Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Synthesis, Development, and Testing of High-Surface-Area Polymer-Based Adsorbents for the Selective Recovery of Uranium from Seawater

The ocean contains uranium with an approximate concentration of 3.34 ppb, which can serve as an incredible supply source to sustain nuclear energy in the United States. Unfortunately, technology currently available to recover uranium from seawater is not efficient enough and mining uranium on land is still more economical. For this study, we have developed polymer-based adsorbents with high uranium adsorption capacities by grafting amidoxime onto high-surface-area polyethylene (PE) fibers. Various process conditions have been screened, in combination with developing a rapid testing protocol (<24 h), to optimize the process. These adsorbents are synthesized through radiation-induced grafting of acrylonitrile (AN) and methacrylic acid (MAA) onto PE fibers, followed by the conversion of nitriles to amidoximes and basic conditioning. In addition, the uranium adsorption capacity, measured in units of g U /kg ads , is greatly increased by reducing the diameter of the PE fiber or changing its morphology. An increase in the surface area of the PE polymer fiber allows for more grafting sites that are positioned in more-accessible locations, thereby increasing access to grafted molecules that would normally be located in the interior of a fiber with a larger diameter. Polymer fibers with hollow morphologies are able to adsorb beyond 1 order of magnitude more uranium from simulated seawater than current commercially available adsorbents. Finally, several high-surface-area fibers were tested in natural seawater and were able to extract 5–7 times more uranium than any adsorbent reported to date.

36 MATERIALS SCIENCE↗

The miniJPAS survey quasar selection – I. Mock catalogues for classification

In this series of papers, we employ several machine learning (ML) methods to classify the point-like sources from the miniJPAS catalogue, and identify quasar candidates. Since no representative sample of spectroscopically confirmed sources exists at present to train these ML algorithms, we rely on mock catalogues. In this first paper, we develop a pipeline to compute synthetic photometry of quasars, galaxies, and stars using spectra of objects targeted as quasars in the Sloan Digital Sky Survey . To match the same depths and signal-to-noise ratio distributions in all bands expected for miniJPAS point sources in the range 17.5 ≤ r < 24, we augment our sample of available spectra by shifting the original r-band magnitude distributions towards the faint end, ensure that the relative incidence rates of the different objects are distributed according to their respective luminosity functions, and perform a thorough modelling of the noise distribution in each filter, by sampling the flux variance either from Gaussian realizations with given widths, or from combinations of Gaussian functions. Finally, we also add in the mocks the patterns of non-detections which are present in all real observations. Although the mock catalogues presented in this work are a first step towards simulated data sets that match the properties of the miniJPAS observations, these mocks can be adapted to serve the purposes of other photometric surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

NARROW-LINE X-RAY-SELECTED GALAXIES IN THE CHANDRA -COSMOS FIELD. I. OPTICAL SPECTROSCOPIC CATALOG

The COSMOS survey is a large and deep survey with multiwavelength observations of sources from X-rays to the UV, allowing an extensive study of their properties. The central 0.9 deg{sup 2} of the COSMOS field have been observed by Chandra with a sensitivity up to 1.9 × 10{sup −16} erg cm{sup −2} s{sup −1} in the full (0.5–10 keV) band. Photometric and spectroscopic identification of the Chandra -COSMOS (C-COSMOS) sources is available from several catalogs and campaigns. Despite the fact that the C-COSMOS galaxies have a reliable spectroscopic redshift in addition to a spectroscopic classification, the emission-line properties of this sample have not yet been measured. We present here the creation of an emission-line catalog of 453 narrow-line sources from the C-COSMOS spectroscopic sample. We have performed spectral fitting for the more common lines in galaxies ([O ii] λ 3727, [Ne iii] λ 3869, H β , [O iii] λλ 4959, 5007, H α , and [N ii] λλ 6548, 6584). These data provide an optical classification for 151 (i.e., 33%) of the C-COSMOS narrow-line galaxies based on emission-line diagnostic diagrams.

