Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Radiological patterns of secondary sclerosing cholangitis in patients after lung transplantation

Purpose: The purpose of this study was to investigate the radiological patterns of secondary sclerosing cholangitis (SSC) following lung transplantation. Methods: Fifty-five patients underwent abdominopelvic CT before and after lung transplantation for end stage pulmonary disease. Nine patients underwent MR cholangiopancreatography (MRCP). The radiological patterns of biliary abnormalities (location, bile duct dilatation with stricture, beaded appearance, and biliary casts/sludge), laboratory data (serum total bilirubin and alkaline phosphatase), and patient survival rates were evaluated. SSC was diagnosed when there were newly developed biliary abnormalities with cholestasis after lung transplantation. Potential perioperative risk factors pertaining to SSC were analyzed. Patient survival rates with or without SSC were compared. Results: Six of the 55 patients showed imaging and laboratory findings of SSC after lung transplantation. Multifocal dilatation and stricture involved the intrahepatic (6 of 6, 100%), hilar (4 of 6, 66.7%), and extrahepatic bile duct (1 of 6, 16.7%). On CT, the lesions presented as multifocal small cyst-like lesions along the bile duct course. On MRCP, the lesions showed beaded appearance with mild duct dilatation. Preoperative mechanical ventilation and bilateral lung transplantation were associated with SSC (p < 0.05). The median survival of patients with SSC was 4.6 months. Conclusion: Lung transplantation can induce SSC similar to SSC in critically ill patients, and result in worse clinical outcomes than in patients without SSC. Multifocal small cyst-like lesions along the intrahepatic bile duct on CT and beaded appearance on MRCP are suggestive findings of SSC in patients with cholestasis after lung transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of biliary anatomy in the caudate lobe using drip infusion cholangiography-computed tomography

Purpose: This study aimed to retrospectively evaluate the caudate branches (CBs), which are bile ducts originating from the caudate lobe (CL), using drip infusion cholangiography with computed tomography (DIC-CT). Methods: The confluence patterns of CBs were evaluated in 185 adult patients undergoing DIC-CT. The following bile duct features were evaluated: (a) number of depicted CBs; (b) identification of the caudate portion from which the CBs were derived; (c) identification of the confluence site of a CB; and (d) whether there was a difference in the confluence site of the CBs depending on the position of the right posterior hepatic duct (RPHD) and the portal vein (PV). Results: DIC-CT enabled detection of a total of 640 bile ducts from the CL in 185 patients, and the total number of CBs from the Spiegel lobe (SP), the paracaval portion, and the caudate process (CP) were 347 (54.2%), 112 (17.5%), and 181 (28.2%), respectively. In the SP, over 60% of CBs joined the left hepatic duct system (LHDS). The positional relationship between the RPHD and the PV was divided into a supra-portal course (n = 168) and an infra-portal course (n = 17). The number of CBs joining the LHDS was significantly different between a supra-portal course and an infra-portal course (p = 0.0484). Conclusion: CBs were depicted by DIC-CT in 98.9% of the subjects, and a detailed evaluation was possible. The number of CBs joining the LHDS was associated with the position of the RPHD and the PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of the Idaho National Laboratory Hot Fuel Examination Facility Stack Monitoring Site for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to determine whether the location of the air sampling probe in the Hot Fuels Examination Facility (HFEF) heating, ventilation and air conditioning (HVAC) exhaust duct meets the applicable regulatory criteria regarding the placement of an air sampling probe. Federal regulations require that a sampling probe be located in the exhaust stack according to the criteria of the ANSI/HPS N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stacks and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that is representative of the effluent stream. The tests conducted by PNNL during July 2010 on the HFEF system are described in this report. The sampling probe location is approximately 20 feet from the base of the stack. The stack base is in the second floor of the HFEF, and has a building ventilation stream (limited potential radioactive effluent) as well as a process stream (potential radioactive effluent, but HEPA-filtered) that feeds into it. The tests conducted on the duct indicate that the process stream is insufficiently mixed with the building ventilation stream. As a result, the air sampling probe location does not meet the criteria of the N13.1-1999 standard. The series of tests consists of various measurements taken over a grid of points in the duct cross section at the proposed sampling-probe location. The results of the test series on the HFEF exhaust duct as it relates to the criteria from ANSI/HPS N13.1-1999 are desribed in this report. Based on these tests, the location of the air sampling probe does not meet the requirements of the ANSI/HPS N13.1-1999 standard, and modifications must be made to either the HVAC system or the air sampling probe for compliance. The recommended approaches are discussed and vary from sampling probe modifications to modifying the junction of the two air exhaust streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Analysis of a Modular Small-Diameter Air Distribution System

