Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

Calibration and operation of a large space-based optical interferometer

The on-orbit calibration of the optics, structure, and control systems of the CSI Focus Mission Interferometer (FMI) is described. The calibration involves the estimation and propagation of both positional and rotational parameters and the propagation of both positional and rotational parameters at the nanometer/nanoradian level. It is shown that, given a nanometer class metrology system to monitor positional changes of critical optical elements, this calibration procedure should enable the FMI to perform 50 picoradian astrometry. The same Kalman filter that implements the initializing calibration of the interferometer baselines and internal pathlengths will also participate in the astrometric measurements of stellar positions.

Laskin, R. A.↗

Earth Radiation Budget Experiment scanner radiometric calibration results

The Earth Radiation Budget Experiment (ERBE) scanning radiometers are producing measurements of the incoming solar, earth/atmosphere-reflected solar, and earth/atmosphere-emitted radiation fields with measurement precisions and absolute accuracies, approaching 1 percent. ERBE uses thermistor bolometers as the detection elements in the narrow-field-of-view scanning radiometers. The scanning radiometers can sense radiation in the shortwave, longwave, and total broadband spectral regions of 0.2 to 5.0, 5.0 to 50.0, and 0.2 to 50.0 micrometers, respectively. Detailed models of the radiometers' response functions were developed in order to design the most suitable calibration techniques. These models guided the design of in-flight calibration procedures as well as the development and characterization of a vacuum-calibration chamber and the blackbody source which provided the absolute basis upon which the total and longwave radiometers were characterized. The flight calibration instrumentation for the narror-field-of-view scanning radiometers is presented and evaluated.

Lee, Robert B., III↗

In-flight validation and calibration of the spectral and radiometric characteristics of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

Through an in-flight calibration experiment at Rogers Dry Lake, California on September 20, 1989, the radiometric and spectral properties of AVIRIS were determined. In-flight spectral channel positions and the spectral response function in 10 regions of the AVIRIS spectral range, taking in all four spectrometers, are shown to agree closely with the corresponding parameters measured in the laboratory. The intraflight stability for the Rogers Dry Lake calibration site is better than 2 percent with the exception of the strong atmospheric water absorptions where the measured radiance is close to zero. This experiment has provided both direct generation of an in-flight spectral and radiometric calibration and validation of the laboratory calibration at the reported level accuracy.

Green, Robert O.↗

Accuracy of the spectral and radiometric laboratory calibration of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The laboratory procedures, algorithms, measurements, and uncertainties associated with generation of the spectral and radiometric calibration of data acquired by AVIRIS are described. AVIRIS is an airborne sensor that obtains high-spatial-resolution image data of the earth in 224 spectral channels in four spectrometers covering the range from 400 to 2450 nm. The spectral calibration of AVIRIS agrees with the in-flight data to within two nanometers, and the absolute radiometric calibration is consistent with the in-flight verification to 10 percent over the spectral range. In-flight radiometric stability as measured by five consecutive passes over the surface calibration site is reported to be between three and five percent.

Chrien, Thomas G.↗

Another Technique For Calibration Of Polarimetric Radar

Inexpensive technique involves four-stage procedure where different aspects of radar system calibrated at each stage. Provides calibration of relative phase, crosstalk, relative amplitude, and absolute amplitude. Only artificial target(s) required is at least one trihedral corner reflector. Advantage of four-step calibration procedure is that one does not have to perform entire procedure if one does not need full calibration.

Van Zyl, Jakob J.↗

Results of the 1989 SAR calibration experiment at Oberpfaffenhofen

Results from the 1989 Airborne Synthetic Aperture Radar (SAR) Calibration Campaign at the DLR test site in Oberpfaffenhofen are presented. Passive corner reflectors were used to derive the receiver and transmitter distortion matrices and the absolute calibration factor of the multispectral polarimetric DC-8 SAR from the complex high resolution data. A basic requirement for cross-calibration of data from different tracks is the stability of the SAR system. The polarimetric properties of the uncalibrated data were used to describe this stability. Quality criteria for a successful polarimetric calibration were provided by the channel balance and cross-talk parameters.

