Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Development of Wien filter for small ion gun of surface analysis

The gas cluster ion beam (GCIB) and liquid metal ion beam have been studied in the context of ion beam usage for analytical equipment in applications such as X-ray photoelectron spectroscopy and secondary ion mass spectroscopy (SIMS). In particular, small ion sources are used for the secondary ion generation and ion etching. To set the context to this study, the SIMS project has been launched to develop ion-gun based analytical equipment for the Korea Basic Science Institute. The objective of the first stage of the project is the generation of argon beams with a GCIB system [A. Kirkpatrick, Nucl. Instrum. Methods Phys. Res., Sect. B 206, 830–837 (2003)] that consists of a nozzle, skimmer, ionizer, acceleration tube, separation system, transport system, and target. The Wien filter directs the selected cluster beam to the target system by exploiting the velocity difference of the generated particles from GCIB. In this paper, we present the theoretical modeling and three-dimensional electromagnetic analysis of the Wien filter, which can separate Ar{sup +}{sub 2500} clusters from Ar{sup +}{sub 2400} to Ar{sup +}{sub 2600} clusters with a 1-mm collimator.

43 PARTICLE ACCELERATORS↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Gain media edge treatment to suppress amplified spontaneous emission in a high power laser

A novel method and apparatus for suppressing ASE and/or parasitic oscillation modes in a laser is introduced. By roughening one or more peripheral edges of a solid-state crystal or ceramic laser gain media and by bonding such edges to a predetermined electromagnetic absorbing material arranged adjacent to the entire outer surface of the peripheral edges of the roughened laser gain media, ASE, parasitic oscillation modes and/or residual pump energy can be effectively suppressed.

47 OTHER INSTRUMENTATION↗

Detection of a concealed object

Disclosed are systems, methods, devices, and apparatus to determine if a clothed individual is carrying a suspicious, concealed object. This determination includes establishing data corresponding to an image of the individual through interrogation with electromagnetic radiation in the 200 MHz to 1 THz range. In one form, image data corresponding to intensity of reflected radiation and differential depth of the reflecting surface is received and processed to detect the suspicious, concealed object.

47 OTHER INSTRUMENTATION↗

Hadron Physics with CLAS12

Hadron spectroscopy has been an essential part of the physics program with the CLAS detector in experimental Hall B at Jefferson Lab. Production of baryon and meson resonances with high energy (polarized) electron and photon beams was studied on a veriety of targets, ranging from hydrogen to lead. Physics topics of interest include: investigation of the spectrum of baryon and meson resonances, transition form-factors, meson-nucleon couplings (mesons in nuclei), and search for exotic and missing states. With the 12 GeV upgrade of the CEBAF machine, hadron spectroscopy in Hall B will be extended to a new domain of higher mass resonances and the range of higher transferred momentum using up to 11 GeV electron beams and the upgraded CLAS12 detector. In this paper a brief description of the CLAS12 detector and the physics program adopted for 12 GeV with emphasis to baryon and meson spectroscopy is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Work Towards Experimental Evidence Of Hard X-Ray Photoionization In Highly Charged Krypton

Ions of almost any charge state can be produced through electron-impact ionization. Here we describe our first experiments designed to photoionize these highly charged ions with hard x-rays by pairing an electron and photon beam. A spectral line at 12.7(1) keV with an intensity corroborated by theory may be the first evidence of hard x-ray photoionization of a highly charged ion.

74 ATOMIC AND MOLECULAR PHYSICS↗

Anomalous hyperfine structure of NSF{sub 3} in the degenerate vibrational state v{sub 5}=1: Lifting of the parity degeneracy by the fluorine spin-rotation interaction