79 ASTRONOMY AND ASTROPHYSICS↗

BASS. XXXIII. Swift-BAT Blazars and Their Jets through Cosmic Time

We derive the most up-to-date Swift-Burst Alert Telescope (BAT) blazar luminosity function in the 14–195 keV range, making use of a clean sample of 118 blazars detected in the BAT 105 month survey catalog, with newly obtained redshifts from the BAT Active Galatic Nucleus Spectroscopic Survey. We determine the best-fit X-ray luminosity function for the whole blazar population, as well as for flat-spectrum radio quasars (FSRQs) alone. The main results are: (1) at any redshift, BAT detects the most luminous blazars, above any possible break in their luminosity distribution, which means we cannot differentiate between density and luminosity evolution; (2) the whole blazar population, dominated by FSRQs, evolves positively up to redshift z ~ 4.3, confirming earlier results and implying lower number densities of blazars at higher redshifts than previously estimated. The contribution of this source class to the cosmic X-ray background at 14–195 keV can range from 5%–18%, while possibly accounting for 100% of the MeV background. We also derived the average 14 keV–10 GeV spectral energy distribution for BAT blazars, which allows us to predict the number counts of sources in the MeV range, as well as the expected number of high-energy (>100 TeV) neutrinos. A mission like COSI will detect 40 MeV blazars, of which two may have coincident neutrino detections. Finally, taking into account beaming selection effects, the distribution and properties of the parent population of these extragalactic jets are derived. We find that the distribution of viewing angles is quite narrow, with most sources aligned within <5° of the line of sight. Moreover, the average Lorentz factor, $\langle$Γ$\rangle$ = 8–12, is lower than previously suggested for these powerful sources.

79 ASTRONOMY AND ASTROPHYSICS↗

A NEW EXTENSIVE CATALOG OF OPTICALLY VARIABLE ACTIVE GALACTIC NUCLEI IN THE GOODS FIELDS AND A NEW STATISTICAL APPROACH TO VARIABILITY SELECTION

Variability is a property shared by practically all active galactic nuclei (AGNs). This makes variability selection a possible technique for identifying AGNs. Given that variability selection makes no prior assumption about spectral properties, it is a powerful technique for detecting both low-luminosity AGNs in which the host galaxy emission is dominating and AGNs with unusual spectral properties. In this paper, we will discuss and test different statistical methods for the detection of variability in sparsely sampled data that allow full control over the false positive rates. We will apply these methods to the GOODS North and South fields and present a catalog of variable sources in the z band in both GOODS fields. Out of the 11,931 objects checked, we find 155 variable sources at a significance level of 99.9%, corresponding to about 1.3% of all objects. After rejection of stars and supernovae, 139 variability-selected AGNs remain. Their magnitudes reach down as faint as 25.5 mag in z. Spectroscopic redshifts are available for 22 of the variability-selected AGNs, ranging from 0.046 to 3.7. The absolute magnitudes in the rest-frame z band range from {approx}-18 to -24, reaching substantially fainter than the typical luminosities probed by traditional X-ray and spectroscopic AGN selection in these fields. Therefore, this is a powerful technique for future exploration of the evolution of the faint end of the AGN luminosity function up to high redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-548: Modeling of Breast IORT Using the Xoft 50 KV Brachytherapy Source and 316L Steel Rigid Shield

Purpose: Xoft provides a set of 316L Stainless Steel Rigid Shields to be used with their 50 kV X-ray source for Breast IORT treatments. Modeling the different shield sizes in MCNP provides information to help make clinical decisions for selecting the appropriate shield size. Methods: The Xoft Axxent 50 kV Electronic Brachytherapy System has several applications in radiation therapy, one of which is treating cancer of the breast intraoperatively by placing the miniaturized X-ray tube inside an applicator balloon that is expanded to fill the lumpectomy bed immediately following tumor removal. The ribs, lung, and muscular chest wall are all regions at risk to receive undesired dose during the treatment. A Xoft 316L Stainless Steel Rigid Shield can be placed between the intracostal muscles of the chest wall and the remaining breast tissue near the balloon to attenuate the beam and protect these organs. These shields are provided in 5 different sizes, and the effects on dose to the surrounding tissues vary with shield size. MCNP was used to model this environment and tally dose rate to certain regions of interest. Results: The average rib dose rate calculated using 0cm (i.e., no shield), 3cm, and 5cm diameter shields were 26.89, 15.43, and 8.91 Gy/hr respectively. The maximum dose rates within the rib reached 94.74 Gy/hr, 53.56 Gy/hr, and 31.44 Gy/hr for the 0cm, 3cm, and 5cm cases respectively. The shadowing effect caused by the steel shields was seen in the 3-D meshes and line profiles. Conclusion: This model predicts a higher dose rate to the underlying rib region with the 3cm shield compared to the 5cm shield; it may be useful to select the largest possible diameter when choosing a shield size for a particular IORT patient. The ability to attenuate the beam to reduce rib dose was also confirmed. Research sponsored by Xoft Inc, a subsidiary of iCAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated treatment planning for a dedicated multi-source intracranial radiosurgery treatment unit using projected gradient and grassfire algorithms

