Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Ultrafast X-ray Sources

Since before the scattering of X-rays off of DNA led to the first understanding of the double helix structure, sources of X-rays have been an essential tool for scientists examining the structure and interactions of matter. The resolution of a microscope is proportional to the wavelength of light so x-rays can see much finer structures than visible light, down to single atoms. In addition, the energy of X-rays is resonant with the core atomic levels of atoms so with appropriate wavelengths the placement of specific atoms in a large molecule can be determined. Over 10,000 scientists use synchrotron sources, storage rings of high energy electrons, each year worldwide. As an example of such use, virtually every picture of a protein or drug molecule that one sees in the scientific press is a reconstruction based on X-ray scattering of synchrotron light from the crystallized form of that molecule. Unfortunately those pictures are static and proteins work through configuration (shape) changes in response to energy transfer. To understand how biological systems work requires following the energy flow to these molecules and tracking how shape changes drive their interaction with other molecules. We'd like to be able to freeze the action of these molecules at various steps along the way with an X-ray strobe light. How fast does it have to be? To actually get a picture of a molecule in a fixed configuration requires X-ray pulses as short as 30 femtoseconds (1/30 of a millionth of a millionth of a second). To capture the energy flow through changes in electronic levels requires a faster strobe, less than 1 femtosecond! And to acquire such information in smaller samples with higher accuracy demands brighter and brighter X-rays. Unfortunately modern synchrotrons (dubbed 3rd Generation Light Sources) cannot deliver such short bright pulses of X-rays. An entirely new approach is required, linear-accelerator (linac-)-based light sources termed 4th or Next Generation Light Sources (NGLSs). Although NGLSs will not displace synchrotrons from their role they do offer exciting new capabilities which can be understood from the physics of the light production in each device.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

U.S.-CHINA RADIOLOGICAL SOURCE SECURITY PROJECT: CONTINUING AND EXPANDING BILATERAL COOPERATION

The successful radiological security cooperation between the U.S. and China to secure at-risk sites near venues of the 2008 Beijing Summer Olympics has led to an expanded bilateral nonproliferation cooperation scope. The U.S. Department of Energy’s National Nuclear Security Administration, the Chinese Atomic Energy Authority and the China Ministry of Environmental Protection are continuing joint efforts to secure radiological sources throughout China under the U.S.-China Peaceful Uses of Nuclear Technology (PUNT) Agreement. Joint cooperation activities include physical security upgrades of sites with International Atomic Energy Agency (IAEA) Category 1 radiological sources, packaging, recovery, and storage of high activity transuranic and beta gamma sources, and secure transportation practices for the movement of recovered sources. Expansion of cooperation into numerous provinces within China includes the use of integrated training workshops that will demonstrate methodologies and best practices between U.S. and Chinese radiological source security and recovery experts. The fiscal year 2009 expanded scope of cooperation will be conducted similar to the 2008 Olympic cooperation with the Global Threat Reduction Initiative taking the lead for the U.S., PUNT being the umbrella agreement, and Los Alamos, Sandia, and Oak Ridge National Laboratories operating as technical working groups. This paper outlines the accomplishments of the joint implementation and training efforts to date and discusses the possible impact on future U.S./China cooperation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fukushima Daiichi reactor source term attribution using cesium isotope ratios from contaminated environmental samples

Source term attribution of environmental contamination following the Fukushima Daiichi Nuclear Power Plant (FDNPP) disaster is complicated by a large number of possible similar emission source terms (e.g. FDNPP reactor cores 1–3 and spent fuel ponds 1–4). Cesium isotopic analyses can be utilized to discriminate between environmental contamination from different FDNPP source terms and, if samples are sufficiently temporally resolved, potentially provide insights into the extent of reactor core damage at a given time. In this work, rice, soil, mushroom, and soybean samples taken 100–250 km from the FDNPP site were dissolved using microwave digestion. Radiocesium was extracted and purified using two sequential ammonium molybdophosphate-polyacrylonitrile columns, following which 135 Cs/ 137 Cs isotope ratios were measured using thermal ionization mass spectrometry (TIMS). Results were compared with data reported previously from locations to the northwest of FDNPP and 30 km to the south of FDNPP. 135 Cs/ 137 Cs isotope ratios from samples 100–250 km to the southwest of the FDNPP site show a consistent value of 0.376 ± 0.008. 135 Cs/ 137 Cs versus 134 Cs/ 137 Cs correlation plots suggest that radiocesium to the southwest is derived from a mixture of FDNPP reactor cores 1, 2, and 3. Conclusions from the cesium isotopic data are in agreement with those derived independently based upon the event chronology combined with meteorological conditions at the time of the disaster. In conclusion, cesium isotopic analyses provide a powerful tool for source term discrimination of environmental radiocesium contamination at the FDNPP site. For higher precision source term attribution and forensic determination of the FDNPP core conditions based upon cesium, analyses of a larger number of samples from locations to the north and south of the FDNPP site (particularly time-resolved air filter samples) are needed. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Numerical Simulation of Ion Transport in a Nano-Electrospray Ion Source at Atmospheric Pressure

