Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sheaths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Cryoablation of the Spine in a Swine Model: Clinical, Radiological, and Pathological Findings with Light and Electron Microscopy

PurposeThis study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body.MethodsThe institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO{sub 2}) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia.ResultsCBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO{sub 2} epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p < 0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed.ConclusionsCBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vascular Closure Devices in Interventional Radiology Practice

Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants are used. There are a variety of vascular closure devices (VCDs) available to overcome these limitations. This review gives an overview of current VCDs, their mechanism of action, individual strengths and weaknesses, evidence base and utility in interventional radiology (IR) practice. The majority of the published evidence on VCDs is derived from patients undergoing cardiac interventions, which should be borne in mind when considering the applicability and transfer of this data for general IR practice. Overall, the evidence suggests that most VCDs are effective in achieving haemostasis with a similar rate of complications to MC although the complication profile associated with VCDs is distinct to that of MC. There is insufficient evidence to comparatively analyse the different types of VCDs currently available or reliably judge their cost-effectiveness. The interventional radiologist should have a thorough understanding of the available techniques for haemostasis and be able to identify and utilise the most appropriate strategy and closure technique for the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur

PurposeTo compare the efficacy of percutaneous cementoplasty (PCP) with and without interventional internal fixation (IIF) on malignant impending pathological fracture of proximal femur.MethodsA total of 40 patients with malignant impending pathological fracture of proximal femur were selected for PCP and IIF (n = 19, group A) or PCP alone (n = 21, group B) in this non-randomized prospective study. Bone puncture needles were inserted into the proximal femur, followed by sequential installation of the modified trocar inner needles through the puncture needle sheath. Then, 15–45 ml cement was injected into the femur lesion.ResultsThe overall excellent and good pain relief rate during follow-ups were significantly higher in group A than that in group B (89 vs. 57 %, P = 0.034). The average change of VAS, ODI, KPS, and EFES in group A were significantly higher than those in group B at 1-, 3-, 6-month, 1-year (P < 0.05). Meanwhile, The stability of the treated femur was significantly higher in group A than that in group B (P < 0.05).ConclusionPCP and IIF were not only a safe and effective procedure, but resulted in greater pain relief, bone consolidation, and also reduced the risk of fracture than the currently recommended approach of PCP done on malignant proximal femoral tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plug Anchoring Technique to Stabilize the Delivery System for Microcoil Embolization

PurposeTo evaluate the feasibility of a novel embolization technique, the Amplatzer vascular plug (AVP) anchoring technique, to stabilize the delivery system for microcoil embolization.Materials and methodsThree patients were enrolled in this study, including two cases of internal iliac artery aneurysms and one case of internal iliac arterial occlusion prior to endovascular aortic repair. An AVP was used in each case for embolization of one target artery, and the AVP was left in place. The AVP detachment wire was then used as an anchor to stabilize the delivery system for microcoil embolization to embolize the second target artery adjacent to the first target artery. The microcatheter for the microcoils was inserted parallel to the AVP detachment wire in the guiding sheath or catheter used for the AVP.ResultsThe AVP anchoring technique was achieved and the microcatheter was easily advanced to the second target artery in all three cases.ConclusionThe AVP anchoring technique was found to be feasible to advance the microcatheter into the neighboring artery of an AVP-embolized artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Associated with Advanced Inferior Vena Cava Filter Removals: A Single-Center Retrospective Study of 203 Patients Over 7 Years

