Status of the measurement of the muon neutrino charged-current coherent pion production in the NOvA near detector [Slides]
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
ProtoDUNE Single-Phase is a 700-ton liquid argon detector operated in the CERN Neutrino Platform from 2018 to 2020. It is part of the Deep Underground Neutrino Experiment (DUNE), a long-baseline neutrino oscillation experiment with a 40 kT liquid argon far detector to be built at the Sanford Underground Research Facility and a near detector, with both argon and non-argon detector technologies, to be hosted at the Fermi National Accelerator Laboratory. A critical uncertainty to understand in the neutrino oscillation program of DUNE is the uncertainty on final state interactions, either reaction or elastic, of various hadrons on argon since the scattering of neutrino-induced hadrons off argon bias the hadron's measured energy. It can also prevent algorithms from identifying the hadron's particle type. Protons, kaons, and pions from the beam are especially important for the DUNE neutrino program as they represent common final state particles in neutrino interactions off a nucl eus. Therefore, ProtoDUNE is analyzing the test beam data to measure cross sections of pions, protons, and kaons on argon, aiming to tune parameters that model charged particle scattering off argon. This talk will discuss the data-taking program for ProtoDUNE and an overview of the status and results of measuring cross sections of pions, protons, and kaons on argon. It will conclude with a brief overview of how these measurements can be used for future liquid argon neutrino detectors.
Harnessing sub-eV energy excitations from light dark matter interaction with a target material is one of the challenges in exploring promising novel materials for dark matter searches. In polar materials like sapphire, dark matter interaction can excite sub-eV optical phonon modes. Furthermore, the anisotropy of sapphire crystal could provide a signature of daily modulation of the dark matter scattering rate, making it a promising target material. We plan to utilize superconducting qubits on a sapphire substrate to take advantage of the excitation of phonons, which scatter and further down-convert to lower-energy phonons. A good fraction of these phonons are expected to reach the qubit superconductor on the substrate and break Cooper pairs. Such a process can cause qubit decoherence, which can be measured using standard qubit readout protocol. In this talk, we describe our ongoing attempt to build such a prototype detector.
This note presents the status of the measurement of electron neutrinos from the Fermilab Booster Neutrino Beamline (BNB) with the MicroBooNE experiment. The analysis is aimed at investigating the nature of the low energy excess of electromagnetic activity observed by the MiniBooNE experiment. The $ν_e$ event selection relies on topological and calorimetric information to characterise particles produced in these interactions, leveraging the Pandora multi-algorithm reconstruction framework as well as custom particle identification and pattern recognition tools. Results presented in this note use 5.88 × 10 20 protons on target of data collected between 2015 and 2018. These include the performance of particle identification tools for $\mu/p$ and $e/\gamma$ separation, along with electromagnetic shower calibration with the largest sample of $\pi^0$ events measured on argon. Progress towards the completion of this analysis is shown through the measurement of high-energy charged-current $ν_e$ interactions and their kinematic distributions using both inclusive (1eX) and exclusive (1$e$0$p$0$\pi$ and 1$e$N$p$0$\pi$) channels. Measurements of charged-current $ν_µ$ interactions aimed at constraining flux and cross-section systematic uncertainties are also shown. We present the analysis’ preliminary sensitivity of an electron-like signal hypothesis to the MiniBooNE excess which includes flux, cross-section, and detector systematic uncertainties.
Post measurement synchronization of noise signals allowed for the investigation of previously unseen correlations. Noise of gamma, thermal and fast neutron signals performed similarly in estimating the prompt neutron decay constant at various subcritical states. The CPSD amplitude terms displayed different magnitudes. The neutron-based amplitudes suffered more from changes in detector efficiency as the number of fuel rods in the system increased. The time lag between 3 He tubes is observable using the CPSD phase angle and agreed with a simplified diffusion estimation.
Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target. The neutrons scattered and thermalized within the target and were counted as a function of time using Helium-3 ( 3 He) detectors that surrounded the target. These data provide a time-decay profile of the neutron population from which the time eigenvalue of the experiment is calculated. The time eigenvalue quantity α represents the integral parameter of interest. This report describes the measurements for H 2 O targets. The measurements were conducted over several days beginning on October 23rd, 2023. All measurements were completed at the low-scatter facility at LLNL. The evaluation identifier is FUND-LLNL-DT-H2O-PNDA-001.
Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target.
The Short-Baseline Near Detector (SBND) is a liquid argon time projection chamber (LArTPC) neutrino detector in the Short-Baseline Neutrino (SBN) program at Fermilab. SBND is designed to investigate the Low-Energy Excess (LEE), an unexplained excess of electron-like events observed by previous short-baseline neutrino experiments that may point to physics beyond the Standard Model. In LArTPC detectors, precise shower reconstruction is essential for distinguishing electrons from photons, a key requirement for testing possible explanations of the LEE and improving $\nu_e$ event selection. In this poster, the reconstruction studies using the Scalable Particle Imaging with Neural Embeddings (SPINE), a machine learning based reconstruction framework for particle imaging detectors will be presented. SPINE combines sparse convolutional neural networks (CNN) and graph neural networks (GNN) to enable detailed reconstruction and characterization of neutrino interactions in LArTPC detectors. Shower calorimetry and kinematic reconstruction are performed in dedicated post-processing stages. Strong agreement between data and Monte Carlo simulation will be demonstrated, indicating high-precision detector calibration and reconstruction performance. The agreement between reconstructed and true electron shower energy will also be discussed, emphasizing the robustness of the shower reconstruction performance. These results demonstrate the unprecedented precision achievable with SPINE in SBND, highlighting their potential for future high-resolution neutrino measurements.
Almost from the moment in June 1977 when the discovery of the Upsilon resonance revealed the existence of what we now call the bottom quark, physicists began searching for its partner. Through the years, as we established the electric charge and weak isospin of the b-quark, and detected the virtual influence of its mate, it became clear that the top quark must exist. Exactly at what mass, we couldn't say, but we knew just how top events would look. We also knew that top events would be rare--if the Tevatron could make them at all--and that picking out the events would pose a real challenge for the experimenters and their detectors.
Th is paper is motivated by the growing importance of better understanding of the phenomena and consequences of high-intensity energetic particle beam interactions with accelerator, generic target, and detector components. It reviews the principal physical processes of fast-particle interactions with matter, effects in materials under irradiation, materials response, related to component lifetime and performance, simulation techniques, and methods of mitigating the impact of radiation on the components and environment in challenging current and future applications.
The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.
The volume contains recommendations for space-and ground-based programs in gravitational physics, cosmology, and cosmic-ray physics. The section on gravitation examines current and planned experimental tests of general relativity; the theory behind, and search for, gravitational waves, including sensitive laser-interferometric tests and other observations; and advances in gravitation theory (for example, incorporating quantum effects). The section on cosmology deals with the big-bang model, the standard model from elementary-particle theory, the inflationary model of the Universe. Computational needs are presented for both gravitation and cosmology. Finally, cosmic-ray physics theory (nucleosynthesis, acceleration models, high-energy physics) and experiment (ground and spaceborne detectors) are discussed.
The angular accuracy of gamma-ray detectors is intrinsically limited by the physical processes involved in photon detection. Although a number of pointlike sources were detected by the COS B satellite, only two have been unambiguously identified by time signature with counterparts at longer wavelengths. By taking advantage of the extended longitudinal structure of VHE gamma-ray showers, measurements in the TeV energy range can pinpoint source coordinates to arcminute accuracy. This has now been demonstrated with new data analysis procedures applied to observations of the Crab Nebula using Cherenkov air shower imaging techniques. With two telescopes in coincidence, the individual event circular probable error will be 0.13 deg. The half-cone angle of the field of view is effectively 1 deg.
