Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configurable lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Effect of Inductive Coil Geometry on the Operating Characteristics of an Inductive Pulsed Plasma Thruster

Operational characteristics of two separate inductive thrusters with conical theta pinch coils of different cone angles are explored through thrust stand measurements and time- integrated, unfiltered photography. Trends in impulse bit measurements indicate that, in the present experimental configuration, the thruster with the inductive coil possessing a smaller cone angle produced larger values of thrust, in apparent contradiction to results of a previous thruster acceleration model. Areas of greater light intensity in photographs of thruster operation are assumed to qualitatively represent locations of increased current density. Light intensity is generally greater in images of the thruster with the smaller cone angle when compared to those of the thruster with the larger half cone angle for the same operating conditions. The intensity generally decreases in both thrusters for decreasing mass flow rate and capacitor voltage. The location of brightest light intensity shifts upstream for decreasing mass flow rate of propellant and downstream for decreasing applied voltage. Recognizing that there typically exists an optimum ratio of applied electric field to gas pressure with respect to breakdown efficiency, this result may indicate that the optimum ratio was not achieved uniformly over the coil face, leading to non-uniform and incomplete current sheet formation in violation of the model assumption of immediate formation where all the injected propellant is contained in a magnetically-impermeable current sheet.

Hallock, Ashley K.↗

Spectroscopic Determination of Trace Contaminants in High-Purity Oxygen

Oxygen used for extravehicular activities (EVAs) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen has been developed. This instrument uses a glow discharge in reduced-pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete, and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants, and may lend itself to a device capable of on-orbit verification of oxygen purity. A glow discharge is a plasma formed in a low-pressure (1 to 10 Torr) gas cell between two electrodes. Depending on the configuration, voltages ranging from 200 V and above are required to sustain the discharge. In the discharge region, the gas is ionized and a certain population is in the excited state. Light is produced by the transitions from the excited states formed in the plasma to the ground state. The spectrum consists of discrete, narrow emission lines for the atomic species, and broader peaks that may appear as a manifold for molecular species such as O2 and N2, the wavelengths and intensities of which are a characteristic of each atom. The oxygen emission is dominated by two peaks at 777 and 844 nm.

Hornung, Steven↗

Orbital Debris Assesment Tesing in the AEDC Range G

The space environment presents many hazards for satellites and spacecraft. One of the major hazards is hypervelocity impacts from uncontrolled man-made space debris. Arnold Engineering Development Complex (AEDC), The National Aeronautics and Space Administration (NASA), The United States Air Force Space and Missile Systems Center (SMC), the University of Florida, and The Aerospace Corporation configured a large ballistic range to perform a series of hypervelocity destructive impact tests in order to better understand the effects of space collisions. The test utilized AEDC's Range G light gas launcher, which is capable of firing projectiles up to 7 km/s. A non-functional full-scale representation of a modern satellite called the DebriSat was destroyed in the enclosed range enviroment. Several modifications to the range facility were made to ensure quality data was obtained from the impact events. The facility modifcations were intended to provide a high impact energy to target mass ratio (>200 J/g), a non-damaging method of debris collection, and an instrumentation suite capable of providing information on the physics of the entire imapct event.

Polk, Marshall↗

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

Development of Multi-Edge Slant Target for Unlocalized MTF Measurement of Airborne Imaging System Payloads

Calibration of imaging instruments is a critical step in effectively characterizing imaging data. A comprehensive characterization of an imaging system provides valuable insight into the overall uncertainties in the results derived from the raw data collected. The Scientifically Calibrated In-Flight Imagery (SCIFLI) team (based at NASA Langley Research Center) has designed, built, tested, and successfully flown the optical payload known as the SCIFLI Airborne Multispectral Imager (SAMI). SAMI is a multispectral imaging payload, complete with sensor configurations for the Ultraviolet-Visible spectrum as well as Near- Infrared, Shortwave Infrared, and Midwave Infrared bands and is fitted with various optical hardware designed to turn, split, and focus light beams to the respective in-band sensors. Radiometric calibrations are performed for SAMI such that the accuracy and uncertainty of thermal and spectral measurements are effectively characterized. However, SAMI does not regularly undergo spatial characterizations to evaluate the performance of the imager at high spatial frequencies. This is essential, as understanding the spatial sensor response of discrete sensors is just as important as the spectral sensor response. The payload currently utilizes a calibration cart for lab testing. Equipped with a modular setup and several radiation sources, it is perfect for performing high-quality radiometric calibrations. This work focuses on using the calibration cart to perform spatial calibrations. A custom designed calibration target is being used to evaluate the optical performance of SAMI. Specifically, the target is designed to measure the Modulation Transfer Function (MTF) of the imager in discrete locations around the focal plane. The results of this characterization will provide insight into the spatial resolution capabilities of the SAMI payload in practice. Future work includes using the results of the study to correct optical imperfections in imagery taken with SAMI.

