Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical Research”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction

Purpose: Combined MR/PET is a relatively new, hybrid imaging modality. A human MR/PET prototype system consisting of a Siemens 3T Trio MR and brain PET insert was installed and tested at our institution. Its present design does not offer measured attenuation correction (AC) using traditional transmission imaging. This study is the development of quantification tools including MR-based AC for quantification in combined MR/PET for brain imaging. Methods: The developed quantification tools include image registration, segmentation, classification, and MR-based AC. These components were integrated into a single scheme for processing MR/PET data. The segmentation method is multiscale and based on the Radon transform of brain MR images. It was developed to segment the skull on T1-weighted MR images. A modified fuzzy C-means classification scheme was developed to classify brain tissue into gray matter, white matter, and cerebrospinal fluid. Classified tissue is assigned an attenuation coefficient so that AC factors can be generated. PET emission data are then reconstructed using a three-dimensional ordered sets expectation maximization method with the MR-based AC map. Ten subjects had separate MR and PET scans. The PET with [{sup 11}C]PIB was acquired using a high-resolution research tomography (HRRT) PET. MR-based AC was compared with transmission (TX)-based AC on the HRRT. Seventeen volumes of interest were drawn manually on each subject image to compare the PET activities between the MR-based and TX-based AC methods. Results: For skull segmentation, the overlap ratio between our segmented results and the ground truth is 85.2 ± 2.6%. Attenuation correction results from the ten subjects show that the difference between the MR and TX-based methods was <6.5%. Conclusions: MR-based AC compared favorably with conventional transmission-based AC. Quantitative tools including registration, segmentation, classification, and MR-based AC have been developed for use in combined MR/PET.

60 APPLIED LIFE SCIENCES↗

The first experience of using {sup 99m}Tc-Al{sub 2}O{sub 3}-based radiopharmaceutical for the detection of sentinel lymph nodes in cervical cancer patients

The purpose of the study was to evaluate the feasibility of using {sup 99m}Tc-Al{sub 2}O{sub 3}-based radiopharmaceutical, a novel molecular imaging agent for sentinel lymph node detection in patients with invasive cervical cancer. The study included 23 cervical cancer patients (T1aNxMx-T2bNxMx) treated at the Tomsk Cancer Research Institute. In the 18 hours before surgery, 80 MBq of the {sup 99m}Tc-Al{sub 2}O{sub 3} in peritumoral injected, followed by single-photon emission computed tomography (SPECT) of the pelvis and intraoperative SLN identification. Twenty-seven SLNs were detected by SPECT, and 34 SLNs were identified by intraoperative gamma probe. The total number of identified SLNs per patient ranged from 1 to 3 (the mean number of SLNs was 1.4 per patient). The most common site for SLN detection was the external iliac region (57.2%), followed by the internal iliac (14%), obturator (14%), presacral and retrosacral regions (14%), and the parametrial region (1%). Sensitivity in detecting SLNs was 100% for intraoperative SLN identification and 79% for SPECT image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Concept for LSS Based on Advanced Microalgal Biotechnologies

One of the key issues for successful human space exploration is biomedical life support in hostile space and planetary environments that otherwise cannot sustain life. Bioregenerative life support systems (LSS) are one of the options for atmospheric regeneration. To date, no bioregenerative LSS has shown capability for 100% air regeneration. Nor have these LSS been robust enough to simultaneously provide a regenerable complete food source. In contrast to microalgae, traditional plant approaches, e.g. wheat and lettuce, are lacking essential amino acids, vitamins, and micronutrients. Moreover, the rate of photosynthesis by microalgae significantly exceeds that of high plants. Nevertheless, the employment of microalgae in LSS technology was restricted, until recently, due to high water demands. Also the per person requirement of a 40L volume of microalgae in a photobioreactor, to provide daily O2 production, made an algae-based approach less attractive. By employing a vertically stacked membrane bioreactor, coupled with a solar tracker and photon-delivery system, a lightweight air revitalization system for space based applications, with minimal water requirements, can be developed. Our preliminary estimations suggest that a membrane bioreactor, 8m3 in volume, comprised of 80m2 (twenty 2m x 2m membranes, each spaced 10 cm apart), and a total of 70L of water could produce 2.7 kg of dried microalgal biomass that would supply the energy and essential amino acid requirements, as well as producing sufficient O2 for the daily needs of a 15 member crew. Research on the biochemical content of edible blue-green alga Spirulina (Arthrospira) platensis shows a wide spectrum of stable Spirulina mutants with an enhanced content of amino acids, -carotene, and phycobilliprotein c-phycocyanin. Feeding animals suffering from radiation-induced lesions, c-phycocyanin, extracted from strain 27G, led to a correction in the decrement of dehydrogenase activity and energy-rich phosphate levels, as well as improved antioxidant defense and pyruvate levels, compared to untreated animals. Experimental anemia in rats was corrected by feeding Spirulina platensis strains 198B and 27G, (with an enhanced content of methionine, phycobiliproteins and carotenoids). Spirulina was recently shown by Ananyev et al, 2005, to be an oxygenic organism with the highest level of photosystem II activity (O2 production). We propose therefore to develop a design for membrane-based photoreactors for Lunar and Mars exploration habitat LSS, for the cultivation of genetically modified strains of Spirulina to scrub CO2 and supply astronauts with O2, protein, vitamins, and immunostimulators.