This report investigates the feasibility of using a home-run manifold small-diameter duct system to provide space-conditioning air to individual thermal zones in a low-load home. This compact layout allows duct systems to easily be brought within conditioned space via interior partition walls. Centrally locating the air handling unit in the house significantly reduces duct lengths. The plenum box is designed so that each connected duct receives a similar amount of airflow—regardless of its position on the box. Furthermore, within a reasonable set of length restrictions each duct continues to receive similar airflow.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Room Return Path Sensitivity

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms. In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology–or layout–impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This report considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR

California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) Building Technologies Program. The Roof Savings Calculator (RSC) tool is designed to help building owners, manufacturers, distributors, contractors and practitioners easily run complex simulations. The latest web technologies and usability design were employed to provide an easy input interface to an annual simulation of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim. Building defaults were assigned based on the best available statistical evidence and can provide energy and cost savings after the user selects nothing more than the building location. A key goal for the tool is to promote the energy benefits of cool color tile, metal and asphalt shingle roof products and other energy saving systems. The RSC tool focuses on applications for the roof and attic; however, the code conducts a whole building simulation that puts the energy and heat flows of the roof and attic into the perspective of the whole house. An annual simulation runs in about 30 sec. In addition to cool reflective roofs, the RSC tool will simulate high- medium- and low-slope roofs, and has a custom selection for the user whose house has a unique inclination. There is an option for above sheathing ventilation, which is prevalent in tile and stone-coated metal roof assemblies. The tool also accommodates the effects of radiant barriers and low-emittance surfaces in the inclined air space above the sheathing. The practitioner can select to have air-conditioning ducts either in the conditioned space or in the attic. If in the attic, the user can select one of three air leakage options. Option 1 is an inspected duct having 4% leakage and code level of duct insulation; option 2 is a poorly insulated duct having 14% air leakage; and option 3 is a custom leakage rate specified by the user. The practitioner can setup multiple layers of ceiling insulation. AtticSim is benchmarked against the field data acquired for Ft. Irwin located near Barstow, CA, first as a standalone simulation program and then again integrated within the DOE-2.1E program. The standalone benchmark was very useful to determining how well AtticSim replicates the building physics of an attic. The coupled benchmark was useful to verify that the DOE-2.1E/AtticSim code is modeling correctly the dynamic relationship between the attic and the occupied space below, as well as the interactions between the attic and the HVAC system, in particular when the ducts are located in the attic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

Cleanup and Dismantling of Highly Contaminated Ventilation Systems Using Robotic Tools - 13162

The UP1 plant reprocessed nearly 20,000 tons of used natural uranium gas cooled reactor fuel coming from the first generation of civil nuclear reactors in France. Following operating incidents in the eighties, the ventilation system of the continuous dissolution line facility was shut down and replaced. Two types of remote controlled tool carriers were developed to perform the decontamination and dismantling operations of the highly contaminated ventilation duct network. The first one, a dedicated small robot, was designed from scratch to retrieve a thick powder deposit within a duct. The robot, managed and confined by two dedicated glove boxes, was equipped for intervention inside the ventilation duct and used for carrying various cleanup and inspection tools. The second type, consisting of robotic tools developed on the base of an industrial platform, was used for the clean-up and dismantling of the ventilation duct system. Depending on the type of work to be performed, on the shape constraints of the rooms and any equipment to be dismantled, different kinds of robotic tools were developed and installed on a Brokk 40 carrier. After more than ten years of ventilation duct D and D operations at the UP1 plant, a lot of experience was acquired about remote operations. The three main important lessons learned in terms of remote controlled operation are: characterizing the initial conditions as much as reasonably possible, performing non-radioactive full scale testing and making it as simple and modular as possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Emissions from ethanol-blended fossil fuel flames