Purpose: The purpose of this work is to develop a framework to the inverse problem for radiosurgery treatment planning on the Gamma Knife{sup Registered-Sign} Perfexion Trade-Mark-Sign (PFX) for intracranial targets. Methods: The approach taken in the present study consists of two parts. First, a hybrid grassfire and sphere-packing algorithm is used to obtain shot positions (isocenters) based on the geometry of the target to be treated. For the selected isocenters, a sector duration optimization (SDO) model is used to optimize the duration of radiation delivery from each collimator size from each individual source bank. The SDO model is solved using a projected gradient algorithm. This approach has been retrospectively tested on seven manually planned clinical cases (comprising 11 lesions) including acoustic neuromas and brain metastases. Results: In terms of conformity and organ-at-risk (OAR) sparing, the quality of plans achieved with the inverse planning approach were, on average, improved compared to the manually generated plans. The mean difference in conformity index between inverse and forward plans was -0.12 (range: -0.27 to +0.03) and +0.08 (range: 0.00-0.17) for classic and Paddick definitions, respectively, favoring the inverse plans. The mean difference in volume receiving the prescribed dose (V{sub 100}) between forward and inverse plans was 0.2% (range: -2.4% to +2.0%). After plan renormalization for equivalent coverage (i.e., V{sub 100}), the mean difference in dose to 1 mm{sup 3} of brainstem between forward and inverse plans was -0.24 Gy (range: -2.40 to +2.02 Gy) favoring the inverse plans. Beam-on time varied with the number of isocenters but for the most optimal plans was on average 33 min longer than manual plans (range: -17 to +91 min) when normalized to a calibration dose rate of 3.5 Gy/min. In terms of algorithm performance, the isocenter selection for all the presented plans was performed in less than 3 s, while the SDO was performed in an average of 215 min. Conclusions: PFX inverse planning can be performed using geometric isocenter selection and mathematical modeling and optimization techniques. The obtained treatment plans all meet or exceed clinical guidelines while displaying high conformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MID-INFRARED SELECTION OF ACTIVE GALACTIC NUCLEI WITH THE WIDE-FIELD INFRARED SURVEY EXPLORER. II. PROPERTIES OF WISE-SELECTED ACTIVE GALACTIC NUCLEI IN THE NDWFS BOOeTES FIELD

Stern et al. presented a study of Wide-field Infrared Survey Explorer (WISE) selection of active galactic nuclei (AGNs) in the 2 deg{sup 2} COSMOS field, finding that a simple criterion W1-W2 {>=} 0.8 provides a highly reliable and complete AGN sample for W2 < 15.05, where the W1 and W2 passbands are centered at 3.4 {mu}m and 4.6 {mu}m, respectively. Here we extend this study using the larger 9 deg{sup 2} NOAO Deep Wide-Field Survey Booetes field which also has considerably deeper WISE observations than the COSMOS field, and find that this simple color cut significantly loses reliability at fainter fluxes. We define a modified selection criterion combining the W1-W2 color and the W2 magnitude to provide highly reliable or highly complete AGN samples for fainter WISE sources. In particular, we define a color-magnitude cut that finds 130 {+-} 4 deg{sup -2} AGN candidates for W2 < 17.11 with 90% reliability. Using the extensive UV through mid-IR broadband photometry available in this field, we study the spectral energy distributions of WISE AGN candidates. We find that, as expected, the WISE AGN selection can identify highly obscured AGNs, but that it is biased toward objects where the AGN dominates the bolometric luminosity output. We study the distribution of reddening in the AGN sample and discuss a formalism to account for sample incompleteness based on the step-wise maximum-likelihood method of Efstathiou et al. The resulting dust obscuration distributions depend strongly on AGN luminosity, consistent with the trend expected for a receding torus. At L{sub AGN} {approx} 3 Multiplication-Sign 10{sup 44} erg s{sup -1}, 29% {+-} 7% of AGNs are observed as Type 1, while at {approx}4 Multiplication-Sign 10{sup 45} erg s{sup -1} the fraction is 64% {+-} 13%. The distribution of obscuration values suggests that dust in the torus is present as both a diffuse medium and in optically thick clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

