Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Complex scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

SU-E-J-158: Experimental Investigation of Proton Radiography Based On Time-Resolved Dose Measurements

Purpose: To use proton radiography for i) in-vivo range verification of the brain fields of medulloblastoma patients in order to reduce the exit dose to the cranial skin and thus the risk of permanent alopecia; ii) for performing patient specific optimization of the calibration from CT-Hounsfield units to proton relative stopping power in order to minimize uncertainties of proton rang Methods: We developed and tested a prototype proton radiography system based on a single-plane scintillation screen coupled with a fast CCD camera (1ms sampling rate, 0.29x0.29 mm{sup 2} pixel size, 30×30 cm{sup 2} field of view). The method is based on the principle that, for passively scattered beams, the radiological depth of any point in the plateau of a spread-out Bragg-Peak (SOBP) can be inferred from the time-pattern of the dose rate measurements. We performed detector characterization measurements using complex-shape homogeneous phantoms and an Alderson phanto Results: Detector characterization tests confirmed the robustness of the technique. The results of the phantom measurements are encouraging in terms of achievable accuracy of the water equivalent thickness. A technique to minimize the degradation of spatial resolution due to multiple Coulomb scattering is discussed. Our novel radiographic technique is rapid (100 ms) and simultaneous over the whole field. The dose required to produce one radiograph, with the current settings, is ∼3 cG Conclusion: The results obtained with this simple and innovative radiography method are promising and motivate further development of technique. The system requires only a single-plane 2D dosimeter and it uses the clinical beam for a fraction of second with low dose to the patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Gas in Determining Image Quality and Resolution During In Situ Scanning Transmission Electron Microscopy Experiments

As gas-solid heterogeneous catalytic reactions are molecular in nature, a full mechanistic understanding of the process requires atomic scale characterization under realistic operating conditions. While atomic resolution imaging has become a routine in modern high-vacuum (scanning) transmission electron microscopy ((S)TEM), both image quality and resolution nominally degrade when reaction gases are introduced. In this work, we systematically assess the effects of different gases at various pressures on the quality and resolution of images obtained at room temperature in the annular dark field STEM imaging mode using a differentially pumped (DP) gas cell. This imaging mode is largely free from inelastic scattering effects induced by the presence of gases and retains good imaging properties over a wide range of gas mass/pressures. We demonstrate the application of the ESTEM with atomic resolution images of a complex oxide alkane oxidation catalyst MoVNbTeOx (M1) immersed in light and heavy gas environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Fusion for a Vision-Radiological System for Source Tracking and Discovery

A multidisciplinary approach to allow the tracking of the movement of radioactive sources by fusing data from multiple radiological and visual sensors is under development. The goal is to improve the ability to detect, locate, track and identify nuclear/radiological threats. The key concept is that such widely available visual and depth sensors can impact radiological detection, since the intensity fall-off in the count rate can be correlated to movement in three dimensions. To enable this, we pose an important question; what is the right combination of sensing modalities and vision algorithms that can best compliment a radiological sensor, for the purpose of detection and tracking of radioactive material? Similarly what is the best radiation detection methods and unfolding algorithms suited for data fusion with tracking data? Data fusion of multi-sensor data for radiation detection have seen some interesting developments lately. Significant examples include intelligent radiation sensor systems (IRSS), which are based on larger numbers of distributed similar or identical radiation sensors coupled with position data for network capable to detect and locate radiation source. Other developments are gamma-ray imaging systems based on Compton scatter in segmented detector arrays. Similar developments using coded apertures or scatter cameras for neutrons have recently occurred. The main limitation of such systems is not so much in their capability but rather in their complexity and cost which is prohibitive for large scale deployment. Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development on two separate calibration algorithms for characterizing the fused sensor system. The deviation from a simple inverse square-root fall-off of radiation intensity is explored and accounted for. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked. Infrared, laser or stereoscopic vision sensors are all options for computer-vision implementation depending on interior vs exterior deployment, resolution desired and other factors. Similarly the radiation sensors will be focused on gamma-ray or neutron detection due to the long travel length and ability to penetrate even moderate shielding. There is a significant difference between the vision sensors and radiation sensors in the way the 'source' or signals are generated. A vision sensor needs an external light-source to illuminate the object and then detects the re-emitted illumination (or lack thereof). However, for a radiation detector, the radioactive material is the source itself. The only exception to this is the field of active interrogations where radiation is beamed into a material to entice new/additional radiation emission beyond what the material would emit spontaneously. The aspect of the nuclear material being the source itself means that all other objects in the environment are 'illuminated' or irradiated by the source. Most radiation will readily penetrate regular material, scatter in new directions or be absorbed. Thus if a radiation source is located near a larger object that object will in turn scatter some radiation that was initially emitted in a direction other than the direction of the radiation detector, this can add to the count rate that is observed. The effect of these scatter is a deviation from the traditional distance dependence of the radiation signal and is a key challenge that needs a combined system calibration solution and algorithms. Thus both an algebraic approach as well as a statistical approach have been developed and independently evaluated to investigate the sensitivity to this deviation from the simplified radiation fall-off as a function of distance. The resulting calibrated system algorithms are used and demonstrated in various laboratory scenarios, and later in realistic tracking scenarios. The selection and testing of radiological and computer-vision sensors for the additional specific scenarios will be the subject of ongoing and future work. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed-Valent Dicobalt and Iron-Cobalt Complexes with High-Spin Configurations and Short Metal-Metal Bonds

