Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Delaying Trains of Short Light Pulses in WGM Resonators

Suitably configured whispering-gallery-mode (WGM) optical resonators have been proposed as delay lines for trains of short light pulses. Until now, it has been common practice to implement an optical delay line as a coiled long optical fiber, which is bulky and tends to be noisy. An alternative has been to implement an optical delay line as a coupled-resonator optical waveguide (a chain of coupled optical resonators), which is compact but limits the width of the pulse spectrum to the width of an optical resonance and thereby places a lower limit on the duration of a pulse. In contrast, a delay line according to the proposal could be implemented as a single WGM resonator, and the pulses delayed by the resonator could be so short that their spectral widths could greatly exceed the spectral width of any single resonance. The proposal emerged from theoretical and experimental studies of the propagation of a pulse train in a WGM resonator. An important element of the theoretical study was recognition that the traditional definition of group velocity in effect, the velocity of a single pulse comprising a packet of waves propagating in a medium, the responsivity of which is a monotonous function of frequency does not necessarily apply in the case of a WGM resonator or other medium having a spectrum consisting of discrete resonance peaks at different frequencies. A new definition of group velocity, applicable to a train of pulses propagating in such a medium, was introduced and found to lead to the discovery of previously unknown features of propagation. Notably, it was found that in a micro - sphere optical resonator that supports a suitable combination of WGM modes, the group velocity for a train of light pulses could be positive, zero, or negative. A positive group velocity could be so small that the delay could be much longer than the ring-down time of the resonator; a delay of such great length is impossible for a single pulse interacting with either a linearly responding lossless resonator or a coupled- resonator optical waveguide.

Matsko, Andrey↗

Coastal Research Imaging Spectrometer

The Coastal Research Imaging Spectrometer (CRIS) is an airborne remote sensing system designed specifically for research on the physical, chemical, and biological characteristics of coastal waters. The CRIS includes a visible-light hyperspectral imaging subsystem for measuring the color of water, which contains information on the biota, sediment, and nutrient contents of the water. The CRIS also includes an infrared imaging subsystem, which provides information on the temperature of the water. The combination of measurements enables investigation of biological effects of both natural and artificial flows of water from land into the ocean, including diffuse and point-source flows that may contain biological and/or chemical pollutants. Temperature is an important element of such measurements because temperature contrasts can often be used to distinguish among flows from different sources: for example, a sewage outflow could manifest itself in spectral images as a local high-temperature anomaly. Both the visible and infrared subsystems scan in pushbroom mode: that is, an aircraft carrying the system moves along a ground track, the system is aimed downward, and image data are acquired in across-track linear arrays of pixels. Both subsystems operate at a frame rate of 30 Hz. The infrared and visible-light optics are adjusted so that both subsystems are aimed at the same moving swath, which has across-track angular width of 15 . Data from the infrared and visible imaging subsystems are stored in the same file along with aircraft- position data acquired by a Global Positioning System receiver. The combination of the three sets of data is used to construct infrared and hyperspectral maps of scanned areas (see figure). The visible subsystem is based on a grating spectrograph and a rapid-readout charge-coupled-device camera. Images of the swatch are acquired in 256 spectral bands at wavelengths from 400 to 800 nm. The infrared subsystem, which is sensitive in a single wavelength band of 8 to 10 m, is based on a focal-plane array of HgCdTe photodetectors that are cooled to an operating temperature of 77 K by use of a closed-Stirling-cycle mechanical cooler. The nonuniformities of the HgCdTe photodetector array are small enough that the raw pixel data from the infrared subsystem can be used to recognize temperature differences on the order of 1 C. By use of a built-in blackbody calibration source that can be switched into the field of view, one can obtain bias and gain offset terms for individual pixels, making it possible to offset the effects of nonuniformities sufficiently to enable the measurement of temperature differences as small as 0.1 C.

Lucey, Paul G.↗

Effect of DM Actuator Errors on the WFIRST/AFTA Coronagraph Contrast Performance

The WFIRST/AFTA 2.4 m space telescope currently under study includes a stellar coronagraph for the imaging and the spectral characterization of extrasolar planets. The coronagraph employs two sequential deformable mirrors (DMs) to compensate for phase and amplitude errors in creating dark holes. DMs are critical elements in high contrast coronagraphs, requiring precision and stability measured in picometers to enable detection of Earth-like exoplanets. Working with a low-order wavefront-sensor the DM that is conjugate to a pupil can also be used to correct low-order wavefront drift during a scientific observation. However, not all actuators in a DM have the same gain. When using such a DM in low-order wavefront sensing and control subsystem, the actuator gain errors introduce high-spatial frequency errors to the DM surface and thus worsen the contrast performance of the coronagraph. We have investigated the effects of actuator gain errors and the actuator command digitization errors on the contrast performance of the coronagraph through modeling and simulations, and will present our results in this paper.

