Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Energy-storage of a prescribed impedance

Reflector antenna of the parabolic type offers complete control of its aperature illumination function. The antennas beam width can be changed easily by excitation of various amounts of the line-source feed. The conical reflector collimates a beam when the feed complies with certain geometric constraints.

Seaton, A. F.↗

Modeling LANSCE Line D and RI Beamlines in Elegant and Impact-T

This technical report describes models in Elegant and Impact-T of two LANSCE high-energy beamlines: LineD and Ring Injection. These two beamlines transport the 800 MeV H- beam from the exit of the 805 MHz Linac to the entrance of the PSR. Computer models of all LANSCE high-energy beamlines exist in Transport but include a limited model of the space charge forces. A motivation for using Elegant as an optional beam dynamics code is that the existing model of the PSR is in Elegant, therefore enabling the modeling of the full beam injection scheme. Also, Elegant is a modern code being used by a large accelerator physics community which makes the calculation results more reliable. The drawback is that Elegant has also a limited space charge force model. Therefore, we have opted to include the Particle-In-Cell (PIC) code Impact-T as an alternate beam dynamics code to verify the Elegant calculations. We will use the new Line D and RI models to study beam halo in the transport leading into the PSR, and to evaluate collimation schemes as part of the PSR upgrade. The new models can also be readily used in support of other LANSCE activities.

43 PARTICLE ACCELERATORS↗

Status of the CBETA splitter common magnet design

The two common dipole magnets in each of the two CBETA splitter sections serve to direct the beams of 42, 78, 114 and 150 MeV from the linac or FFAG return loop exit into the separate splitter lines for path length adjustment and to direct the beams from the splitter into the linac or FFAG return loop entrance. Here we report the results of design and tracking studies based on the Opera V18R2 software. The choice of the H-magnet design included consideration of using the coil design developed for the internal splitter H-dipoles by Elytt Energy. Considerations of transverse space constraints and the bend angle of about 30 degrees for the 42-MeV beam led to the adoption of a T-shape for the pole. The XYZ magnet dimensions are 34 × 42 × 16 cm. The central field value is 3.6-3.9 kG, but the magnet can operate as high as 4.9 kG, allowing for tests of a beam energy as high as 54 MeV in the S1 splitter line. We include results of tracking studies showing optimal placement of the magnets based on bend angle uniformity for the four beam energies. The project now proceeds to the full engineering design and fabrication to be performed by Elytt Energy.

43 PARTICLE ACCELERATORS↗

SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of the MR-Linac system studied in this work.

60 APPLIED LIFE SCIENCES↗

Laboratory Calibrations of Fe xii–xiv Line-Intensity Ratios for Electron Density Diagnostics

In this work, we have used an electron beam ion trap to measure electron-density-diagnostic line-intensity ratios for extreme ultraviolet lines from Fe xii, xiii, and xiv at wavelengths of ≈185–205 and 255–276 Å. These ratios can be used as density diagnostics for astrophysical spectra and are especially relevant to solar physics. We found that density diagnostics using the Fe xiii 196.53/202.04 and the Fe xiv 264.79/274.21 and 270.52A/274.21 line ratios are reliable using the atomic data calculated with the Flexible Atomic Code (FAC). On the other hand, we found a large discrepancy between the FAC theory and experiment for the commonly used Fe xii (186.85 + 186.88)/195.12 line ratio. These FAC theory calculations give results similar to the data tabulated in CHIANTI, which are commonly used to analyze solar observations. Our results suggest that the discrepancies seen between solar coronal density measurements using the Fe xii (186.85 + 186.88)/195.12 and Fe xiii 196.54/202.04 line ratios are likely due to issues with the atomic calculations for Fe xii.

