Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Patient Dose During Carotid Artery Stenting With Embolic-Protection Devices: Evaluation With Radiochromic Films and Related Diagnostic Reference Levels According to Factors Influencing the Procedure

To measure the maximum entrance skin dose (MESD) on patients undergoing carotid artery stenting (CAS) using embolic-protection devices, to analyze the dependence of dose and exposure parameters on anatomical, clinical, and technical factors affecting the procedure complexity, to obtain some local diagnostic reference levels (DRLs), and to evaluate whether overcoming DRLs is related to procedure complexity. MESD were evaluated with radiochromic films in 31 patients (mean age 72 {+-} 7 years). Five of 33 (15 %) procedures used proximal EPD, and 28 of 33 (85 %) procedures used distal EPD. Local DRLs were derived from the recorded exposure parameters in 93 patients (65 men and 28 women, mean age 73 {+-} 9 years) undergoing 96 CAS with proximal (33 %) or distal (67 %) EPD. Four bilateral lesions were included. MESD values (mean 0.96 {+-} 0.42 Gy) were <2 Gy without relevant dependence on procedure complexity. Local DRL values for kerma area product (KAP), fluoroscopy time (FT), and number of frames (N{sub FR}) were 269 Gy cm{sup 2}, 28 minutes, and 251, respectively. Only simultaneous bilateral treatment was associated with KAP (odds ratio [OR] 10.14, 95 % confidence interval [CI] 1-102.7, p < 0.05) and N{sub FR} overexposures (OR 10.8, 95 % CI 1.1-109.5, p < 0.05). Type I aortic arch decreased the risk of FT overexposure (OR 0.4, 95 % CI 0.1-0.9, p = 0.042), and stenosis {>=} 90 % increased the risk of N{sub FR} overexposure (OR 2.8, 95 % CI 1.1-7.4, p = 0.040). At multivariable analysis, stenosis {>=} 90 % (OR 2.8, 95 % CI 1.1-7.4, p = 0.040) and bilateral treatment (OR 10.8, 95 % CI 1.1-109.5, p = 0.027) were associated with overexposure for two or more parameters. Skin doses are not problematic in CAS with EPD because these procedures rarely lead to doses >2 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization and Diagnostics Code for Technological Processes: Radiochemical Production Simulator

A software-hardware complex with the possibility of simulating the functioning of technological processes with APCS in real and accelerated time is being developed as part of Project Breakthrough in order to determine the optimal operating regimes of the technological processes of the units in a closed nuclear fuel cycle. It makes possible monitoring and control functions and the visualization and archiving of the results of simulation, which makes it possible at the development stages of technologies to evaluate the degree of adherence to the requirements of the technological equipment, regulating organs and final-control mechanisms, measurement apparatus, and monitoring channels, to analyze the control and diagnostics algorithms, blocking and protection, and to make when necessary changes in the design being developed. The developed software-hardware complex is a stimulator that will make it possible not only to investigate process schemes with their corresponding algorithms but also to develop training complexes for the training and certification of service personnel.

42 ENGINEERING↗

Ensuring Safety of Hydraulic Equipment at the Votkinsk Hydroelectric Power Plant with an Automated Diagnostic Monitoring System

Experience with the use of an automated diagnostic monitoring system for the technical condition and safety of concrete structures at the Votkinsk HPP is discussed. The automated system for monitoring the state of the hydraulic engineering systems has been developed to increase the accuracy, reliability, and efficiency of the data from instrumental observations during operation of the plant.