For the principal isotopologue {sup 14}N{sup 32}S{sup 19}F{sub 3} of thiazyl trifluoride in the degenerate fundamental state (v{sub 5}=1), the hyperfine structure has been investigated in the Q-branch spectrum between 8 and 26.5 GHz using microwave Fourier transform waveguide spectrometers with a resolution limit of {approx_equal}30 kHz. In addition to l-type doubling spectra and l-type resonance transitions with ({Delta}k={Delta}l={+-}2), perturbation-allowed spectra were measured with {Delta}(k-l)={+-}3,{+-}6. The range in J was from 13 to 61; for the lower states, kl=-3,-2,-1,0,+1. For all the transitions, the hyperfine patterns observed are predicted to be doublets when only the nitrogen quadrupole Hamiltonian H{sub Q}{sup N} is taken into account. Doublets were indeed measured for transitions with {Gamma}{sub RV}=A{sub 1{r_reversible}}A{sub 2}, where {Gamma}{sub RV} is the rovibrational symmetry. However, when {Gamma}{sub RV}=E{r_reversible}E, triplets and quartets were observed in addition to doublets. These anomalous hyperfine patterns are shown to be due to the ({Delta}k={+-}1) and ({Delta}k={+-}2) matrix elements of the fluorine spin-rotation Hamiltonian H{sub SR}{sup F} characterized by the fluorine spin-rotation constants c(1)=(1/2)(c{sub xz}+c{sub zx}{sup *}) and c(2)=(1/2)(c{sub xx}-c{sub yy}), respectively. These terms in H{sub SR}{sup F} lift the parity degeneracy for {Gamma}{sub RV}=E. The rovibrational Hamiltonian H{sub RV} was adopted from an earlier partner study [S. Macholl et al., J. Phys. Chem. A 113, 668 (2009)]. A good fit to the hyperfine data was obtained with a standard deviation of 3.1 kHz. In the fitting process, 12 rovibrational parameters were varied, while the remaining constants in H{sub RV} were left at the values of Macholl et al. In addition, six hyperfine parameters were determined: four in H{sub Q}{sup N}, and two in H{sub SR}{sup F}. It was found that |c(1)|=7.48(24) kHz and |c(2)|=2.423(22) kHz. This determination of c(1) is the first to be reported based on frequency measurements. In all the previous detections of parity doubling where the splittings were accounted for quantitatively, the levels involved had K=|k|=1 in studies of the ground vibrational state or G{identical_to}|k-l|=1 in investigations of degenerate vibrational states. In the current work, several different values of G were involved, thus demonstrating experimentally for the first time that this splitting process is a general phenomenon. The key to the observation of the parity doubling lies in the regional resonances discovered by Macholl et al. The clustering of rovibrational levels at low K leads to severe mixing. For each eigenstate involved in a regional resonance, the eigenstate consists of a linear superposition of basis vectors with several different values of kl having sizable expansion coefficients. As a result, the ({Delta}k={+-}1,{+-}2) matrix elements of H{sub SR}{sup F} that typically connect levels widely separated in energy occur here effectively on the diagonal, thereby greatly enhancing the effects of c(1) and c(2). These spin-rotation matrix elements are derived here for {Gamma}{sub RV}=E in the low-field representation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Neutron physics of the Re/Os clock. I. Measurement of the (n,gamma) cross sections of {sup 186,187,188}Os at the CERN n{sub T}OF facility

The precise determination of the neutron capture cross sections of {sup 186}Os and {sup 187}Os is important to define the s-process abundance of {sup 187}Os at the formation of the solar system. This quantity can be used to evaluate the radiogenic component of the abundance of {sup 187}Os due to the decay of the unstable {sup 187}Re (t{sub 1/2}=41.2 Gyr) and from this to infer the time duration of the nucleosynthesis in our galaxy (Re/Os cosmochronometer). The neutron capture cross sections of {sup 186}Os, {sup 187}Os, and {sup 188}Os have been measured at the CERN n{sub T}OF facility from 1 eV to 1 MeV, covering the entire energy range of astrophysical interest. The measurement has been performed by time-of-flight technique using isotopically enriched samples and two C{sub 6}D{sub 6} scintillation detectors for recording the prompt gamma rays emitted in the capture events. Maxwellian averaged capture cross sections have been determined for thermal energies between kT=5 and 100 keV corresponding to all possible s-process scenarios. The estimated uncertainties for the values at 30 keV are 4.1, 3.3, and 4.7% for {sup 186}Os, {sup 187}Os, and {sup 188}Os, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the mechanism of formation of excited states of the {sup 8}Be nucleus in the reaction {sup 12}C({gamma}, 3{alpha})

The reaction {sup 12}C({gamma}, 3{alpha}) was studied with the aid of a diffusion chamber placed in a magnetic field, filled with a methane-helium mixture, and irradiated with bremsstrahlung photons of endpoint energy 150 MeV. The total reaction cross section was measured in the energy range E{sub {gamma} }< 40 MeV. The ground state; the first, second, and unseparated third and fourth excited states; and highly excited states (in the range 19.9 < E{sub x} < 25.2 MeV) of the {sup 8}Be nucleus manifested themselves in the distribution of events with respect to the energy of the relative motion of two alpha particles. A resonance that is characterized by the energy of E{sub 0} = 0.72 MeV and the width of {Gamma} = 0.80 MeV and which was identified as a ghost anomaly was found between the ground state and the first excited state. Partial cross sections were measured for various channels. Excited states are formed in narrow photon-energy intervals, and their partial cross sections are of a resonance shape. It is found that the energy corresponding to the maximum of the partial cross section for the ith level, E{sub m}{sup i}, and the excitation energy of the next level, E{sub 0}{sup i+1}, are correlated: E{sub m}{sup i} = E{sub 0}{sup i+1} + {epsilon}, where {epsilon} is the reaction threshold. The results are qualitatively explained on the basis of a model that assumes photon absorption by an alpha-particle pair.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

