Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Determinants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Using cryoEM Reconstruction and Phase Extension to Determine Crystal Structure of Bacteriophage ${\Phi}$6 Major Capsid Protein

Bacteriophage ${\Phi}$6 is a double-stranded RNA virus that has been extensively studied as a model organism. In this paper we describe structure determination of ${\Phi}$6 major capsid protein P1. The protein crystallized in base centered orthorhombic space group C2221. Matthews’s coefficient indicated that the crystals contain from four to seven P1 subunits in the crystallographic asymmetric unit. The self-rotation function had shown presence of fivefold axes of non-crystallographic symmetry in the crystals. Thus, electron density map corresponding to a P1 pentamer was excised from a previously determined cryoEM reconstruction of the ${\Phi}$6 procapsid at 7 Å resolution and used as a model for molecular replacement. The phases for reflections at higher than 7 Å resolution were obtained by phase extension employing the fivefold non-crystallographic symmetry present in the crystal. Lastly, the averaged 3.6 Å-resolution electron density map was of sufficient quality to allow model building.

Cryo-electron microscopy↗

Determination of the Transition Temperature of a Weak Ferromagnetic Thin Film by Means of an Evolution of the Method Based on the Arrott Plots

The ferromagnetic transition temperature (T{sub c}) of a weak ferromagnetic thin film Cu{sub 0.38}Ni{sub 0.62} has been estimated by using an evolution of the Belov, Goriaga, and Arrott (BGA) model. In fact, the typically used measurements of the zero-field-cooled-field-cooled magnetic moment (m) as a function of temperature (T), the magnetic hysteresis loops (m(H)) as a function of field, and the temperature dependence of the remanent magnetic moment, performed on our sample, did not allow us to individuate precisely the value of T{sub c}, mainly due to the influence of thermal effects and noise on the weak ferromagnetic response of the sample, resulting in a large uncertainty in the estimation of T{sub c}. On the other hand, also the commonly used method of determining the T{sub c} by means of a linear extrapolation of the high-field region of m{sup 2} as a function of the normalized magnetic field (H/m) at different temperatures (Arrott curves), working though for our analyzed material, could not completely fulfill the basic assumptions of the BGA model in general. For these reasons, we have considered the analysis of the derivatives of the Arrott curves, starting from observing that the T{sub c} of the sample corresponds to the temperature where the curvature of the Arrott curves at low fields inverts. In this way, the sensitivity in the determination of the Curie point from the inductive measurements of the magnetic moment is improved while the correct assumptions of the Arrott model are also fully respected.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining HPGe Total Detection Efficiency Using γ–γ Coincidence

Abstract Both the peak and total detection efficiencies are generally needed in order to calculate sample activity from a gamma spectroscopic measurement, except in the case of isotope specific calibration. This is particularly true when the sample is in close proximity to the detector and corrections for cascade summing effects are required to avoid significant inaccuracy in the result. These corrections use the total detection efficiency to correct for summing-in and summing-out events, and the extent of the correction depends on both the geometry and the gamma cascade for the isotope in question. Experimentally determining the total efficiency is a labor intensive endeavor requiring multiple measurements with a set of single-gamma-emitting standards. Modeling the total efficiency vs. energy may be less time consuming, but is also likely to produce less confidence in the final result. Pacific Northwest National Laboratory's Radiation Detection and Nuclear Sciences group has constructed a low background 14-crystal HPGe array for sample measurement; in all measurements, samples will be in close proximity to the germanium crystals. This close geometry and the sheer number efficiency calibrations required for the system have led us to investigate methods to simplify the efficiency calibration procedure. One method we are developing uses the Y-Y coincidence plane to isolate Compton scattering event populations, allowing experimental determination of total detection efficiency values from the measurement of a single mixed isotope standard. A description of the analysis and experimental results of this method are presented.