A fundamental study to investigate the emission characteristics of ethanol-blended fossil fuels is presented. Employing a heterogeneous experimental setup, emissions are measured from diffusion flames around spherical porous particles. Using an infusion pump, ethanol-fossil fuel blend is transpired into a porous sphere kept in an upward flowing air stream. A typical probe of portable digital exhaust gas analyzer is placed in and around the flame with the help of a multi-direction traversing mechanism to measure emissions such as un-burnt hydrocarbons, carbon monoxide and carbon dioxide. Since ethanol readily mixes with water, emission characteristics of ethanol-water blends are also studied. For comparison purpose, emissions from pure ethanol diffusion flames are also presented. A simplified theoretical analysis has been carried out to determine equilibrium surface temperature, composition of the fuel components in vapor-phase and heat of reaction of each blend. These theoretical predictions are used in explaining the emission characteristics of flames from ethanol blends. (author) This paper presents the results of an experimental study of flow structure in horizontal equilateral triangular ducts having double rows of half delta-wing type vortex generators mounted on the duct's slant surfaces. The test ducts have the same axial length and hydraulic diameter of 4 m and 58.3 mm, respectively. Each duct consists of double rows of half delta wing pairs arranged either in common flow-up or common flow-down configurations. Flow field measurements were performed using a Particle Image Velocimetry Technique for hydraulic diameter based Reynolds numbers in the range of 1000-8000. The secondary flow field differences generated by two different vortex generator configurations were examined in detail. The secondary flow is found stronger behind the second vortex generator pair than behind the first pair but becomes weaker far from the second pair in the case of Duct1. However, the strength of the secondary flow is found nearly the same behind the first and the second vortex generator pair as well as far from the second vortex generator pair in the case of Duct2. Both ducts are able to create a counter-rotating and a second set of twin foci. Duct2 is able to create the second set of twin foci in an earlier streamwise location than Duct1, as these foci are well-known to their heat transfer augmentation. A larger vortex formation area and a greater induced vorticity field between vortex pairs are observed for Duct2 compared with Duct1. As the induced flow field between the vortex pairs increases the heat transfer, and as the flow field between the vortex cores is found larger in the case of Duct2, therefore, it is expected to obtain better heat transfer characteristics for Duct2 compared with Duct1. (author)

09 BIOMASS FUELS↗

Radiation-Induced Damage to Microstructure of Parotid Gland: Evaluation Using High-Resolution Magnetic Resonance Imaging

Purpose: To elucidate the radiation-induced damage to the microstructure of the parotid gland using high-resolution magnetic resonance imaging. Methods and Materials: High-resolution magnetic resonance imaging of the parotid gland was performed before radiotherapy (RT) and during the RT period or {<=}3 weeks after RT completion for 12 head-and-neck cancer patients using a 1.5-T scanner with a microscopy coil. The maximal cross-sectional area of the gland was evaluated, and changes in the internal architecture of the gland were assessed both visually and quantitatively. Results: Magnetic resonance images were obtained at a median parotid gland dose of 36 Gy (range, 11-64). According to the quantitative analysis, the maximal cross-sectional area of the gland was reduced, the width of the main duct was narrowed, and the intensity ratio of the main duct lumen to background was significantly decreased after RT (p <.0001). According to the visual assessment, the width of the main duct tended to narrow and the contrast of the duct lumen tended to be decreased, but no significant differences were noted. The visibility of the duct branches was unclear in 10 patients (p = .039), and the septum became dense in 11 patients (p = .006) after RT. Conclusion: High-resolution magnetic resonance imaging is a noninvasive method of evaluating radiation-induced changes to the internal architecture of the parotid gland. Morphologic changes in the irradiated parotid gland were demonstrated during the RT course even when a relatively small dose was delivered to the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Additively Manufactured Complex Tools for Autoclave Cure Composites