Brown, I.↗

SU-E-J-136: Investigation Into Robustness of Stopping Power Calculated by DECT and SECT for Proton Therapy Treatment Planning

Purpose: To investigate the robustness of dual energy CT (DECT) and single energy CT (SECT) proton stopping power calibration techniques and quantify the associated errors when imaging a phantom differing in chemical composition to that used during stopping power calibration. Methods: The CIRS tissue substitute phantom was scanned in a CT-simulator at 90kV and 140kV. This image set was used to generate a DECT proton SPR calibration based on a relationship between effective atomic number and mean excitation energy. A SECT proton SPR calibration based only on Hounsfield units (HUs) was also generated. DECT and SECT scans of a second phantom of known density and chemical composition were performed. The SPR of the second phantom was calculated with the DECT approach (SPR-DECT),the SECT approach (SPR-SECT) and finally the known density and chemical composition of the phantom (SPR-ref). The DECT and SECT image sets were imported into the Pinnacle{sup 3} research release of proton therapy treatment planning. The difference in dose when exposed to a common pencil beam distribution was investigated. Results: SPR-DECT was found to be in better agreement with SPR-ref than SPR- SECT. The mean difference in SPR for all materials was 0.51% for DECT and 6.89% for SECT. With the exception of Teflon, SPR-DECT was found to agree with SPR-ref to within 1%. Significant differences in calculated dose were found when using the DECT image set or the SECT image set. Conclusion: The DECT calibration technique was found to be more robust to situations in which the physical properties of the test materials differed from the materials used during SPR calibration. Furthermore, it was demonstrated that the DECT and SECT SPR calibration techniques can Result in significantly different calculated dose distributions.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

Tuning cell adhesion by direct nanostructuring silicon into cell repulsive/adhesive patterns

Developing platforms that allow tuning cell functionality through incorporating physical, chemical, or mechanical cues onto the material surfaces is one of the key challenges in research in the field of biomaterials. In this respect, various approaches have been proposed and numerous structures have been developed on a variety of materials. Most of these approaches, however, demand a multistep process or post-chemical treatment. Therefore, a simple approach would be desirable to develop bio-functionalized platforms for effectively modulating cell adhesion and consequently programming cell functionality without requiring any chemical or biological surface treatment. This study introduces a versatile yet simple laser approach to structure silicon (Si) chips into cytophobic/cytophilic patterns in order to modulate cell adhesion and proliferation. These patterns are fabricated on platforms through direct laser processing of Si substrates, which renders a desired computer-generated configuration into patterns. We investigate the morphology, chemistry, and wettability of the platform surfaces. Subsequently, we study the functionality of the fabricated platforms on modulating cervical cancer cells (HeLa) behaviour. The results from in vitro studies suggest that the nanostructures efficiently repel HeLa cells and drive them to migrate onto untreated sites. The study of the morphology of the cells reveals that cells evade the cytophobic area by bending and changing direction. Additionally, cell patterning, cell directionality, cell channelling, and cell trapping are achieved by developing different platforms with specific patterns. The flexibility and controllability of this approach to effectively structure Si substrates to cell-repulsive and cell-adhesive patterns offer perceptible outlook for developing bio-functionalized platforms for a variety of biomedical devices. Moreover, this approach could pave the way for developing anti-cancer platforms that selectively repel cancer cells while favoring the adhesion of normal cells. - Highlights: • Si platforms with cytophobic/philic patterns were developed to program cell growth. • Both nanotopography and chemistry contributed to the cytophobic property. • Cytophobic zones efficiently repel and drive HeLa cells to migrate to adhesive sites. • The approach enables cell patterning, directionality, channelling, and trapping. • This approach paves the way for developing anti-cancer platforms.