low background HPGe High Purity Germanium detector↗

Rapid determination of 210 Po in water samples

A new rapid method for the determination of 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that can be used for emergency response or routine water analyses. If a radiological dispersive device (RDD) event or a radiological attack associated with drinking water supplies occurs, there will be an urgent need for rapid analyses of water samples, including drinking water, ground water and other water effluents. Current analytical methods for the assay of 210 Po in water samples have typically involved spontaneous auto-deposition of 210 Po onto silver or other metal disks followed by counting by alpha spectrometry. The auto-deposition times range from 90 minutes to 24 hours or more, at times with yields that may be less than desirable. If sample interferences are present, decreased yields and degraded alpha spectrums can occur due to unpredictable thickening in the deposited layer. Separation methods have focused on the use of Sr Resin, often in combination with 210 Pb analysis. A new rapid method for 210 Po in water samples has been developed at the Savannah River National Laboratory (SRNL) that utilizes a rapid calcium phosphate co-precipitation method, separation using DGA Resin (N,N,N,N-tetraoctyldiglycolamide extractant-coated resin, Eichrom Technologies or Triskem-International), followed by rapid microprecipitation of 210 Po using bismuth phosphate for counting by alpha spectrometry. This new method can be performed quickly with excellent removal of interferences, high chemical yields and very good alpha peak resolution, eliminating any potential problems with the alpha source preparation for emergency or routine samples. A rapid sequential separation method to separate 210 Po and actinide isotopes was also developed. This new approach, rapid separation with DGA Resin plus microprecipitation for alpha source preparation, is a significant advance in radiochemistry for the rapid determination of 210 Po.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in asphalt samples

A new rapid method for the determination of actinides in asphalt samples has been developed that can be used in emergency response situations or for routine analysis If a radiological dispersive device (RDD), Improvised Nuclear Device (IND) or a nuclear accident such as the accident at the Fukushima Nuclear Power Plant in March, 2011 occurs, there will be an urgent need for rapid analyses of many different environmental matrices, including asphalt materials, to support dose mitigation and environmental clean up. The new method for the determination of actinides in asphalt utilizes a rapid furnace step to destroy bitumen and organics present in the asphalt and sodium hydroxide fusion to digest the remaining sample. Sample preconcentration steps are used to collect the actinides and a new stacked TRU Resin + DGA Resin column method is employed to separate the actinide isotopes in the asphalt samples. The TRU Resin plus DGA Resin separation approach, which allows sequential separation of plutonium, uranium, americium and curium isotopes in asphalt samples, can be applied to soil samples as well.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid determination of actinides in seawater samples

A new rapid method for the determination of actinides in seawater samples has been developed at the Savannah River National Laboratory. The actinides can be measured by alpha spectrometry or inductively-coupled plasma mass spectrometry. The new method employs novel pre-concentration steps to collect the actinide isotopes quickly from 80 L or more of seawater. Actinides are co-precipitated using an iron hydroxide co-precipitation step enhanced with Ti +3 reductant, followed by lanthanum fluoride co-precipitation. Stacked TEVA Resin and TRU Resin cartridges are used to rapidly separate Pu, U, and Np isotopes from seawater samples. TEVA Resin and DGA Resin were used to separate and measure Pu, Am and Cm isotopes in seawater volumes up to 80 L. This robust method is ideal for emergency seawater samples following a radiological incident. It can also be used, however, for the routine analysis of seawater samples for oceanographic studies to enhance efficiency and productivity. In contrast, many current methods to determine actinides in seawater can take 1–2 weeks and provide chemical yields of ~30–60 %. This new sample preparation method can be performed in 4–8 h with tracer yields of ~85–95 %. By employing a rapid, robust sample preparation method with high chemical yields, less seawater is needed to achieve lower or comparable detection limits for actinide isotopes with less time and effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid method to determine 89 Sr/ 90 Sr in large concrete samples

Here, a new rapid method has been developed that provides high quality low-level measurements of 89,90 Sr in concrete samples with an MDA (Minimum Detectable Activity) of <1 mBq g -1 . The new method is fast, meets new decommissioning regulatory limits and is robust even if refractory particles are present. The method utilizes a rapid fusion to ensure total dissolution of samples and rapid preconcentration and separation of 89,90 Sr from 5-10 g concrete samples. When, the 89 Sr/ 90 Sr ratio is high, Sr can be isolated from up to 5g concrete samples, total 89/90 Sr measured, and then 90Sr determined via 90 Y separated after a period of ingrowth. Another approach allows the immediate determination of 90 Sr in 10 g concrete aliquots without waiting for 90 Y ingrowth, in instances where the shorter lived 89 Sr is unlikely to be encountered.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Age determination of a 75 Se gamma radiography source for nuclear forensics

Here, two methods were used to evaluate the age of 75 Se sealed source material. Both methods utilized gamma spectroscopy to determine the quantity of parent 75 Se present, but they differed in the technique used to determine the quantity of daughter 75 As. In one method, 75 As was quantified using inductively coupled plasma-mass spectrometry (ICP-MS) after using chromatographic techniques to separate the parent and daughter isotopes. In the other method, total As was measured using optical emission spectroscopy (OES), which did not require separation prior to measurement. The OES method was faster and gave slightly lower uncertainties, but required more daughter material to be present because of higher concentration requirements, making it unsuitable for young material. Both methods are hampered by the monoisotopic nature of As, but still gave reasonable model ages that were in agreement with each other.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chemical separation of 146 Sm for half-life determination

