Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Lightning to the ionosphere

It is pointed out that most lightning discharges take place within clouds or between clouds and the ground. There are a few reports, however, of a much rarer form of lightning that has been observed to come out of the top of the thunderstorm cloud and extend vertically for some distance into the clear air above it. A description is presented of the observations of such an incident made by a NASA pilot. The incident occurred when the pilot was flying a T-38 jet aircraft at an altitude of about 40,000 feet over Amarillo in Texas. The pilot found himself behind an extremely fast-moving very large cold front. A large number of lightning flashes could be seen. While most of the lightning flashes were typical, approximately every 50th or 100th discharge would go from the top of a cloud vertically upwards through the clear air towards the ionosphere. Explanations for these observations are discussed.

Vaughan, O. H., Jr.↗

Data management of Shuttle radiofrequency navigation aids

It is noted that the Shuttle navigation system employs redundant tactical air navigation (tacan) and microwave scanning beam landing system (MSBLS) equipment for use in navigation during descent from altitudes of about 150,000 feet through rollout. Attention is given here to the multiple tacan and MSBLS units (three each) that were placed onboard to provide the necessary protection in the event of possible failures. The goals, features, approach, and performance of onboard software required to manage multiple tacan MSBLS units and to provide the corresponding data for navigation processing are described.

Stokes, R. E.↗

Hindlimb immobilization - Length-tension and contractile properties of skeletal muscle

Casts were placed around rat feet in plantar flexion position to immobilize the soleus muscle in a shortened position, while the other foot was fixed in dorsal flexion to set the extensor digitorum longus in a shortened position. The total muscular atrophy and contractile properties were measured at 1, 2, 4, 7, 14, 21, 28, 35, and 42 days after immobilization, with casts being replaced every two weeks. The slow twitch soleus and the fast-twitch vastus lateralis and longus muscles were excised after termination of the experiment. The muscles were then stretched and subjected to electric shock to elicit peak tetanic tension and peak tetanic tension development. Force velocity features of the three muscles were assayed in a series of afterloaded contractions and fiber lengths were measured from subsequently macerated muscle. All muscles atrophied during immobilization, reaching a new steady state by day 21. Decreases in fiber and sarcomere lengths were also observed.

Witzmann, F. A.↗

Shuttle entry GN&C performance during STS-1 and STS-2

Data obtained during the entry segment of the descent phase of the flights are analyzed. The nominal entry profile is defined and a description is given of the guidance, navigation, and control subsystem. Emphasis is placed on the stability and control problems encountered during STS-1 and to the changes made in response to these anomalies. These are: (1) the first roll maneuver was done manually at a reduced roll rate; (2) the nominal elevator position was changed from one degree up to one degree down for Mach numbers greater than 12 to reduce the heat load on the body flap; (3) the pilot was directed to execute small roll maneuvers at dynamic pressures of 4, 8, and 18 psf to help determine the roll moment from the aft yaw jets; (4) the planned test inputs in the transonic region were reduced in magnitude; and (5) the targeted touchdown point was moved 500 feet closer to the runway threshold.

Mcwhorter, L. B.↗

Radar imagery for forest cover mapping

Dual-polarized, X-band Synthetic Aperture Radar (SAR) imagery was obtained from an altitude of 60,000 feet over a test area near Camden, SC on June 30, 1980. The objective of this study was to determine, qualitatively, the value of the SAR imagery for identifying various forest cover types. In analyzing the HH and HV polarization images, particular attention was given to the tonal and textural characteristics of the cover types involved. The analysis of the dual-polarized SAR imagery has shown that certain forest cover features are more easily identified in one polarization than the other, while some features look very similar in both polarizations. In general, the results for this data set have shown that the overall tonal contrast between features was greater on the HH image. Neither polarization was consistently better for identifying the various forest cover types examined. These results suggest the usefulness of a dual-polarized SAR system for mapping forest cover.

Knowlton, D. J.↗

Unmanned Instrument Platform for Undersea Exploration

Instruments accommodated on moving underwater platform. Towable underwater platform 3.2 meters long, 1.2 meters wide, 1.4 meters high and has mass of about 1,250 kilogram. Platform remotely operated and unmanned. Serves as test bed for development of ocean-measuring instruments and sonars at depths to 20,000 feet.

