Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7 percent after implementing the demand control technique, 2 percent after implementing temperature modulation, and 15 percent after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8 percent, 1 percent, and 14 percent for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Control Retrofits for Multifamily Domestic Hot Water Recirculation Systems, Brooklyn, New York

Domestic hot water (DHW) heating is the second largest energy end use in U.S. buildings, exceeded only by space conditioning. Recirculation systems consisting of a pump and piping loop(s) are commonly used in multifamily buildings to reduce wait time for hot water at faucets; however, constant pumping increases energy consumption by exposing supply and return line piping to continuous heat loss, even during periods when there is no demand for hot water. In this study, ARIES installed and tested two types of recirculation controls in a pair of buildings in order to evaluate their energy savings potential. Demand control, temperature modulation controls, and the simultaneous operation of both were compared to the baseline case of constant recirculation. Additionally, interactive effects between DHW control fuel reductions and space conditioning (heating and cooling) were estimated in order to make more realistic predictions of the payback and financial viability of retrofitting DHW systems with these controls. Results showed that DHW fuel consumption reduced by 7% after implementing the demand control technique, 2% after implementing temperature modulation, and 15% after implementing demand control and temperature modulation techniques simultaneously; recirculation pump runtime was reduced to 14 minutes or less per day. With space heating and cooling interactions included, the estimated annual cost savings were 8%, 1%, and 14% for the respective control techniques. Possible complications in the installation, commissioning and operation of the controls were identified and solutions offered.

ARIES↗

Evaluating situation awareness in the control room: the development and initial testing of the process awareness and situation understanding (PASU) measure - 267

What should we ask the control room crew about when evaluating situation awareness? Currently available freeze probe techniques concentrate on trends of process parameters. Analysis of control room work shows that there are far more involved in control room crews' Situation Awareness (SA). The Process Awareness and Situation Understanding (PASU) measure has been developed from an analysis of control room work and includes probing the crew about the status of safety functions and main plant systems such as coolant supply, ordinary and emergency power supply, main reactor parameters, and main plant parameters. Results from a nuclear control room evaluation showed that the crew's overview of safety functions developed differently across scenario phases compared to the crew's overview of main process parameters. SA in the nuclear control room seems to be a multifaceted phenomenon and valid measurement needs to cover its aspects. Initial empirical testing showed that PASU was sensitive to scenario phases and related to other performance indicators. PASU, or measures based on similar principles, can be a valid and useful probe based technique for use in the evaluation of control room design and control room work. The measure will fill a gap in the research literature and will serve as an example of SA measurement with utility for control room evaluation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

Direct versus Facility Centric Load Control for Automated Demand Response

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployment of a Full-Scope Commercial Nuclear Power Plant Control Room Simulator at the Idaho National Laboratory

The INL operates the HSSL to conduct research in the design and evaluation of advanced reactor control rooms, integration of intelligent support systems to assist operators, development and assessment of advanced human performance models, and visualizations to assess advanced operational concepts across various infrastructures. This advanced facility consists of a reconfigurable simulator and a virtual reality capability (known as the Computer-Aided Virtual Environment (CAVE)) (Figure 2). It supports human factors research, including human-in-the-loop performance, HSI, and analog and digital hybrid control displays. It can be applied to the development and evaluation of control systems and displays for complex systems such as existing and advanced NPP control rooms, command and control systems, and advance emergency operations centers. The HSSL incorporates a reconfigurable control room simulator, which is currently housed in the Center for Advanced Energy Studies (CAES), a joint venture of the DOE and the Idaho University System. The simulator is a platform- and plant-neutral environment intended for full-scope and part-task testing of operator performance in various control room configurations. The simulator is not limited to a particular plant or even simulator architecture. It can support engineering simulator platforms from multiple vendors using digital interfaces. Due to its ability to be reconfigured, it is possible to switch the HSI - not just to digital panels but also to different control modalities such as those using greater plant automation or intelligent alarm filtering. The simulator currently includes three operator workstations, each capable of driving up to eight 30-inch monitors. The size and number of monitors varies depending on the particular front-end simulator deployed for a simulator study. These operator workstations would typically be used for the shift supervisor or senior reactor operator, reactor operator, and assistant reactor operator in current US NPPs. In addition to the three workstations, information can be shared between the workstations and further displayed on a large-screen overview display or a panel mimic. An 82-inch high-definition display is commonly used for the overview display.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Ecosystem-Level Biomimicry for the Built Environment: Adopting Systems Ecology Principles for the Control of Heterogeneous Energy Systems

