Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APERTURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,549 records · Page 86

Push Type Fastener

A push type fastener for fastening a movable structural part to a fixed structural part, wherein the coupling and decoupling actions are both a push type operation, the fastener consisting of a plunger having a shank with a plunger head at one end and a threaded end portion at the other end, an expandable grommet adapted to receive the plunger shank there through, and an attachable head which is securable to the threaded end of the plunger shank. The fastener requires each structural part to be provided with an aperture and the attachable head to be smaller than the aperture in the second structural part. The plunger is extensible through the grommet and is structurally configured with an external camming surface which is cooperatively engageable with internal surfaces of the grommet so that when the plunger is inserted in the grommet, the relative positioning of said cooperable camming surfaces determines the expansion of the grommet. Coupling of the parts is effected when the grommet is inserted in the aperture in the fixed structural part and expanded by pushing the plunger head and plunger at least a minimal distance through the grommet. Decoupling is effected by pushing the attachable head.

Jackson, Steven A.↗

Ultrasonic Nondestructive Evaluation Techniques Applied to the Quantitative Characterization of Textile Composite Materials

An overall goal of this research has been to enhance our understanding of the scientific principles necessary to develop advanced ultrasonic nondestructive techniques for the quantitative characterization of advanced composite structures. To this end, we have investigated a thin woven composite (5-harness biaxial weave). We have studied the effects that variations of the physical parameters of the experimental setup can have on the ultrasonic determination of the material properties for this thin composite. In particular, we have considered the variation of the nominal center frequency and the f-number of the transmitting transducer which in turn address issues such as focusing and beam spread of ultrasonic fields. This study has employed a planar, two-dimensional, receiving pseudo-array that has permitted investigation of the diffraction patterns of ultrasonic fields. Distortion of the ultrasonic field due to the spatial anisotropy of the thin composite has prompted investigation of the phenomenon of phase cancellation at the face of a finite-aperture, piezoelectric receiver. We have performed phase-sensitive and phase-insensitive analyses to provide a measure of the amount of phase cancellation at the face of a finite-aperture, piezoelectric receiver. The pursuit of robust measurements of received energy (i.e., those not susceptible to phase cancellation at the face of a finite-aperture, piezoelectric receiver) supports the development of robust techniques to determine material properties from measure ultrasonic parameters.

Miller, James G.↗

Z-Scan Measurement of the Nonlinear Absorption of a Thin Gold Film

We have used the z-scan technique at a wavelength (532 nm) near the transmission window of bulk gold to measure the nonlinear absorption coefficient of continuous approximately 50-Angstrom-thick gold films, deposited onto surface-modified quartz substrates. For highly absorbing media such as metals, we demonstrate that determination of either the real or imaginary part of the third-order susceptibility requires a measurement of both nonlinear absorption and nonlinear refraction, i.e. both open- and closed-aperture z-scans must be performed. Closed-aperture z-scans did not yield a sufficient signal for the determination of the nonlinear refraction. However, open-aperture z-scans yielded values ranging from Beta = 1.9 x 10(exp -3) to 5.3 x 10(exp -3) cm/W in good agreement with predictions which ascribe the nonlinear response to a Fermi smearing mechanism. We note that the sign of the nonlinearity is reversed from that of gold nanoparticle composites, in accordance with the predictions of mean field theories.

Smith, David D.↗

High-Efficiency Autonomous Coherent Lidar

A useful measure of sensor performance is the transceiver system efficiency n (sub sys). Which consists of the antenna efficiency n (sub a) and optical and electronic losses. Typically, the lidar equation and the antenna efficiency are defined in terms of the telescope aperture area. However, during the assembly of a coherent transceiver, it is important to measure the system efficiency before the installation of the beamexpanding telescope (i.e., the untruncated-beam system efficiency). Therefore, to accommodate both truncated and untruncated beam efficiency measurements, we define the lidar equation and the antenna efficiency in terms of the beam area rather than the commonly used aperture area referenced definition. With a well-designed Gaussian-beam lidar, aperture area referenced system efficiencies of 15 to 20 % (23-31% relative to the beam area) are readily achievable. In this paper we compare the differences between these efficiency definitions. We then describe techniques by which high efficiency can be achieved, followed by a discussion several novel auto alignment techniques developed to maintain high efficiency.