SAMI↗

Dual-Remote Raman Technology for In-Situ Identification of Tank Waste

A new Raman spectroscopic system for in-situ identification of the composition of the solid nuclear tank waste is being developed by collaborative effort between Pacific Northwest National Laboratory (PNNL) and EIC, Inc. The recent advancements in the Raman technology allow probing the chemical composition of the tank waste without sample collection. In the newly tested configuration, the Raman probe is installed on the top of the tank riser and sends the incident laser beam to the bottom of the tank, 10 – 70 feet away. The returning light containing chemical information is collected by the Raman probe and transmits it via fiber optic cable to the spectrometer located outside the tank farm area. This dual remote technology significantly expands currently limited options for the safe rapid in-situ identification of the solid tank waste needed for the retrieval decisions. The developed Raman system was extensively tested for acceptability prior tank farm deployment. This testing included calibration of the system with the respect of the distance between the Raman probe and the sample, incident laser beam angle, and presence of the optical interferences. The Raman system was successfully deployed to C-111 tank at the US DOE Hanford site. As the result of this deployment, the composition of the hardpan at the bottom of C-111 tank was identified. Further development of the dual-remote Raman technology will provide a significant safety enhancement eliminating the potential of personnel radiation exposure associated with the grab sample collection and expands options of the rapid and cost-effective in-situ chemical analysis of the tank waste.

in-situ Hanford tank, Raman measurement↗

Dual-Remote Raman Technology for In-Situ Identification of Tank Waste - 13549

A new Raman spectroscopic system for in-situ identification of the composition of solid nuclear tank waste is being developed by collaborative effort between Pacific Northwest National Laboratory (PNNL) and EIC Laboratories, Inc. The recent advancements in Raman technology allow probing the chemical composition of the tank waste without sample collection. In the newly tested configuration, the Raman probe is installed on the top of the tank riser and sends the incident laser beam to the bottom of the tank, 10 - 70 feet away. The returning light containing chemical information is collected by the Raman probe and is transmitted via fiber optic cable to the spectrometer located outside the tank farm area. This dual remote technology significantly expands currently limited options for the safe rapid in-situ identification of the solid tank waste needed for the retrieval decisions. The developed Raman system was extensively tested for acceptability prior to tank farm deployment. This testing included calibration of the system with respect of the distance between the Raman probe and the sample, incident laser beam angle, and presence of the optical interferences. The Raman system was successfully deployed on Tank C-111 at the US DOE Hanford site. As the result of this deployment, the composition of the hardpan at the bottom of C-111 tank was identified. Further development of the dual-remote Raman technology will provide a significant safety enhancement eliminating the potential of personnel radiation exposure associated with the grab sample collection and expands options of the rapid and cost-effective in-situ chemical analysis of the tank waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polarization methods for diode laser excitation of solid state lasers

A mode-locked laser employs a coupled-polarization scheme for efficient longitudinal pumping by reshaped laser diode bars. One or more dielectric polarizers are configured to reflect a pumping wavelength having a first polarization and to reflect a lasing wavelength having a second polarization. A Yb-doped gain medium can be used that absorbs light having a first polarization and emits light having a second polarization. Using such pumping with laser cavity dispersion control, pulse durations of less than 100 fs can be achieved.

Holtom, Gary R↗

Effects of stray lights on Faraday rotation measurement for polarimeter-interferometer system on EAST

A double-pass radially view 11 chords polarimeter-interferometer system has been operated on the experimental advanced superconducting tokamak and provides important current profile information for plasma control. Stray light originating from spurious reflections along the optical path (unwanted reflections from various optical components/mounts and transmissive optical elements such as windows, waveplates, and lens as well as the detectors) and also direct feedback from the retro-reflector used to realize the double-pass configuration can both contribute to contamination of the Faraday rotation measurement accuracy. Modulation of the Faraday rotation signal due to the interference from multiple reflections is observable when the interferometer phase (plasma density) varies with time. Direct reflection from the detector itself can be suppressed by employing an optical isolator consisting of a λ/4-waveplate and polarizer positioned in front of the mixer. A Faraday angle oscillation during the density ramping up (or down) can be reduced from 5°–10° to 1°–2° by eliminating reflections from the detector. Residual modulation arising from misalignment and stray light from other sources must be minimized to achieve accurate measurements of Faraday rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-consistent Skyrme quasiparticle random-phase approximation for use in axially symmetric nuclei of arbitrary mass