PurposeTo identify factors associated with advanced inferior vena cava filter (IVCF) retrieval to raise awareness on technical considerations, retrieval efficiency, and patient safety.Materials and MethodsA single-center retrospective review was performed of 203 consecutive retrievable IVC filters placed between 2007 and 2014. Attempted retrievals were classified as advanced if the routine “snare and sheath” technique was initially unsuccessful after multiple attempts, or an alternate endovascular maneuver or access site was utilized. Patient and filter characteristics were recorded.Results203 attempted retrievals were reviewed (48.7 % male, 51.2 % female, mean age 52.7 years, mean dwell time 109 days). Advanced retrievals were observed in 20 patients (9.8 %) (15 females, 5 males). Fluoroscopy time (p ≤ 0.01, 34.3 ± 21.1 and 5.3 ± 4.5 min for advanced retrievals and routine retrievals respectively, same below), gender (p = 0.031), and retrieval tilt angle (p ≤ 0.01, 5.7 ± 5.10° vs. 11.9 ± 11.03°) were associated with advanced retrievals. Females were 3.16 times more likely to have an advanced retrieval performed than males with a significantly higher tilt angle in those with advanced retrieval. History of cancer (p = 0.502), dwell time (p = 0.916), retrieval caval diameter (p = 0.053), placement caval diameter (p = 0.365), filter type (p = 0.710), strut perforation (p = 0.506), placement tilt angle (p = 0.311), and age (p = 0.558) were not found significantly associated with advanced retrievals.ConclusionsWomen are at increased risk for advanced filter retrieval secondary to a significant change in filter tilt over time compared to men, independent of filter type or competing demographic or filter risks, likely placing them at increased risk for higher procedural fluoroscopy times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-Case Treatment of Peripheral Arterial Disease: Results from a Multi-Center European Study

PurposeThe purpose of the study was to investigate safety and feasibility of day-case endovascular procedures for the management of peripheral arterial disease.Materials and MethodsThis was a multi-center, retrospective study including all patients treated over a 30-month period with endovascular angioplasty or stenting for intermittent claudication (IC) or critical limb ischemia (CLI) on a day-case basis, in Interventional Radiology (IR) departments of three European tertiary hospitals. Exclusion criteria were not related to the type of lesion and included unavailability of an adult able to take care of patient overnight; high bleeding risk and ASA score ≥4. Primary efficacy outcome was the rate of procedures performed on an outpatient basis requiring no further hospitalization and primary safety outcome was freedom from 30-day major complications’ rate.ResultsThe study included 652 patients (male 75 %; mean age 68 ± 10 years; range: 27–93), 24.6 % treated for CLI. In 53.3 % of the cases a 6Fr sheath was used. Technical success was 97.1 %. Haemostasis was obtained by manual compression in 52.4 % of the accesses. The primary efficacy outcome occurred in 95.4 % (622/652 patients) and primary safety outcome in 98.6 % (643/652 patients). Major complications included five (0.7 %) retroperitoneal hematomas requiring transfusion; one (0.1 %) common femoral artery pseudoaneurysm successfully treated with US-guided thrombin injection, two cases of intra-procedural distal embolization treated with catheter-directed local thrombolysis and one on-table cardiac arrest necessitating >24 h recovery. No major complication was noted after same-day discharge.ConclusionsDay-case endovascular procedures for the treatment of IC or CLI can be safely and efficiently performed in experienced IR departments of large tertiary hospitals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Wire System and Modified Olive Tip to Facilitate Implantation of Fenestrated TEVAR in Patient with Proximal Descending Aortic Pathology: First Two Cases

Introduction: Although Fenestrated TEVAR (F-TEVAR) has been considered to be a more physiologic approach to treat proximal descending aortic pathology, its application is still limited due to availability, cost and technical difficulties. We introduce a new design of fenestrated stent graft with a new delivery system and successfully performed first in human implantation in two patients, one with an aortic aneurysm and one with an acute aortic dissection. Materials and Methods: The design of these two wires fenestrated stent graft include creation of an additional lumen at the side of the olive tip during manufacture, from which an additional wire can be introduced for a side branch passing into the fenestration, running inside the stent graft and exit the delivery sheath through additional hub. The two wires will facilitate delivery and deployment of the stent graft. One patient with descending aortic aneurysm and another with Stanford B aortic dissection is included in this first in human study. Results: The aneurysm and dissection were completely excluded immediately after the TEVAR. Six month follow up CT showed good position of the stent graft and patent LSA in both patients. In the patient with aortic dissection, expansion of the true lumen and partial thrombosis of the false lumen was seen. Conclusions: This is a report of a two wire system in 2 patients with distal aortic arch pathology demonstrating a good technical and clinical success using pre-cannulated fenestrations through a modified nose cone olive. Level of Evidence: Level 4, report of two cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regulation of dhurrin pathway gene expression during Sorghum bicolor development

