Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Computer analysis of arteriograms

A computer system has been developed to quantify the degree of atherosclerosis in the human femoral artery. The analysis involves first scanning and digitizing angiographic film, then tracking the outline of the arterial image and finally computing the relative amount of roughness or irregularity in the vessel wall. The image processing system and method are described.

Selzer, R. H.↗

Left ventricular function during lower body negative pressure

The response of the human left ventricle to lower body negative pressure (LBNP) and the relation between left ventricular function and hemodynamic response were investigated. Ventricular function curves relating stroke volume to end-diastolic volume were obtained in 12 normal men. Volume data were derived from echocardiographic measurements of left ventricular end-systolic and end-diastolic diameters at rest and during lower body negative pressure (LBNP) at minus 40 mm Hg. End-diastolic volume decreased by 19% and stroke volume by 22%. There were no significant changes in heart rate, arterial blood pressure, or end-systolic volume. Thus, moderate levels of LBNP significantly reduce preload and stroke volume without affecting contractile state. The absence of significant changes in heart rate and arterial blood pressure in the presence of a significant reduction in stroke volume is consistent with an increase in systemic peripheral resistance mediated by low-pressure baroreceptors.

Ahmad, M.↗

Basic results of the medical research conducted during the flight of two crews on the Salyut-5 orbital station

The study of the effect of space factors, especially weightlessness, on man, taking into account prophylactic measures and devices to counteract that effect was part of the program for two flights on the Salyut 5 orbital station. Information from the equipment on board was transmitted telemetrically including: an electrocardiogram; a sphygmogram of carotid and femoral arteries; a kinetocardiogram; a tacho-oscillogram of the humeral artery, perimetric oscillations of the femur, venous pulse and pressure in the jugular veins, vital capacity of the lungs, respiration rate and lung ventilation. Stress factors, metabolism, biological and bacteriological and other tests were included. A comparison was made between these data and pre- and postflight test result.

Source record↗

Influence of low and high pressure baroreceptors on plasma renin activity in humans

The effects of low and high pressure baroreceptors on plasma renin activity (immunoassay) were evaluated using graded lower body suction (LBS) in six healthy men. LBS at -10 and -20 mmHg for 10 min decreased central venous pressure without changing arterial pressure and thereby presumably reduced low but not high pressure baroreceptor inhibition of renin release. LBS at these levels produced forearm vasoconstriction, but did not increase renin. LBS at -40 mmHG decreased central venous and arterial pulse pressure and thus reduced both low and high pressure baroreceptor inhibition. LBS at this level produced forearm vasoconstriction and tachycardia and increased renin. In summary, reduction in low pressure baroreceptor inhibition in humans did not increase renin in the presence of physiological tonic inhibition from high pressure baroreceptors. Increases in renin did not occur until there was combined reduction of high and low pressure baroreceptor inhibition on plasma renin activity.

Mark, A. L.↗

Cryogenic thermal diode heat pipes

The development of spiral artery cryogenic thermal diode heat pipes was continued. Ethane was the working fluid and stainless steel the heat pipe material in all cases. The major tasks included: (1) building a liquid blockage (blocking orifice) thermal diode suitable for the HEPP space flight experiment; (2) building a liquid trap thermal diode engineering model; (3) retesting the original liquid blockage engineering model, and (4) investigating the startup dynamics of artery cryogenic thermal diodes. An experimental investigation was also conducted into the wetting characteristics of ethane/stainless steel systems using a specially constructed chamber that permitted in situ observations.

Alario, J.↗

Rheoencephalography in Meniere's disease

Rheoencephalography (REG) was used on 35 patients with Meniere's disease to determine tonus and perfusion of cerebral vessels. The analysis took account of age, duration of the disease and presence or absence of cervical osteochondrosis. Hypertensive symptoms in the vertebro-basilar system predominated in the under 45 age group, while for the over 45 patients and those suffering for more than 5 years, hypertensive symptoms were likewise noted in the internal carotid arterial system. Signs of angiospasm were revealed both for patients with cervical osteochondrosis and without it. Hypertensive signs were noted in 88.5% of patients with Meniere's disease and as a rule they were noted in the entire vertebro-basilar system without respect to the presence or absence of concurrent cervical osteochondrosis and uni- or bilateral affection of the labyrinth; in patients over 45 who had suffered more than 5 years this also applied to the internal carotid arterial system. Identification of the condition of cerebral circulation and the planning of more effective therapy that influences vascular tone is made possible by REG.

