Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Signal transformation approach to fast nanopositioning

High bandwidth, high resolution positioning is a significant enabling tool for nanotechnology. Unfortunately, in a typical nanopositioner operating in closed loop, higher bandwidth results in increased sensitivity to measurement noise and hence reduced resolution. In this article we present a technique that allows high-precision tracking of repetitive, jitter-free reference signals without being constrained by the reduction in measurement noise induced positioning resolution. The technique works exceptionally well for scanners with high enough open loop bandwidth and in the absence of high frequency external disturbances. Both simulation and experimental results are presented to illustrate this concept using a triangular reference signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of condenser microphones under different environmental conditions for accurate speed of sound measurements with acoustic resonators

Condenser microphones are more commonly used and have been extensively modeled and characterized in air at ambient temperature and static pressure. However, several applications of interest for metrology and physical acoustics require to use these transducers in significantly different environmental conditions. Particularly, the extremely accurate determination of the speed of sound in monoatomic gases, which is pursued for a determination of the Boltzmann constant k by an acoustic method, entails the use of condenser microphones mounted within a spherical cavity, over a wide range of static pressures, at the temperature of the triple point of water (273.16 K). To further increase the accuracy achievable in this application, the microphone frequency response and its acoustic input impedance need to be precisely determined over the same static pressure and temperature range. Few previous works examined the influence of static pressure, temperature, and gas composition on the microphone's sensitivity. In this work, the results of relative calibrations of 1/4 in. condenser microphones obtained using an electrostatic actuator technique are presented. The calibrations are performed in pure helium and argon gas at temperatures near 273 K and in the pressure range between 10 and 600 kPa. These experimental results are compared with the predictions of a realistic model available in the literature, finding a remarkable good agreement. The model provides an estimate of the acoustic impedance of 1/4 in. condenser microphones as a function of frequency and static pressure and is used to calculate the corresponding frequency perturbations induced on the normal modes of a spherical cavity when this is filled with helium or argon gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale plasma actuators for improved thrust density

We present a study of the dielectric barrier discharge (DBD) plasma actuators for microscale applications. Traditional macroscale DBD actuators suffer from relatively small actuation effect as characterized by small induced force density and resulting flow velocity. As a remedy we propose microscale plasma actuators that may induce orders of magnitude higher force density. We study the physics of such actuation using a multiscale ionized gas flow code based on the high-fidelity finite-element procedure. First, a two-dimensional volume discharge with nitrogen as a working gas is investigated using a first-principles approach solving coupled system of hydrodynamic plasma equations and Poisson equation for ion density, electron density, and electric field distribution. The quasi-neutral plasma and the sheath regions are identified. As the gap between electrodes is reduced, the sheath structure dominates the plasma region. Second, we simulate a first generation plasma micropump. We solve multiscale plasma-gas interaction inside a two-dimensional cross section of the microscale pump geometry. The result shows that a reasonable mass flow rate can be pumped using a set of small active electrodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energetic neutrals in the cathode sheath of argon direct-current discharges

We recently reported on the direct measurements of the energy distribution of energetic neutrals incident onto the cathode of an argon dc glow discharge [T. Ito and M. A. Cappelli, Appl. Phys. Lett. 90, 101503 (2007)]. In this paper, we provide a more extensive report of the experimental data, as well as direct comparisons to Monte Carlo simulations in which neutral-neutral and ion-neutral collision processes are modeled with differential scattering cross sections. The experimental results, which are limited to relatively small forward angle sampling in our present configuration, are found to be in excellent agreement with Monte Carlo simulations. The simulations reveal that high energy neutrals are striking the cathode with a wide range of angles, while ions are more anisotropic. Therefore, it is difficult to predict the neutral energy distribution with commonly used simple analytical models that do not consider scattering of neutrals within the sheath. We propose the use of an extended analytical model in this paper, which seems to provide reasonable energy distributions over the range of discharge voltage studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beamline I11 at Diamond: A new instrument for high resolution powder diffraction

The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented. Using an in-vacuum undulator for photon production and deploying simple x-ray optics centered around a double-crystal monochromator and a pair of harmonic rejection mirrors, a high brightness and low bandpass x-ray beam is delivered at the sample. To provide fast data collection, 45 Si(111) analyzing crystals and detectors are installed onto a large and high precision diffractometer. High resolution powder diffraction data from standard reference materials of Si, {alpha}-quartz, and LaB{sub 6} are used to characterize instrumental performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A planar-type surface-wave plasma source with a subwavelength diffraction grating inclusion for large-area plasma applications