We describe a new implementation of the quasiparticle random-phase approximation (QRPA) in axially symmetric deformed nuclei with Skyrme and volume-pairing energy-density functionals. After using a variety of tests to demonstrate the accuracy of the code in {sup 24,26}Mg and {sup 16}O, we report the first fully self-consistent application of the Skyrme QRPA to a heavy deformed nucleus, calculating strength distributions for several K{sup {pi}}in {sup 172}Yb. We present energy-weighted sums, properties of {gamma}-vibrational and low-energy K{sup {pi}=}0{sup +} states, and the complete isovector E1 strength function. The QRPA calculation reproduces the properties of the low-lying 2{sup +} states as well or better than it typically does in spherical nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generalizing the flash technique in the front-face configuration to measure the thermal diffusivity of semitransparent solids

In this work, we have extended the front-face flash method to retrieve simultaneously the thermal diffusivity and the optical absorption coefficient of semitransparent plates. A complete theoretical model that allows calculating the front surface temperature rise of the sample has been developed. It takes into consideration additional effects, such as multiple reflections of the heating light beam inside the sample, heat losses by convection and radiation, transparency of the sample to infrared wavelengths, and heating pulse duration. Measurements performed on calibrated solids, covering a wide range of absorption coefficients (from transparent to opaque) and thermal diffusivities, validate the proposed method.

42 ENGINEERING↗

Photoactivation Transition State and Dynamical Response of the Orange Carotenoid Protein

The orange carotenoid protein (OCP) regulates light harvesting in cyanobacteria by acting as a photoreceptor in its resting form, OCP O , and by effecting the quenching of bilin excitons upon binding to the core of the phycobilisome in its photoactivated red form, OCP R . We show herein using fluorescence anisotropy measurements and the action spectra for the rate constants of the two light-driven steps in the mechanism that the photoactivation of the OCP from Synechocystis sp. PCC 6803 is triggered by excited-state motions of the canthaxanthin chromophore that yield a twisted and bent conformation. Well-tempered metadynamics simulations reveal that a bicycle-pedal configuration, due to twisting of the two adjacent C=C bonds at the C13−C14 and C15−C15′ positions in the center of canthaxanthin’s π-conjugated isoprenoid backbone, can be accommodated by the binding site in the OCP, with the energy of a captured photon required to cross the local activation energy barriers from the dark equilibrium structure. The bicycle-pedal configuration breaks the conserved hydrogen-bonding interactions between the carbonyl substituent of the β-ionone end ring of canthaxanthin and the adjacent W288 and Y201 residues in the C-terminal domain. The action spectra are modulated by the vibronic excitation prepared by absorption transitions to the S 2 state, indicating that the photoactivation reactions are triggered by the canthaxanthin chromophore well prior to vibrational equilibration. These findings show that an ultrafast structural response of the OCP protein to the excited-state motions of the canthaxanthin chromophore controls the photoactivation yield and the sensing of blue light.

Fluorescence↗

Analysis of an anti-reflecting nanowire transparent electrode for solar cells

Transparent electrodes are an important component in many optoelectronic devices, especially solar cells. In this study, we investigate a nanowire transparent electrode that also functions as an anti-reflection coating for silicon solar cells, taking into account the practical constraints that the electrode is typically encapsulated and needs to be in electric contact with the semiconductor. Numerical simulations show that the electrode can provide near-perfect broadband anti-reflection over much of the frequency range above the silicon band gap for both polarizations while keeping the sheet resistance sufficiently low. To provide insights into the physics mechanism of this broadband anti-reflection, we introduce a generalized Fabry–Perot model, which captures the effects of the higher order diffraction channels as well as the modification of the reflection coefficient of the interface introduced by the nanowires. This model is validated using frequency-domain electromagnetic simulations. Finally, our work here provides design guidelines for nanowire transparent electrode in a device configuration that is relevant for solar cell applications.