This paper presents, to our knowledge, the first system-level engineering study to bio-mimic the cybernetics and flow dynamics of energy resources in natural ecosystems for the control of heterogeneous energy infrastructures in the built environment. To this end, we introduce a novel Biomimetic Pulsing State (BPS) control that functionally mimics mature ecosystems. A preliminary Modelica-based case study features a single-family residential building with electrical and HVAC subsystems. The BPS control objective is to minimize the energy exchange between the building and the grid for the purposes of future self-supporting buildings and grid stability. The building contains PV, a wind turbine, a battery storage system, and a fan coil/heat pump HVAC system served by an ambient district energy network. Evaluating the control performance (BPS vs. constant setpoint) over several renewable energy scenarios (net importer, net zero, net exporter), simulation results show how the building's HVAC system can dynamically adjust its electrical load and temperatures to the electrical system's net energy status in real-time with BPS control. As a net importer, the heat pump consumed 29% less energy and its peak power reduced by 15% with BPS control compared to the constant setpoint case, with the zone air temperature 1 degree C lower on average. As a net exporter, the heat pump effectively consumed the same energy, but the peak power increased by 34% with BPS control, while the zone air temperature was 1 degree C higher when renewable energy was abundant, preheating the home. BPS and constant setpoint control produced comparable results under a net zero scenario. While further evaluation is essential, BPS control may help communities meet their sustainability and resiliency targets as they transition towards fully distributed and renewable energy grids.

biomimicry↗

Controlled Nonlinear Stochastic Delay Equations: Part I: Modeling and Approximations

This two-part paper deals with 'foundational' issues that have not been previously considered in the modeling and numerical optimization of nonlinear stochastic delay systems. There are new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. There are two basic and interconnected themes for these models. The first, dealt with in this part, concerns the definition of admissible control. The classical definition of an admissible control as a nonanticipative relaxed control is inadequate for these models and needs to be extended. This is needed for the convergence proofs of numerical approximations for optimal controls as well as to have a well-defined model. It is shown that the new classes of admissible controls do not enlarge the range of the value functions, is closed (together with the associated paths) under weak convergence, and is approximatable by ordinary controls. The second theme, dealt with in Part II, concerns transportation equation representations, and their role in the development of numerical algorithms with much reduced memory and computational requirements.

97 MATHEMATICS AND COMPUTING↗

Tracking Error Learning Control for Precise Mobile Robot Path Tracking in Outdoor Environment

This article presents a Tracking-Error Learning Control (TELC) algorithm for precise mobile robot path tracking in off-road terrain. In traditional tracking error-based control approaches, feedback and feedforward controllers are designed based on the nominal model which cannot capture the uncertainties, disturbances and changing working conditions so that they cannot ensure precise path tracking performance in the outdoor environment. In TELC algorithm, the feedforward control actions are updated by using the tracking error dynamics and the plant-model mismatch problem is thus discarded. Therefore, the feedforward controller gradually eliminates the feedback controller from the control of the system once the mobile robot has been ontrack. In addition to the proof of the stability, it is proven that the cost functions do not have local minima so that the coefficients in TELC algorithm guarantee that the global minimum is reached. The experimental results show that the TELC algorithm results in better path tracking performance than the traditional tracking error-based control method. The mobile robot controlled by TELC algorithm can track a target path precisely with less than 10 cm error in off-road terrain.

42 ENGINEERING↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-based ethylene and carbon monoxide estimation, real-time optimization, and multivariable feedback control of an experimental electrochemical reactor

Electrochemical reduction of CO 2 gas is a novel CO 2 utilization technique that has the potential to mitigate the global climate crisis caused by anthropogenic CO 2 emissions, and enable the large-scale storage of energy generated from renewable sources in the form of carbon-based chemicals and fuels. However, due to the complexity of the electrochemical reactions, the explicit first-principles models for CO2 reduction are not available yet, and there has been a limited effort to develop process modeling, optimization and control of CO 2 electrochemical reactors. To this end, a rotating cylinder electrode (RCE) reactor has been constructed at UCLA to understand the mass transfer and reaction kinetics effects separately on the productivity. In the RCE reactor, the applied potential strongly influences the reaction energetics and the electrode rotation speed affects the hydrodynamic boundary layer and modifies the film mass transfer coefficient, which involves convective and diffusive transport. Further, the present work aims to develop a multi-input multi-output (MIMO) control scheme for the RCE reactor that integrates techniques from artificial and recurrent neural network modeling, nonlinear optimization, and process controller design. Specifically, production rates of two products from the experimental reactor, ethylene and carbon monoxide, are controlled by manipulating two inputs, applied potential and catalyst rotation speed. Process dynamics and controllability are analyzed, a feedback control strategy is designed and the controllers are tuned accordingly. The experimental electrochemical cell is employed to gather data for process modeling and implement the multivariable control system. Finally, the experimental results are presented which demonstrate excellent closed-loop performance by the control system and regulation of the outputs at three different set-points including an economically-optimal set-point.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of real-time density feedback control on MAST-U in L-mode