Nikolayev, M. P.↗

Activity of the right cardiac ventricle and metabolism in healthy persons during an orthostatic test after short term immobilization

A 15 minute orthostatic test was performed on healthy male volunteers under conditions of catheterization of the right ventricle of the heart and the radial (or brachial) artery before and after 5 day bedrest in an antiorthostatic position of the body (with the foot of the bed raised 4.5 degrees). The change to a vertical position after immobilization was attended by a more marked increase in the rate of cardiac contractions, an increase of max dp/dt pressure in the right ventricle, and a decrease of cardiac and stroke indices. The decrease of the cardiac index was compensated for, to a certain measure, by a further increase in the extraction and utilization of O2 by the tissues. The arterial blood pH did not change essentially, while the decrease in pCO2 and content of standard bicarbonate was more marked.

Chestukhin, V. V.↗

Effect of prolonged hypokinesia on resistance of resistive vessels in rats

Under the effect of prolonged hypokinesia, the perfusion pressure in resistive vessels, measured under conditions of deep anesthesia and complete denervation, increased by approximately the same degree as arterial pressure in non-anesthetized animals. The increase in arterial, perfusion pressure and the resistance of resistive vessels in animals subjected to prolonged hypokinesia was accompanied by an increase in adrenoreactivity. During prolonged hypokinesia, partial obliteration of the vascular bed of the skeletal muscles plays a significant role in the observed increase in resistance of vessels of the extremities. The increase in adrenoreactivity of the vessels during hypokinesia may be realized as a partial case of an increase in the adrenoreactivity of structures whose innervation is disturbed.

Saltykova, V. A.↗

Discordance of exercise thallium testing with coronary arteriography in patients with atypical presentations

Eighty-one patients with diagnostically difficult clinical presentations suggesting coronary artery disease underwent symptom-limited maximal-exercise treadmill testing (ETT) and exercise radionuclide scanning with thallium-201 followed by coronary angiography. Results showed that in nearly half of the patients (47%) these tests were in agreement, while either exercise thallium or ETT was positive in 94% of patients with coronary artery disease. It was found that agreement between exercise thallium and ETT tests predicted disease in 92% of the instances or excluded disease in 82% of the instances. It is concluded that despite frequent discord between these two tests in 53% of the cases, a significant gain in exclusive diagnostic capability is realized when applied to a patient population anticipated to have a disease prevalence equal to the 67% encountered in this study.

Bungo, M. W.↗

Effect of water immersion on cardiopulmonary physiology at high gravity (+Gz)

The cardiopulmonary responses of eight male subject between 21-31 years exposed to 1, 2, and 3 Gz during immersion at 35 + or - 0.5 C to heart level and during control dry rides are studied. Ventilation, O2 consumption, the end-tidal pressure of CO2, heart frequency, cardiac output, functional residual capacity, and the arterial pressure of CO2 were measured. It is observed that as Gz increases ventilation, heart frequency, and O2 consumption increase, and the end-tidal and arterial pressures of CO2 decrease during dry rides, but are not altered during immersion. It is detected that the functional residual capacity is lower during immersion and decreases in both the dry and immersed state as Gz increases, and cardiac output decreases as Gz increases in dry rides. It is noted that changes produced by acceleration in a Gz direction are due to the effect on the systemic circulation rather than to the effect on the lungs.

Arieli, R.↗

Cardiovascular results from a rhesus monkey flown aboard the Cosmos 1514 spaceflight

The results of the Cosmos 1514 cardiovascular experiment, in which the blood flow to the head and the carotid pressure of a rhesus monkey were measured during the 5-d spaceflight, are reported. A single cylindrical probe containing both pressure and flow transducers was chronically implanted as a cuff around the left common carotid artery; measurements were obtained for 4 min every 2 h and compared to identical recordings obtained during a preflight control period and during 12 h on a launch pad. Immediately on its insertion into orbit, mean arterial pressure increased by 10 percent and has maintained a 16-27 percent increase over the first few hours of flight before returning to baseline level. Blood flow showed reciprocal changes to pressure on orbital insertion. Cardiovascular system changes persisted into the second day of flight, with the signs of adaptation appearing on days 3-5.

Sandler, H.↗

Implanted Blood-Pressure-Measuring Device

Arterial pressure compared with ambient bodily-fluid pressure. Implanted apparatus, capable of measuring blood pressure of patient, includes differential-pressure transducer connected to pressure sensor positioned in major artery. Electrical signal is function of differential pressure between blood-pressure sensor and reference-pressure sensor transmitted through skin of patient to recorder or indicator.

Fischell, Robert E.↗

Measuring Time-Averaged Blood Pressure

Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.

Rothman, Neil S.↗

Earth benefits from space life sciences

The applications to medicine of various results from space exploration are examined. Improvements have been made in the management of cardiovascular disease, in particular the use of the ultrasonic scanner to image arteries in three dimensions, the use of excimer lasers to disrupt arterial plaques in coronary blood vessels, and the use of advanced electrodes for cardiac monitoring. A bone stiffness analyzer has helped to diagnose osteoporosis and aid in its treatment. An automated light microscope system is used for chromosome analysis, and an X-ray image intensifier called Lixiscope is used in emergency medical care. An advanced portable defibrillator has been developed for the heart, and an insulin delivery system has been derived from space microminiaturization techniques.