42 ENGINEERING↗

Simulation, Design, Construction of Duoplasmatron and Diagnostic Neutral Beam System for Alborz Tokamak

Diagnostic Neutral Beam (DNB) has been used for measuring plasma parameters of tokamaks such as ion and electron temperature, safety factor, impurity concentration and etc. Ion source and electrical power supply specification are the main part of DNB. Arc discharge current value is affected by filament current and anode voltage. Beam current changes with arc current signal in our experiment that agree with theoretical relations. Sixty milli-ampere (60 mA) pulse beam current is because of arc current of about 40 A and extraction voltage of about 20 kV. The increase of beam current with arc current has been reported experimentally and effect of arc current on beam current has been investigated for several high extraction voltages. Optimum condition, which means having a telescopic beam (minimum divergence) for specific parameters of duoplasmatron, has been simulated and verified with experimental test. The best extraction voltage for these parameters has been found to be about 16-kV. The ratio of the perpendicular velocity to parallel velocity has been calculated to be about 0.012. It has been shown experimentally with optical emission spectroscopy that increase in arc current and magnetic current increase proton content of beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physical Reasoning to Synchronize Electrical Signals and Related Diagnostics in Plasma Focus Devices

Plasma Focus (PF) devices as well as other similar pulsed discharge devices requires a variety of diagnostics for their proper control and optimization, including the voltage between electrodes, the time derivative of the discharge current, detection of X-rays and neutron emissions, and pulsed laser images (Shadow, Schlieren, interferograms). This article discusses the problem of the time reference of all these outputs and proposes specific techniques for synchronizing them based on sound physical grounds. The foundations of synchronization criterion are verified in several experiments on PF devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave Diagnostics and Forcing

Physical possibilities of remote diagnostics and manipulation with the state of the propagation medium by the methods of wave tomosynthesis are considered. This refers to the electromagnetic and acoustic waves as well as waves of other nature. Important are multi-position measurements with retention of phase information at each point of the medium that allows the technology of synthesizing a wide aperture with focusing to be implemented. Processing of wave projections of hidden objects makes it possible to restore their three-dimensional images. In this way, the effect of multiple wave re-reflections is reduced. In addition, the tomographic approach allows one to manipulate with the properties of the media being sounded. Thus, an increase in the radiation power at a chosen focusing point causes hyperthermia that can be used, for example, to treat oncological diseases. And creation of a minimum field and a preset phase distribution in certain regions of the medium opens the possibility of control over the motion of microparticles being trapped. The last circumstance is important, for example, for targeted delivery of medical preparations in medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Copper fine-structure K-shell electron impact ionization cross sections for fast-electron diagnostic in laser-solid experiments

The K-shell electron impact ionization (EII) cross section, along with the K-shell fluorescence yield, is one of the key atomic parameters for fast-electron diagnostic in laser-solid experiments through the K-shell emission cross section. In addition, copper is a material that has been often used in those experiments because it has a maximum total K-shell emission yield. Furthermore, in a campaign dedicated to the modeling of the K lines of astrophysical interest (Palmeri et al., 2012), the K-shell fluorescence yields for the K-vacancy fine-structure atomic levels of all the copper isonuclear ions have been calculated. In this study, the K-shell EII cross sections connecting the ground and the metastable levels of the parent copper ions to the daughter ions K-vacancy levels considered in Palmeri et al. (2012) have been determined. The relativistic distorted-wave (DW) approximation implemented in the FAC atomic code has been used for the incident electron kinetic energies up to 10 times the K-shell threshold energies. Moreover, the resulting DW cross sections have been extrapolated at higher energies using the asymptotic form proposed by Davies et al. (2013)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Vanadium fine-structure K-shell electron impact ionization cross sections for fast-electron diagnostic in laser–solid experiments

The K-shell electron impact ionization (EII) cross section, along with the K-shell fluorescence yield, is one of the key atomic parameters for fast-electron diagnostic in laser–solid experiments through the K-shell emission cross section. In addition, in a campaign dedicated to the modeling of the K lines of astrophysical interest (Palmeri et al. (2012)), the K-shell fluorescence yields for the K-vacancy fine-structure atomic levels of all the vanadium isonuclear ions have been calculated. In this study, the K-shell EII cross sections connecting the ground and the metastable levels of the parent vanadium ions to the daughter ions K-vacancy levels considered in Palmeri et al. (2012) have been determined. The relativistic distorted-wave (DW) approximation implemented in the FAC atomic code has been used for the incident electron kinetic energies up to 20 times the K-shell threshold energies. Moreover, the resulting DW cross sections have been extrapolated at higher energies using the asymptotic behavior of the modified relativistic binary encounter Bethe model (MRBEB) of Guerra et al. (2012) with the density-effect correction proposed by Davies et al. (2013)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of a quantitative diagnostic method of estrogen receptor expression levels by immunohistochemistry using organic fluorescent material-assembled nanoparticles