74 ATOMIC AND MOLECULAR PHYSICS↗

Concentrated ion beam emitted from an enlarged cylindrical-anode-layer Hall plasma accelerator and mechanism

An enlarged cylindrical-anode-layer Hall plasma accelerator with an outlet diameter of 150 mm is experimentally demonstrated to produce a concentrated ion beam, especially at a high discharge voltage, with a high current utilization efficiency of up to {approx}0.9. Numerical investigation based on the three-dimensional particle-in-cell method is performed to study the ion dynamics and elucidate the origin of the ion beam characteristics. The simulation results reveal that the equipotential lines play an important role in the surface near the anode emitting the ions. The ion emitting surface is determined by the magnetic field lines near the anode and the magnetic mirror contributes to the concentrated beam significantly. The high current utilization efficiency results from the appropriate obliquity of the magnetic mirror.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelength measurement of n=3 to n=3 transitions in highly charged tungsten ions

3s{sub 1/2}-3p{sub 3/2} and 3p{sub 1/2}-3d{sub 3/2} transitions have been studied in potassiumlike W{sup 55+} through neonlike W{sup 64+} ions at the electron-beam ion trap facility in Livermore. The wavelengths of the lines have been measured in high resolution relative to well known reference lines from oxygen and nitrogen ions. Using the high-energy SuperEBIT electron-beam ion trap and an R=44.3 m grazing-incidence soft-x-ray spectrometer, the lines were observed with a cryogenic charge-coupled device camera. The wavelength data for the sodiumlike and magnesiumlike tungsten lines are compared with theoretical predictions for ions along the isoelectronic sequences.

74 ATOMIC AND MOLECULAR PHYSICS↗

The ionization structure of the Orion nebula: Infrared line observations and models

Observations of the (O III) 52 and 88 micron lines and the (N III) 57 micron line have been made at 6 positions and the (Ne III) 36 micron line at 4 positions in the Orion Nebula to probe its ionization structure. The measurements, made with a -40" diameter beam, were spaced every 45" in a line south from and including the Trapezium. The wavelength of the (Ne III) line was measured to be 36.013 + or - 0.004 micron. Electron densities and abundance ratios of N(++)/O(++) have been calculated and compared to other radio and optical observations. Detailed one component and two component (bar plus halo) spherical models were calculated for exciting stars with effective temperatures of 37 to 40,000K and log g = 4.0 and 4.5. Both the new infrared observations and the visible line measurements of oxygen and nitrogen require T sub eff approx less than 37,000K. However, the double ionized neon requires a model with T sub eff more than or equal to 39,000K, which is more consistent with that inferred from the radio flux or spectral type. These differences in T sub eff are not due to effects of dust on the stellar radiation field, but are probably due to inaccuracies in the assumed stellar spectrum. The observed N(++)/O(++) ratio is almost twice the N(+)/O(+) ratio. The best fit models give N/H = 8.4 x 10 to the -5 power, O/H = 4.0 x 10 to the -4 power, and Ne/H = 1.3 x 10 to the -4 power. Thus neon and nitrogen are approximately solar, but oxygen is half solar in abundance. From the infrared O(++) lines it is concluded that the ionization bar results from an increase in column depth rather than from a local density enhancement.

Simpson, J. P.↗

A Foreshock Model for Interstellar Shocks of Solar Origin: Voyager 1 and 2 Observations

The Voyager 1 (V1) and Voyager 2 (V2) spacecraft were launched in 1977 on a mission to explore the outer planets and reach the heliopause, the boundary between the hot solar plasma and the relatively cool interstellar plasma. V1 reached the heliopause on 2012 August 25, at 121.6 au, and V2 reached the heliopause on 2018 November 5, at 119.0 au. One of their remarkable discoveries was the detection of shocks propagating into the interstellar plasma from energetic solar events. These shocks are typically preceded by electron plasma oscillations excited by electron beams streaming along interstellar magnetic field lines ahead of the shocks. The frequencies of the plasma oscillations have now provided radial electron density profiles in the outer heliosphere and in the interstellar medium to radial distances of more than 145 au. The oscillations are typically preceded by bursts of high-energy ∼5–100 MeV electrons. These electron bursts are interpreted as being due to the reflection (and acceleration) of cosmic-ray electrons by the shock at the time the shock first contacts the magnetic field line that passes through the spacecraft. Relative timing between the cosmic rays reflected by the shock and the onset of the plasma oscillations allow us, for the first time, to estimate the energy, ∼20–100 eV, of the electron beams responsible for the plasma oscillations. These observations are combined into a self-consistent model called the foreshock model that describes the interaction of shocks of solar origin with the interstellar plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Observations of Large-amplitude Solitary Waves in Electron Beams