Cobalt–cobalt and iron–cobalt bonds are investigated in coordination complexes with formally mixed-valent [M 2 ] 3+ cores. The trigonal dicobalt tris(diphenylformamidinate) compound, Co 2 (DPhF) 3 , which was previously reported by Cotton, Murillo, and co-workers (Inorg. Chim. Acta 1996, 249, 9), is shown to have an energetically isolated, high-spin sextet ground-state by magnetic susceptibility and electron paramagnetic resonance (EPR) spectroscopy. A new tris(amidinato)amine ligand platform is introduced. By tethering three amidinate donors to an apical amine, this platform offers two distinct metal-binding sites. Using the phenyl-substituted variant (abbreviated as L Ph ), the isolation of a dicobalt homobimetallic and an iron–cobalt heterobimetallic are demonstrated. The new [Co 2 ] 3+ and [FeCo] 3+ cores have high-spin sextet and septet ground states, respectively. Their solid-state structures reveal short metal–metal bond distances of 2.29 Å for Co–Co and 2.18 Å for Fe–Co; the latter is the shortest distance for an iron–cobalt bond to date. To assign the positions of iron and cobalt atoms as well as to determine if Fe/Co mixing is occurring, X-ray anomalous scattering experiments were performed, spanning the Fe and Co absorption energies. These studies show only a minor amount of metal-site mixing in this complex, and that FeCoL Ph is more precisely described as (Fe 0.94(1) Co 0.06(1) )(Co 0.95(1) Fe 0.05(1) )L Ph . The iron–cobalt heterobimetallic has been further characterized by Mössbauer spectroscopy. Its isomer shift of 0.65 mm/s and quadrupole splitting of 0.64 mm/s are comparable to the related diiron complex, Fe 2 (DPhF) 3 . On the basis of spectroscopic data and theoretical calculations, it is proposed that the formal [M 2 ] 3+ cores are fully delocalized.

Zall, Christopher M.↗

Light Higgs boson, light dark matter, and gamma rays

A light Higgs boson is preferred by M{sub W} and m{sub t} measurements. A complex scalar singlet addition to the standard model allows a better fit to these measurements through a new light singlet dominated state. It then predicts a light dark matter (DM) particle that can explain the signals of DM scattering from nuclei in the CoGeNT and DAMA/LIBRA experiments. Annihilations of this DM in the galactic halo, AA{yields}bb, cc, {tau}{sup +}{tau}{sup -}, lead to gamma rays that naturally improve a fit to the Fermi Large Area Telescope data in the central galactic regions. The associated light neutral Higgs boson may also be discovered at the Large Hadron Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the irising effect of a slow-gating intensified charge-coupled device on laser-induced incandescence measurements of soot

Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

36 MATERIALS SCIENCE↗

Evaluation of the irising effect of a slow-gating ICCD on laser-induced incandescence measurements of soot.