The electromagnetic wave through the subwavelength diffraction grating can be largely absorbed by surface-wave plasmas (SWPs). A SWP source is built with two slot-array antennas element. Due to the dissipation of surface waves in overdense plasmas, this source can provide remarkable discharge efficiency of 4.4 cm{sup 2}/W experimentally and 96% of incident power numerically. When the applied power as low as 200 W is supplied to the SWP source, a homogeneous plasma with the uniform area up to 14x36 cm{sup 2} and the plasma density up to 1.04x10{sup 18} m{sup -3} is generated under the quartz slab. By varying the incident power and gas pressure, the parameter of plasmas can be easily controlled without density jumping. Moreover, the characters of bi-Maxwellian electron energy distribution prove that our SWP source yield plasmas by surface heating actually. These excellent performances make the proposed source meet the requirements in large-area plasma processing and also give its advices for plasmas heating in next meter-size SWP sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma uniformity and phase-controlled etching in a very high frequency capacitive discharge

The influence of controlled phase shift between very high frequency (100 MHz) voltages applied to the powered electrodes on the plasma uniformity and etch rate was studied in a capacitive triode-type reactor. Radial profiles of plasma optical emission were measured as a function of the phase shift in process (C{sub 4}F{sub 8}/O{sub 2}/Ar) plasma with the low frequency bias power both turned off and on. Radial profiles of KrF photoresist etch rate over a 300 mm wafer were obtained in the same conditions (with the bias power turned on). Besides, plasma density at the wafer center and edge was measured versus the phase shift in pure Ar plasma. It occurred that all measured characteristics strongly depend on the phase shift and correlate with each other. It has been shown that the phase-shift control can considerably improve both the plasma and etch-rate uniformity in very high-frequency capacitive reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonreciprocity in circular magnetoplasma-filled waveguides above the cyclotron frequency

The electromagnetic behavior of a circular perfect electric conductor waveguide with various magnetoplasma filling configurations has been investigated near the cyclotron resonance region at 77 K with longitudinal magnetic bias. Faraday rotation in the forward and reverse directions along with the waveguide geometry effect provided the nonreciprocal attenuation to design an isolator for frequencies up to the terahertz region. Based on the finite element method, two-dimensional eigenvalue as well as three-dimensional numerical simulations are provided to illustrate the phenomena. Unprecedented performance was attained for the coaxial configuration in terms of the bias-to-frequency ratio. Other configurations were found to have some nonreciprocity as well.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of plasma uniformity in a capacitive discharge using two very high frequency power sources

Very high frequency (VHF) capacitively coupled plasma (CCP) discharges are being employed for dielectric etching due to VHF's various benefits including low plasma potential, high electron density, and controllable dissociation. If the plasma is generated using multiple VHF sources, one can expect that the interaction between the sources can be important in determining the plasma characteristics. The effects of VHF mixing on plasma characteristics, especially its spatial profile, are investigated using both computational modeling and diagnostic experiments. The two-dimensional plasma model includes the full set of Maxwell equations in their potential formulation. The plasma simulation results show that electron density peaks at the center of the chamber at 180 MHz due to the standing electromagnetic wave. Electrostatic effects at the electrode edges tend to get stronger at lower VHFs such as 60 MHz. When the two rf sources are used simultaneously and power at 60 MHz is gradually increased, the ion flux becomes uniform and then transitions to peak at electrode edge. These results are corroborated by Langmuir probe measurements of ion saturation current. VHF mixing is therefore an effective method for dynamically controlling plasma uniformity. The plasma is stronger and more confined when the 60 MHz source is connected to the smaller bottom electrode compared to the top electrode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Space-charge waves on relativistic elliptic electron beams

This paper reports on results of a small-signal analysis of space-charge waves on a relativistic elliptic electron beam immersed in a strong axial magnet field in a perfectly conducting tunnel with an elliptic cross section. A dispersion relation for the space-charge waves is derived analytically. A computer code, elliptic-beam small signal, is developed and used in studies of the dispersion characteristics of fast- and slow-space-charge waves on relativistic elliptic electron beams. Applications of the theory in elliptic-beam klystrons are discussed.

43 PARTICLE ACCELERATORS↗

Effect of radio frequency discharge power on dusty plasma parameters

The parameters of a two-dimensional dusty plasma consisting of six, 9 mum diameter particles trapped inside a radio frequency (rf) plasma sheath have been measured as a function of rf power in a 13.5 mtorr (1.8 Pa) argon discharge. The center-of-mass and breathing frequencies are found by projecting the cluster's Brownian motion onto the associated normal mode. The center-of-mass frequency (i.e., radial confinement) is insensitive to rf power. The Debye shielding parameter kappa, as found from the breathing frequency, increases from approx =0.5 to 2 as the square root of rf power. The Debye length decreases from approx =2.7 to 0.7 mm as the inverse of the square root of rf power. The average particle charge qapprox =-17 000e is effectively independent of rf power. These results are consistent with an electron temperature that is independent of rf power and an ion density that is directly proportional to rf power, where the Debye length is determined by the ion density in combination with the electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A comparative study of single and double pulse laser induced breakdown spectroscopy