Philip Gatt↗

Landsat-7 EMT+ On-Orbit Radiometric Calibration

Landsat-7 was launched on April 15, 1999 and completed its on orbit initialization and verification period on June 28, 1999. The ETM+ payload is similar to the TM sensors on previous Landsat satellites and incorporates two new devices to improve its absolute radiometric calibration. The Full Aperture Solar Calibrator (FASC) is a deployable diffuser panel. This device has been deployed 9 times to date, with a normal deployment schedule of once per month. The initial analysis of the FASC data has given absolute calibration results within 5% of the prelaunch integrating sphere calibrations and a range of variation of 2% between dates. The Partial Aperture Solar Calibrator (PASC), is a set of auxiliary optics that allows the ETM+ to view the sun through a reduced aperture. Data have normally been acquired on a daily basis with the PASC. Initial results with the PASC were encouraging, despite some unexpected saturation in the shortest wavelength band. The response of the ETM+ short wavelength (silicon) bands to the PASC increased initially and has begun to decrease in some of these bands. The longer wavelength (InSb) bands have shown up to 30% oscillations that vary between detectors within the band. Studies are ongoing to better characterize the response to the PASC. The ETM+ also incorporates an internal calibrator (IC), a shutter that oscillates in front of the focal plane that directs light from the internal calibrator lamps to the focal plane. The responses to this device are also varying, though differently than the PASC results. Both the IC and PASC results are attributable to the calibration devices as opposed to the ETM+ itself.

Markham, Brian L.↗

A Tethered Formation Flying Concept for the SPECS Mission

The Sub-millimeter Probe of the Evolution of Cosmic Structure (SPECS) is a bold new mission concept designed to address fundamental questions about the Universe, including how the first stars formed from primordial material, and the first galaxies from pre-galactic structures, how the galaxies evolve over time, and what the cosmic history of energy release, heavy element synthesis, and dust formation is. Half of the luminosity and 98% of the post Big-Bang photons exit in the sub-millimeter range. The spectrum of our own Milky Way Galaxy shows this, and many galaxies have even more pronounced long-wavelength emissions. There can be no doubt that revolutionary science will be enabled when we have tools to study the sub-millimeter sky with Hubble- Space-Telescope-class resolution and sensitivity. Ideally, a very large telescope with an effective aperture approaching one kilometer in diameter would be needed to obtain such high quality angular resolution at these long wavelengths. However, a single aperture one kilometer in diameter would not only be very difficult to build and maintain at the cryogenic temperatures required for good seeing, but could actually turn out to be serious overkill. Because cosmic sub-millimeter photons are plentiful and the new detectors will be sensitive, the observations needed to address the questions posed above can be made with an interferometer using well established aperture synthesis techniques. Possibly as few as three 3-4 meter diameter mirrors flying in precision formation could be used to collect the light. To mitigate the need for a great deal of propellant, tethers may be needed as well. A spin-stabilized, tethered formation is a possible configuration requiring a more advanced form of formation flying controller, where dynamics are coupled due to the existence of the tethers between nodes in the formation network. The paper presents one such concept, a proposed configuration for a mission concept which combines the best features of structure, tethers and formation flying to meet the ambitious requirements necessary to make a future SPECS mission a success.

Quinn, David A.↗

Potential Challenges in Near-Field Scanning Optical Microscopy for Space Applications

Near-field scanning optical microscopy (NSOM) also called scanning near-field optical microscopy (SNOM) is now well accepted as a powerful tool for sub-wavelength (nanoscale in the optical region) spatial resolution microscopy and a large number of related tasks. The importance lies in the fact of strategic advantages of standard microscopy but with significantly enhanced resolution. Since many modern optical diagnostic techniques have found useful applications in space, it is logical to consider the future role of NSOM in such situations. For example, protein crystal growth study under microgravity conditions is a valid candidate. If applied successfully, processes at molecular level can be studied during the growth. NSOM has already been demonstrated to be useful for the study of such crystals here on earth. The basic principle of NSOM can be illustrated. The illumination-collection mode is shown although several other possible approaches exist. In this, the sample is illuminated and the light from the sample is collected through the same tiny aperture opening. A tapered optical fiber is scanned near the sample surface. The tip is coated generally with a metal with a sub-wavelength aperture opening. The tip-sample distance is maintained constant while scanning. Thus, the optical signal available for collection is generally a function of the optical properties of the sample surface. Since the aperture is sub-wavelength in diameter and the tip is held very close (again in the sub-wavelength domain) to the surface, the lateral resolution in the sub-wavelength domain is obtained. Thus, the typical wavelength- order resolution of ordinary microscopy can be significantly enhanced while maintaining the strategic advantages (no need of sample in vacuum chamber, electron beams, etc). Commercial NSOM systems play a key role in the success and widespread acceptance of the tool. These commercial systems work fairly well in laboratory conditions on earth. However, they may not be deployed on a space mission as such with comparable outcome. In this communication we discuss several potential problems and some possible solutions.