Intensified charge-coupled devices (ICCDs) are used extensively in many scientific and engineering environments to image weak or temporally short optical events. To optimize the quantum efficiency of light collection, many of these devices are chosen to have characteristic intensifier gate times that are relatively slow, on the order of tens of nanoseconds. For many measurements associated with nanosecond laser sources, such as scattering-based diagnostics and most laser-induced fluorescence applications, the signals rise and decay sufficiently fast during and after the laser pulse that the intensifier gate may be set to close after the cessation of the signal and still effectively reject interferences associated with longer time scales. However, the relatively long time scale and complex temporal response of laser-induced incandescence (LII) of nanometer-sized particles (such as soot) offer a difficult challenge to the use of slow-gating ICCDs for quantitative measurements. In this paper, ultraviolet Rayleigh scattering imaging is used to quantify the irising effect of a slow-gating scientific ICCD camera, and an analysis is conducted of LII image data collected with this camera as a function of intensifier gate width. The results demonstrate that relatively prompt LII detection, generally desirable to minimize the influences of particle size and local gas pressure and temperature on measurements of the soot volume fraction, is strongly influenced by the irising effect of slow-gating ICCDs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiple Lattice Instabilities and Complex Ground State in Cs 2 Ag Bi Br 6

Metal-halide perovskites (MHPs) are attracting considerable interest for optoelectronic applications, with Cs 2 Ag Bi Br 6 one of the main contenders among lead-free systems. Cs 2 Ag Bi Br 6 crystallizes in a nominally double-perovskite structure, but exhibits a soft lattice with large atomic fluctuations characteristic of MHPs. While crucial to understand electron-phonon and phonon-phonon couplings, the spatiotemporal correlations of these fluctuations remain largely unknown. Here, we reveal these correlations using comprehensive neutron and x-ray scattering measurements on Cs 2 Ag Bi Br 6 single crystals, complemented with first-principles simulations augmented with machine-learned neural-network potentials. We report the discovery of an unexpected complex modulated ground-state structure containing several hundred atoms, arising from a soft-phonon instability of the low-temperature tetragonal phase. Further, our experiments and simulations both reveal extensive correlated two-dimensional fluctuations of Br octahedra at finite temperature, arising from soft optic phonons that are strongly broadened by anhamonicity, reflecting very shallow potential wells. These results provide new insights into the atomic structure and fluctuations in MHPs, critical to understand and control their thermal and optoelectronic properties. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE UV/BLUE EFFECTS OF SPACE WEATHERING MANIFESTED IN S-COMPLEX ASTEROIDS. I. QUANTIFYING CHANGE WITH ASTEROID AGE

Evidence for the manifestation of space weathering in S-complex asteroids as a bluing of the UV/blue reflectance spectrum is extended using high resolution CCD reflectance spectra of 21 main-belt, 1 Mars-crossing, and 3 near-Earth asteroids covering a wavelength range of 320–620 nm. Demonstration of the transition of iron-bearing materials from volume scattering to surface (Fresnel) scattering is apparent as an abrupt downturn at wavelengths just short of 400 nm in reflectance spectra of fresh asteroid surfaces. The weathering away of this downturn is demonstrated by its absence in reflectance spectra of mature S-complex asteroids, consistent with an increase in npFe{sup 0} on the material's surface. Modeling of the effects of the addition of small amounts of npFe{sup 0} to particles from both a hypothetical mineral and a terrestrial basalt shows that evidence of the addition of 0.0001% npFe{sup 0} affects the reflectance at UV/blue wavelengths, while the addition of 0.01% is required to see the visible/near-infrared reddening and diminution of absorption features. Thus, the UV/blue reflectance characteristics allow earlier detection of the onset of space weathering effects. Combining UV/blue spectral characteristics of asteroids and ordinary chondrite meteorites with estimated ages of the young Datura family, we establish a method of dating asteroid surface ages during the early stages of space weathering. We demonstrate by dating the surface of NEA 163249 2002 GT to be 109 (±18) to 128 (±10) Kyr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deriving Stable Peak Models to Fit Complex XPS Data From Cu Contaminated Pt Electrocatalysts