adaptive optics↗

Radioactive sample effects on EDXRF spectra

Energy dispersive X-ray fluorescence (EDXRF) is a rapid, straightforward method to determine sample elemental composition. A spectrum can be collected in a few minutes or less, and elemental content can be determined easily if there is adequate energy resolution. Radioactive alpha emitters, however, emit X-rays during the alpha decay process that complicate spectral interpretation. This is particularly noticeable when using a portable instrument where the detector is located in close proximity to the instrument analysis window held against the sample. A portable EDXRF instrument was used to collect spectra from specimens containing plutonium-239 (a moderate alpha emitter) and americium-241 (a heavy alpha emitter). These specimens were then analyzed with a wavelength dispersive XRF (WDXRF) instrument to demonstrate the differences to which sample radiation-induced X-ray emission affects the detectors on these two types of XRF instruments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Global tropospheric and total ozone monitoring with a Double-Etalon Fabry-Perot interferometer

Knowledge of the global scale distribution of atmospheric ozone and its temporal variability can be achieved using a satellite-based nadir-viewing device making high spectral resolution measurements with high signal-to-noise ratios. This would enable observation in the pressure-broadened wings of strong O3 lines while minimizing the impact of undesirable signal contributions associated with, for example, the terrestrial surface and interfering species. The Fabry-Perot interferometer (FPI) provides high spectral resolution and high throughput capabilities that are essential for this measurement task. The periodic nature of the Fabry-Perot instrument function can be advantageous when observation of periodic spectra is desired. However, for most applications, additional optical elements are necessary to reduce the effect of unwanted passbands. This is frequently accomplished using additional Fabry-Perot etalons in a series configuration in conjunction with a bandpass filter. This paper discusses a Fabry-Perot interferometer conceptual instrument design to achieve tropospheric and total ozone monitoring capability from a satellite-based nadir-viewing geometry. The design involves a double-etalon fixed-gap series configuration FPI along with an ultra-narrow bandpass filter to achieve single-order operation with an overall spectral resolution of approximately .068 cm(exp -1). The impact of inter-etalon reflections has been reduced to acceptable levels by placement of a slightly attenuating medium in between the etalons. A passive device is selected for low power consumption, and continuous day/night coverage, independent of solar zenith angle, is enabled by observing within the strong 9.6 micron ozone infrared band. The IR-FPI detection will be performed through implementation of the new Circle to Line Interferometer Optical (CLIO) system, developed by researchers at the Space Physics Research Laboratory (SPRL) of the University of Michigan, to accomplish focal plane fringe detection; the CLIO system converts the circular interferometric fringes into a linear pattern which then can be detected by conventional linear array detectors. A multiplex signal advantage is achievable as all necessary frequencies can be measured simultaneously using a multichannel configuration. Through proper selection of channel spectral regions, the FPI optimized for tropospheric O3 measurements can simultaneously observe a stratospheric component and thus the total O3 column abundance.

Larar, Allen M.↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Spectral analysis of x-ray emission created by intense laser irradiation of copper materials

We have measured the x-ray emission, primarily from K{sub {alpha}},K{sub {beta}}, and He{sub {alpha}} lines, of elemental copper foil and 'foam' targets irradiated with a mid-10{sup 16} W/cm{sup 2} laser pulse. The copper foam at 0.1 times solid density is observed to produce 50% greater He{sub {alpha}} line emission than copper foil, and the measured signal is well-fit by a sum of three synthetic spectra generated by the atomic physics code FLYCHK. Additionally, spectra from both targets reveal characteristic inner shell K{sub {alpha}} transitions from hot electron interaction with the bulk copper. However, only the larger-volume foam target produced significant K{sub {beta}} radiation, confirming a lower bulk temperature in the higher volume sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ISMabs: A COMPREHENSIVE X-RAY ABSORPTION MODEL FOR THE INTERSTELLAR MEDIUM

We present an X-ray absorption model for the interstellar medium, to be referred to as ISMabs, that takes into account both neutral and ionized species of cosmically abundant elements, and includes the most accurate atomic data available. Using high-resolution spectra from eight X-ray binaries obtained with the Chandra High Energy Transmission Grating Spectrometer, we proceed to benchmark the atomic data in the model particularly in the neon K-edge region. Compared with previous photoabsorption models, which solely rely on neutral species, the inclusion of ions leads to improved spectral fits. Fit parameters comprise the column densities of abundant contributors that allow direct estimates of the ionization states. ISMabs is provided in the appropriate format to be implemented in widely used X-ray spectral fitting packages such as XSPEC, ISIS, and SHERPA.