IACMI Project 4.9, Tooling for Composites with Washout Features Produced by Additive Manufacturing, assembled a team including the industry lead, Ability Composites, NREL and Colorado State University (CSU). Ability Composites had originally expressed interest in alternate methods of producing tooling for composite parts. In follow-up discussions, it became clear that one of the bigger tooling challenges revolved around small production volume composite parts that were tooled on washout material due to the complex geometry. To build an understanding of the potential, both from a technology and a cost perspective, for replacing conventional washout tooling with 3D printed thermoplastic tooling, a number of commercially available dissolvable FDM printing materials were evaluated, leading to tooling representative of commercial articles of interest to Ability Composites. Ultimately, Ability Composites was able to directly compare autoclave processed prepreg composite parts produced on conventional washout tooling to composite parts molded on 3D printed dissolvable tooling produced at CSU. Small, laboratory test specimens were developed to investigate the structural performance of the candidate materials under autoclave processing conditions, which were nominally 121 °C (250 °F) and 345 kPa (50 psi). In addition, several internal structural configurations (infills) were evaluated under autoclave conditions using model materials. The results of these tests indicated that two materials, Stratasys ST 130 and Infinite Materials Solutions Aquasys 180 (AQ 180), were the best candidates, given the specified autoclave processing conditions. ST-130 was slightly more robust than AQ-180; however, the AQ-180 was carried forward as it was dissolvable in water, not requiring the basic solution needed to dissolve ST-130. Based on the preliminary material and 3D printed structures evaluations, larger tools with a truncated square pyramid geometry were created to produce prepreg composite test articles for 3D printed dissolvable tool evaluation under standard autoclave fabrication conditions. Two tools were manufactured using ST-130 and one tool using traditional ceramic washout tooling media. The tools were evaluated for geometric fidelity and surface roughness changes before and after carbon fiber/epoxy prepreg composites were manufactured on the tooling. The autoclave processing did not impact the geometry significantly and was completed at 121 °C and 345 kPa, indicating satisfactory tool performance. The results from surface roughness testing of both the resulting composite and the associated tooling indicated that an adequate surface resulted without the need for a surface sealing step, as was required for the conventional washout tooling. Based on results of the truncated pyramid tests as a basis, ST-130, AQ-120 and AQ-180 materials were carried forward to the tool geometry of interest to Ability Composites. These hollow rectangular bent ducts, which were complex in nature and not extractable after cure, were used to understand the impacts of tool material and thickness. One ST-130 tool was produced as a partially solid part, with an enclosed 40% dense infill region to reduce weight and material use. This was the same approach evaluated in the truncated pyramid portion of the study. This tool was to be envelope vacuum bagged and directly compared to a monolithic tool of conventional washout material. The traditional monolithic ceramic tool was manufactured by Ability composites using CNC-based subtractive methods. An additional five dissolvable polymer tools, manufactured from ST-130, AQ-120, and AQ-180, using a hollow design were 3D printed and used to produce carbon fiber/epoxy composite evaluation articles. These hollow dissolvable tools were expected to be less influenced by the autoclave conditions as the wall was solid and vacuum bagging was inside and outside the tool. This alternative geometry was also evaluated as an option in techno-economic modeling. Print times were reduced from in excess of 3 days to under 30 hours, while surface quality and and tool integrity were substantially improved in the transition from the partially solid tool to the hollow tooling concept. Ability Composites produced autoclave-cured prepreg ducts on each of these tools. The autoclave conditions utilized were more severe than those of the initial trials, reaching temperatures of 160 °C and a pressure of 414 kPa. Under these conditions, the partially solid 3D printed tool with skin and 40% dense infill crushed significantly; however, the thicker ST-130 hollow tool showed good promise, deforming only slightly. The thinner hollow tool walls were unsuccessful as were the other materials. Overall, the hollow tool manufacturing process saved significant amounts of time and material in manufacturing as compared to the solid ducts and produced composite surface quality improvements compared to the traditional washout tooling. The TEM was developed to allow direct comparisons between conventional washout tool manufacturing processes and those developed at CSU. It also allowed for two separate 3D printed tool geometries to be analyzed and compared. In this case, the square bent duct tool geometry was determined to be representative of common washout tools. This geometry was compared with a scaled-up version of it to assess differences in the two manufacturing processes based on tool size. The model was developed to make use of user input in the form of geometry details, process steps, manufacturing parameters, bulk material costs, capital equipment costs, and general costs to calculate overall labor, material, capital equipment, and energy costs per manufactured tool for the conventional and additive manufacturing processes for the two representative geometries. It was also able to estimate step-by-step process times for the manufacturing process and geometries. Based on significant input from Ability Composites and CSU from their knowledge gained from hands-on manufacturing of the 3D printed bent duct tool geometry, costs and process times were calculated for the two manufacturing processes. Results showed that the additive manufacturing techniques developed at CSU can substantially reduce the costs of tool manufacturing by reducing labor times and material usage. This is because additive manufacturing is a relatively hands-off process and allows for the tool design to be optimized to reduce material usage. The disadvantage, however, is that process times for additive manufacturing are significantly longer. The three-dimensional (3D) printing process is slow if tight tolerances are required, but the analysis did show that print times could be reduced with the hollow tool geometry. Also, further advances in additive manufacturing could expedite the process. Costs and process times for the tool washout process were calculated separately. They showed that costs are relatively insignificant when compared to the overall tool manufacturing processes, but with increases in tool size, costs for the conventional manufacturing approach are larger than for additive manufacturing. Again, the washout process for conventional tools is very hands-on, whereas for additively manufactured tools the print medium is dissolved in an automated detergent bath at the sacrifice of process time. The analysis showed that optimizing the additively manufactured tools may also reduce washout times. Overall, Project 4.9 demonstrated that commercially available dissolvable 3D printing materials exist that can be used to produce dissolvable tooling capable of surviving prepreg composites fabrication under autoclave conditions of 121 °C (250 °F) and 345 kPa (50 psi). An alternative hollow dissolvable tool design was developed which was structurally superior to the initial concept and was cost and time effective versus conventional washout tooling. The 3D printed sacrificial tool required no added surface sealing steps prior to composite part layup and cure, offering a significant advantage over the porous conventional washout tooling.