An all-dielectric metasurface as a broadband optical frequency mixer

A frequency mixer is a nonlinear device that combines electromagnetic waves to create waves at new frequencies. Mixers are ubiquitous components in modern radio-frequency technology and microwave signal processing. The development of versatile frequency mixers for optical frequencies remains challenging: such devices generally rely on weak nonlinear optical processes and, thus, must satisfy phase-matching conditions. Here we utilize a GaAs-based dielectric metasurface to demonstrate an optical frequency mixer that concurrently generates eleven new frequencies spanning the ultraviolet to near-infrared. The even and odd order nonlinearities of GaAs enable our observation of second-harmonic, third-harmonic, and fourth-harmonic generation, sum-frequency generation, two-photon absorption-induced photoluminescence, four-wave mixing and six-wave mixing. The simultaneous occurrence of these seven nonlinear processes is assisted by the combined effects of strong intrinsic material nonlinearities, enhanced electromagnetic fields, and relaxed phase-matching requirements. In conclusion, such ultracompact optical mixers may enable a plethora of applications in biology, chemistry, sensing, communications, and quantum optics.

47 OTHER INSTRUMENTATION↗

Note: On-chip multifunctional fluorescent-magnetic Janus helical microswimmers

Microswimmers integrated into microfluidic devices that are capable of self-illumination through fluorescence could revolutionize many aspects of technology, especially for biological applications. Few illumination and propulsion techniques of helical microswimmers inside microfluidic channels have been demonstrated. This paper presents the fabrication, detachment, and magnetic propulsions of multifunctional fluorescent-magnetic helical microswimmers integrated inside microfluidics. The fabrication process is based on two-photon laser lithography to pattern 3-D nanostructures from fluorescent photoresist coupled with conventional microfabrication techniques for magnetic thin film deposition by shadowing. After direct integration inside a microfluidic device, injected gas bubble allows gentle detachment of the integrated helical microswimmers whose magnetic propulsion can then be directly applied inside the microfluidic channel using external electromagnetic coil setup. With their small scale, fluorescence, excellent resistance to liquid/gas surface tension, and robust propulsion capability inside the microfluidic channel, the microswimmers can be used as high-resolution and large-range mobile micromanipulators inside microfluidic channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fast simulation of the CMS detector at LHC

The CMS collaboration has developed a fast Monte Carlo simulation of the CMS detector with event production rates ~100 times faster than the GEANT4-based simulation, with nonetheless comparable accuracy for most of the physics objects typically considered in the analyses. We discuss basic technical principles of the CMS Fast Simulation and their implementation in the different components of the detector: the silicon tracker, the electromagnetic calorimeter, the hadronic calorimeter, the muon system, the Level 1 and the High Level Trigger. A few comparisons of the Fast Simulation results both with the GEANT4-based Full Simulation and with the LHC data are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical and Experimental Beam Plasma Physics (TEBPP)

The theoretical and experimental beam plasma physics (TEBPP) consists of a package of five instruments to measure electric and magnetic fields, plasma density and temperature, neutral density, photometric emissions, and energetic particle spectra during firings of the particle injector (SEPAC) electron beam. The package is developed on a maneuverable boom (or RMS) and is used to measure beam characteristics and induced perturbations field ( 10 m) and mid field ( 10 m to 100 m) along the electron beam. The TEBPP package will be designed to investigate induced oscillations and induced electromagnetic mode waves, neutral and ion density and temperature effects, and beam characteristics as a function of axial distance.

Roberts, B.↗

Langley proposed advanced hypervelocity aerophysics facility - A status report

A ground-based facility capable of performing flight tests on relatively large highly instrumented models and scaled vehicle components at velocities and densities representative of a hypervelocity flight in earth and planetary atmospheres is reviewed. This facility proposed by the Langley Research Center is based on a launcher, a test chamber, and a model impact/deceleration chamber. It would initially utilize existing light-gas gun launcher technology scaled to 4 times present launcher size. It is planned to enhance its velocity and model size capability either by an electromagnetic launcher or a ram accelerator.

Witcofski, Robert D.↗

Differential cross sections and spin density matrix elements for {gamma}p {yields} {phi}p from CLAS

Preliminary differential cross-sections and the {rho}{sub MM'}{sup 0} spin density matrix elements (SDME) for the reaction {gamma}{rho} {yields} {phi}p for both charged-({phi} {yields} K{sup +}K-) and neutral-mode ({phi} {yields} K{sub L}{sup 0}K{sub S}{sup 0}) topologies obtained from CLAS are presented. Our kinematic coverage is from near production threshold ({radical}(s){approx}1.97 GeV) to ({radical}(s) 2.84 GeV), with a wide coverage in the production angle. As seen in previous LEPS results, the differential cross-sections show a localized 'bump' between ({radical}(s){approx}2 and 2.2 GeV that is not expected from a simple Pomeron exchange picture. Comparisons between the charged- and neutral-mode results and possible effects from the K{sup +}{Lambda}(1520) channel are discussed. Our SDME results confirm the well-known deviations from t-channel helicity conservation (TCHC) for Pomeron exchange, but s-channel helicity conservation (SCHC) is also seen to be broken.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