Vikram, Chandra S.↗

Dependence of the Element Patterns of HYDROSTAR on Mutual Coupling

HYDROSTAR is a hybrid synthesis radiometer, intended for spaceborne applications, which employs a real aperture (waveguide stick antenna) for resolution along track and employs aperture synthesis to obtain resolution across track. This L-band system is an extension of the successful aircraft prototype, the Electronically Steered Thinned Array Radiometer (ESTAR). A proof-of-concept, full size system was constructed (45 wavelength in the synthesis direction) and subjected to extensive antenna pattern and associated microwave component measurements in an outdoor antenna test facility. HYDROSTAR employs a thinned array of 16 elements each 5.8 inches long in the along track dimension and spanning 9.5 inches across track. Each element is a narrow-wall shunt slot array with 36 slots. The polarization is linear (along-track). In the across track dimension, the antennas are deployed in a minimum redundancy array which has 90 independent baselines spaced in integer multiples of half a wavelength. The closest spacings used are for the first three elements at each end, which are spaced by only one-half wavelength. This study was intended to assess how closely each of 16 stick element patterns compare with their nominal values (as an individual, isolated radiator), when installed in their intended composite thinned array configuration. Extensive pattern measurements of the 16 elements that constitute the HYDROSTAR antenna subsystem were conducted to observe their relative features along the synthesis plane. Data was also collected for the mutual coupling between pairs of selected antennas. All antenna patterns had features different from that of an isolated element indicating some level of interaction among neighboring radiators. Those elements which had nearest neighbors at least five wavelengths away were located near the middle of the array. Their radiation patterns displayed sonic small, symmetric ripple across their full azimuth range. The patterns of elements that lie within 2.5 wavelengths of their neighbors showed stronger and asymmetric features. These are believed to be caused by mutual coupling among these structures. Evidence for this was seen when an antenna position was displaced by 0.05 wavelengths, Its pattern and those of its near neighbors were seen to change. Displacement within the plane of the array were observed to have different effects than displacements out-of-plane. A program of data analysis and theoretical development is in progress to provide a physical interpretation of the properties of these antenna patterns and to develop methods which can optimize the performance of this synthetic aperture imaging system. This includes compensation for pattern asymmetries and element position perturbation.

Weissman, David E.↗

The Future of Instrument Technology for Space-based Remote Sensing

The current paradigm for space-based remote sensing relies upon frequency-specific measurements in pre-defined orbits with fixed or narrowly variable apertures. The suites of Earth observing instruments currently deployed or planned for deployment within the next 3 years typify this paradigm. To enable NASA's Earth Science vision, the future paradigm of remote sensing must employ frequency-agile measurements capable of multi-scene observations. Real-time, autonomous adaptive sensing and taskability will be critical. Advanced capabilities will include: (1) Miniaturized observatories. (2) Robust, compact instrument architectures. (3) Miniaturized/programmable components. (4) Aperture synthesis. (5) Deployable apertures. (6) Low cost production.

Peri, Frank↗

Evaluation of Aircraft Platforms for SOFIA by Computational Fluid Dynamics

The selection of an airborne platform for the Stratospheric Observatory for Infrared Astronomy (SOFIA) is based not only on economic cost, but technical criteria, as well. Technical issues include aircraft fatigue, resonant characteristics of the cavity-port shear layer, aircraft stability, the drag penalty of the open telescope bay, and telescope performance. Recently, two versions of the Boeing 747 aircraft, viz., the -SP and -200 configurations, were evaluated by computational fluid dynamics (CFD) for their suitability as SOFIA platforms. In each configuration the telescope was mounted behind the wings in an open bay with nearly circular aperture. The geometry of the cavity, cavity aperture, and telescope was identical in both platforms. The aperture was located on the port side of the aircraft and the elevation angle of the telescope, measured with respect to the vertical axis, was 500. The unsteady, viscous, three-dimensional, aerodynamic and acoustic flow fields in the vicinity of SOFIA were simulated by an implicit, finite-difference Navier-Stokes flow solver (OVERFLOW) on a Chimera, overset grid system. The computational domain was discretized by structured grids. Computations were performed at wind-tunnel and flight Reynolds numbers corresponding to one free-stream flow condition (M = 0.85, angle of attack alpha = 2.50, and sideslip angle beta = 0 degrees). The computational domains consisted of twenty-nine(29) overset grids in the wind-tunnel simulations and forty-five(45) grids in the simulations run at cruise flight conditions. The maximum number of grid points in the simulations was approximately 4 x 10(exp 6). Issues considered in the evaluation study included analysis of the unsteady flow field in the cavity, the influence of the cavity on the flow across empennage surfaces, the drag penalty caused by the open telescope bay, and the noise radiating from cavity surfaces and the cavity-port shear layer. Wind-tunnel data were also available to compare to the CFD results; the data permitted an assessment of CFD as a design tool for the SOFIA program.