Plant defence models evaluate the costs and benefits of resource investments at different stages in the life cycle. Poor understanding of the molecular regulation of defence deployment and remobilization hampers accuracy of the predictions. Cyanogenic glucosides, such as dhurrin are phytoanticipins that release hydrogen cyanide upon bio-activation. In this study, RNA-seq was used to investigate the expression of genes involved in the biosynthesis, bio-activation and recycling of dhurrin in Sorghum bicolor . Genes involved in dhurrin biosynthesis were highly expressed in all young developing vegetative tissues (leaves, leaf sheath, roots, stems), tiller buds and imbibing seeds and showed gene specific peaks of expression in leaves during diel cycles. Genes involved in dhurrin bio-activation were expressed early in organ development with organ-specific expression patterns. Genes involved in recycling were expressed at similar levels in the different organ during development, although post-floral initiation when nutrients are remobilized for grain filling, expression of GSTL1 decreased > tenfold in leaves and NITB2 increased > tenfold in stems. Results are consistent with the establishment of a pre-emptive defence in young tissues and regulated recycling related to organ senescence and increased demand for nitrogen during grain filling. This detailed characterization of the transcriptional regulation of dhurrin biosynthesis, bioactivation and remobilization genes during organ and plant development will aid elucidation of gene regulatory networks and signalling pathways that modulate gene expression and dhurrin levels. In-depth knowledge of dhurrin metabolism could improve the yield, nitrogen use efficiency and stress resilience of Sorghum .

59 BASIC BIOLOGICAL SCIENCES↗

Numerical Modeling of the Thermal State of a Metal–Concrete Container with Spent Nuclear Fuel During Its Transportation

In the work, the authors have presented the procedure and have given results of numerical modeling of the thermal state of a metal–concrete container with spent nuclear fuel during its transportation in a special car. Maximum temperatures of fuel-element sheaths have been determined for several versions of loading of the container with fuel including spent nuclear fuel, with short storage periods.

42 ENGINEERING↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part II: Enforcing the Lorenz Gauge Condition

In a previous paper Christlieb et al. (A particle-in-cell method for plasmas with a generalized momentum formulation, part I: Model formulation, 2024), we developed a new particle-in-cell (PIC) method for the relativistic Vlasov–Maxwell system in which the electromagnetic fields and the equations of motion for the particles were cast in terms of scalar and vector potentials through a Hamiltonian formulation. This new method evolved the potentials under the Lorenz gauge using integral equation methods. New methods to construct spatial derivatives of the potentials that converge at the same rates as the fields were also presented. The new particle method was compared against standard explicit discretizations, including the well-known FDTD-PIC method, for a range of applications involving sheaths and particle beams. Here, this paper extends this new class of methods by focusing on the enforcement the Lorenz gauge condition in both exact and approximate forms using co-located meshes. A time-consistency property of the proposed field solver for the vector potential form of Maxwell’s equations is established, which is shown to preserve the equivalence between the semi-discrete Lorenz gauge condition and the analogous semi-discrete continuity equation. Using this property, we present three methods to enforce a semi-discrete gauge condition. The first method introduces an update for the continuity equation that is consistent with the discretization of the Lorenz gauge condition. Both the finite difference and spectral implementations satisfy this discrete gauge condition to machine precision. The second approach we propose enforces a semi-discrete continuity equation using the boundary integral solution to the field equations. The potential benefit of this approach is that it eliminates spatial derivatives that appear on the particle data, namely the current density, which is often calculated by linear combinations of low-order spline basis functions. This method is ideally suited to boundary integral equation methods that invert multi-dimensional operators without dimensional splitting techniques and will be the subject of future work. The third approach introduces a gauge correcting method that makes direct use of the gauge condition to modify the scalar potential and uses local maps for both the charge and current densities. This results in a gauge error, as the maps do not enforce the continuity equation. The vector potential coming from the current density is taken to be exact, and using the Lorenz gauge, we compute a correction to the scalar potential that makes the two potentials satisfy the gauge condition. This method also enforces the gauge condition to machine precision. We demonstrate two of the proposed methods in the context of periodic domains. Problems defined on bounded domains, including those with complex geometric features remain an ongoing effort. However, this work shows that it is possible to design computationally efficient methods that can effectively enforce the Lorenz gauge condition in a non-staggered PIC formulation.