79 ASTRONOMY AND ASTROPHYSICS↗

On the Hunt for Detectable Biosignatures in Jezero Crater: What to Look for and Where

Introduction: The Perseverance rover, which is currently exploring Jezero crater on Mars, is equipped with seven instruments that allow for observation of textures, minerals, color, structure, and chemistry of rocks and sediments in order to search for signs of ancient life, understand the geologic history of the crater, and identify candidates for sample return (Farley et al. 2020). The first of these aims includes the direct detection of potential biosignatures, including textures, organic molecules, minerals, and elemental chemistries that are of biogenic origin (Mustard et al. 2013). The presence of these biosignatures will be constrained by the habitability of the local region, the preservation potential of the host rocks, and the sensitivity of the instrument suite, and their biogenicity will be investigated after return to Earth as part of the Mars Sample Return campaign. Here, we examine key targets on the three planned campaigns, potential biosignatures that may be present, and the capabilities of key rover instruments. High Potential Biosignature Sites in Jezero: To date, measurements have been made on multiple sites that both contain minerals known in terrestrial settings to preserve biosignatures and likely were habitable settings (Williford et al. 2021). Two examples include the fine-grained rocks at the base of the delta fan and the NW inner margin of the crater. Fine-grained Rocks at Base of Delta Fan. Fine-grained, clay-bearing rocks may have been deposited as muddy lake sediments that could have hosted life and preserved biosignatures settling out of the water column. The report of organic molecules by the Curiosity rover in the Sheepbed mudstone and Murray formation has highlighted this site in particular. Potential biosignatures in mudstones, especially those rich in silica (McMahon et al. 2018), microbialites and complex organics. NW Inner Margin of Crater. This unit, located along the inner margin of the crater, contains strong carbonate signatures and may have been the littoral zone of a lake (Horgan et al. 2020). The potential biosignatures here include microfossils, microbialites, biominerals, and complex organics. Detectability of Biosignatures by the Mars 2020 Instrument Suite: The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument comprises a Deep UV spectrometer, context imager, and color camera to generate spatially resolved chemical maps (Bhartia et al. 2020). It is sensitive to trace organics as well as a range of minerals and can detect native fluorescence from aromatic organics; the WATSON and ACI cameras can be used to observe morphologies such as stromatolitic laminations or filaments ranging from the tens of micron to millimeter scale. SHERLOC can detect organics that may be present in either of the high potential biosignature targets, as well as detect carbonates in the latter. However, the presence of high amounts of iron, such as in iron-rich clays, would cause attenuation of spectral response through UV absorption. The Planetary Instrument for X-ray Lithochemistry (PIXL) comprises an X-ray fluorescence spectrometer and camera that can scan rock surfaces to generate elemental maps (Allwood et al. 2020). PIXL can detect chemical biosignatures such as spatial variations of elemental abundances that may have resulted from biological activity. PIXL would be particularly useful in detecting fine textures and elemental chemistries in either high potential biosignature target, but cannot directly detect minerals such as carbonate. The SuperCam instrument performs three types of spectroscopy, color imaging, and acoustic recording to remotely examine elemental composition, minerals, organics, and textures (Maurice et al. 2021). Using laser induced breakdown spectroscopy and time resolved luminescence spectroscopy, SuperCam can detect major elemental building blocks of organics (i.e., C, H, N, O, P, S) and conjugated organic structures, respectively, which may be found in either site. While in other contexts, luminescence is a useful tool for biosignature identification, luminescence generated by the 532 nm laser may obscure the Raman signal. Conclusion: The three instruments discussed can be used collaboratively to establish the presence of potential biosignatures in samples. These high-priority samples may then be returned to Earth for detailed laboratory analysis.