Klotz, S. P.↗

Spatial and Spatial Frequency Spreads of Masking: Measurements and A Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2, 4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 z 0 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, Joshua A.↗

Smooth Pursuit of a Partially Occluded Object

There has long been qualitative evidence that humans can pursue an object defined only by the motion of its parts. We explored this quantitatively using an occluded diamond stimulus. Four subjects (one naive) tracked a line-figure diamond moving along an elliptical path (0.9 Hz) either clockwise (CW) or counterclockwise (CCW) behind either an X-shaped aperture (CROSS) or two vertical rectangular apertures (BARS), which obscured the corners. Although the stimulus consisted of only four line segments (108 cd/square m) moving within a visible aperture (0.2 cd/square m) behind a foreground (38 cd/square m), it is largely perceived as a coherently moving diamond. The inter-saccadic portions of eye-position traces were fit with sinusoids. All subjects tracked object motion with considerable temporal accuracy. The mean phase lag was 5 deg/6 deg (CROSS/BARS) and the mean relative phase between the horizontal and vertical components was +95 deg/+92 deg (CW) and -85 deg/-75 deg (CCW), which is close to perfect. Furthermore, a chi-square analysis showed that 56% of BARS trials were consistent with tracking the correct elliptical shape (p is less than 0.05), although segment motion was purely vertical. These data disprove the main tenet of most models of pursuit: that it is a system that seeks to minimize retinal image motion through negative feedback. Rather, the main drive must be a visual signal which has already integrated spatiotemporal retinal information into an object-motion signal.

Stone, L. S.↗

Spatial and Spatial Frequency Spreads Of Masking: Measurements and a Contrast-Gain-Control Model

Masked pattern detection is affected by the mask's proximity to the target in both the spatial and the spatial frequency domains. We measured contrast thresholds for detection of a Gabor patch centered in a sample of static band-pass noise with a central noise-free aperture. To examine spatial spread, target and mask frequency were identical, at either 2, 4, or 8 cycles/degree (cpd), and the radius of the aperture was 0, 1/2 or 1 cycle of the noise band's center frequency. The results suggest that the spatial spread of masking is scale invariant, with the largest radius producing little masking. To examine spatial frequency spread, a radius of 0 (no aperture) was used with all pairings of 2,4, and 8 cpd for target and mask. The results suggest that masking is asymmetrical over log frequency: 8 cpd noise masks a 2 cpd target, but 2 cpd noise does not mask an 8 cpd target. We have used these results to calibrate a model of contrast-gain-control.

Solomon, J. A.↗

Compositionally-Graded Shape Memory Film for Self-Deployment of Membrane Reflectors and Optics

The next generation of space systems will require large apertures in order to image faint targets or cover large areas of Earth. These large apertures must be able to fit inside a launch vehicle fairing, be light enough for launch into orbit, and deploy on orbit with repeatability and reliability. The current state-of-the-art in flight optics is represented by the 4 meter LAMP telescope, with an areal density of 10 km sq m. Development of a Beryllium mirror demonstration article for NGST (Next Generation Space Telescope) at the University of Arizona indicate areal densities of 0.5 kg sq m with flight hardware in the 12 meter range. With progressive improvements in existing deployment, packaging, and structural technologies, the size of optics and reflectors will continue to increase, while mass is reduced. However, without a breakthrough in materials, packaging and/or deployment technologies, the goal for Gossamer structures of 0.1 kg sq m is unachievable for the near and mid-term NASA missions. Membrane technology provides the best hope of achieving such low areal densities. In combination with advances in membrane materials and structures, development of revolutionary techniques for deployment systems can provide significant improvements in large aperture technology. In this paper, the results of a six-month Phase I research effort to demonstrate the application of thin film NiTi to aerospace-qualified membrane and mesh materials are presented. Deposition of shape memory thin film was achieved Astromesh (trademark) metal mesh and CP-1, and optical-quality polymer membrane. Not only was full-coating deposition demonstrated, but also small segment deposition which holds potential for local surface control. Deployment of these materials was also demonstrated, setting the stage for the development of a larger test article.