60 APPLIED LIFE SCIENCES↗

Pilot Sensorimotor and Cardiovascular Results from the Joint Russian/U.S. Field Test

The primary goal of this research is to determine functional abilities associated with long-duration space flight crews beginning as soon after landing as possible (< 2 hours) with an additional two follow-up measurements sessions on the day of landing. This goal has both sensorimotor and cardiovascular elements, including evaluations of NASA's new anti-orthostatic compression garment and the Russian Kentavr garment. Functional sensorimotor measurements will include, but are not limited to, assessing hand/eye coordination, standing from a seated position (sit-to-stand), walking normally without falling, measurement of dynamic visual acuity, discriminating different forces generated with both the hands and legs, recovering from a fall (standing from a prone position), coordinated walking involving tandem heel-to-toe placement, and determining postural ataxia while standing. The cardiovascular portion of the investigation includes measuring blood pressure and heart rate during a timed stand test in conjunction with postural ataxia testing (quiet stance sway) as well as cardiovascular responses during the other functional tasks. In addition to the immediate post-landing collection of data for the full FT, postflight data is being acquired twice more within the 24 hours after landing and will continue over the subsequent weeks until functional sensorimotor and cardiovascular responses have returned to preflight normative values. The PFT represents a initial evaluation of the feasibility of testing in the field, and is comprised of a jointly agreed upon subset of tests from the full FT and relies heavily on Russia's Institute of Biomedical Problems Sensory-Motor and Countermeasures Laboratories for content and implementation. The PFT has been collected on several ISS missions. Testing on the U.S. side has included: (1) a sit-to-stand test, (2) recovery from a fall where the crewmember began in the prone position on the ground and then stood for 3 minutes while cardiovascular stability was determined and postural ataxia data were acquired, and (3) a tandem heel-to-toe walk test to determine changes in the central locomotor program. Video, cardiovascular parameters (heart rate and blood pressure), data from bodyworn inertial sensors, and severity of postflight motion sickness were collected during each test session. Our Russian investigators have added measurements associated with: (a) obstacle avoidance, (b) muscle compliance and (c) postural adjustments to perturbations (push) applied to the subject's chest area. The level of functional deficit observed in the crew tested to date is typically beyond what was expected and is clearly triggered by the acquisition of gravity loads immediately after landing when the demands for crew intervention in response to emergency operations will be greatest. Clearly measureable performance parameters such as ability to perform a seat egress, recover from a fall or the ability to see clearly when walking, and related physiologic data (orthostatic responses) are required to provide an evidence base for characterizing programmatic risks and the degree of variability among crewmembers for exploration missions where the crew will be unassisted after landing. Overall, these early functional and related physiologic measurements will allow the estimation of nonlinear sensorimotor and cardiovascular recovery trends that have not been previously captured

Reschke, M. F.↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

Advancing Additive Manufacturing Through Artificial Intelligence–Powered, High-Throughput, Nondestructive Characterization and Process Optimization

This Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and ZEISS Industrial Metrology has demonstrated the transformative potential of artificial intelligence (AI)-enabled x-ray computed tomography (XCT) to accelerate the qualification and certification of additively manufactured (AM) parts. At the core of this effort is Simurgh, an AI-powered XCT reconstruction framework jointly advanced by ORNL and ZEISS that integrates computer-aided design (CAD) models, physics-based simulations, and deep learning to overcome the long-standing challenges of metal artifact correction, long scan durations, and limited flaw detectability in dense and geometrically complex components. Simurgh enables high-throughput, high-quality 3D reconstruction from sparse and fast scans, which reduces XCT acquisition times by more than an order of magnitude and simultaneously improves defect detection limits by up to fourfold compared with industry-standard approaches. This capability reduces scan costs by more than 50%, lowers labor overhead, and makes XCT characterization economically viable for routine industrial use. By enabling reliable flaw detection in minutes rather than hours, Simurgh facilitates real-time feedback loops for process parameter optimization, which was highlighted in a recent npj Computational Materials (a Nature journal) issue. In the published study, more than 100 alloy coupons were characterized within a single day. This work represents a tenfold acceleration in the development of novel AM alloys and processes compared with conventional workflows. The ZEISS collaboration has also demonstrated the scalability of Simurgh to diverse application domains, including aerospace, nuclear, automotive, and biomedical components; in these applications, ensuring structural integrity is paramount. By drastically reducing barriers to XCT adoption, this partnership has laid the foundation for digital twins and data-driven certification pipelines and directly addressed bottlenecks in qualifying new materials and designs. Together, ORNL and ZEISS have shown that Simurgh advances the state of the art in nondestructive evaluation and aligns with the broader mission of enabling Industry 4.0 manufacturing ecosystems, in which intelligent, cost-effective, rapid quality assurance is integral to accelerating innovation and ensuring safety in critical applications.