X-ray Photoelectron Spectroscopy spectra peak models, designed to partition photoemission signals emanating from different elements or chemical states within an atom, are fitted to data limited to an energy interval over which inelastically scattered photoemission signal can be estimated. While the choice of background approximation and line shapes of components to the peak model requires careful consideration, the energy interval used to define the data to which the peak model is optimized has a significant impact on the final peak model. The relationship between the background intensity and data intensity at the start and end of the energy interval dictates the line shapes used in the peak model. In this work, we devise a method to peak fit a complex overlapping Cu 3p and Pt 4f XPS peak structure to perform the elemental quantification. We first use an Al 2s peak to illustrate how background curves approach data at the limits of the energy interval over which the background is defined, influencing the analysis of XPS spectra. Next, we demonstrate the nature of interactions between specific line shapes (Voigt and pseudo-Voigt profiles) suitable for photoemission peaks and a specific background curve (Shirley) and a peak model is presented that includes components to the peak model that accommodates background intensity during fitting of the peak model to data. The peak model allowed for quantification of the contributions of Pt 4f peaks emanating from the substrate that exhibits strong asymmetry in the presence of the inhomogeneously distributed Cu species, mostly of Lorentzian character.

XPS↗

Opportunities for Materials Science and Biological Research at the OPAL Research Reactor

Neutron scattering techniques have evolved over more than 1/2 century into a powerful set of tools for determination of atomic and molecular structures. Modern facilities offer the possibility to determine complex structures over length scales from {approx}0.1 nm to {approx}500 nm. They can also provide information on atomic and molecular dynamics, on magnetic interactions and on the location and behaviour of hydrogen in a variety of materials. The OPAL Research Reactor is a 20 megawatt pool type reactor using low enriched uranium fuel, and cooled by water. OPAL is a multipurpose neutron factory with modern facilities for neutron beam research, radioisotope production and irradiation services. The neutron beam facility has been designed to compete with the best beam facilities in the world. After six years in construction, the reactor and neutron beam facilities are now being commissioned, and we will commence scientific experiments later this year. The presentation will include an outline of the strengths of neutron scattering and a description of the OPAL research reactor, with particular emphasis on it's scientific infrastructure. It will also provide an overview of the opportunities for research in materials science and biology that will be possible at OPAL, and mechanisms for accessing the facilities. The discussion will emphasize how researchers from around the world can utilize these exciting new facilities.

36 MATERIALS SCIENCE↗

Neutrino Scattering in the NOvA Near Detector

aNOvA is a long-baseline accelerator-based neutrino experiment based in the USA. NOvA uses an intense neutrino beam produced at Fermilab’s accelerator complex to make physics measurements of neutrino oscillations, neutrino cross sections, and much more. For its physics goals, NOvA uses two functionally-identical detectors. The Near Detector (ND) is situated at Fermilab, 1 km from the neutrino target and the Far Detector (FD) is located at Ash River, MN, a distance of 810 km from the neutrino source. The ND receives a high statistics neutrino flux which gives a unique opportunity for high-precision neutrino cross-section measurements and is used as a control for the oscillation analyses. In this talk/poster, I will give an overview of the NOvA experiment. I will also talk about the current and future status of the NOvA’s cross-section physics program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the dynamics of structural changes in biological macromolecules from light scattering data

Examining techniques to study the dynamics of structural changes in various molecules has been an ongoing goal of the space program. Knowing how these phenomena occur in biological systems is fundamental to understanding what is necessary for life to remain functional in the space environment. A hierarchy of biological organization is functionally described when cells join together small organic molecules to form larger and more complex molecules. Characterizing the architecture of a particular macromolecule helps determine how that molecule works in the living cell and is basic to the diversity of life. Understanding this arrangement involves the correlation of the structure of macromolecules with their functions. A light scattering photometer was developed for detecting continuous measurement of the angular spectrum of light scattered by dynamically changing systems. The analysis of light scattered by biological macromolecules can be used to determine concentration, size, shape, molecular weight, and structural changes of cells, such as erythrocytes. Some light scattering photometers can collect and store 120 angular scattering spectra per minute, with an angular resolution of 0.2 deg which can be displayed with computer graphics. The light scattering photometer does the following: functions to produce and detect scattered light; determines scatter angles; and collects, stores, and analyzes data.