Paine, G.↗

Laboratory modeling and analysis of aircraft-lightning interactions

Modeling studies of the interaction of a delta wing aircraft with direct lightning strikes were carried out using an approximate scale model of an F-106B. The model, which is three feet in length, is subjected to direct injection of fast current pulses supplied by wires, which simulate the lightning channel and are attached at various locations on the model. Measurements are made of the resulting transient electromagnetic fields using time derivative sensors. The sensor outputs are sampled and digitized by computer. The noise level is reduced by averaging the sensor output from ten input pulses at each sample time. Computer analysis of the measured fields includes Fourier transformation and the computation of transfer functions for the model. Prony analysis is also used to determine the natural frequencies of the model. Comparisons of model natural frequencies extracted by Prony analysis with those for in flight direct strike data usually show lower damping in the in flight case. This is indicative of either a lightning channel with a higher impedance than the wires on the model, only one attachment point, or short streamers instead of a long channel.

Turner, C. D.↗

Improved SCR ac Motor Controller for Battery Powered Urban Electric Vehicles

An improved ac motor controller, which when coupled to a standard ac induction motor and a dc propulsion battery would provide a complete electric vehicle power train with the exception of the mechanical transmission and drive wheels was designed. In such a system, the motor controller converts the dc electrical power available at the battery terminals to ac electrical power for the induction motor in response to the drivers commands. The performance requirements of a hypothetical electric vehicle with an upper weight bound of 1590 kg (3500 lb) were used to determine the power rating of the controller. Vehicle acceleration capability, top speed, and gradeability requisites were contained in the Society of Automotive Engineers (SAE) Schedule 227a(d) driving cycle. The important capabilities contained in this driving cycle are a vehicle acceleration requirement of 0 to 72.4 kmph (0 to 45 mph) in 28 seconds a top speed of 88.5 kmph (55 mph), and the ability to negotiate a 10% grade at 48 kmph (30 mph). A 10% grade is defined as one foot of vertical rise per 10 feet of horizontal distance.

Latos, T. S.↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

THERMTRAJ: A FORTRAN program to compute the trajectory and gas film temperatures of zero pressure balloons

A FORTRAN computer program called THERMTRAJ is presented which can be used to compute the trajectory of high altitude scientific zero pressure balloons from launch through all subsequent phases of the balloon flight. In addition, balloon gas and film temperatures can be computed at every point of the flight. The program has the ability to account for ballasting, changes in cloud cover, variable atmospheric temperature profiles, and both unconditional valving and scheduled valving of the balloon gas. The program was verified for an extensive range of balloon sizes (from 0.5 to 41.47 million cubic feet). Instructions on program usage, listing of the program source deck, input data and printed and plotted output for a verification case are included.

Horn, W. J.↗

Flight summaries and temperature climatology at airliner cruise altitudes from GASP (Global Atmospheric Sampling Program) data

Temperature data obtained by the Global Atmospheric Sampling Program (GASP) during the period March 1975 to July 1979 are compiled to form flight summaries of static air temperature and a geographic temperature climatology. The flight summaries include the height and location of the coldest observed temperature and the mean flight level, temperature and the standard deviation of temperature for each flight as well as for flight segments. These summaries are ordered by route and month. The temperature climatology was computed for all statistically independent temperture data for each flight. The grid used consists of 5 deg latitude, 30 deg longitude and 2000 feet vertical resolution from FL270 to FL430 for each month of the year. The number of statistically independent observations, their mean, standard deviation and the empirical 98, 50, 16, 2 and .3 probability percentiles are presented.

Nastrom, G. D.↗

Large diameter astromast development, phase 1

Coilable-longeron lattice columns called Astromasts (trademark) were manufactured for a variety of spacecraft missions. These flight structures varied in diameter from 0.2 to 0.5 meter (9 to 19 in.), and the longest Astromast of this type deploys to a length of 30 meters (100 feet). A double-laced diagonal Astromast design referred to as the Supermast (trademark) which, because it has shorter baylengths than an Astromast, is approximately four times as strong. The longeron cross section and composite material selection for these structures are limited by the maximum strain associated with stowage and deployment. As a result, future requirements for deployable columns with high stiffness and strength require the development of both structures in larger diameters. The design, development, and manufacture of a 6.1-m-long (20-ft), 0.75-m-diameter (30-in.), double-laced diagonal version of the Astromast is described.

Preiswerk, P. R.↗

Preliminary engineering study: Quick opening valve MSFC high Reynolds number wind tunnel

FluiDyne Engineering Corporation has conducted a preliminary engineering study of a quick-opening valve for the MSFC High Reynolds Number Wind Tunnel under NASA Contract NAS8-35056. The subject valve is intended to replace the Mylar diaphragm system as the flow initiation device for the tunnel. Only valves capable of opening within 0.05 sec. and providing a minimum of 11.4 square feet of flow area were considered. Also, the study focused on valves which combined the quick-opening and tight shutoff features in a single unit. A ring sleeve valve concept was chosen for refinement and pricing. Sealing for tight shutoff, ring sleeve closure release and sleeve actuation were considered. The resulting cost estimate includes the valve and requisite modifications to the facility to accommodate the valve as well as the associated design and development work.