The longitudinal dynamics of space charge dominated beams plays an important role in particle accelerators and other applications such as heavy ion fusion and free electron lasers (FELs). All beams are space-charge dominated near the source. F urthermore, the longitudinal profile is not necessarily an ideal mathematical function. By means of experiments on the University of Maryland Electron Ring (UMER), we studied how a perturbation to the line charge density could affect the beam propagation. By varying the initial amplitude of the perturbation, we access nonlinear space charge physics. When starting with large-amplitude perturbations, we have observed, for the first time in charged particle beams, solitary waves for which the nonlinear steep ening exactly balances the wave dispersion, leading to persistent waves that preserves their shape over a long distance. This paper presents the results of the soliton experiments, including systematic studies of the dependence of the soliton propagation on beam current, perturbation level and width. The data is compared with theory and simulation.

43 PARTICLE ACCELERATORS↗

Simulations of pulsed electron beam injection during active experiments

Two-dimensional electromagnetic particle simulations are used to investigate the characteristics of the spacecraft charging, particle acceleration, and wave emissions during beam injection, turnoff and subsequent pulsing of the beam. It is shown that, during beam injection, the beam current is neutralized by a spatially separate return current region extending several tens of meters from the beam region, with the currents being closed across the field lines by the perpendicular acceleration of ambient plasma ions into the beam region. After beam turnoff, this current system reverses after a time lag of about an ion plasma period. The current reversal is accompanied by prolonged electron collection by the spacecraft near the beam region, preferential ion collection by sections of the spacecraft magnetically connected to the initial return current regions, and the creation of hot plasma extending well into the return current regions. Because of the time lag, the currents induced in the plasma during periodic beam injection can be strongly modified from the imposed beam current.

Winglee, R. M.↗

Coronagraphic Notch Filter for Raman Spectroscopy

A modified coronagraph has been proposed as a prototype of improved notch filters in Raman spectrometers. Coronagraphic notch filters could offer alternatives to both (1) the large and expensive double or triple monochromators in older Raman spectrometers and (2) holographic notch filters, which are less expensive but are subject to environmental degradation as well as to limitations of geometry and spectral range. Measurement of a Raman spectrum is an exercise in measuring and resolving faint spectral lines close to a bright peak: In Raman spectroscopy, a monochromatic beam of light (the pump beam) excites a sample of material that one seeks to analyze. The pump beam generates a small flux of scattered light at wavelengths slightly greater than that of the pump beam. The shift in wavelength of the scattered light from the pump wavelength is known in the art as the Stokes shift. Typically, the flux of scattered light is of the order of 10 7 that of the pump beam and the Stokes shift lies in the wave-number range of 100 to 3,000 cm 1. A notch filter can be used to suppress the pump-beam spectral peak while passing the nearby faint Raman spectral lines. The basic principles of design and operation of a coronagraph offer an opportunity for engineering the spectral transmittance of the optics in a Raman spectrometer. A classical coronagraph may be understood as two imaging systems placed end to end, such that the first system forms an intermediate real image of a nominally infinitely distant object and the second system forms a final real image of the intermediate real image. If the light incident on the first telescope is collimated, then the intermediate image is a point-spread function (PSF). If an appropriately tailored occulting spot (e.g., a Gaussian-apodized spot with maximum absorption on axis) is placed on the intermediate image plane, then the instrument inhibits transmission of light from an on-axis source. However, the PSFs of off-axis light sources are formed off axis - that is, away from the occulting spot - so that they become refocused onto the final image plane.