Here, although methods for the chemical separation of samarium from a rock matrix are well established, chemical separation of samarium from non-natural isotopic impurities for the purpose of 146 Sm half-life measurement requires modifications to these procedures, as well as additional checks for effective separation. This work describes the chemical purification procedures associated with the 146 Sm source and the results from gamma spectroscopy. The purification procedure allowed for the quantitative determination of the number of 146Sm atoms using a modified isotope dilution technique. Alpha-decay counting of the sample will be applied in the future to determine the half-life of 146 Sm.

146Sm↗

Determinants of the Price of High-Tech Metals: An Event Study

The growing demand for high-tech products has resulted in strong growth in demand for certain minor metals. In combination with production concentrated in China, this caused strong and unpredicted price movements in recent years. As a result, manufacturing companies have to cope with additional risks. However, the detailed reasons for the price development are only partially understood. Therefore, we analyzed empirically which determinants can be assigned to price movements and performed an event study on the high-tech metals neodymium, indium, and gallium. Based on our dataset of news items, we were able to find coinciding events to almost 90% of all price jumps (recall). We showed that if any information about these events occurred with a probability of over 50% there would also be a price jump within 10 days (precision). However, the classical set of price determinants has to be extended for these specific markets, as we found unorthodox factors like holidays or weather that may be indicators for price movements. Therefore, we hope that our study supports industry for instance in performing more informed short-term planning of metals purchasing based on information about specific events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Simple Colorimetric Determination of the Manganese Content in Photosynthetic Membranes

The functional Mn content of intact photosystem II membrane fragments was measured as 4.06 {+-} 0.13 Mn/reaction center when determined using a simple, sensitive colorimetric assay that will also work with thylakoids and core complexes. This procedure requires minimal sample material, does not need expensive assay equipment, requires four simple steps, and only takes 20-30 min to perform. These include (a) removal of the adventitious Mn ions by CaCl{sub 2} treatment of the membranes, (b) extraction of the Mn from the O{sub 2}-evolving complex with hydrochloric acid, (c) purification of the extract by centrifugation followed by filtration of the supernatant through an Acrodisc syringe filter (0.2 {micro}m nylon membrane), and (d) colorimetric determination of Mn in the extract using the reaction of the chromogenic agent, 3,3',5,5'-tetramethylbenzidine, with previously oxidized Mn(II) cations carried out at high pH. The colorimetric assay itself has been used previously by Serrat (Mikrochim Acta 129:77-80, 1998) for assaying Mn concentrations in sea water and drinking water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Electron Temperature in DA-pHEMT Heterostructures by Shubnikov – de Haas Oscillation Method

The electron temperature of a two-dimensional electron gas heated by an electric field in DA-pHEMT heterostructures was determined by the Shubnikov – de Haas (SdH) oscillation method separately for each size-quantization subband. An analysis of the Fourier spectra of SdH oscillations showed that throughout the entire range of electron temperatures obtained, harmonics associated with different size-quantization subbands and transitions between the Landau levels of these subbands dominate in the spectra. To separate the SdH oscillations into individual harmonics, we used the approximation of the magnetic-field dependences of the oscillations by theoretical expressions using the ratio between the peak heights in the Fourier spectra. It is shown that this method allows one to determine the values of the electron temperature in case when the electron concentrations in the first and second subbands are close in magnitude. The obtained values of the electron temperature correspond to the literature data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Polarization Amplitude-Based Method of Determining the Bearing and Roll Angles of an Object in Motion from Orthogonal Circularly Polarized Signals of a Radio Beacon

The possibility of determining the bearing and roll angles of an object in motion is investigated based on orthogonal left- and right-hand circularly polarized signals simultaneously radiated by a radio beacon from two points with the known coordinates spatially spaced in the horizontal plane. The bearing and roll angles are determined onboard the object in motion using a two-channel receiving system based on polarization amplitude-based processing of resultant vector signals received in a linear polarization basis.

36 MATERIALS SCIENCE↗

Determination of Thermoelastic Properties of Carbon Nanotube/Epoxy Composites Using Finite Element Method

In the present study, three-dimensional finite element (FE) analysis has been performed for determination of thermoelastic properties of carbon nanotube (CNT)/epoxy composites considering both linear and nonlinear stress–strain relations of CNT. A square representative volume element has been considered for the FE analysis (FEA), and the effect of considering nonlinear stress–strain relation of CNT on the prediction of thermoelastic properties has been determined by comparing the results with the theoretical results. Results show that in order to obtain realistic values of thermoelastic properties, the nonlinear stress–strain relation of CNT needs to be used in the FEA. Not considering nonlinear stress–strain relation of CNTs in the FEA may lead to estimating erroneous values of thermoelastic properties of CNT composites which may have adverse effect in the design of structural components made of such composites subjected to thermomechanical loading.

