Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLAT PLATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Turbulence measurements in the boundary layer of a low-speed wind tunnel using laser velocimetry

Laser velocimeter measurements in an incompressible, turbulent boundary layer along the wall of a low-speed wind tunnel are presented. The laser data are compared with existing hot-wire anemometer measurements of a flat plate, incompressible, turbulent, boundary layer with zero pressure gradient. An argument is presented to explain why previous laser velocimeter measurements in zero pressure gradient, turbulent boundary layers have shown an unexpected decrease in turbulent shear stresses near the wall.

Schairer, E. T.↗

First results of a study on turbulent boundary layers in oscillating flow with a mean adverse pressure gradient

The development of a turbulent unsteady boundary layer with a mean pressure gradient strong enough to induce separation, in order to complete the extend results obtained for the flat plate configuration is presented. The longitudinal component of the velocity is measured using constant temperature hot wire anemometer. The region where negative velocities exist is investigated with a laser Doppler velocimeter system with BRAGG cells. The boundary layer responds by forced pulsation to the perturbation of potential flow. The unsteady effects observed are very important. The average location of the zero skin friction point moves periodically at the perturbation frequency. Average velocity profiles from different instants in the cycle are compared. The existence of a logarithmic region enables a simple calculation of the maximum phase shift of the velocity in the boundary layer. An attempt of calculation by an integral method of boundary layer development is presented, up to the point where reverse flow starts appearing.

Houdeville, R.↗

A theoretical analysis of simulated transonic boundary layers in cryogenic-nitrogen wind tunnels

A theoretical analysis was made to determine the real gas effects on simulation of transonic boundary layers in wind tunnels with cryogenic nitrogen as the test gas. The analysis included laminar and turbulent flat plate boundary layers and turbulent boundary layers on a two dimensional airfoil. The results indicate that boundary layers in such wind tunnels should not be substantially different from ideal gas boundary layers at standard conditions. At a pressure of 9.0 atm, two separate effects produce deviations of real gas values from ideal gas values which are in the opposite direction from deviations at 1.0 atm and are of the same insignificant order of magnitude. Results also show that nonadiabatic boundary layers should be adequately simulated if the enthalpy ratio is the correlating parameter rather than the temperature ratio.

Adcock, J. B.↗

Vorticity associated with multiple jets in a crossflow

Vortex patterns from multiple subsonic jets exiting perpendicularly through a flat plate into a subsonic crossflow were investigated. Tandem and transverse jet configurations were examined using a paddle wheel sensor to indicate the presence and relative magnitude of streamwise vorticity in the flow. Results are presented in the form of contour plots of rotational speed of the paddle wheel as measured in planes downstream from the jets and perpendicular to the crossflow. Well developed diffuse contrarotating vortices were observed for the configurations studied. The location and strength of these vortices depended on the multiple jet configuration and the distance downstream from the jets.

Braden, S.↗

Automated Array Assembly Task In-depth Study of Silicon Wafer Surface Texturizing

Several aspects of silicon wafer surface texturizing were studied. A low cost cleaning method that utilizes recycled Freon in an ultrasonic vapor degreaser to remove organic and inorganic contaminants from the surface of silicon wafers as received from silicon suppliers was investigated. The use of clean dry air and high throughout wafer batch drying techniques was shown to lower the cost of wafer drying. A two stage texturizing process was examined for suitability in large scale production. Also, an in-depth gettering study with the two stage texturizing process was performed for the enhancement of solar cell efficiency, minimization of current versus voltage curve dispersion, and improvement in process reproducibility. The 10% efficiency improvement goal was exceeded for the near term implementation of flat plate photovoltaic cost reduction.

Jones, G. T.↗

Solar energy system performance evaluation: Seasonal report for SEMCO, Loxahatchee, Florida

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis used is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system and the technical contributions to the definition of techniques and requirements solar energy system design are analyzed. The solar energy system was designed to supply domestic hot water for a family of four, single-family residences. It consists of two liquid flat plate collectors, single tank, controls, and transport lines.