Highlights: Black-Right-Pointing-Pointer Organic fluorescent material-assembled nanoparticles for IHC were prepared. Black-Right-Pointing-Pointer New nanoparticle fluorescent intensity was 10.2-fold greater than Qdot655. Black-Right-Pointing-Pointer Nanoparticle staining analyzed a wide range of ER expression levels in tissue. Black-Right-Pointing-Pointer Nanoparticle staining enhanced the quantitative sensitivity for ER diagnosis. -- Abstract: The detection of estrogen receptors (ERs) by immunohistochemistry (IHC) using 3,3 Prime -diaminobenzidine (DAB) is slightly weak as a prognostic marker, but it is essential to the application of endocrine therapy, such as antiestrogen tamoxifen-based therapy. IHC using DAB is a poor quantitative method because horseradish peroxidase (HRP) activity depends on reaction time, temperature and substrate concentration. However, IHC using fluorescent material provides an effective method to quantitatively use IHC because the signal intensity is proportional to the intensity of the photon excitation energy. However, the high level of autofluorescence has impeded the development of quantitative IHC using fluorescence. We developed organic fluorescent material (tetramethylrhodamine)-assembled nanoparticles for IHC. Tissue autofluorescence is comparable to the fluorescence intensity of quantum dots, which are the most representative fluorescent nanoparticles. The fluorescent intensity of our novel nanoparticles was 10.2-fold greater than quantum dots, and they did not bind non-specifically to breast cancer tissues due to the polyethylene glycol chain that coated their surfaces. Therefore, the fluorescent intensity of our nanoparticles significantly exceeded autofluorescence, which produced a significantly higher signal-to-noise ratio on IHC-imaged cancer tissues than previous methods. Moreover, immunostaining data from our nanoparticle fluorescent IHC and IHC with DAB were compared in the same region of adjacent tissues sections to quantitatively examine the two methods. The results demonstrated that our nanoparticle staining analyzed a wide range of ER expression levels with higher accuracy and quantitative sensitivity than DAB staining. This enhancement in the diagnostic accuracy and sensitivity for ERs using our immunostaining method will improve the prediction of responses to therapies that target ERs and progesterone receptors that are induced by a downstream ER signal.

60 APPLIED LIFE SCIENCES↗

NMR-based serum metabolomics study reveals a innovative diagnostic model for missed abortion

A missed abortion (MA) is an in-utero death of the embryo or fetus before the 20th week of gestation with retained products of conception. In order to discover novel biomarkers for MA, a {sup 1}H NMR spectroscopy-based metabolomics approach was applied to detect human MA serum metabolic profiles. Serum samples were obtained from patients with MA (n = 15) and healthy controls (n = 9) for study. The NOESYPR1D spectrum combined with multi-variate pattern recognition analysis was used to cluster the groups and establish a disease-specific metabolites phenotype. Principal component analysis (PCA) and orthogonal partial least-squares discriminant analysis (OPLS-DA) models were capable of distinguishing MA patients from healthy subjects. The results revealed that 24 metabolites altered in MA patients compared with the control population. Metabolomic pathway analysis demonstrated that alanine, aspartate and glutamate metabolism, citrate cycle (TCA cycle), taurine and hypotaurine metabolism were significantly altered in MA. The results indicated that serum NMR-based metabolomic profiling method is sensitive and specific enough to distinguish MA and from healthy controls, this method could be developed as a clinically useful diagnostic tool for MA. The finding from the MA serum metabolic profiling shed a new light on further understanding of MA disease mechanisms.