Potential–Dependent BDAC Adsorption on Zinc Enabling Selective Suppression of Zinc Corrosion for Energy Storage Applications

Utility-scale zinc (Zn) batteries are a promising solution to address the problem of intermittency of renewable energy sources; however, Zn-metal anodes in these batteries suffer from capacity loss due to spontaneous corrosion of the Zn especially when high-surface area anode configurations are employed. Additionally, Zn dendrites are known to form during battery charging limiting the cycle-life of these batteries. Electrolyte additives have been explored that prevent aforementioned issues, but these too come at a cost, i.e., surface-blocking additives polarize the electrode surface leading to loss in the voltaic and energy efficiencies of the battery. In this contribution, a novel electrolyte additive, benzyldimethylhexadecylammonium chloride (BDAC), is investigated for its ability to suppresses corrosion of Zn in an acidic (pH = 3) electrolyte. An attribute of BDAC distinct from previously studied additives is that it selectively suppresses electrochemical activity when the Zn electrode is at its corrosion potential; however, during high-rate Zn deposition (charging) or stripping (discharging), BDAC is essentially deactivated and thus it does not appreciably polarize the electrode surface, thus minimizing voltaic efficiency losses. This selective corrosion suppression behavior is explored using slow-scan voltammetry, which reveals hysteresis implying a potential- or current-dependent BDAC adsorption mechanism in which BDAC reaches higher surface coverages when the partial currents at the Zn surface are low (e.g., at or near the corrosion potential), but BDAC coverage is reduced considerably when the Zn deposition or stripping rates are increased. Numerical simulations of the BDAC diffusion-adsorption process corroborate this mechanism. Ramifications of our approach to the selective suppression of Zn dendrites are discussed.

25 ENERGY STORAGE↗

Studies for the selection of fully contained muon neutrino CC events in the ICARUS T600 detector at Fermilab

The ICARUS T600 LAr-TPC detector has started its new physics runs in June 2022 at Fermilab within the SBN program. This detector is recording neutrino interactions from the Booster BNB neutrino beam in order to definitively clarify the open questions related to the possible existence of sterile neutrinos, as suggested by numerous observed experimental anomalies. In addition the neutrinos events recorded from the NuMI off-axis beam are under study in order to perform neutrino-Argon cross section measurements. At Fermilab, ICARUS is facing a challenging experimental condition: the detector is presently installed essentially at Earth surface where cosmic ray particles can become a serious source of background for the neutrino event search. This condition makes it necessary to deploy suitable automatic tools for the identification, selection, and measurement of the neutrino events among the millions of events triggered by cosmics. In this contribution, two automatic selection procedures devoted to the identification of fully contained muon neutrino interactions in the BNB neutrino beam will be presented, together with the first results of their application on simulated and on recently recorded events in the T600 detector.

Farnese, Christian [INFN, Padua] (ORCID:0000000163↗

Studies for the Selection of Fully Contained Muon Neutrino CC Events in the ICARUS T600 Detector at Fermilab

The ICARUS T600 LAr-TPC detector has started its new physics runs in June 2022 at Fermilab within the SBN program. This detector is recording neutrino interactions from the Booster BNB neutrino beam in order to definitively clarify the open questions related to the possible existence of sterile neutrinos, as suggested by numerous observed experimental anomalies. In addition the neutrinos events recorded from the NuMI off-axis beam are under study in order to perform neutrino-Argon cross section measurements. At Fermilab, ICARUS is facing a challenging experimental condition: the detector is presently installed essentially at Earth surface where cosmic ray particles can become a serious source of background for the neutrino event search. This condition makes it necessary to deploy suitable automatic tools for the identification, selection, and measurement of the neutrino events among the millions of events triggered by cosmics. In this contribution, two automatic selection procedures devoted to the identification of fully contained muon neutrino interactions in the BNB neutrino beam will be presented, together with the first results of their application on simulated and on recently recorded events in the T600 detector.