36 MATERIALS SCIENCE↗

WE-G-213-00: History Symposium: Radiological Physics Pioneers: Roentgen and the AAPM Award Eponyms - William Coolidge, Edith Quimby, and Marvin Williams - Who Were They and What Did They Do?

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

Effects of Strong Electronic Coupling in Chlorin and Bacteriochlorin Dyads

Achieving tunable, intense near-infrared absorption in molecular architectures with properties suitable for solar light harvesting and biomedical studies is of fundamental interest. Herein, we report the photophysical, redox, and molecular-orbital characteristics of nine hydroporphyrin dyads and associated benchmark monomers that have been designed and synthesized to attain enhanced light harvesting. Each dyad contains two identical hydroporphyrins (chlorin or bacteriochlorin) connected by a linker (ethynyl or butadiynyl) at the macrocycle β-pyrrole (3- or 13-) or meso (15-) positions. The strong electronic communication between constituent chromophores is indicated by the doubling of prominent absorption features, split redox waves, and paired linear combinations of frontier molecular orbitals. Relative to the benchmarks, the chlorin dyads in toluene show substantial bathochromic shifts of the long-wavelength absorption band (17-31 nm), modestly reduced singlet excited-state lifetimes (τ S = 3.6-6.2 ns vs 8.8-12.3 ns), and increased fluorescence quantum yields (Φ f = 0.37-0.57 vs 0.34-0.39). The bacteriochlorin dyads in toluene show significant bathochromic shifts (25-57 nm) and modestly reduced τ S (1.6-3.4 ns vs 3.5-5.3 ns) and Φ f (0.09-0.19 vs 0.17-0.21) values. The τ S and Φ f values for the bacteriochlorin dyads are reduced substantially (up to ~20-fold) in benzonitrile. The quenching is due primarily to the increased S 1 → S o internal conversion that is likely induced by increased contribution of charge-resonance configurations to the S 1 excited state in the polar medium. Lastly, the fundamental insights gained on the physicochemical properties of the strongly coupled hydroporphyrin dyads may aid utilization in solar-energy conversion and photomedical research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-G-213-01: Roentgen and the Birth of Modern Medical Physics

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

WE-G-213-02: The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who Were They and What Did They Do?