36 MATERIALS SCIENCE↗

Determination of the Frictional Behavior at Compaction of Powder Materials Consisting of Spray-Dried Granules

The frictional behavior during powder compaction and ejection is studied using an instrumented die with eight radial sensors. The average friction over the total powder pillar is used to determine a local friction coefficient at each sensor. By comparing forces at compaction with forces at ejection, it can be shown that the Coulomb’s friction coefficient can be described as a function of normal pressure. Also stick phenomena has been investigated in order to assess its influence on the determination of the local friction coefficient.

36 MATERIALS SCIENCE↗

A Simplified Procedure to Determine Post-necking True Stress–Strain Curve from Uniaxial Tensile Test of Round Metallic Specimen Using DIC

Triaxial state of stress is usually generated in the necked zone because of neck geometry, and as a consequence proper correction of true tensile stress–strain curve after necking is mandatory. Various correction factors like Bridgman, Davidenkov and Spiridonova, Siebel and Schwaigere are available in the published literature to calculate true stress from mean axial stress. Similarly true strains can be calculated from the minimum diameters of the round specimen in the necked region for various true stress levels. But experimental determination of correction factors and minimum diameters of the round specimen in the necked region is a cumbersome task. This investigation shows a simplified procedure to determine true strains and the correction factors from digital image correlation-based local strain measurement in the necked region. The present procedure is validated by experimental results of rail steel.