Zink, M.↗

External calibration of polarimetric radars using point and distributed targets

Polarimetric calibration algorithms using combinations of point targets and reciprocal distributed targets are developed. From the reciprocity relations of distributed targets, and equivalent point target response is derived. Then the problem of polarimetric calibration using two point targets and one distributed target reduces to that using three point targets, which has been previously solved. For calibration using one point target and one reciprocal distributed target, two cases are analyzed with the point target being a trihedral reflector or a polarimetric active radar calibrator (PARC). For both cases, the general solutions of the system distortion matrices are written as a product of a particular solution and a matrix with one free parameter. For the trihedral-reflector case, this free parameter is determined by assuming azimuthal symmetry for the distributed target. For the PARC case, knowledge of one ratio of two covariance matrix elements of the distributed target is required to solve for the free parameter. Numerical results are simulated to demonstrate the usefulness of the developed algorithms.

Yueh, S. H.↗

Instrumentation and calibration issues for Space Station Freedom and future space projects

Space-based instrumentation calibration for long duration and remote space missions is discussed. The traditional approach, in which instrumentation was an afterthought in the space program design process and calibration was not even addressed until after design was completed, are discussed. Current issues and approaches to calibration are discussed, and guidelines are developed to instrumentation calibration for the Space Station Freedom and beyond.

Bushman, David M.↗

Ground-reference site and on-board methods for sensor absolute calibration in the 0.4 to 2.5 micron range

The absolute radiometric calibration uncertainty requirement for several multispectral imaging sensors to be used in the Earth Observing System (EOS) program is +/- 2 percent (one sigma) with respect to the sun. Proposed in-flight absolute calibration methods are reviewed that have this uncertainty as their goal. In particular two methods are described as are recent improvements to them that concern reflectance- and radiance-based calibration using a carefully selected ground reference site. The magnitudes of the error sources are listed. A ratioing radiometer approach to monitoring the reflectance of a solar diffuser used for onboard calibration is discussed.

Slater, P. N.↗

Development of a calibration workstation for SIR-C

The paper describes the status of a comprehensive synthetic aperture radar (SAR) software package developed specifically to aid the calibration of a multifrequency and multipolarization radar like the Shuttle Imaging Radar, SIR-C. The primary data types processed are engineering telemetry, point targets (corner reflectors and polarimetric active radar calibrators), distributed targets (clutter), tone-generators, and ground receivers. The parameters derived to aid the calibration of the production processor include measurements of relative radiometric channel to channel imbalance, absolute calibration constants, antenna pattern corrections, noise levels, polarimetric cross-talk, and geometric offsets. The software reports standard performance measurements such as resolution, peak and integrated sidelobes, radiometric response accuracy, and geometrical distortions such as scale errors, position bias and standard deviation, and image skew. Furthermore, the inclusion of software to allow updates of the shuttle-state vector (position and velocity) is considered.

Madsen, S. N.↗

Photometer calibration error using extended standard sources

As part of a project to compare measurements of the night airglow made by the visible airglow experiment on the Atmospheric Explorer-C satellite, the standard light sources of several airglow observatories were compared with the standard source used in the absolute calibration of the satellite photometer. In the course of the comparison, it has been found that serious calibration errors (up to a factor of two) can arise when a calibration source with a reflecting surface is placed close to an interference filter. For reliable absolute calibration, the source should be located at a distance of at least five filter radii from the interference filter.