Roentgen and the Birth of Modern Medical Physics – Perry Sprawls Wilhelm Roentgen is well known for his discovery of x-radiation. What is less known and appreciated is his intensive research following the discovery to determine the characteristics of the “new kind of radiation” and demonstrate its great value for medical purposes. In this presentation we will imagine ourselves in Roentgen’s mind and follow his thinking, including questions and doubts, as he designs and conducts a series of innovative experiments that provided the foundation for the rapid growth of medical physics. Learning Objectives: Become familiar with the personal characteristics and work of Prof. Roentgen that establishes him as an inspiring model for the medical physics profession. Observe the thought process and experiments that determined and demonstrated the comprehensive characteristics of x-radiation. The AAPM Award Eponyms: William D. Coolidge, Edith H. Quimby, and Marvin M.D. Williams - Who were they and what did they do? – Lawrence N. Rothenberg William David Coolidge (1873–1975) William Coolidge was born in Hudson, NY in 1873. He obtained his BS at the Massacusetts Institute of Technology in 1896. Coolidge then went to the University of Leipzig, Germany for graduate study with physicists Paul Drude and Gustave Wiedemann and received a Ph.D. in 1899. While in Germany he met Wilhelm Roentgen. Coolidge returned to the US to teach at MIT where he was associated with Arthur A. Noyes of the Chemistry Department, working on the electrical conductivity of aqueous solutions. Willis R. Whitney, under whom Coolidge had worked before going to Germany, became head of the newly formed General Electric Research Laboratory and he invited Coolidge to work with him. In 1905, Coolidge joined the staff of the GE laboratory and was associated with it for the remainder of his life. He developed ductile tungsten filaments to replace fragile carbon filaments as the material for electric light bulb filaments. Until that innovation light bulbs had a notoriously short life. He later incorporated the ductile tungsten as a filament material for a hot cathode, fully evacuated x-ray tube, first described in 1912, which allowed higher current and x-ray output, and greater reliability than had previously been possible. These “Coolidge x-ray tubes” were far superior to the cold cathode, partial pressure gas x-ray tubes that had been in use since Roentgen’s discovery of x-rays in 1895. The Coolidge tube with incremental developments is now the key component for x-ray production in all of our modern x-ray imaging devices, such as CT scanners, interventional radiology systems, and mammography units. Coolidge was also involved in the development of sectional x-ray tubes for research and treatment that were initially designed to reach 800 kV. Additional improvements led to 1 MV and 2 MV devices. In 1932 Coolidge became director of the General Electric Research Laboratory, and in 1940, was made Vice-President and Director of Research. In 1945 he retired and was named Director Emeritus of the laboratory. Coolidge held 83 patents and was recognized for these and many other achievements by election to the National Academy of Engineers, a place in the Engineering Hall of Fame and the National Inventor’s Hall of Fame. The AAPM’s highest honor, the Coolidge Award, was named after him. He accepted Honorary Membership in the AAPM and was the first recipient of the AAPM Coolidge Award, which was presented to him in a special ceremony in Schenectady, NY in 1972 when he was 100 years old. Edith Hinckley Quimby (1891–1982) Edith Quimby was born in Rockford, IL in 1891. She graduated from Whitman College in Walla Walla, WA with a B.S. in 1913, and then obtained a masters degree from the University of California at Berkeley. Later in her career, after many significant achievements, Quimby was awarded honorary doctorates by Whitman College and Rutgers University. Edith Quimby was hired by Giacchino Failla as a radiation physicist at Memorial Hospital for Cancer in New York City. Failla had studied with Madame Curie and obtained his doctoral degree in her laboratory. After many groundbreaking medical physics studies from 1919 until 1942, they both moved to Columbia University. Dr. Quimby developed a widely employed dosimetry system for single plane implants with radium and radon seeds, and a dosimetry methodology for internal radionuclides. She was author of more than 75 scientific publications, and of significant textbooks including the first comprehensive physics textbook for radiologists “Physical Foundations of Radiology”, which was co-authored with Otto Glasser, Lauriston Taylor and James Weatherwax in the first edition, with Russell Morgan added for the second edition and Paul Goodwin for the fourth edition. With Sergei Feitelberg, M.D. she published two editions of “Radioactive Isotopes in Medicine and Biology: Basic Physics and Instrumentation”. Quimby became a renowned examiner for the American Board of Radiology when the third ABR examination, given in 1936, added physics. She served as President of the American Radium Society, received the RSNA Gold Medal, and also numerous prestigious awards given to women in science. Edith Quimby was a Charter Member of AAPM. The AAPM Lifetime Achievement Award was renamed the Edith H. Quimby Lifetime Achievement Award in her honor in 2011. Marvin Martin Dixon Williams (1902–1981) Marvin Williams was born in Walla Walla, WA in 1902, and attended the same college as Edith Quimby, graduating from Whitman College in 1926. He was greatly influenced to go into medical physics by her accomplishments. During his early career, Williams worked with James Weatherwax in Philadelphia while he was working toward an M.S. from the University of Pennsylvania. In 1931 Williams was awarded a Ph.D. in Biophysics from the University of Minnesota, with the work actually performed at the Mayo Clinic Graduate School of the University. While completing his Ph.D. studies, Marvin met Dr. Paul Hodges who had returned from the Peiping Union Medical College in Peiping (now Beijing), China. Hodges suggested that a physicist be sent to Peiping to install x-ray therapy equipment and a radon plant. Williams accepted the position and, in 1931, he and his wife Orpha left for China. Before going to China, Williams had spent time with the physics group at Memorial Hospital to learn about the operation of a radon plant. In China, he constructed the radon plant, employing 0.25 g of radium, and also installed the x-ray therapy unit. Williams and his wife returned to the US in 1935, and he accepted a research position at the Mayo Clinic. In 1950, he became Professor of Biophysics at Mayo, where he taught physics and biophysics until his retirement in 1967. Williams was also very active in the American Board of Radiology where, from 1944 through 1977, he examined over 3000 radiologists and 250 physicists. Marvin Williams was a Charter member of AAPM, served as the fourth President of AAPM in 1963, and was the fourth recipient the AAPM Coolidge Award in 1975. The Marvin Williams Award was originally established as the highest award of the American College of Medical Physics. When various functions of the ACMP were absorbed into the AAPM in 2012, the Marvin M D Williams Professional Achievement Award became one of the AAPM’s highest honors. Learning Objectives: Become familiar with the persons in whose honor the three major AAPM Award are named Learn about the achievements and activities which influenced the AAPM to name these awards in their honor.