36 MATERIALS SCIENCE↗

Influence of fuel temperature on supersonic mixing and combustion of hydrogen

Results are presented from an experimental investigation of the influence of fuel stagnation temperature on the mixing and reaction of hydrogen injected transverse to a supersonic flow in a duct. The hydrogen fuel was injected stoichiometrically at stagnation temperatures of 300 K and 800 K from a row of five circular orifices in the duct wall. Detailed measurements in the flow at the duct exit are used to determine the overall amount of mixing accomplished at each of three test conditions. Static pressure distributions are used with duct wall temperatures and heat flux in a one-dimensional analysis to deduce the fraction of fuel reacted along the duct. Results from the one-dimensional analyses of the tests with hot fuel indicated slightly more fuel reacted at the exit; however, differences in the accomplished mixing obtained from integrations of exit surveys were small.

Rogers, R. C.↗

A new blade element method for calculating the performance of high and intermediate solidity axial flow fans

A method is presented to design and predict the performance of axial flow rotors operating in a duct. The same method is suitable for the design of ducted fans and open propellers. The unified method is based on the blade element approach and the vortex theory for determining the three dimensional effects, so that two dimensional airfoil data can be used for determining the resultant force on each blade element. Resolution of this force in the thrust and torque planes and integration allows the total performance of the rotor, fan or propeller to be predicted. Three different methods of analysis, one based on a momentum flow theory; another on the vortex theory of propellers; and a third based on the theory of ducted fans, agree and reduce cascade airfoil data to single line as a function of the loading and induced angle of attack at values of constant inflow angle. The theory applies for any solidity from .01 to over 1 and any blade section camber. The effects of the duct and blade number can be determined so that the procedure applies over the entire range from two blade open propellers, to ducted helicopter tail rotors, to axial flow compressors with or without guide vanes, and to wind tunnel drive fans.