Torr, M. R.↗

SSME Automated Engine Calibration System (AECS)

An algorithm is derived for the real-time calibration of the engine fuel flowmeter and the engine mixture ratio during Space Shuttle Main Engine (SSME) ground testing. Because currently used calibration methods are post-test operations, there exists no fail-safe way of predicting at what mixture ratio a planned test will run. It is proposed that the algorithm developed here be used as part of an Automated Engine Calibration System (AECS) which could ensure that nearly all SSME tests are run at the proper mixture ratio. In this way, AECS has the potential of increasing the efficiency of the SSME ground test program. In addition to the derivation of the algorithm, an overview of this calibration system is presented along with the list of test stand facility instrumentation necessary for AECS implementation.

Greene, William D.↗

Laboratory calibration and characterization of video cameras

Some techniques for laboratory calibration and characterization of video cameras used with frame grabber boards are presented. A laser-illuminated displaced reticle technique (with camera lens removed) is used to determine the camera/grabber effective horizontal and vertical pixel spacing as well as the angle of nonperpendicularity of the axes. The principal point of autocollimation and point of symmetry are found by illuminating the camera with an unexpanded laser beam, either aligned with the sensor or lens. Lens distortion and the principal distance are determined from images of a calibration plate suitably aligned with the camera. Calibration and characterization results for several video cameras are presented. Differences between these laboratory techniques and test range and plumb line calibration are noted.

Burner, A. W.↗

Comparison Of Two Methods Of Calibrating Polarimetric SAR

Report presents comparative analysis of two approaches to calibration of synthetic-aperture radar (SAR). Performed in context of NASA/JPL SAR system mounted in DC-8 airplane, also applicable to any polarimetric SAR system of similar design. Demonstrates functional equivalence of two approaches to calibration. In one, known as Klein's approach, SAR data calibrated supplied in scattering-matrix format. Other named after van Zyl, data calibrated supplied in Stokes-matrix (compressed) format.

Freeman, Anthony↗

Neural networks for calibration tomography

Artificial neural networks are suitable for performing pattern-to-pattern calibrations. These calibrations are potentially useful for facilities operations in aeronautics, the control of optical alignment, and the like. Computed tomography is compared with neural net calibration tomography for estimating density from its x-ray transform. X-ray transforms are measured, for example, in diffuse-illumination, holographic interferometry of fluids. Computed tomography and neural net calibration tomography are shown to have comparable performance for a 10 degree viewing cone and 29 interferograms within that cone. The system of tomography discussed is proposed as a relevant test of neural networks and other parallel processors intended for using flow visualization data.

Decker, Arthur↗

Solar-diffuser panel and ratioing radiometer approach to satellite sensor on-board calibration

The use of a solar-diffuser panel is a desirable approach to the on-board absolute radiometric calibration of satellite multispectral sensors used for earth observation in the solar reflective spectral range. It provides a full aperture, full field, end-to-end calibration near the top of the sensor's dynamic range and across its entire spectral response range. A serious drawback is that the panel's reflectance, and the response of any simple detector used to monitor its reflectance may change with time. This paper briefly reviews some preflight and on-board methods for absolute calibration and introduces the ratioing-radiometer concept in which the radiance of the panel is ratioed with respect to the solar irradiance at the time the multispectral sensor is viewing the panel in its calibration mode.

Slater, Philip N.↗

UV/VUV radiometric calibrations at SURF II

Since 1981 more than 150 instrument calibrations have been performed on the radiometric instrumentation calibration beamline at the Synchrotron Ultraviolet Radiation Facility (SURF II) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland. This 300 MeV electron storage ring operates routinely at electron currents greater than 250 mA. The spectrometer calibration beamline provides a continuum of radiation from 4 nm through the visual spectral region in the form of an intense beam with total angular divergence of 1.2 mrad. The probable uncertainty for the flux ranges from about 5 percent at 4 nm to less than 2 percent above 20 nm. The new system will radiometrically trace to SURF II, and thus is expected to reduce the calibration uncertainty for diodes in this region by a factor of five to the 1-2 percent level.

Furst, Mitchell L.↗