In this paper we report on the development and demonstration of density feedback control for MAST-U. Sinusoidal perturbations are used to measure the frequency response from a deuterium gas valve (actuator) to line-integrated core electron density measured by the interferometer (sensor). In the frequency range relevant for control design, only two system-identification experiments were needed to regress a first-order dynamic model. This control-oriented model informs the offline design of a proportional integral controller with the established loop-shaping controller design method. After offline verification of the controller implementation, control is demonstrated by experimentally tracking a staircase reference for the line-integrated electron density. This paper demonstrates the efficiency of controller design using system-identification and loop-shaping, providing reliable density control for MAST-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and distributed components. In this report, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Connected Traffic Signal Coordination Optimization Framework through Network-Wide Adaptive Linear Quadratic Regulator–Based Control Strategy

Traffic congestion in metropolitan areas causes several significant challenges, such as longer travel times, decreased productivity, increased fuel consumption and vehicle emissions, and even severe injuries during crashes. Traffic signal control is a management approach to reduce traffic congestion and allocate the appropriate right of way for safety and mobility efficiency, both in temporal and spatial domains. Here, this study proposes a network-wide adaptive signal control coordination optimization framework based on the linear quadratic regulator algorithm. The traffic flow conditions driven by signal control inputs are formulated based on their network-wide state-space representation. After modeling traffic control regulation constraints, an adaptive linear quadratic regulator algorithm is designed to maximize the network-wide total throughput under the current conditions. Optimal signal control split time durations for multiple intersections in the network are derived by solving the algebraic Riccati equation. Furthermore, the recursive least square parameter estimation method is employed to quantify dynamic traffic condition changes. To verify the effectiveness of this proposed signal control framework, both simulation and real-world experimental tests are conducted for multiple intersections in downtown Chattanooga, Tennessee, United States. In preparation for real-world experimental tests, pipelines for real-time data processing implementation and historical traffic flow data analysis are conducted. The test results demonstrate that the proposed control framework achieves a decrease in travel time by up to 19.4%, total time spent (TTS) by up to 11.9%, and relative queue balance (RQB) by up to 15.6%. The research findings indicate that the proposed signal control framework can be generalized to handle large scale signal control optimization network-wide.

97 MATHEMATICS AND COMPUTING↗

SDRE control strategy applied to a nonlinear robotic including drive motor

A robotic control design considering all the inherent nonlinearities of the robot-engine configuration is developed. The interactions between the robot and joint motor drive mechanism are considered. The proposed control combines two strategies, one feedforward control in order to maintain the system in the desired coordinate, and feedback control system to take the system into a desired coordinate. The feedback control is obtained using State-Dependent Riccati Equation (SDRE). For link positioning two cases are considered. Case I: For control positioning, it is only used motor voltage; Case II: For control positioning, it is used both motor voltage and torque between the links. Simulation results, including parametric uncertainties in control shows the feasibility of the proposed control for the considered system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involving the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Real-time reconstruction and control of pedestal-top electron density using RMP and gas puff at KSTAR

We report the experimental results of controlling the pedestal-top electron density by applying resonant magnetic perturbation (RMP) with in-vessel control coils and the main gas puff in the 2024-2025 KSTAR experimental campaign. The density is reconstructed using a parameterized $ψ_N$ grid and five channels of line-averaged density measured by the two-colored interferometer (TCI). The reconstruction procedure is accelerated by deploying a multi-layer perceptron to run in approximately 120 µ s and is sufficiently fast for real-time control. A proportional-integral controller was adopted, with the controller gains estimated from the system identification procedure. The experimental results demonstrate that the developed controller can follow a dynamic target while exclusively using both actuators. The absolute percentage errors between the electron density at $ψ_N$ = 0.89 and the target were approximately 1.5% median and a 2.5% average, respectively. The developed controller can even lower the density by using the pump-out mechanism under RMP, and it can follow a more dynamic range of density targets than a single actuator controller. The developed controller will enable experimental scenario exploration within a shot by dynamically setting the density target or maintaining a constant electron density within a discharge.

EFIT↗

Analysis of Power-Maximizing Region 2 Controllers for Wind and Marine Turbines

Wind and marine energy are rapidly growing and complementary technologies that share some techniques for simplified modeling and control, particularly in below-rated flow speeds. A turbine operator has several choices of controller for maximizing power in Region 2. The simple and ubiquitous KΩ 2 control law is often effective but limited in its flexibility. Alternative controllers use reference tracking to split the control objectives into a low-bandwidth optimal tip-speed ratio tracking loop to maximize steady-state power and a higher-bandwidth proportional-integral control loop to reject inflow turbulence. Several options exist for identifying the slowly varying optimal set point during operation, based on estimating the inflow velocity or filtering the power or torque signals. This study compares the trade-offs between performance and other design priorities for a few choices of reference-tracking controller in the literature for reference wind and marine turbines. Analysis is performed in the frequency domain using the linearization of each controller, and the impact of turbulent disturbances on the closed-loop system is described. The controllers are simulated in OpenFAST to analyze their performance with higher-order nonlinear turbine dynamics.

17 WIND ENERGY↗