Source record↗

Current status of visibility sensors for aviation

The development of a new increased range higher visibility was investigated. The visibility sensor that is currently is the Transmissometer. Current transmissometer technology provides only a factor of 10 dynamic range with a single base line. The FAA is preparing to install automated weather observing systems (AWOS) at many locations. These systems require visibilities up to approximately 5 miles. To use a transmissometer for this type of measurement, the base line must be about 1,000 feet; where alignment becomes very difficult to maintain. New technologies were developd for measuring visibility. Improved transmissometers, forward-scatter meters and back-scatter meters have become available. A current practical issue for visibility sensors is how to specify one that is good enough to meet the needs of aviation. The first question is what performance is required; how accurately must the sensor measure? Visibility sensors do not actually measure the visibility directly. The purpose of measuring the visibility is to predict what the pilot will see a considerable distance away from the sensor location. The atmosphere introduces considerable variation in the measurement and the basic sensor accuracy needed is difficult to define. The second question for high visibilities is what to use as the standard reference sensor. The third question pertains to the competitive procurement of visibility sensors, which is mandated at present. Two acceptance test procedures to be used to insure satisfactory sensor performance is examined.

David C. Burnham↗

Marked surface inversions and wind shear: A safety risk for departing aircraft

Marked surface inversions occur most frequently in dry continental climates, where low atmospheric humidity allows heat transfer by long wave thermal radiation. In the northern latitudes, surface inversions reach their maximum intensity during the winter, when the incoming Sun's radiation is negligible and radiative cooling is dominant during the long nights. During winter, air mass boundaries are sharp, which causes formation of marked surface inversions. The existence of these inversions and sharp boundaries increase the risk of wind shear. The information should refer to marked inversions exceeding a temperature difference of 10 deg C up to 1000 feet. The need to determine the temperature range over which he information is operationally needed and the magnitude of the inversion required before a notification to pilots prior to departure is warranted are outlined.

Ossi Korhonen↗

Lightning strike experience in the NASA F-106B storm hazards program

A heavily instrumented F-106B aircraft was flown in thunderstorms to gather data for characterizing lightning at aircraft operating altitudes. Conventional weather finding techniques are supplemented with UHF lightning mapping radar to select the most active storm cells and the most likely altitude for obtaining direct lightning strikes to the airplane. One hundred seventy-six strikes were obtained in a 3 year period, mostly at an altitude of above 25,000 feet.

Norman L Crabill↗

Chromospheric evaporation in a well-observed compact flare

Hudson and Ohki (1972) pointed out that the increase of the soft X-ray emission measure during flares might be accounted for in two different ways, either by 'coronal condensation', or by what they termed 'chromospheric rarefaction', now more commonly called 'chromospheric evaporation'. They ruled out coronal condensation on the basis of cornal mass content arguments. Moore et al. (1980) found it highly probable that the bulk of the mass of the soft X-ray emitting plasma is supplied during the rise phase by chromospheric evaporation from the feet of the soft X-ray loops. On the other hand, Cheng et al. (1981) argued that chromospheric evaporation is not important as a source of soft X-ray plasma. The present investigation is concerned with an event in which direct chromospheric observations contradict the conclusions reached by Cheng et al. Up to now chromospheric evaporation has always been an inference, without compelling positive evidence. In the current investigation, observations are considered which constitute such evidence.

Acton, L. W.↗

Flight testing of the Space Shuttle

An account is given of the flight testing development phase of the Space Shuttle Orbiter. Because of its low lift-to-drag ratio, the Orbiter must make its 280-kt landing approach in the lower atmosphere with a steep descent angle of 19 deg, pulling up at 1800 feet altitude to a 1-1.5 deg descent angle, and finally gliding to a landing at 195 kt. The Orbiter has almost neutral aerodynamic static stability in pitch and yaw, requiring the use of electronic stabilization to augment the vehicle's natural stability. Attention is given to the flight test program, which comprised the first four flights of the Space Shuttle, and which substantially relied on preflight analysis to establish confidence in Shuttle flight performance. Also discussed are the solar radiation absorption and aerodynamic heating characteristics

Brand, V. D.↗