Cohen, David↗

Spectroscopy of {sup 32}Ne and the 'Island of Inversion'

We report on the first spectroscopic study of the N=22 nucleus {sup 32}Ne at the newly completed RIKEN Radioactive Ion Beam Factory. A single gamma-ray line with an energy of 722(9) keV was observed in both inelastic scattering of a 226 MeV/u {sup 32}Ne beam on a carbon target and proton removal from {sup 33}Na at 245 MeV/u. This transition is assigned to the deexcitation of the first J{sup p}i=2{sup +} state in {sup 32}Ne to the 0{sup +} ground state. Interpreted through comparison with state-of-the-art shell-model calculations, the low excitation energy demonstrates that the 'island of inversion' extends to at least N=22 for the Ne isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Self-consistent inclusion of space-charge in the traveling wave tube

It is shown how the complete field of the electron beam may be incorporated into the transmission line model theory of the traveling wave tube (TWT). The fact that the longitudinal component of the field due to the bunched beam is not used when formulating the beam-to-circuit coupling equation is not well-known. The fundamental partial differential equation for the traveling wave field is developed and compared with the older (now standard) one. The equation can be solved numerically using the same algorithms, but now the coefficients can be updated continuously as the calculation proceeds down the tube. The coefficients in the older equations are primarily derived from preliminary measurements and some trial and error. The newer coefficients can be found by a recursive method, since each has a well defined physical interpretation and can be calculated once a reasonable first trial solution is postulated. The results of the new expression were compared with those of the older forms, as well as to a field theory model to show the ease in which a reasonable fit to the field prediction is obtained. A complete summary of the existing transmission line modeling of the TWT is given to explain the somewhat vague ideas and techniques in the general area of drifting carrier-traveling circuit wave interactions. The basic assumptions and inconsistencies of the existing theory and areas of confusion in the general literature are examined and hopefully cleared up.

Freeman, Jon C.↗

Supersonic helium beam diagnostic for fluctuation measurements of electron temperature and density at the Tokamak TEXTOR

A supersonic helium beam diagnostic, based on the line-ratio technique for high resolution electron density and temperature measurements in the plasma edge (r/a > 0.9) was designed, built, and optimised at TEXTOR (Torus Experiment for Technology Oriented Research). The supersonic injection system, based on the Campargue skimmer-nozzle concept, was developed and optimised in order to provide both a high neutral helium beam density of n{sub 0}= 1.5 Multiplication-Sign 10{sup 18} m{sup -3} and a low beam divergence of {+-}1 Degree-Sign simultaneously, achieving a poloidal resolution of {Delta}{sub poloidal}= 9 mm. The setup utilises a newly developed dead volume free piezo valve for operation in a high magnetic field environment of up to 2 T with a maximum repetition rate of 80 Hz. Gas injections are realised for a duration of 120 ms at a repetition rate of 2 Hz (duty cycle 1/3). In combination with a high sensitivity detection system, consisting of three 32 multi-channel photomultipliers (PMTs), measurements of edge electron temperature and density with a radial resolution of {Delta}{sub radial}= 2 mm and a maximum temporal resolution of {Delta}t Asymptotically-Equal-To 2 {mu}s (470 kHz) are possible for the first time. The diagnostic setup at TEXTOR is presented. The newly developed injection system and its theoretical bases are discussed. The applicability of the stationary collisional-radiative model as basis of the line-ratio technique is shown. Finally, an example of a fluctuation analysis demonstrating the unique high temporal and spatial resolution capabilities of this new diagnostic is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacancy-type defects in In{sub x}Ga{sub 1-x}N alloys probed using a monoenergetic positron beam

Native defects in In{sub x}Ga{sub 1-x}N grown by plasma-assisted molecular beam epitaxy were probed by a monoenergetic positron beam. Doppler broadening spectra of the annihilation radiation were measured, and these were compared with results obtained using first-principles calculation. The defect concentration increased with increasing In composition x and reached the maximum at x = 0.44{approx}0.56. A clear correlation between the line-width of photoluminescence and the defect concentration was obtained. The major defect species detected by positron annihilation was identified as cation vacancies coupled with multiple nitrogen vacancies (V{sub N}s), and their introduction mechanism is discussed in terms of the strain energy due to bond-length/angle distortions and the suppression of the V{sub N} formation energy by neighboring In atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