36 MATERIALS SCIENCE↗

Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data

Purpose: To determine whether the left ventricular ejection fractions (EFs), measured on a high-sensitivity CZT single photon emission computed tomography (SPECT)-camera with a 70% reduction in recording times and a prevention of EF overestimation through an additional count-calibration, are concordant with reference EF from planar radionuclide angiography (2D-RNA). Methods: An additional 10-minute CZT-SPECT recording was performed in patients referred to 2D-RNA for cardiomyopathy (n = 23) or chemotherapy monitoring (n = 50) with an in vivo red blood cell labeling with 850 MBq {sup 99m}TcO{sub 4}{sup −}. The EF, obtained from CZT-SPECT with 100% (SPECT100) or 30% (SPECT30) projection times and with a SPECT-count calibration on the 2D-RNA counts of corresponding cavity volumes, were compared to EF from 2D-RNA. Results: Strong and equivalent relationships were documented between the EF from 2D-RNA and the calibrated EF from SPECT100 (y = 0.89x + 6.62; R{sup 2} = 0.87) and SPECT30 (y = 0.87x + 8.40; R{sup 2} = 0.85), and the mean EF from SPECT100 (54% ± 15%) and SPECT30 (53% ± 16%) were close to that from 2D-RNA (55% ± 15%). However, upward shifts in these mean values were documented in the absence of count calibration for both SPECT100 (60% ± 18%) and SPECT30 (60% ± 18%). Conclusion: Left ventricular EF may be determined on a high-sensitivity CZT-camera, a 70% reduction in injected activities, and an additional count-calibration for further enhancing the concordance with 2D-RNA values. [French] French Abstract: Objectif: Déterminer si les fractions d'éjection ventriculaire gauche (EF) mesurées sur une caméra CZT SPECT à haute sensibilité avec une réduction de 70% des temps d'enregistrement et une prévention de la surestimation de l'EF grâce à un étalonnage supplémentaire des coups concordent avec les EF de référence obtenues par angiographie scintigraphique planaire (2D-RNA). Méthodes: Un enregistrement CZT-SPECT supplémentaire de 10 minutes a été réalisé chez les patients référés pour évaluation de cardiomyopathie (n=23) ou suivi de chimiothérapie (n = 50) par angiographie scintigraphique planaire (2D-RNA) au globules rouges marqués avec 850 MBq 99mTcO4-. Les EF, obtenues au moyen d’une caméra CZT-SPECT avec 100% (SPECT100) ou 30% (SPECT30) de temps d’acquisition et avec étalonnage des coups SPECT sur les images 2D-RNA des volumes de cavité correspondants ont été comparés aux EF à partir de 2D-RNA. Résultats: une corrélation significative existe entre les EF obtenues par 2D-RNA et les EF étalonnées obtenues par SPECT100 (y = 0,89x + 6,62; R2 = 0,87) et SPECT30 (y = 0,87x + 8,40; R2 = 0,85). Les EF moyennes de SPECT100 (54 ± 15%) et SPECT30 (53 ± 16%) sont similaires à celles obtenues par 2D-RNA (55 ± 15%). En l'absence d'étalonnage de comptage des études SPECT100 (60 ± 18%) et SPECT30 (60 ± 18%), ces valeurs moyennes d’EF sont généralement plus élevées. Conclusion: La fonction ventriculaire gauche peut être déterminée avec une caméra CZT à haute sensibilité, une réduction des activités injectées et un étalonnage supplémentaire des coups pour améliorer la concordance avec les valeurs obtenues par 2D-RNA. [Spanish] Spanish Abstract: Propósito: Determinar si la fracción de eyección del ventrículo izquierdo, medida con la cámara CZT-SPECT con una reducción del 70% en tiempo de grabación y con la prevención de la sobreestimación mediante una calibración de cuentas adicional, que sea concordante con el valor referencia de fracción de eyección mediante radiografía planar de radionucleidos. (2D-RNA). Métodos: Una grabación adicional de 10 minutos con CZT-SPECT se realizo en pacientes referidos a radiografía planar de radionucleidos (2D-RNA) por miocardiopatías. (n = 23) o para monitorizar las quimioterapias (n = 50) con marcaje de glóbulos rojos con 850 MBq 99m TcO4. La fracción de eyección obtenida por CZT-SPECT con 100% (SPECT100) o 30% (SPECT30) de tiempo de proyección, y con SPECT con calibración de cuentas con el 2D-RNA, los volúmenes de cavidades fueron comparados con fracción de eyección . Relaciones fuertes y equivalentes fueron documentados entre fracción de eyección del 2D-RNA, y la forma calibrada de la fracción de eyección SPECT100 (y = 0.89x + 6.62; R2 = 0.87) y SPECT30 y = 0.87x + 8.40; R2 = 0.85), y la media de fracción de eyección de SPECT100 (54 ± 15%) and SPECT30 (53 ± 16%) fueron cercanos a la de el 2D-RNA (55 ± 15%). Aunque, aumentos en estas medias se documentaron en la ausencia de la calibración de cuentas para SPECT100 (60 ± 18%) y SPECT30 (60 ± 18%). Conclusión: La fracción de eyección del ventrículo izquierdo puede ser determinada con una cámara CZT de alta sensibilidad, una reducción del 70% en actividades inyectadas y la calibración de cuentas adicional para realzar la concordancia con los valores de 2D-RNA. [Chinese] Chinese Abstract: 目的: 以平面放射性核素血管造影 (2D-RNA) 测定左心室射血分数 (EF) 作为参考标准,为确定利用高灵敏度 CZT SPECT 相机在减少 70% 的记录时间, 并结合计数校准防止高估情况下测量的 EF值, 是否与 2D-RNA 测得的 EF 值一致。 方法: 对心肌病 (n = 23) 或化疗监测 (n = 50) 的患者采用体内标记法注射 850 MBq {sup 99m}TcO{sub 4} 标记的红细胞进行 2D-RNA ,随后再采集 10 分钟 CZT-SPECT。 对 CZT-SPECT 100% 投影时间 (SPECT100) 或 30% 投影时间 (SPECT30) 获得的图像进行重建, 并进行计数校准 (对相应容积获得的 2D-RNA 计数通过 SPECT 校准)获得 EF 值, 与 2D-RNA 测定的 EF 的进行比较。 结果: 2D-RNA 测定的 EF 值与 SPECT100 校准后测定的 EF 值 (y = 0.89x + 6.62; R{sup 2} = 0.87) 及 SPECT30 (y = 0.87x + 8.40; R{sup 2} = 0.85) 校准后 EF 值具有高度相关性, 并且 SPECT100 (54 ± 15%) 和 SPECT30 (53 ± 16%) 测定的 EF 平均值与 2D-RNA 测定的 EF 平均值 (55 ± 15%) 非常接近。 但是, 在没有计数校准的情况下, SPECT100 (60 ± 18%) 和 SPECT30 (60 ± 18%) 测定的 EF 平均值会被高估。 结论: 高灵敏度 CZT 相机可在减少 70% 的注射剂量情况下测定左心室 EF 值, 结合计数校准可进一步提高与 2D-RNA测得的 EF 值的一致性。 关键词: 放射性核素血管造影; 血池 SPECT; CZT 相机; 左心室射血分数; 校准曲线。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