Farnese, Christian [INFN, Padua]↗

Estimation of hydraulic conductivity in a watershed using sparse multi-source data via Gaussian process regression and Bayesian experimental design

Enhanced water management systems depend on accurate estimation of subsurface hydraulic properties. However, geologic formations can vary significantly, so information from a single source (e.g., widely spaced boreholes) is insufficient in characterizing subsurface aquifer properties. Therefore, multiple sources of information are needed to complement the hydrogeology understanding of a region. Here, this study presents a numerical framework in which information from different measurement sources is combined to characterize the 3D random field in a multi-fidelity prediction model. Coupled with the model, a Bayesian experimental design was used to determine the best future sampling locations. The Upper Sangamon watershed in east-central Illinois was selected as the case study site, where the multi-fidelity Gaussian process model was used to estimate the hydraulic conductivity in the region of interest. Multi-source observation data were obtained from electrical resistivity and borehole pumping tests. The accuracy of the model prediction is dependent on the locations and the distribution of both high- and low-fidelity data. Furthermore, the multi-fidelity model was compared with the single-fidelity model. The uncertainties and confidence in the measurements and parameter estimates were quantified and used to design future cycles of data collection to further improve the confidence intervals.

54 ENVIRONMENTAL SCIENCES↗

Endovascular Embolization of Bronchial Artery Originating from the Upper Portion of Aortic Arch in Patients with Massive Hemoptysis

Purpose: Our experience with endovascular embolization (EVE) of the bronchial artery (BA) originating from the upper portion of the aortic arch (AA) in six patients is described. Methods: Altogether, 818 patients with hemoptysis underwent multidetector row computed tomography angiography (MDCTA) before EVE or AA angiography during EVE. Aberrant BAs originating from the upper portion of the AA were the source of massive hemoptysis in six patients (0.73 %). MDCT angiograms and/or Digital subtraction angiograms were retrospectively reviewed. Selective catheterization and embolization were performed. Results: The ostia of the BAs were located on the superior surface of the AA between the brachiocephalic trunk and left common carotid artery in three patients, the junction of the aorta and medial surface of the left subclavian artery in two, and the posterior wall of the upper portion of the AA in one. The six BAs comprised two common trunks, three single right sides, and one single left side. The targeted vessels were successfully catheterized and embolized by a coaxial microcatheter system using polyvinyl alcohol particles. Other pathologic BAs and nonbronchial systemic arteries also were embolized. Bleeding was immediately controlled in all patients with no recurrence of hemoptysis. No procedure-related complications occurred. Conclusions: Application of EVE of anomalous origin of BAs in patients with hemoptysis is important, as demonstrated in the six reported patients. MDCTA before EVE or AA angiography during EVE is critical to avoid missing a rare aberrant BA originating from the upper portion of the AA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation route to aqueous synthesis of highly luminescent ZnSe quantum dots and its function as a copper ion fluorescence sensor

Highlights: • Radiation chemical technique can provide a useful route for synthesis of ZnSe QDs. • Chelating nature of ethylene diamine is exploited for capping nanoparticles. • ZnSe QDs can be a suitable sensitive alternative to toxic cadmium-based system. • Cu(II) ion is probed by QDs in the presence of other physiologically relevant ions. - Abstract: Size-controlled synthesis of stable ZnSe QDs with narrow distribution in aqueous environment through conventional soft chemical method still poses a challenge. The proposed radiation assisted strategy demonstrates aqueous synthesis of stable, monodisperse and luminescent ZnSe QDs capped with chelating ethylene diamine under ambient conditions and at room temperature. Radiation chemical method facilitates in slow and in-situ release of selenium ion from sodium selenosulfate. The concentrations of precursors, such as zinc salt, selenium source, ethylene diamine and absorbed radiation (7–90 kGy) dose were optimized for obtaining good quality particles. Selective quenching of luminescence of as-synthesized quantum dots (QDs) by Cu{sup 2+} ions vis-à-vis other physiologically important cations provide evidence for use of ZnSe quantum dots as alternative to toxic Cd-based quantum dots to probe Cu{sup 2+} ions. The linear relation of ratio of loss in emission intensity as a function of concentration of Cu(II) indicates detection limit in nano-molar range.