Source record↗

Installation guidelines for solar heating system, single-family residence at New Castle, Pennsylvania

The solar heating system installer guidelines are presented for each subsystem. This single family residential heating system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: (1) liquid cooled flat plate collectors; (2) water storage tank; (3) passive solar-fired domestic water preheater; (4) electric hot water heater; (5) heat pump with electric backup; (6) solar hot water coil unit; (7) tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; (8) control system; and (9) air-cooled heat purge unit. Information is provided on the operating procedures, controls, caution requirements, and routine and schedule maintenance in the form of written descriptions, schematics, detail drawings, pictures, and manufacturer's component data.

Source record↗

Simulation study of a geometric shape factor technique for estimating earth-emitted radiant flux densities from wide-field-of-view radiation measurements

Geometric shape factors were computed and applied to satellite simulated irradiance measurements to estimate Earth emitted flux densities for global and zonal scales and for areas smaller than the detector field of view (FOV). Wide field of view flat plate detectors were emphasized, but spherical detectors were also studied. The radiation field was modeled after data from the Nimbus 2 and 3 satellites. At a satellite altitude of 600 km, zonal estimates were in error 1.0 to 1.2 percent and global estimates were in error less than 0.2 percent. Estimates with unrestricted field of view (UFOV) detectors were about the same for Lambertian and limb darkening radiation models. The opposite was found for restricted field of view detectors. The UFOV detectors are found to be poor estimators of flux density from the total FOV and are shown to be much better as estimators of flux density from a circle centered at the FOV with an area significantly smaller than that for the total FOV.

Weaver, W. L.↗

Numerical simulation of shear flows over wavy boundaries

The full time-dependent two dimensional Navier-Stokes equations are solved using spectral methods to achieve high spatial accuracy and high order time-splitting methods together with conformal mapping methods to allow simulation of flow over steep waves, including general turbulent Reynolds stresses. The programs are used to study the properties of laminar and turbulent flow over a flat plate and in various wavy geometries. Results are compared with both available theory and experiment. For laminar flow, good agreement is achieved. For turbulent flow, the agreement is less satisfactory and may be explained by the simplified turbulent modelling use in the calculations.

Orszag, S. A.↗

Solar energy system performance evaluation: Seasonal report for IBM System 2, Togus, Maine

The solar energy system, SIMS Prototype System 2, was designed to supply domestic hot water to single family residences. The system consists of flat plate collectors, silicone working fluid, storage tanks, pumps, heat exchanger, controls, and associated plumbing. The long term field performance of the installed system was analyzed and the results are described.

Source record↗

An automatic locating system for cloud-to-ground lightning

Automatic locating systems which respond to cloud to ground lightning and which discriminate against cloud discharges and background noise are described. Subsystems of the locating system, which include the direction finder and the position analyzer, are discussed. The direction finder senses the electromagnetic fields radiated by lightning on two orthogonal magnetic loop antennas and on a flat plate electric antenna. The position analyzer is a preprogrammed microcomputer system which automatically computes, maps, and records lightning locations in real time using data inputs from the direction finder. The use of the locating systems for wildfire management and fire weather forecasting is discussed.

Krider, E. P.↗

Solar process water heat for the IRIS images custom color photo lab

The solar facility located at a custom photo laboratory in Mill Valley, California is described. It was designed to provide 59 percent of the hot water requirements for developing photographic film and domestic hot water use. The design load is to provide 6 gallons of hot water per minute for 8 hours per working day at 100 F. It has 640 square feet of flat plate collectors and 360 gallons of hot water storage. The auxillary back up system is a conventional gas-fired water heater. Site and building description, subsystem description, as-built drawings, cost breakdown and analysis, performance analysis, lessons learned, and the operation and maintenance manual are presented.

Source record↗

Solar energy system performance evaluation: Seasonal report for fern, Tunkhannock, Pennsylvania

The operational and thermal performance of a variety of solar systems installed in operational test sites are described. The analysis is based on instrumented system data monitored and collected for at least one full season of operation. The long-term field performance of the installed system is reported, and technical contributions to the definition of techniques and requirements for solar energy system design are made. The solar energy system was designed to supply space heating and domestic hot water for single-family residences. The system consists of air flat plate collectors, storage tank, pumps, heat exchangers, associated plumbing, and controls.