The angular accuracy of gamma-ray detectors is intrinsically limited by the physical processes involved in photon detection. Although a number of point-like sources were detected by the COS-B satellite, only two were unambiguously identified by time signature with counterparts at longer wavelengths. By taking advantage of the extended longitudinal structure of Very High Energy gamma-ray showers, measurements in the TeV energy range can pinpoint source coordinates to arc minute accuracy. This was demonstrated using Cerenkov air shower imaging techniques. With two telescopes in coincidence, the individual event circular probable error will be 0.13 deg. The half-cone angle of the field of view is effectively 1 deg.
The Juno Mission was selected in the summer of 2005 via NASA's New Frontiers competitive AO process (refer to http://www.nasa.gov/home/hqnews/2005/jun/HQ_05138_New_Frontiers_2.html). The Juno project is led by a Principle Investigator based at Southwest Research Institute [SwRI] in San Antonio, Texas, with project management based at the Jet Propulsion Laboratory [JPL] in Pasadena, California, while the Spacecraft design and Flight System Integration are under contract to Lockheed Martin Space Systems Company [LM-SSC] in Denver, Colorado. the payload suite consists of a large number of instruments covering a wide spectrum of experimentation. The science team includes a lead Co-investigator for each one of the following experiments: A Magnetometer experiment (consisting of both a FluxGate Magnetometer (FGM) built at Goddard Space Flight Center GSFC] and a Scalar Helium Magnetometer (SHM) built at JPL, a MicroWave Radiometer (MWR) also built at JPL, a Gravity Science experiment (GS) implemented via the telecom subsystem, two complementary particle instruments (Jovian Auroral Distribution Experiment, JADE developed by SwRI and Juno Energetic-particle Detector Instrument, JEDI from the Applied Physics Lab (APL)--JEDI and JADE both measure electrons and ions), an Ultraviolet Spectrometer (UVS) also developed at SwRI, and a radio and plasma (WAVES) experiment (from the University of Iowa). In addition, a visible camera (JunoCam) is included in the payload to facilitate education and public outreach (designed & fabricated by Malin Space Science Systems [MSSS]).
In many applications, an optical detector has to be located relative to mechanical reference points. One solution is to specify stringent requirements on (1) mounting the optical detector relative to the chip carrier, (2) soldering the chip carrier onto the printed circuit board (PCB), and (3) installing the PCB to the mechanical structure of the subsystem. Figure 1 shows a sketch of an optical detector mounted relative to mechanical reference with high positional accuracy. The optical detector is typically a fragile wafer that cannot be physically touched by any measurement tool. An optical coordinate measuring machine (CMM) can be used to position optical detectors relative to mechanical reference points. This approach will eliminate all requirements on positional tolerances. The only requirement is that the PCB is manufactured with oversized holes. An exaggerated sketch of this situation is shown in Figure 2. The sketch shows very loose tolerances on mounting the optical detector in the chip carrier, loose tolerance on soldering the chip carrier to the PCB, and finally large tolerance on where the mounting screws are located. The PCB is held with large screws and oversized holes. The PCB is mounted loosely so it can move freely around. The optical CMM measures the mechanical reference points. Based on these measurements, the required positions of the optical detector corners can be calculated. The optical CMM is commanded to go to the position where one detector corner is supposed to be. This is indicated with the cross-hairs in Figure 2(a). This figure is representative of the image of the optical CMM monitor. Using a suitable tapping tool, the PCB is manually tapped around until the corner of the optical detector is at the crosshairs of the optical CMM. The CMM is commanded to another corner, and the process is repeated a number of times until all corners of the optical detector are within a distance of 10 to 30 microns of the required position. The situation is sketched in Figure 2(b) (the figure also shows the tapping tool and where to tap). At this point the fasteners for the PCB are torqued slightly so the PCB can still move. The PCB location is adjusted again with the tapping tool. This process is repeated 3 to 4 times until the final torque is achieved. The oversized mounting holes are then filled with a liquid bonding agent to secure the board in position (not shown in the sketch). A 10- to 30-micron mounting accuracy has been achieved utilizing this method..