60 APPLIED LIFE SCIENCES↗

Planetary protection implementation on future Mars lander missions

A workshop was convened to discuss the subject of planetary protection implementation for Mars lander missions. It was sponsored and organized by the Exobiology Implementation Team of the U.S./Russian Joint Working Group on Space Biomedical and Life Support Systems. The objective of the workshop was to discuss planetary protection issues for the Russian Mars '94 mission, which is currently under development, as well as for additional future Mars lander missions including the planned Mars '96 and U.S. MESUR Pathfinder and Network missions. A series of invited presentations was made to ensure that workshop participants had access to information relevant to the planned discussions. The topics summarized in this report include exobiology science objectives for Mars exploration, current international policy on planetary protection, planetary protection requirements developed for earlier missions, mission plans and designs for future U.S. and Russian Mars landers, biological contamination of spacecraft components, and techniques for spacecraft bioload reduction. In addition, the recent recommendations of the U.S. Space Studies Board (SSB) on this subject were also summarized. Much of the discussion focused on the recommendations of the SSB. The SSB proposed relaxing the planetary protection requirements for those Mars lander missions that do not contain life detection experiments, but maintaining Viking-like requirements for those missions that do contain life detection experiments. The SSB recommendations were found to be acceptable as a guide for future missions, although many questions and concerns about interpretation were raised and are summarized. Significant among the concerns was the need for more quantitative guidelines to prevent misinterpretation by project offices and better access to and use of the Viking data base of bioassays to specify microbial burden targets. Among the questions raised were how will the SSB recommendations be integrated with existing Committee on Space Research (COSPAR) policy and how will they apply to and affect Mars '94, Mars '96, MESUR Pathfinder, and MESUR Network missions? One additional topic briefly considered at the workshop was the identification of some issues related to planetary protection considerations for Mars sample return missions. These issues will form the basis for a follow-on joint U.S./Russian workshop on that subject.

Howell, Robert↗

Magnetic Resonance–Guided High-Intensity Focused Ultrasound Hyperthermia for Recurrent Rectal Cancer: MR Thermometry Evaluation and Preclinical Validation

Purpose: To evaluate the feasibility of magnetic resonance–guided high-intensity focused ultrasound (MR-HIFU) mild hyperthermia in deep tissue targets for enhancing radiation therapy and chemotherapy in the context of recurrent rectal cancer. A preclinical study was performed to evaluate the safety and performance of MR-HIFU mild hyperthermia. A prospective imaging study was performed in volunteers with rectal cancer to evaluate MR thermometry quality near the rectum and accessibility of rectal tumors using MR-HIFU. Methods and Materials: Mild hyperthermia was performed in pig thigh (9 sonications, 6 pigs) using a clinical MR-HIFU system. Targets near the rectal wall and deep thigh were evaluated. Thermal maps obtained in 6 planes every 3.2 seconds were used to control sonications in 18-mm diameter treatment regions at temperatures of 42°C to 42.5°C for 10 to 60 minutes. Volunteer imaging-only studies to assess the quality of MR thermometry (without heating) were approved by the institutional research ethics board. Anatomic and MR thermometry images were acquired in consenting volunteers with rectal cancer. In 3 of 6 study participants, rectal filling with saline was used to reduce motion-related MR thermometry artifacts near the tumor. Results: In pigs, mean target temperature matched the desired hyperthermia temperature within 0.2°C; temporal standard deviation ≤0.5°C. With optimized control thresholds, no undesired tissue damage was observed. In human volunteers, MR temperature measurements had adequate precision and stability, especially when rectal filling was used to reduce bowel motion. Conclusions: In pigs, MR-HIFU can safely deliver mild hyperthermia (41°C-43°C) to a targeted volume for 30 minutes. In humans, careful patient selection and preparation will enable adequate targeting for recurrent rectal cancers and sufficient MR temperature mapping stability to control mild hyperthermia. These results enable human trials of MR-HIFU hyperthermia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Neuromorphic ionic computing in droplet interface synapses