S. Sharma↗

Spectral Signatures of Ultrafast Excited-State Intramolecular Proton Transfer from Computational Multi-edge Transient X-ray Absorption Spectroscopy

Excited state intramolecular proton transfer (ESIPT) is a fundamental chemical process with several applications. Ultrafast ESIPT involves coupled electronic and atomic motions and has been primarily studied using femtosecond optical spectroscopy. X-ray spectroscopy is particularly useful because it is element-specic and enables direct, individual probes of the proton donating and accepting atoms. Here, we report a computational study to resolve the ESIPT in 10-Hydroxybenzo[h]quinoline (HBQ), an intramolecularly hydrogen bonded compound, using time-dependent density functional theory combined with ab initio molecular dynamics (AIMD) and time-resolved X-ray absorption spectroscopy (XAS) computations to track the ultrafast excited-state dynamics. Overall, our results reveal clear X-ray spectral signatures of coupled electronic and atomic motions during and following ESIPT at the oxygen and nitrogen K-edge paving the way for future experiments at X-ray free electron lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic determination of uranium in soil by laser induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) operated under ambient pressure has been evaluated for isotopic analysis of uranium in real-world samples such as soil, with U concentrations in the single digit percentage levels. The study addresses the requirements for spectral decomposition of 235 U and 238 U atomic emission peaks that are only partially resolved. Although non-linear least-square fitting algorithms are typically able to locate the optimal combination of fitting parameters that best describes the experimental spectrum even when all fitting parameters are treated as free independent variables, the analytical results of such an unconstrained free-parameter approach are ambiguous. In this work, five spectral decomposition algorithms were examined, with different known physical properties (e.g., isotopic splitting, hyperfine structure) of the spectral lines sequentially incorporated into the candidate algorithms as constraints. It was found that incorporation of such spectral-line constraints into the decomposition algorithm is essential for the best isotopic analysis. The isotopic abundance of 235 U was determined from a simple two-component Lorentzian fit on the U II 424.437 nm spectral profile. For six replicate measurements, each with only fifteen laser shots, on a soil sample with U concentration at 1.1% w/w, the determined 235 U isotopic abundance was (64.6 ± 4.8)%, and agreed well with the certified value of 64.4%. Another studied U line - U I 682.691 nm possesses hyperfine structure that is comparatively broad and at a significant fraction as the isotopic shift. Thus, 235 U isotopic analysis with this U I line was performed with spectral decomposition involving individual hyperfine components. For the soil sample with 1.1% w/w U, the determined 235 U isotopic abundance was (60.9 ± 2.0)%, which exhibited a relative bias about 6% from the certified value. The bias was attributed to the spectral resolution of our measurement system - the measured line width for this U I line was larger than its isotopic splitting. In conclusion, although not the best emission line for isotopic analysis, this U I emission line is sensitive for element analysis with a detection limit of 500 ppm U in the soil matrix; the detection limit for the U II 424.437 nm line was 2000 ppm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extreme ultraviolet spectroscopy diagnostics of low-temperature plasmas based on a sliced multilayer grating and glass capillary optics

New extreme ultraviolet (EUV) spectroscopic diagnostics of relatively low-temperature plasmas based on the application of an EUV spectrometer and fast EUV diodes combined with glass capillary optics is described. An advanced high resolution dispersive element sliced multilayer grating was used in the compact EUV spectrometer. For monitoring of the time history of radiation, filtered fast EUV diodes were used in the same spectral region (>13 nm) as the EUV spectrometer. The radiation from the plasma was captured by using a single inexpensive glass capillary that was transported onto the spectrometer entrance slit and EUV diode. The use of glass capillary optics allowed placement of the spectrometer and diodes behind the thick radiation shield outside the direction of a possible hard x-ray radiation beam and debris from the plasma source. The results of the testing and application of this diagnostic for a compact laser plasma source are presented. Examples of modeling with parameters of plasmas are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum metrology to probe atomic parity nonconservation

An entangled state prepared in a decoherence-free subspace, together with a Ramsey-type measurement, can probe parity violation in heavy alkali-metal ions such as Ba{sup +} or Ra{sup +}. Here we propose an experiment with Ba{sup +} as an example to measure the small parity-violating effect in this system. It has been shown that a measurement on a maximally correlated system will reduce the uncertainty as compared to that on a single ion measurement, and also provides a feasible solution to measure the nuclear-spin-dependent part of the total parity-violating light shift in an ionic system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Layer-resolved ultrafast extreme ultraviolet measurement of hole transport in a Ni-TiO 2 -Si photoanode

Metal oxide semiconductor junctions are central to most electronic and optoelectronic devices, but ultrafast measurements of carrier transport have been limited to device-average measurements. Here, charge transport and recombination kinetics in each layer of a Ni-TiO 2 -Si junction is measured using the element specificity of broadband extreme ultraviolet (XUV) ultrafast pulses. After silicon photoexcitation, holes are inferred to transport from Si to Ni ballistically in ~100 fs, resulting in characteristic spectral shifts in the XUV edges. Meanwhile, the electrons remain on Si. After picoseconds, the transient hole population on Ni is observed to back-diffuse through the TiO 2 , shifting the Ti spectrum to a higher oxidation state, followed by electron-hole recombination at the Si-TiO 2 interface and in the Si bulk. Electrical properties, such as the hole diffusion constant in TiO 2 and the initial hole mobility in Si, are fit from these transient spectra and match well with values reported previously.