60 APPLIED LIFE SCIENCES↗

Straining and wrinkling processes during turbulence-premixed flame interaction measured using temporally-resolved diagnostics

The dynamical processes of flame surface straining and wrinkling that occur as turbulence interacts with a premixed flame were measured using cinema-stereoscopic PIV (CS-PIV) and orthogonal-plane cinema-stereoscopic PIV (OPCS-PIV). These diagnostics provided temporally resolved measurements of turbulence-flame interaction at frame rates of up to 3 kHz and spatial resolutions as small as 280{mu} m. Previous descriptions of flame straining and wrinkling have typically been derived based on a canonical interaction between a pair of counter-rotating vortices and a planar flame surface. However, it was found that this configuration did not properly represent real turbulence-flame interaction. Interactions resembling the canonical configuration were observed in less than 10% of the recorded frames. Instead, straining and wrinkling were generally caused more geometrically complex turbulence, consisting of large groups of structures that could be multiply curved and intertwined. The effect of the interaction was highly dependent on the interaction geometry. Furthermore, even when the turbulence did exist in the canonical geometry, the straining and wrinkling of the flame surface were not well characterized by the vortical structures. A new mechanistic description of the turbulence-flame interaction was therefore identified and confirmed by the measurements. In this description, flame surface straining is caused by coherent structures of fluid-dynamic strain-rate (strain-rate structures). The role of vortical structures is to curve existing flame surface, creating wrinkles. By simultaneously considering both forms of turbulent structure, turbulence-flame interactions in both the canonical configuration and more complex geometries could be understood. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A multi-chamber model of combustion instabilities and its assessment using kilohertz laser diagnostics in a gas turbine model combustor

A multi-chamber model for the combustion instabilities manifested in a gas turbine model combustor was developed. Here the proposed model was used to explain the dependencies of instability frequency on burner geometry and other flow parameters, some of which could not be reconciled with previous models. The new model was built upon the Helmholtz analysis of two connected resonators. The instability frequency as well as the complex pressure ratio between two chambers were predicted by solving ordinary differential equations. To assess the assumptions and predictions of the proposed model, the spectra and magnitude of the oscillations of pressure, heat release rate, and velocity were measured for four different operating conditions: rich (R1), lean (L1), stoichiometric (S1), and reduced flow rate (R2) with a kilohertz laser diagnostic system. These measurements reconfirmed that the instability is of Helmholtz type. A global equivalence ratio that is consistently greater than unity was identified to be an enabling factor for combustion instability. This is also in agreement with the predictions made by the proposed model. Furthermore, the model was shown to be able to predict the right trend of instability frequency when multiple parameters were changed. It is concluded that the current model is an improvement over previous models, because the acoustic coupling between different chambers of the burner was considered.

42 ENGINEERING↗

Integrating diagnostics and model-based optimization

Energy Management and Information Systems are a family of analytics technologies that include energy information systems, fault detection and diagnostics (FDD), and automated system optimization tools. Such systems have the potential to enable buildings to meet energy management goals of reducing total energy consumption and cost. Most current market offerings use data-driven and rule-based analytics. However, the use of physics-based models in the analytics offers potential improvements by providing an accurate estimation of outputs based on representation of the physical principles governing the building system behaviors. This also permits the use of design stage models to inform commissioning and operation. This paper describes the development and testing of a hybrid data-driven and physics model-based operational tool for energy efficiency in central cooling plants. The tool offers FDD functionality, setpoint optimization, and visualization of key performance parameters. It was demonstrated at a university campus in the mixed-humid ASHRAE Climate Zone 4A. Key performance metrics that were analyzed include plant electricity use reduction, plant model calibration, and system economics. Annual simulations indicate the tool can provide electricity savings of greater than 10% for approximately six months of the year, mainly during the winter season when wet bulb temperatures are low, though only 1.38% savings for the entire year. Additionally, over a 4-day period in April, recommended optimal setpoints were implemented, resulting in 17% savings versus metered baseline consumption. With respect to model calibration, the difference between model-predicted and measured parameters was less than 10% for 90% of data points acquired for three of six chillers, and for each ten cooling towers. Finally, the tool users reported that satisfaction with the capabilities was equal to or better than that with the preexisting BAS system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