14 SOLAR ENERGY↗

Instanton Effects in Euclidean vacuum, Real Time Production, and in the Light-front Wave Functions

Nontrivial topological structures of non-Abelian gauge fields were discovered in the 1970s. Instanton solutions, describing vacuum tunneling through topological barriers, have fermionic zero modes which are at the origin of ‘t Hooft effective Lagrangian. In the 1980s, instanton ensembles have been used to explain chiral symmetry breaking. In the 1990s, a large set of numerical simulations were performed deriving Euclidean correlation functions. The special role of scalar diquarks in nucleons and color superconductivity in dense quark matter has been elucidated. In these lectures, we discuss further developments of physics related to gauge topology. We show that the instanton–anti-instanton “streamline” configurations describe “sphaleron transitions” in high-energy collisions, which result in production of hadronic clusters with nontrivial topological/chiral charges. (They are not yet observed, but discussions of dedicated experiments at the LHC and RHIC are ongoing.) Another new direction is instanton effects in hadronic spectroscopy, both in the rest frame and on the light front. We will discuss their role in central and spin-dependent potentials, form factors and antiquark nuclear “sea”. Finally, we summarize the advances in the semiclassical theory of deconfinement, and chiral phase transitions at finite temperature, in QCD, and in some of its “deformed” versions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for dynamic control of light emission from phosphors with heat excitations

An optically emissive material and, in particular, materials for use in single photon generation technologies, have multiple excited energy states that have different decay rates and can emit photons with different properties. A primary excitation radiation source is configured to apply primary radiation to an optically emissive material to excite the optically emissive material into a primary excited state. A secondary excitation radiation source is configured to apply secondary radiation to a thermal contribution material to generate thermal energy in the thermal contribution material. The thermal contribution material is physically configured to transfer thermal energy to the optically emissive material and excite the optically emissive material from the primary excited state to a secondary excited state for dynamic control of the emission rate, or emitted photon properties, of the optically emissive material.

36 MATERIALS SCIENCE↗

Scalable, large-area optical sensing platform with compact light delivery and imaging system

An optode has a planar radiation guiding medium having a first planar surface and a second planar surface and one or more perimeter surfaces bounded by the first and second planar surfaces. An excitation energy source of the optode is configured to output into the radiation guiding medium first energy at a wavelength selected to excite a fluorophore. The optode also includes a photodetector configured to image at least a portion of the first planar surface of the radiation guiding medium by detecting second energy transmitted through the radiation guiding medium.

Zhang, Xufeng↗

Linear response of light deformed nuclei investigated by self-consistent quasiparticle random-phase approximation

We present a calculation of the properties of vibrational states in deformed, axially-symmetric even-even nuclei, within the framework of a fully self-consistent quasiparticle random phase approximation (QRPA). The same Skyrme energy density and density-dependent pairing functionals are used to calculate the mean field and the residual interaction in the particle-hole and particle-particle channels. We have tested our software in the case of spherical nuclei against fully self-consistent calculations published in the literature, finding excellent agreement. We investigate the consequences of neglecting the spin-orbit and Coulomb residual interactions in QRPA. Furthermore we discuss the improvement obtained in the QRPA result associated with the removal of spurious modes. Isoscalar and isovector responses in the deformed {sup 24-26}Mg, {sup 34}Mg isotopes are presented and compared to experimental findings.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Configurations, band structures and photocurrent responses of 4-(4-oxopyridin-1(4H)-yl)phthalic acid and its metal-organic frameworks

4-(4-oxopyridin-1(4 H)-yl)phthalic acid (H{sub 2}L) and three H{sub 2}L-based metal-organic frameworks (MOFs) formulated as ZnL(DPE)(H{sub 2}O)·H{sub 2}O (DPE=(E)-1, 2-di(pyridine −4-yl)ethene) (1), CdL(H{sub 2}O){sub 2} (2) and CdL (3) were synthesized and structurally characterized by single-crystal X-ray diffraction. The free H{sub 2}L ligand shows an enol-form and the L{sup 2−} ligand in the three MOFs exists as the keto-form. Density functional theory (DFT) calculations indicate H{sub 2}L and the three MOFs possess different band structures. Due to the existence of the N-donor, DPE in MOF 1, the conduction band (CB) minimum and band gap of MOF 1 are much lower than those of H{sub 2}L. And MOF 1 yielded much larger photocurrent density than H{sub 2}L upon visible light illumination. Electrochemical impedance spectroscopy (EIS) shows the interfacial charge transfer impedance in the presence of MOF 1 is lower than that in the presence of H{sub 2}L. The hydrous MOF 2 and the anhydrous MOF 3 are both constructed by Cd(II) and L{sup 2−}, and they can be reversibly transformed to each other. However, MOFs 2 and 3 possess different CB minimums and VB maximums, and their band gaps are much larger than that of MOF 1. - Graphical abstract: The free ligand, 4-(4-oxopyridin-1(4H)-yl)phthalic acid (H{sub 2}L) shows different configuration from its three MOFs, and they possess different band structures. MOF 1 yielded much larger visible-light-driven photocurrent density than H{sub 2}L. The hydrous MOF 2 and the anhydrous MOF 3 can be transformed to each other, and they have larger band gaps than MOF 1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