particular, a measurement of the electron-hole pair creation energy below 150 eV and the Fano factor are necessary for characterizing the dark matter and neutrino signals. Moreover, photons from background radiation may Compton scatter in the silicon bulk, producing events that can mimic a dark matter or neutrino signal. We present a measurement of the Compton spectrum using a Skipper-CCD and a $^{241}$Am source. With these data, we measure the electron-hole pair-creation energy to be $\left(3.71 \pm 0.08\right)$ eV at 130 K in the energy range between 99.3 eV and 150 eV. By measuring the widths of the steps at 99.3 eV and 150 eV in the Compton spectrum, we introduce a novel technique to measure the Fano factor, setting an upper limit of 0.31 at 90% C.L. These results prove the potential of Skipper-CCDs to characterize the Compton spectrum and to measure precisely the Fano factor and electron-hole pair creation energy below 150 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Fill Factor on Electro-slag Remelting Operations

Vacuum induction melting (VIM), electro-slag remelting (ESR) and vacuum arc remelting (VAR) are all techniques used to make high quality ingots of complex chemistries. In some cases, all three are used, e.g., alloys for aerospace applications and increasingly those for fossil power applications under extreme conditions. Electroslag remelting operation is a complicated endeavor, dependent upon several factors including operating current, voltage, and geometry. A research scale 440 lb capacity ESR furnace was used to melt low carbon steel (1018 steel) electrodes of different diameters using various melt rates. This was used to assess melt parameters and sidewall and other quality aspects of the product ingots. These observations were compared to results from ESR modeling using MeltFlow-ESR. It was found that fill factor had a significant impact on operating voltage while current had a significant impact on melt rate. Ultimately, a combination of fill factor and power gave the best prediction of melt rate during steady state.

Jablonski, Paul↗

Measurement of generalized from factors near the pion threshold in high Q2 region with CLAS

The recent development of experimental techniques allow us to study threshold pion production in high-energy experiments and particularly, electro-production with photon virtuality Q2 in a few GeV2 range. The experiments with fine energy resolution make a major step to come close to the production threshold to suppress the P-wave contribution (M1+). The recent prediction based on the Light-Cone Sum Rule (LCSR), one can calculate the hadron form factors in terms of distribution amplitudes that approach perturbative Quantum Chromo-Dynamics (pQCD) without other non-perturbative parameters in high energy regime. The extraction of the generalized form factors near the pion threshold are estimated by the S- wave multipole dominance in the LCSR framework. We extracted the generalized form factors for the first time in the exclusive channel ( ep?en?+) using CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. The kinematic ranges are from 2.05GeV2 to 4.5GeV2 for Q2 and 1.11GeV to 1.15GeV for the invariant mass range in the n?+ system.. Preliminary results will be presented and compared with the calculation from LCSR, MAID and multipole analysis.

Park, Kijun↗

Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Generation of Bondarenko F factors with MCNP5 for use in scale transport codes

Generally there are three methods of cross-section processing available when using the Scale computer code. They are NITAWL, BONAMI, and CENTRM, with CENTRM being the most common and accurate, but computationally expensive. In order to improve the accuracy of BONAMI (which uses the Bondarenko Method), new Bondarenko/F Factors were to be generated that will smooth out the current F Factors that are being generated using CENTRM. The case discussed here involves using a dedicated Monte Carlo code (MCNP5) to calculate the transport solution from which shielded cross-sections can be produced directly for the transport geometry/mesh. A simple program was created to parse and collect the tallied cross-sections from the MCNP output, which was fed into a modified CLAROL input (a module that replaces or adds data in an AMPX master library), which used the cross-sections obtained from MCNP to calculate new F-factors and update the SCALE library. This approach allows the use of other methods to generate the shielded cross-sections and for easy comparison to existing results. Initial proof-of-principle calculations were carried out for an various cases using various transport solvers, such as NEWT, KENO, and XSDRN, with BONAMI in SCALE. Poor results were obtained using cross-sections generated using infinite homogeneous cases, but good results were obtained by using pin cells in an infinite lattice. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Magnetic Form Factor GNM Measurement at High Q2 with CLAS12

The neutron magnetic form factor, GnM , is a fundamental quantity that describes how magnetic properties are distributed within a neutron. This measurement provides insights into the internal structure of the neutron. Furthermore, by measuring GnM alongside three other form factors (GnE , GpE , GpM ), we can test the predictions of Quantum Chromodynamics (QCD), which is the fundamental theory governing the strong force that binds quarks and gluons. Additionally, these measurements play a significant role in constraining Generalized Parton Distributions (GPDs) and contribute to determining the angular momentum of the quarks within nucleons. The GnM was measured using the ratio of quasi-elastic e ? n to e ? p scattering from a deuteron target. The measurement covered a range of four-momentum transfer squared, Q2, from 5 to 12 GeV2, using three different beam energies (10.2, 10.4, and 10.6 GeV). The data is compared with previous measurements and several theoretical models. The preliminary results reveal that Gn M exceeds the predictions of the standard dipole parametrization by 12-20%, based on RG-B pass1 data. It is expected that this deviation from the standard dipole parametrization will diminish as we transition to using RG-B pass2 data, aligning GnM more closely with the dipole form factor. The ongoing RG-B pass2 analysis in CLAS12 holds considerable promise for significant improvement. This enhancement is achievable through collaborative efforts aimed at refining tracking efficiency, momentum correction, calibration, and alignment.

Baashen, Lamya↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