Understanding ion transport properties from the ion source to the mass spectrometer (MS) is essential for optimizing device performance. Numerical simulation helps in understanding of ion transport properties and, furthermore, facilitates instrument design. In contrast to previously reported numerical studies, ion transport simulations in a continuous injection mode whilst considering realistic space-charge effects have been carried out. The flow field was solved using Reynolds-averaged Navier-Stokes (RANS) equations, and a particle-in-cell (PIC) method was applied to solve a time-dependent electric field with local charge density. A series of ion transport simulations were carried out at different cone gas flow rates, ion source currents, and capillary voltages. A force evaluation analysis reveals that the electric force, the drag force, and the Brownian force are the three dominant forces acting on the ions. Both the experimental and simulation results indicate that cone gas flow rates of ≤250 slph (standard liter per hour) are important for high ion transmission efficiency, as higher cone gas flow rates reduce the ion signal significantly. The simulation results also show that the ion transmission efficiency reduces exponentially with an increased ion source current. Additionally, the ion loss due to space-charge effects has been found to be predominant at a higher ion source current, a lower capillary voltage, and a stronger cone gas counterflow. The interaction of the ion driving force, ion opposing force, and ion dispersion is discussed to illustrate ion transport mechanism in the ion source at atmospheric pressure. .

42 ENGINEERING↗

Microplasma-based flowing atmospheric-pressure afterglow (FAPA) source for ambient desorption-ionization mass spectrometry

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a timeof- flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. Here, the mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-consistent field theory of collisions: Orbital equations with asymptotic sources and self-averaged potentials

The self-consistent field theory of collisions is formulated, incorporating the unique dynamics generated by the self-averaged potentials. The bound state Hartree–Fock approach is extended for the first time to scattering states, by properly resolving the principal difficulties of non-integrable continuum orbitals and imposing complex asymptotic conditions. The recently developed asymptotic source theory provides the natural theoretical basis, as the asymptotic conditions are completely transferred to the source terms and the new scattering function is made fullyintegrable. The scattering solutions can then be directly expressed in terms of bound state HF configurations, establishing the relationship between the bound and scattering state solutions. Alternatively, the integrable spin orbitals are generated by constructing the individual orbital equations that contain asymptotic sources and self-averaged potentials. However, the orbital energies are not determined by the equations, and a special channel energy fixing procedure is developed to secure the solutions. It is also shown that the variational construction of the orbital equations has intrinsic ambiguities that are generally associated with the self-consistent approach. On the other hand, when a small subset of open channels is included in the source term, the solutions are only partiallyintegrable, but the individual open channels can then be treated more simply by properly selecting the orbital energies. The configuration mixing and channel coupling are then necessary to complete the solution. The new theory improves the earlier continuum HF model. - Highlights: • First extension of HF to scattering states, with proper asymptotic conditions. • Orbital equations with asymptotic sources and integrable orbital solutions. • Construction of self-averaged potentials, and orbital energy fixing. • Channel coupling and configuration mixing, involving the new orbitals. • Critical evaluation of the continuum HF and its improvements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exergy Analysis of a Two-Stage Ground Source Heat Pump with a Vertical Bore for Residential Space Conditioning under Simulated Occupancy

This twelve-month field study analyzes the performance of a 7.56W (2.16- ton) water-to-air-ground source heat pump (WA-GSHP) to satisfy domestic space conditioning loads in a 253 m 2 house in a mixed-humid climate in the United States. The practical feasibility of using the ground as a source of renewable energy is clearly demonstrated. Better than 75% of the energy needed for space heating was extracted from the ground. The average monthly electricity consumption for space conditioning was only 40 kWh at summer and winter thermostat set points of 24.4°C and 21.7°C, respectively. The WA-GSHP shared the same 94.5 m vertical bore ground loop with a separate water-to-water ground-source heat pump (WW-GSHP) for meeting domestic hot water needs in the same house. Sources of systemic irreversibility, the main cause of lost work are identified using Exergy and energy analysis. Quantifying the sources of Exergy and energy losses is essential for further systemic improvements. The research findings suggest that the WA-GSHPs are a practical and viable technology to reduce primary energy consumption and greenhouse gas emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 targets of using renewable energy resources.