42 ENGINEERING↗

Parameters of microwave discharge plasmas in powder mixtures

A study is made of the optical emission spectra of a plasma produced under the action of a microwave beam with a field amplitude of about 3 kV/cm on a metal-dielectric mixture at atmospheric pressure. In the initial stage of the discharge, the plasma is localized in microscale sites at the target surface, the characteristic size of the glowing regions in the target plane being less than 1 mm. In this stage, the target material is evaporated and atomic spectral lines with excitation energies of up to 6-8 eV are emitted. The population temperature of the excited levels, which was determined from the intensity ratios of atomic spectral lines, can be interpreted as the temperature of the atmospheric-pressure plasma. The temperatures determined from different pairs of lines belonging to the same or different elements (Cu, Mo, Li, Fe) fall within the range 7000-9000 K. In the later stage of the discharge, when the characteristic plasma size reaches a few centimeters, no atomic lines are present in the spectrum, which corresponds to a Planckian continuum with a temperature of 2400-3200 K.

74 ATOMIC AND MOLECULAR PHYSICS↗

Diagnostic system for studying generation of subterahertz radiation during beam-plasma interaction in the GOL-3 facility

The design principles and construction of the subterahertz radiometric spectral systems developed for the GOL-3 facility are described. The spectral systems are designed according to the quasi-optical scheme and use multilayer filters based on frequency-selective surfaces. The design and manufacturing technology of such elements are discussed. The results of measuring subterahertz radiation of plasma at the frequency close to the double plasma frequency are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-shifted Bragg gratings in a foundry silicon nitride platform

Bragg gratings are key optical elements for applications in communications, sensing, and lasers. Phase-shifted Bragg gratings are a special case where the simple periodic structure is altered to allow a narrow spectral passband within the optical bandgap. Here, we demonstrate phase-shifted silicon nitride gratings fabricated using 193 nm deep ultraviolet lithography (DUV) on the AIM Photonics 300 mm silicon photonics foundry line. We measure the grating properties and verify the results with a transfer-matrix method (TMM) model. The standard grating expressions for extracting the coupling coefficient κ and bandwidth do not apply and are updated to account for the phase shift. These results inform future designs for on-chip grating filters and distributed feedback (DFB) lasers.

Husko, Chad (ORCID:0000000271252518)↗

Benchmark Modeling of the Near-Field and Far-Field Wave Effects of Wave Energy Arrays

This project is an industry-led partnership between Columbia Power Technologies and Oregon State University that will perform benchmark laboratory experiments and numerical modeling of the near-field and far-field impacts of wave scattering from an array of wave energy devices. These benchmark experimental observations will help to fill a gaping hole in our present knowledge of the near-field effects of multiple, floating wave energy converters and are a critical requirement for estimating the potential far-field environmental effects of wave energy arrays. The experiments will be performed at the Hinsdale Wave Research Laboratory (Oregon State University) and will utilize an array of newly developed Buoys' that are realistic, lab-scale floating power converters. The array of Buoys will be subjected to realistic, directional wave forcing (1:33 scale) that will approximate the expected conditions (waves and water depths) to be found off the Central Oregon Coast. Experimental observations will include comprehensive in-situ wave and current measurements as well as a suite of novel optical measurements. These new optical capabilities will include imaging of the 3D wave scattering using a binocular stereo camera system, as well as 3D device motion tracking using a newly acquired LED system. These observing systems will capture the 3D motion history of individual Buoys as well as resolve the 3D scattered wave field; thus resolving the constructive and destructive wave interference patterns produced by the array at high resolution. These data combined with the device motion tracking will provide necessary information for array design in order to balance array performance with the mitigation of far-field impacts. As a benchmark data set, these data will be an important resource for testing of models for wave/buoy interactions, buoy performance, and far-field effects on wave and current patterns due to the presence of arrays. Under the proposed project we will initiate high-resolution (fine scale, very near-field) fluid/structure interaction simulations of buoy motions, as well as array-scale, phase-resolving wave scattering simulations. These modeling efforts will utilize state-of-the-art research quality models, which have not yet been brought to bear on this complex problem of large array wave/structure interaction problem.

16 TIDAL AND WAVE POWER↗