Johnson, Adriel D.↗

Dusty plasma experiment to confirm an expression for the decay of autocorrelation functions

Statistical physicists recently proposed an expression for an autocorrelation function (ACF) [Belousov and Cohen, Phys. Rev. E 94, 062124 (2016)] that has, until now, not been tested experimentally. The expression captures the early behavior of the ACF decay, when the ACF is flattened. Using experimental data from a nonequilibrium steady-state dusty plasma, we confirm that the expression's use extends to liquidlike strongly coupled plasmas. Here, a transition in the shape of the ACF is identified, and we suggest that it corresponds to the onset of collisional scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel inert crystal delivery medium for serial femtosecond crystallography

Serial femtosecond crystallography (SFX) has opened a new era in crystallography by permitting nearly damage-free, room-temperature structure determination of challenging proteins such as membrane proteins. In SFX, femtosecond X-ray free-electron laser pulses produce diffraction snapshots from nanocrystals and microcrystals delivered in a liquid jet, which leads to high protein consumption. A slow-moving stream of agarose has been developed as a new crystal delivery medium for SFX. It has low background scattering, is compatible with both soluble and membrane proteins, and can deliver the protein crystals at a wide range of temperatures down to 4°C. Using this crystal-laden agarose stream, the structure of a multi-subunit complex, phycocyanin, was solved to 2.5Å resolution using 300µg of microcrystals embedded into the agarose medium post-crystallization. The agarose delivery method reduces protein consumption by at least 100-fold and has the potential to be used for a diverse population of proteins, including membrane protein complexes.

Conrad, Chelsie E.↗

Real-space observation of the dissociation of a transition metal complex and its concurrent energy redistribution

Mechanistic insights into photodissociation dynamics of transition metal carbonyls, like Fe(CO) 5 , are fundamental for understanding active catalytic intermediates. Although extensively studied, the structural dynamics of these systems remain elusive. Using ultrafast X-ray scattering, we uncover the photochemistry of Fe(CO) 5 in real space and time, observing synchronous oscillations in atomic pair distances, followed by a prompt rotating CO release preferentially in the axial direction. This behavior aligns with simulations, reflecting the interplay between the axial Fe-C distances’ potential energy landscape and non-adiabatic transitions between metal-to-ligand charge-transfer states. Additionally, we characterize a secondary delayed CO release associated with a reduction of Fe-C steady state distances and structural dynamics of the formed Fe(CO) 4 . Our results quantify energy redistribution across vibration, rotation, and translation degrees of freedom, offering a microscopic view of complex structural dynamics, enhancing our grasp on Fe(CO) 5 photodissociation, and advancing our understanding of transition metal catalytic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Ionic Strength, Salt, and pH on Aggregation of Boehmite Nanocrystals: Tumbler Small-Angle Neutron and X-ray Scattering and Imaging Analysis

The U.S. government currently spends significant resources annually managing the legacies of the Cold War, including 300 million liters of highly radioactive wastes stored in hundreds of tanks at the Hanford Site (WA) and the Savannah River Site (SC). The materials in these tanks consist of highly radioactive slurries and sludges at very high pH and salt concentrations. The solid particles primarily consist of aluminum hydroxides and oxyhydroxides (gibbsite and boehmite), although many other materials are present. These form complex aggregates that dramatically affect the rheology of the solutions and, therefore, efforts to recover and treat these wastes. In this paper we have used a combination of transmission and cryo-transmission electron microscopy, dynamic light scattering, and X-ray and neutron small- and ultra-small angle scattering to study the aggregation in controlled environments of synthetic nano-boehmite particles at pH 9 (approximately the point of zero charge) and 12, and sodium-nitrate and calcium-nitrate concentrations up to 1 molal. While the initial particles form individual rhombohedral platelets, once placed in solution they quickly form well-bonded stacks, primary aggregates, up to ~ 150 nm long. These are more prevalent at pH=12. Addition of calcium-nitrate or sodium-nitrate has a similar effect as lowering pH, but approximately one hundred times less calcium than sodium is needed to observe this effect. These aggregates have fractal dimension between 2.5 and 2.6 that are relatively unaffected by salt concentration for calcium-nitrate at high pH. Larger aggregates (> ~ 400 nm) are also formed, but their size distributions are discrete rather than continuous. The fractal dimensions of these aggregates are strongly pH dependent but only become dependent on solute at high salt concentrations.

36 MATERIALS SCIENCE↗