15 GEOTHERMAL ENERGY↗

Contaminant point source localization error estimates as functions of data quantity and model quality

We develop empirically-grounded error envelopes for localization of a point contamination release event in the saturated zone of a previously uncharacterized heterogeneous aquifer into which a number of plume-intercepting wells have been drilled. We assume that flow direction in the aquifer is known exactly and velocity is known to within a factor of two of our best guess from well observations prior to source identification. Other aquifer and source parameters must be estimated by interpretation of well breakthrough data via the advection-dispersion equation. We employ high performance computing to generate numerous random realizations of aquifer parameters and well locations, simulate well breakthrough data, and then employ unsupervised machine optimization techniques to estimate the most likely spatial (or space-time) location of the source. Tabulating the accuracy of these estimates from the multiple realizations, we relate the size of 90% and 95% confidence envelopes to the data quantity (number of wells) and model quality (fidelity of ADE interpretation model to actual concentrations in a heterogeneous aquifer with channelized flow). We find that for purely spatial localization of the contaminant source, increased data quantities can make up for reduced model quality. For space-time localization, we find similar qualitative behavior, but significantly degraded spatial localization reliability and less improvement from extra data collection. Since the space-time source localization problem is much more challenging, we also tried a multiple-initial-guess optimization strategy. Furthermore, this greatly enhanced performance, but gains from additional data collection remained limited.

54 ENVIRONMENTAL SCIENCES↗

Consistency of vendor-specified activity values for {sup 192}Ir brachytherapy sources

A long-term comparison was done between the manufacturer-stated {sup 192}Ir activity and the measured {sup 192}Ir activities determined with a well-type ionization chamber. Sources for a Nucletron Micro Selectron high-dose-rate (HDR) unit were used for this purpose. The radioactive sources reference activities were determined using a PTW well-type ionization chamber traceable to the National Institute of Standards and Technology Primary Calibration Laboratory. The measurements were taken in a period of 56 months with 17 different radioactive sources. The manufacturer stated activities were taken from the source calibration certificate provided by the manufacturer. These values were compared with the measured activities. The results have shown that both the percentage deviation of the monthly control measurements with the well-type chamber and the ratio between the measured activities to the manufacturer-stated value lie within {+-} 2.5%. These results were compared with similar published data and with uncertainty level (3% of the mean and 5% maximum deviation from mean) for brachytherapy sources calibration recommended by the AAPM. It was concluded that a threshold level of {+-}2.5% can be used as a suitable quality assurance indicator to spot problems in our department. The typical {+-}5% uncertainty as provided by the manufacturers may be tightened to {+-}3% to be more in line with published AAPM reports.

61 RADIATION PROTECTION AND DOSIMETRY↗

Off-axis viewing of radiation emission by long wiggler sources

When high-brilliance radiation is needed for experiments, insertion device sources are generally viewed on-axis. Off-axis emission of flux can be prodigious especially from wiggler sources having large emission fans. The on-axis and off-axis radiation emission characteristics from insertion device sources have been calculated extensively and are well known, but experimental verifications of some characteristics, particularly those associated with off-axis emission, are relatively few. Here measurements of the flux spectrum and apparent source size are described, as a function of horizontal emission angle, from the former X25 hybrid wiggler at the National Synchrotron Light Source (NSLS).

36 MATERIALS SCIENCE↗

Fission-neutrons source with fast neutron-emission timing

A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252 Cf. The time is provided by registering the fission fragments in a layer of a thin scintillation film with a signal rise time of 1 ns. The scintillation light output is measured by two silicon photomultipliers with rise time of 0.5 ns. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements using it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is also given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of the Major Source and Sink of Methylmercury in the Florida Everglades

Mercury methylation and/or demethylation have been observed in several compartments [soil (saturated soils covered by standing water), floc, periphyton, and water] of the Everglades, a wetland with mercury as one of the major water quality concerns. However, it is still unclear which compartment is the major source or sink due to the lack of estimation and comparison of the net methylmercury (MeHg) production or degradation in these compartments. The lack of this information has limited our understanding of Hg cycling in this ecosystem. This study adopted a double stable isotope (199Hg2+ and Me201Hg) addition technique to determine the methylation/demethylation rate constants and the net MeHg production rates in each compartment. This study improved the previous models for estimating these parameters by (1) taking into account the difference between newly input and ambient mercury in methylation/demethylation efficiency and (2) correcting the contribution of photodemethylation to Me199Hg concentration when calculating methylation rates in water. The net MeHg production rate in each compartment was then estimated to identify the major sources and sinks of MeHg. The results indicate that these improvements in modeling are necessary, as a significant error would occur otherwise. Soil was identified to be the largest source of MeHg in the Everglades, while the floc and water column were identified as the major sinks. The role of periphyton varies, appearing to be a source in the northern Everglades and a sink in the southern Everglades. Soil could be the largest source for MeHg in the water column, while methylation in periphyton could also contribute significantly in the northern Everglades.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatial variability of mercury wet deposition in eastern Ohio: summertime meteorological case study analysis of local source influences