Source record↗

Solar hot water system installed at Quality Inn, Key West, Florida

The solar energy hot water system installed in the Quality Inn, Key West, Florida, which consists of four buildings is described. Three buildings are low-rise, two-story buildings containing 100 rooms. The fourth is a four-story building with 48 rooms. The solar system was designed to provide approximately 50 percent of the energy required for the domestic hot water system. The solar system consists of approximately 1400 square feet of flat plate collector, two 500 gallon storage tanks, a circulating pump, and a controller. Operation of the system was begun in April 1978, and has continued to date with only three minor interruptions for pump repair. In the first year of operation, it was determined that the use of the solar facility resulted in forty percent fuel savings.

Source record↗

Solar heating system installed at Blakedale Professional Center, Greenwood, South Carolina

Information on the solar heating system installed at the Blakedale Professional Center, in Greenwood, South Carolina is presented. The information consists of site and building description, solar system description, performance evaluation, system problems and installation drawings. The solar system was designed to provide approximately 85 percent of the building's heating requirements. The system was installed concurrently with building construction and heats 4,440 square feet of the building. There are 954 square feet of liquid flat plate collectors that are proof-mounted and have a drain-down system to protect the collectors from freezing. A 5,000 gallon steel, polyurethane insulated tank buried underground provides storage. The system was fully instrumented for performance evaluation and integrated into the National Solar Data Network.

Source record↗

Calculation of skin-friction coefficients for low Reynolds number turbulent boundary layer flows

An analysis is presented of the reliability of various generally accepted empirical expressions for the prediction of the skin-friction coefficient C/sub f/ of turbulent boundary layers at low Reynolds numbers in zero-pressure-gradient flows on a smooth flat plate. The skin-friction coefficients predicted from these expressions were compared to the skin-friction coefficients of experimental profiles that were determined from a graphical method formulated from the law of the wall. These expressions are found to predict values that are consistently different than those obtained from the graphical method over the range 600 Re/sub theta 2000. A curve-fitted empirical relationship was developed from the present data and yields a better estimated value of C/sub f/ in this range. The data, covering the range 200 Re/sub theta 7000, provide insight into the nature of transitional flows. They show that fully developed turbulent boundary layers occur at Reynolds numbers Re/sub theta/ down to 425. Below this level there appears to be a well-ordered evolutionary process from the laminar to the turbulent profiles. These profiles clearly display the development of the turbulent core region and the shrinking of the laminar sublayer with increasing values of Re/sub theta/.

Barr, P. K.↗

Solar energy system performance evaluation: Seasonal report for Decade 80 House, Tucson, Arizona

The operational and thermal performance of the Decade 80 solar energy system is described. The system was designed by Cooper Development Association, Inc. with space heating and space cooling to a one-story, single family residence located in Tucson, Arizona. The Decade 80 House was designed and built in the mid-70's to be a showplace/workshop for solar energy utilization. Superior construction techniques, the use of quality materials and a full time maintenance staff have served to make the entire system an outstanding example of the application of solar energy for residential purposes. The luxury of a full time, on-site maintenance person is perhaps the single most important aspect of this program. While most installations cannot support this level of maintenance, it was very useful in keeping all subsystems operating in top form and allowing for a full season data collection to be obtained. Several conclusions were drawn from the long term monitoring effort, among which are: (1) flat plate collectors will support cooling; (2) definite energy savings can be realized; and (3) more frequent periodic maintenance may be required on solar energy systems that are not custom built.

Source record↗

Solar energy system performance evaluaton: Seasonal report for Solaron-Akron, Akron, Ohio

The operational and thermal performance of the solar energy system by Solaron Corporation is described. The system was designed to provide an 1940 square foot floor area with space heating and domestic hot water for a dual-level single family residence in Akron, Ohio. The solar energy system uses air as the heat transport medium, has a 546 square foot flat plate collector array subsystem, a 270 cubic foot rock thermal storage bin subsystem, a domestic hot water preheat tank, pumps, controls and transport lines. In general, the performance of the Solaron Akron solar energy system was somewhat difficult to assess for the November 1978 through October 1979 time period. The problems relating to the control systems, various solar energy leakages, air flow correction factors and instrumentation cause a significant amount of subjectivity to be involved in the performance assessment for this solar energy system. Had these problems not been present, it is felt that this system would have exhibited a resonably high level of measured performance.

Source record↗