97 MATHEMATICS AND COMPUTING↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part I: Model Formulation

Here, this paper formulates a new particle-in-cell method for the Vlasov–Maxwell system. Under the Lorenz gauge condition, Maxwell’s equations for the electromagnetic fields can be written as a collection of scalar and vector wave equations. The use of potentials for the fields motivates the adoption of a Hamiltonian formulation for particles that employs the generalized (conjugate) momentum. A notable advantage offered by the Hamiltonian formulation is the elimination of time derivatives in the Lorenz gauge formulation that are required by the standard Newton–Lorentz treatment of the particles. This allows the fields to retain the full time-accuracy guaranteed by the field solver. The resulting updates for particles require only knowledge of the fields and their spatial derivatives. An analytical method for constructing these spatial derivatives is presented that exploits the underlying integral solution used in the field solver for the wave equations. Moreover, these derivatives are demonstrated to converge at the same rate as the fields in both time and space. The Method of Lines Transpose field solver we consider in this work is globally first-order accurate in time and high-order accurate in space (e.g., fourth- and fifth-order) and belongs to a larger class of methods which are unconditionally stable, can address geometry, and leverage $\mathcal {O}(N)$ fast summation methods for efficiency. We demonstrate the method on several well-established benchmark problems on bounded domains, including a plasma sheath as well as a relativistic particle beam. The efficacy of the proposed formulation is established by comparing with a second-order accurate finite-difference time-domain method that employs a leapfrog time advance for particles and a charge conserving map suitable for bounded domains. The new method shows mesh-independent numerical heating properties even in cases where the plasma Debye length is smaller than the grid spacing. This is an important feature of the new method for problems defined on bounded domains, because it permits the use of coarser grids in space in the representation of the fields. Such a capability has significant implications for the simulation of plasmas in bounded domains with complex geometry, where the ratio between the largest and smallest cells can vary significantly. The use of high-order spatial approximations in the new method also means that fewer grid points are required in order to achieve a fixed accuracy. Our results also suggest that the new method can be used with fewer simulation particles per cell compared to the benchmark explicit method, which permits further computational savings.

97 MATHEMATICS AND COMPUTING↗

Ex Situ Spark Plasma Sintering of Short Powder-in-Tube MgB{sub 2} Tapes with Open and Closed Ends

Short powder-in-tube tapes of MgB{sub 2} in the Fe sheath were fabricated by ex situ route from a commercial powder containing some free Mg and MgO impurity phases. The final heat treatment was performed by spark plasma sintering (SPS). Tapes were with open (OT) or closed (CT) endings. Closed endings were made by folding and pressing. The MgB{sub 2} core of the OT sample has shown a higher low-field critical current density, a higher maximum pinning force, a slightly higher disorder, smaller average MgB{sub 2} crystallite size, a weak contact between Fe and MgB{sub 2} core, and more macro-flux jumps. The upper and irreversibility fields were similar for OT and CT samples. In the center of the MgB{sub 2} cores, the detected impurity phase is MgO, while at the interface with Fe, MgB{sub 4} also occurs. Impurity phases found at interface, MgO and MgB{sub 4}, are present in the center of the bulk SPSed samples. Reactions and pinning-force-related parameters are discussed with respect to Mg behavior influenced by condition of endings. It is inferred that the presence of free Mg in the raw MgB{sub 2} powder has an important contribution to observed differences, and its removal or control is recommended.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ex Situ MgB{sub 2} Superconducting Tape with Very High Critical Current Density by Using Low-Temperature Sintering Precursor Powders