Garshnek, V.↗

Vascular pressures and passage of gas emboli through the pulmonary circulation

Doppler technique was used to measure the pulmonary vascular pressure gradients in dogs that received venous air emboli (VAE) at the rate of 0.35 ml/kg per min, at which the spillover of bubbles into the systemic arteries occur. It was found that, in 60 percent of dogs, venous bubbles spilled over into the arterial circulation at the pulmonary vascular pressure gradient of about 34.7 mm Hg. When the pulmonary vascular pressure gradient was raised to about 52 mm Hg, the spillover of venous bubbles occurred 100 percent of time. It is concluded that venous bubbles can cross the lungs of anesthetized dogs when the driving pressures are sufficient to overcome the normal filtering function.

Butler, B. D.↗

Factor analytic reduction of the carotid-cardiac baroreflex parameters

An accepted method for measuring the responsiveness of the carotid-cardiac baroreflex to arterial pressure changes is to artificially stimulate the baroreceptors in the neck. This is accomplished by using a pressurized neck cuff which constricts and distends the carotid artery and subsequently stimulates the baroreceptors. Nine physiological responses to this type of stimulation are quantified and used as indicators of the baroreflex. Thirty male humans between the ages 27 and 46 underwent the carotid-cardiac baroreflex test. The data for the nine response parameters were analyzed by principle component factor analysis. The results of this analysis indicated that 93 percent of the total variance across all nine parameters could be explained in four dimensions. Examination of the factor loadings following an orthogonal rotation of the principle components indicated four well defined dimensions. The first two dimensions reflected location points for R-R interval and carotid distending pressure respectively. The third dimension was composed of measures reflecting the gain of the reflex. The fourth dimension was the ratio of the resting R-R interval to R-R interval during simulated hypertension. The data suggests that the analysis of all nine baroreflex parameters is redundant.

Ludwig, David A.↗

Elevated central venous pressure: A consequence of exercise training-induced hypervolemia

Resting plasma volumes, and arterial and central venous pressures (CVP) were measured in 16 men before and after exercise training to determine if training-induced hypervolemia could be explained by a change in total vascular capacitance. In addition, resting levels of plasma vasopressin (AVP), atrial natriuretic peptide (ANP), aldosterone (ALD), and norepinephrine (NE) were measured before and after training. The same measurements of vacular volume, pressures, and plasma hormones were measured in 8 subjects who did not undergo exercise and acted as controls. The exercise training program consisted of 10 weeks of controlled cycle exercise for 30 min/d, 4 d/wk at 75 to 80 percent of maximal oxygen uptake (VO2max). A training effect was verified by a 20 percent increase in VO2max, a resting bradycardia, and a 370 ml (9 percent) increase in blood volume. Mean arterial blood pressure was unaltered by exercise training, but resting CVP increased. The percent change in blood volume from before to after training was linearly related to the percent change in CVP. As a consequence of elevations in both blood volume and CVP, the volume-to-pressure ratio was essentially unchanged following exercise training. Plasma AVP, ANP, ALD, and NE were unaltered. Results indicate that elevated CVP is a consequence of training-induced hypervolemia without alteration in total effective venous capacitance. This may represent a resetting of the pressure-volume stimulus-response relation for regulation of blood volume.

Convertino, Victor A.↗

Effects of acute hypoxia on cardiopulmonary responses to head-down tilt

Six male subjects were exposed on two separate occasions to simulated microgravity with 28 deg head-down tilt (HD) for 1 h with baseline followed by recovery at + 17 deg head-up. Pulmonary ventilation, gas exchange, spirometry, and central and cerebral blood flow characteristics were compared while breathing ambient air and reduced F(I)O2 equivalent to 14,828 ft. With hypoxia (HY), the increased tidal volume served to attenuate the drop in arterial saturation by reducing deadspace ventilation. Arterial and mixed venous PO2, values, estimated from peripheral venous samples and cardiac output (CO), were both maintained during HD in HY. Mixed venous PO2 was elevated by an increase in CO associated with a reduction in systemic resistance. Changes in spirometric indices during HD were not accentuated by HY, making the presence of interstitial edema unlikely. Cerebral flow and resistance showed minor reductions with HD. Tissue oxygenation and cardiopulmonary function were not notably effected by HD during HY, but a combination of these two stressors may predispose subjects to subsequent orthostatic intolerance during initial recovery.

Loeppky, J. A.↗