Borst, H. V.↗

The effects of air leaks on solar air heating systems

This paper presents the results of an investigation to determine the effects of leakages in collector and duct work on the system performance of a typical single-family residence solar air heating system. Positive (leakage out) and negative (leakage in) pressure systems were examined. Collector and duct leakage rates were varied from 10 to 30 percent of the system flow rate. Within the range of leakage rates investigated, solar contribution to heated space and domestic hot water loads was found to be reduced up to 30 percent from the no-leak system contribution with duct leakage equally divided between supply and return duct; with supply duct leakage greater than return leakage a reduction of up to 35 percent was noted. The negative pressure system exhibited a reduction in solar contribution somewhat larger than the positive pressure system for the same leakage rates.

Elkin, R.↗

Investigation of Aerodynamic and Icing Characteristics of Water-Inertia-Separation Inlets for Turbojet Engines

The results of an investigation of several internal water-inertia-separation inlets consisting of a main duct and an alternate duct designed to prevent automatically the entrance of large quantities of water into a turbojet engine in icing conditions are presented. Total-pressure losses and icing characteristics for a direct-ram inlet and the inertia-separation inlets are compared at similar aerodynamic and simulated icing conditions. Complete ice protection for inlet guide vanes could not be achieved with the inertia-separation inlets investigated. Approximately 8 percent of the volume of water entering the nacelles remained. In the air passing into the compressor inlet. Heavy alternate-duct-elbow ice formations caused by secondary inertia separation resulted in rapid total-pressure losses and decreases in mass flow. The duration in an icing condition for an inertia-separation- inlet, without local surface heating, was increased approximately four times above that for a direct-ram inlet with a compressor-inlet screen. For normal nonicing operation, the inertia-separation- inlet total-pressure losses were comparable to a direct-ram installation. The pressure losses and the circumferential uniformity of the mass flow in all the inlets were relatively independent of angle of attack. Use of an inertia-separation inlet would in most cases require a larger diameter nacelle than a direct-ram inlet in order to obtain an alternate duct sufficiently large to pass the required engine air flow at duct Mach numbers below 1.0 at the minimum area.

VonGlahn, Uwe↗

Maximum Evaporation Rates of Water Droplets Approaching Obstacles in the Atmosphere Under Icing Conditions

When a closed body or a duct envelope moves through the atmosphere, air pressure and temperature rises occur ahead of the body or, under ram conditions, within the duct. If cloud water droplets are encountered, droplet evaporation will result because of the air-temperature rise and the relative velocity between the droplet and stagnating air. It is shown that the solution of the steady-state psychrometric equation provides evaporation rates which are the maximum possible when droplets are entrained in air moving along stagnation lines under such conditions. Calculations are made for a wide variety of water droplet diameters, ambient conditions, and flight Mach numbers. Droplet diameter, body size, and Mach number effects are found to predominate, whereas wide variation in ambient conditions are of relatively small significance in the determination of evaporation rates. The results are essentially exact for the case of movement of droplets having diameters smaller than about 30 microns along relatively long ducts (length at least several feet) or toward large obstacles (wings), since disequilibrium effects are then of little significance. Mass losses in the case of movement within ducts will often be significant fractions (one-fifth to one-half) of original droplet masses, while very small droplets within ducts will often disappear even though the entraining air is not fully stagnated. Wing-approach evaporation losses will usually be of the order of several percent of original droplet masses. Two numerical examples are given of the determination of local evaporation rates and total mass losses in cases involving cloud droplets approaching circular cylinders along stagnation lines. The cylinders chosen were of 3.95-inch (10.0+ cm) diameter and 39.5-inch 100+ cm) diameter. The smaller is representative of icing-rate measurement cylinders, while with the larger will be associated an air-flow field similar to that ahead of an airfoil having a leading-edge radius comparable with that of the cylinder. It is found that the losses are less than 5 percent. It is concluded that such losses are, in general, very small (less than 1 percent) in the case of smaller obstacles (of icing-rate measurement- cylinder size); the motional dynamics are such, however, that exceptions will occur by reason of failure of very small droplets (moving along stagnation lines) to impinge upon obstacle surfaces. In such cases, the droplets will evaporate completely.

Lowell, H. H.↗