36 MATERIALS SCIENCE↗

Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry

In addition to serving as an f-element ligand and rare-earth method complexing agent, tributyl phosphate (TBP) is a compound containing core functional groups that mimic those routinely found in degradation products from industrial processes. Because detection of trace quantities of TBP can provide insight into the routes of contamination and degradation in the environment, there is a need to develop methods capable of detecting trace quantities of TBP. Vapor detection at atmospheric pressure is one approach that is both sensitive and rapid. We present here the use of atmospheric flow tube mass spectrometry (AFT-MS) for the ambient vapor sampling of TBP from headspace of ppb-level solutions in methanol. Gas phase clustering reactions were to enhance detection levels via the addition of small quantities of the dopants diethylamine (DEA), triethylamine (TEA), and pinacolyl methylphosphonate (PMP) in the vapor stream. Detection of the TBP vapor emanating from these solutions demonstrated a linear range for the protonated TBP species of 1-1000 ppb from solution. The clusters of TBP with DEA, TEA, and PMP each yielded linear ranges of 1-250 ppb for TBP in solution. Despite smaller linear ranges, the addition of these dopant species added a layer of analytical selectivity and reduced variability in signals from quality control samples. These data were obtained using an AFT source coupled to a linear ion trap mass spectrometer, which demonstrates the applicability of trapping systems to the AFT ionization technique while monitoring positive ions.

Ambient vapor sampling, Dielectric barrier dischar↗

Design principles of tandem cascade photoelectrochemical devices

Cascade photoelectrocatalysis (PEC) is a possible method to improve the selectivity of solar-driven CO 2 reduction (CO 2 R). This concept can be realized by coupling different CO 2 R catalysts to different subcells in a multijunction photovoltaic (PV) stack. Efficient implementation will require careful tuning of the photocurrents and design of the photovoltages provided by the subcells to the CO 2 R catalysts in such a way as to facilitate the target reaction. Here, we outline the design principles of the tandem PEC approach using two-step conversion of CO 2 to ethylene in aqueous electrolyte, via a CO intermediate, as a model system. To perform this reaction, the first coupled PV-catalyst component should provide 4 electrons to reduce 2 molecules of CO 2 to CO; the second component should provide 8 electrons to reduce 2 CO molecules to C 2 H 4 . Based on known CO 2 R catalysts, the overpotential required to produce CO can be less than that required to reduce it to ethylene, creating the opportunity for improved efficiency. Cascade PEC can be realized in a three-terminal tandem (3TT) configuration using III–V-semiconductor based subcells coupled to Au (produces CO intermediate) and Cu (converts CO to ethylene). The current to each catalyst can be controlled by the area of the subcell exposed to the electrolyte, and the photovoltage is determined by the materials selected and device configuration. Operating conditions are found by simulating the coupled system using the open-source circuit simulator SPICE (Simulation Program with Integrated Circuits Emphasis). We identify conditions under which a 3TT configuration can have a higher solar to chemical conversion efficiency compared to a two-terminal two-junction tandem (2T 2J) with the same absorbers and a Cu catalyst only. We also show that 3TT PEC devices can be less sensitive to variations in catalyst activity compared to 2T devices. Lastly, we discuss the applications of cascade PEC to CO 2 reduction, using different intermediates, and to other chemical networks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detecting Rare Events in the Time-Domain

One of the biggest challenges in current and future time-domain surveys is to extract the objects of interest from the immense data stream. There are two aspects to achieving this goal: detecting variable sources and classifying them. Difference imaging provides an elegant technique for identifying new transients or changes in source brightness. Much progress has been made in recent years toward refining the process. We discuss a selection of pitfalls that can afflict an automated difference imagine pipeline and describe some solutions. After identifying true astrophysical variables, we are faced with the challenge of classifying them. For rare events, such as supernovae and microlensing, this challenge is magnified because we must balance having selection criteria that select for the largest number of objects of interest against a high contamination rate. We discuss considerations and techniques for developing classification schemes.

99 GENERAL AND MISCELLANEOUS↗

Cross sections for electron capture and excitation in collisions of Li{sup q+} (q=1, 2, 3) with atomic hydrogen

The two-center atomic orbital close-coupling method is employed to study electron capture and excitation reactions in collisions of Li{sup q+} (q = 1-3) ions with ground state atomic hydrogen in the ion energy range from 0.1 keV/u to 300 keV/u, where u is the atomic mass unit. The interaction of the active electron with the projectile ions (Li{sup +}, Li{sup 2+}) is represented by a model potential. Total and state-selective cross sections for charge transfer and excitation processes are calculated and compared with data from other sources when available.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