Ex situ MgB{sub 2} is usually considered as with lower critical current density (J{sub c}) compared to the in situ one due to much worse inter-granular connectivity. In this work, we reported the fabrication of ex situ MgB{sub 2} superconducting tape without dopants using Monel as sheath materials and Nb as the barrier, which has an excellent J{sub c} of 705 A/mm{sup 2} at 4.2 K under 4 T, almost as same as the in situ MgB{sub 2} wires. Massive and high-quality precursor powders with small grain sizes and quite low oxygen content were sintered at relatively low temperature and short time, 580 {sup ∘}C for 3 h. The effects of heat-treatment conditions and tape thickness on the microstructure and J{sub c} of ex situ MgB{sub 2} tapes were discussed. The results suggested that the improvement of grains-connectivity was responsible to the excellent J{sub c} properties of ex situ MgB{sub 2} tape.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Chemical Bonding and Structural Network of Gold Silicide in Core–Shell Silicon Nanowire

The Au-catalyzed core–shell silicon nanowires (Si-NWs) were synthesized by chemical vapor deposition by using SiH{sub 4} and H{sub 2} precursor gases. The TEM and FTIR studies revealed that the Si-NWs consist of core silicon surrounded by a thick oxide sheath and Au distributed at the a-SiOx/Si interface. The x-ray photoelectron spectroscopy (XPS) was used to study the chemical composition and electronic environments of gold silicide in the a-SiO{sub x}/Si-NWs. The elemental analysis and chemical network of gold silicide of core–shell Si-NWs were explained on the basis of the random atomic distribution of Si, O and Au atoms. The Raman spectra and XRD peak reveal the crystalline core of Si-NWs. The individual contribution to the Au (4d) core orbital was deconvoluted to Au-Si-Au, Au-Si-O, Au-Au, Au-O-Au, Au-O-Si and Au=O/Au-O{sub 2} bonding structure. The analysis shows that the O linked with Si and Au has also contributed to growth of Si-NWs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

3D RNA nanocage for encapsulation and shielding of hydrophobic biomolecules to improve the in vivo biodistribution

Ribonucleic acid (RNA) nanotechnology platforms have the potential of harboring therapeutics for in vivo delivery in disease treatment. However, the nonspecific interaction between the harbored hydrophobic drugs and cells or other components before reaching the diseased site has been an obstacle in drug delivery. In this work, we report an encapsulation strategy to prevent such nonspecific hydrophobic interactions in vitro and in vivo based on a self-assembled three-dimensional (3D) RNA nanocage. By placing an RNA three-way junction (3WJ) in the cavity of the nanocage, the conjugated hydrophobic molecules were specifically positioned within the nanocage, preventing their exposure to the biological environment. The assembly of the nanocages was characterized by native polyacrylamide gel electrophoresis (PAGE), atomic force microscopy (AFM), and cryogenic electron microscopy (cryo-EM) imaging. The stealth effect of the nanocage for hydrophobic molecules in vitro was evaluated by gel electrophoresis, flow cytometry, and confocal microscopy. The in vivo sheathing effect of the nanocage for hydrophobic molecules was assessed by biodistribution profiling in mice. The RNA nanocages with hydrophobic biomolecules underwent faster clearance in liver and spleen in comparison to their counterparts. Therefore, this encapsulation strategy holds promise for in vivo delivery of hydrophobic drugs for disease treatment.

59 BASIC BIOLOGICAL SCIENCES↗

Optimization of a New Aerodynamic Cylindrical FAIMS Device for Small Molecule Analysis

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