Hill, Lisa↗

Building A New Kind of Graded-Z Shield for Swift's Burst Alert Telescope

The Burst Alert Telescope (BAT) on Swift has a graded-Z Shield that closes out the volume between the coded aperture mask and the Cadmium-Zinc-Telluride (CZT) detector array. The purpose of the 37 kilogram shield is to attenuate gamma rays that have not penetrated the coded aperture mask of the BAT instrument and are therefore a major source of noise on the detector array. Unlike previous shields made from plates and panels, this shield consists of multiple layers of thin metal foils (lead, tantalum, tin, and copper) that are stitched together much like standard multi-layer insulation blankets. The shield sections are fastened around BAT, forming a curtain around the instrument aperture. Strength tests were performed to validate and improve the design, and the shield will be vibration tested along with BAT in late 2002. Practical aspects such as the layup design, methods of manufacture, and testing of this new kind of graded-Z Shield are presented.

Robinson, David W.↗

The STIS CCD Spectroscopic Line Spread Functions

We characterize the spectroscopic line spread functions of the spectroscopic CCD modes for high contrast objects. Our long range goal is to develop tools that accurately extract spectroscopic information of faint, point or extended sources in the vicinity of bright, point sources at separations approaching the realizable angular limits of HST with STIS. Diffracted and scattered light due to the HST optics, and scattered light effects within the STIS are addressed. Filter fringing, CCD fringing, window reflections, and scattering within the detector and other effects are noted. We have obtained spectra of several reference stars, used for flux calibration or for coronagraphic standards, that have spectral distributions ranging from very red to very blue. Spectra of each star were recorded with the star in the aperture and with the star blocked by either the F1 or F2 fiducial. Plots of the detected starlight along the spatial axis of the aperture are provided for four stars. With the star in the aperture, the line spread function is quite noticeable. Placing the star behind one of the fiducials cuts the scattered light and the diffracted light, is detectable even out to 1OOOOA. When the star is placed behind either fiducial, the scattered and diffracted light components, at three arcseconds displacement from the star, are below lop6 the peak of the star at wavelengths below 6000A; at the same angular distance, scattered light does contaminate the background longward of 6000A up to a level of 10(exp -5).

Gull, T.↗

The Case for Space-Borne Far-Infrared Line Surveys

The combination of sensitive direct detectors and a cooled aperture promises orders of magnitude improvement in the sensitivity and survey time for far-infrared and submillimeter spectroscopy compared to existing or planned capabilities. Continuing advances in direct detector technology enable spectroscopy that approaches the background limit available only from space at these wavelengths. Because the spectral confusion limit is significantly lower than the more familiar spatial confusion limit encountered in imaging applications, spectroscopy can be carried out to comparable depth with a significantly smaller aperture. We are developing a novel waveguide-coupled grating spectrometer that disperses radiation into a wide instantaneous bandwidth with moderate resolution (R ~ 1000) in a compact 2-dimensional format. A line survey instrument coupled to a modest cooled single aperture provides an attractive scientific application for spectroscopy with direct detectors. Using a suite of waveguide spectrometers, we can obtain complete coverage over the entire far-infrared and sub-millimeter. This concept requires no moving parts to modulate the optical signal. Such an instrument would be able to conduct a far-infrared line survey 10 6 times faster than planned capabilities, assuming existing detector technology. However, if historical improvements in bolometer sensitivity continue, so that photon-limited sensitivity is obtained, the integration time can be further reduced by 2 to 4 orders of magnitude, depending on wavelength. The line flux sensitivity would be comparable to ALMA, but at shorter wavelengths and with the continuous coverage needed to extract line fluxes for sources at unknown redshifts. For example, this capability would break the current spectroscopic bottleneck in the study of far-infrared galaxies, the recently discovered, rapidly evolving objects abundant at cosmological distances.

Bock, J. J.↗

Heading perception in patients with advanced retinitis pigmentosa

PURPOSE: We investigated whether retinis pigmentosa (RP) patients with residual visual field of < 100 degrees could perceive heading from optic flow. METHODS: Four RP patients and four age-matched normally sighted control subjects viewed displays simulating an observer walking over a ground. In experiment 1, subjects viewed either the entire display with free fixation (full-field condition) or through an aperture with a fixation point at the center (aperture condition). In experiment 2, patients viewed displays of different durations. RESULTS: RP patients' performance was comparable to that of the age-matched control subjects: heading judgment was better in the full-field condition than in the aperture condition. Increasing display duration from 0.5 s to 1 s improved patients' heading performance, but giving them more time (3 s) to gather more visual information did not consistently further improve their performance. CONCLUSIONS: RP patients use active scanning eye movements to compensate for their visual field loss in heading perception; they might be able to gather sufficient optic flow information for heading perception in about 1 s.

Visual Perception↗