Ionic devices with memory capabilities can emulate neural functionality, enabling neuromorphic computing and biomedical applications. In this study, we report an ionic spiking synapse based on aqueous droplet interface bilayer assembly. Under stepwise triangular voltages, the device displays coupled memcapacitive-memristive behavior, showing noncrossing pinched hysteretic I-V loops. This hysteretic ion dynamics can be regulated by modifying bilayer components, reconstituting protein channels, or adjusting droplet assembly configuration. Droplet interface synapses (DIS) exhibit fundamental neuromorphic behaviors such as paired-pulse facilitation/depression, spike rate–dependent plasticity, Hebbian learning, and short-term associative learning under classical conditioning. We also used reservoir computing with DIS to implement two learning algorithms: a classification algorithm that recognizes handwritten digits and a reinforcement learning algorithm that learns to play a board game of tic-tac-toe.

Li, Zhongwu [Lawrence Livermore National Laborator↗

Fourth Annual Workshop on Space Operations Applications and Research (SOAR 90)

The papers presented at the Space Operations, Applications and Research (SOAR) Symposium, hosted by the Air Force Space Technology Center and held at Albuquerque, New Mexico, on June 26-28, 1990, are documented in these proceedings. Over 150 technical papers were presented at the Symposium, which was jointly sponsored by the Air Force and NASA Johnson Space Center. the technical areas included were: Automation and Robotics, Environmental Interactions, Human Factors, Intelligent Systems, and Life Sciences. NASA and Air Force programmatic overviews and panel sessions were also held in each technical area. These proceedings, along with the comments by technical area coordinators and session chairmen, will be used by the Space Operation Technology Subcommittee (SOTS) of the Air Force Systems Command and NASA Space Technology Interdependency Group (STIG) to assess the status of the technology, as well as the joint projects/activities in various technical areas. The Symposium proceedings include papers presented by experts from NASA, the Air Force, universities, and industries in various disciplines.

Life Sciences↗

Coupling a recurrent neural network to SPAD TCSPC systems for real-time fluorescence lifetime imaging

Fluorescence lifetime imaging (FLI) has been receiving increased attention in recent years as a powerful diagnostic technique in biological and medical research. However, existing FLI systems often suffer from a tradeoff between processing speed, accuracy, and robustness. Inspired by the concept of Edge Artificial Intelligence (Edge AI), we propose a robust approach that enables fast FLI with no degradation of accuracy. This approach couples a recurrent neural network (RNN), which is trained to estimate the fluorescence lifetime directly from raw timestamps without building histograms, to SPAD TCSPC systems, thereby drastically reducing transfer data volumes and hardware resource utilization, and enabling real-time FLI acquisition. We train two variants of the RNN on a synthetic dataset and compare the results to those obtained using center-of-mass method (CMM) and least squares fitting (LS fitting). Results demonstrate that two RNN variants, gated recurrent unit (GRU) and long short-term memory (LSTM), are comparable to CMM and LS fitting in terms of accuracy, while outperforming them in the presence of background noise by a large margin. To explore the ultimate limits of the approach, we derive the Cramer-Rao lower bound of the measurement, showing that RNN yields lifetime estimations with near-optimal precision. To demonstrate real-time operation, we build a FLI microscope based on an existing SPAD TCSPC system comprising a 32 x 32 SPAD sensor named Piccolo. Four quantized GRU cores, capable of processing up to 4 million photons per second, are deployed on the Xilinx Kintex-7 FPGA that controls the Piccolo. Powered by the GRU, the FLI setup can retrieve real-time fluorescence lifetime images at up to 10 frames per second. The proposed FLI system is promising and ideally suited for biomedical applications, including biological imaging, biomedical diagnostics, and fluorescence-assisted surgery, etc.

47 OTHER INSTRUMENTATION↗