Extensive exploration of event precipitation data in the Ohio River Valley indicates that coal combustion emissions play an important role in mercury (Hg) wet deposition. During July-September 2006, an intensive study was undertaken to discern the degree of local source influence. Source-receptor relationships were explored by establishing a set of wet deposition sites in and around Steubenville, Ohio. For the three month period of study, volume-weighted mean Hg concentrations observed at the eight sites ranged from 10.2 to 22.3 ng L{sup -1}, but this range increased drastically on an event basis with a maximum concentration of 89.4 ng L{sup -1} and a minimum concentration of 4.1 ng L{sup -1}. A subset of events was explored in depth, and the degree of variability in Hg concentrations between sites was linked to the degree of local source enhancement. Samples collected at sites less than 1 km from coal-fired utility stacks (near-field) exhibited up to 72% enhancement in Hg concentrations over regionally representative samples on an event basis. Air mass transport and precipitating cell histories were traced in order to evaluate relationships between local point sources and receptor sites. It was found that the interaction of several dynamic atmospheric parameters combined to favor local Hg concentration enhancement over the more regional contribution. When significant meteorological factors (wind speed at time of maximum rain rate, wind speed 24 h prior to precipitation, mixing height, and observed ceiling) were explored, it was estimated that during summertime precipitation, 42% of Hg concentration in near-field samples could be attributed to the adjacent coal-fired utility source. 28 refs., 3 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

The use and characterization of a backilluminated charge-coupled device in investigations of pulsed x-ray and radiation sources

Examinations of bremsstrahlung and energetic electron beams from a novel laser plasma source motivate and assist characterization of a backthinned, backilluminated direct detection x-ray charge-coupled device (CCD), a topology that is uncommon in hard x-ray work. Behavior toward pseudomonochromatic ({sup 55}Fe) and multichromatic ({sup 241}Am) sources is briefly reviewed under optimized noise conditions. Results collectively establish the previously unknown functional depth structure. Several modes of usage are illustrated in {approx}4-20 keV x-ray laser plasma source investigations, where the significance of the characterization is briefly discussed. The spectral redistribution associated with this CCD topology is unfavorable, yet appropriate analysis ensures that sufficient spectral information remains for quantitative determination of broadband x-ray flux and spectra in essentially single laser shot measurements. The energy dependence of nascent electron cloud radii in silicon is determined using broadband x-rays from the laser plasma source, turning the narrow depletion depth to advantage. Finally, the characterization is used to quantify recent x-ray spectral explorations of the water jet laser plasma source operating under aspirator vacuum. These results will have key value for establishment of laboratory based ultrafast extended x-ray absorption fine structure experiments using microbolometric detectors.

43 PARTICLE ACCELERATORS↗

A continuous kilohertz Cu K{alpha} source produced by submillijoule femtosecond laser pulses for phase contrast imaging

We report a continuously operated Cu K{alpha} x-ray source produced by a commercial kilohertz submillijoule femtosecond laser system. The source has an x-ray conversion of {approx}4x10{sup -5} into K{alpha} line emission at 8.05 keV. The microplasma x-ray source has a size of 8 {mu}m (full width at half maximum) produced by focusing 260 {mu}J laser pulses on a moving Cu-wire target. An average photon flux of {approx}1.1x10{sup 9} photons/sr/s is obtained using the above laser pulses. The source has been used to record phase contrast images of test samples. This compact x-ray source can serve as a low cost operating system for phase contrast imaging in clinical applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of compact size penning ion source for compact neutron generator

For long-life operation, easy to mount and compact in size penning type ion sources are widely used in different fields of research such as neutron generators, material research, and surface etching. One penning type ion source has been developed in our laboratory. Applying high voltage of 2 kV between two oppositely biased electrodes and using permanent magnet of 500 gauss magnetic field along the axis, we had produced the glow discharge in the plasma region. The performance of this source was investigated using nitrogen gas. Deuterium ions were produced and extracted on the basis of chosen electrodes and the angle of extraction. Using a single aperture plasma electrode, the beam was extracted along the axial direction. The geometry of plasma electrode is an important factor for the efficient extraction of the ions from the plasma ion source. The extracted ion current depends upon the shape of the plasma meniscus. A concave shaped plasma meniscus produces converged ion beam. The convergence of extracted ions is related to the extraction electrode angle. The greater the angle, the more the beam converges. We had studied experimentally this effect with a compact size penning ion source. The detailed comparison among the different extraction geometry and different electrode angle are discussed in this paper.

43 PARTICLE ACCELERATORS↗