A comparative study of single and double pulse laser induced breakdown spectroscopy (LIBS) using the fundamental (1064 nm) and the second harmonics (532 nm) of Nd:YAG lasers is presented. The double pulse collinear configuration yields more than three hundred times signal enhancement in the singly ionized aluminum lines as compared to the single pulse LIBS spectrum. The effect of interpulse delay between the two laser pulses and the laser pulses energies ratio in the double pulse spectrum are studied. A comparison of variations of plasma parameters along the plume axis in the single and the double pulse has also been studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental scaling law for mass ablation rate from a Sn plasma generated by a 1064 nm laser

The ablation depth in planar Sn targets irradiated with a pulsed 1064 nm laser was investigated over laser intensities from 3x10{sup 11} to 2x10{sup 12} W/cm{sup 2}. The ablation depth was measured by irradiating a thin layer of Sn evaporated onto a Si wafer, and looking for signatures of Si ions in the expanding plasma with spectroscopic and particle diagnostics. It was found that ablation depth scales with laser intensity to the (5/9)th power, which is consistent with analytical models of steady-state laser ablation, as well as empirical formulae from previous studies of mass ablation rate in overlapping parameter space. In addition, the scaling of mass ablation rate with atomic number of the target as given by empirical formulae in previous studies using targets such as C and Al, are shown to remain valid for the higher atomic number of the target (Z=50) used in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow control around a circular cylinder using pulsed dielectric barrier discharge surface plasma

Dielectric barrier discharge (DBD) plasma actuators have been used to control the flow around a circular cylinder at Re=15 000, where the near-wake structure was studied using time-resolved particle image velocimetry with simultaneous measurements of the dynamic lift and drag forces. It was shown that the vortex shedding was suppressed when the surface plasma placed near the natural separation point was activated in a pulsed mode at nondimensional frequency, f{sub p}{sup +}, above 0.6 with a force coefficient, C{sub p}, greater than 0.05%. Plasma actuator performance on flow control was summarized by mapping the changes in drag and lift fluctuations as a function of the forcing frequency and the force coefficient. They showed that more than 70% reduction in lift fluctuations was obtained with up to 32% drag reduction at f{sub p}{sup +}=2.0 and C{sub p}=0.32%. Here, narrowing of the wake was observed as the plasma promoted shear-layer roll-ups at the forcing frequency. This, however, did not affect the shear layer on the opposite side of the wake. At nondimensional forcing frequencies less than 0.6, the vortex shedding locked onto a multiple of the plasma frequency to amplify the wake oscillations. This caused more than 85% increase in lift fluctuations with 8% drag increase at f{sub p}{sup +}=0.2 and C{sub p}=0.01%. The efficiency of flow control using DBD plasma was found to be 1%-2% for drag reduction while around 6% for drag increase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined holographic-mechanical optical tweezers: Construction, optimization, and calibration

A spatial light modulator (SLM) and a pair of galvanometer-mounted mirrors (GMM) were combined into an optical tweezers setup. This provides great flexibility as the SLM creates an array of traps, which can be moved smoothly and quickly with the GMM. To optimize performance, the effect of the incidence angle on the SLM with respect to phase and intensity response was investigated. Although it is common to use the SLM at an incidence angle of 45 deg., smaller angles give a full 2{pi} phase shift and an output intensity which is less dependent on the magnitude of the phase shift. The traps were calibrated using an active oscillatory technique and a passive probability distribution method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collinear interferometer with variable delay for carrier-envelope offset frequency measurement

We demonstrate a novel scheme for measuring the carrier-envelope offset frequency in a femtosecond optical frequency comb. Our method is based on a common-path interferometer with a calcite Babinet-Soleil compensator employed to control the delay between the two interfering beams of pulses. The large delay range (up to 8 ps) of our device is sufficient for systems that rely on spectral broadening in microstructured fibers. We show an experimental proof that the stability of a common-path arrangement is superior to that of the standard interferometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Knot undulator to generate linearly polarized photons with low on-axis power density

Heat load on beamline optics is a serious obstacle for devices designed to generate pure linearly polarized photons in third generation synchrotron radiation facilities. For permanent magnet undulators, this problem can be overcome by implementing a figure-eight design configuration. As yet there has been no good method to tackle this problem for electromagnetic elliptical undulators. Here, a novel design and operational mode is suggested, which can generate pure linearly polarized photons with very low on-axis heat load. Additionally, the minimum photon energy capability of linearly polarized photons can be significantly extended by this method.

43 PARTICLE ACCELERATORS↗

High-Order Harmonic And Fast Ion Generation In High Intensity Laser-Solid Interactions

Experiments on high-order harmonic generation and ion acceleration are performed with the new installed 100 TW, 25 fs laser in Saclay (UHI100). These experiments require a very high laser pulse contrast. The suppression of prepulse energy is achieved by using a double plasma mirror, which results in a contrast of 10{sup 13}.

43 PARTICLE ACCELERATORS↗