Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Two-zone stratified wetwell model development and implementation for RELAP-7

The Reactor Core Isolation Cooling (RCIC) system consists of a turbine, pump and wetwell and is used in many US Boiling Water Reactors (BWRs) as an important heat removal system. The wetwell is a major heat sink within containment. Experimental investigations have shown that thermal stratification may occur in the wetwell during RCIC operation. Current systems-level analysis codes lack stratified wetwell models. Here, this paper describes the development of a stratified wetwell model for the RELAP-7 code. This paper uses a simple two-zone model for the wetwell water that can capture thermal stratification. This model assumes that a buoyant plume transports heat and mass from the steam injection site to the upper water zone. The buoyant plume assumption requires that steam is injected at a low enough rate so it adds negligible momentum. Model validation against experimental data shows similar trends of temperature field development in the suppression pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grid-Scale Electricity Storage at Lowest Possible Cost Enabled by Pumped Heat Electricity Storage (Final Report)

Grid-scale energy storage technologies that can provide greater than 10 hours of electricity at full power address a critical need for full penetration of renewables on electricity grids worldwide, minimize renewable curtailment, and maximize grid security and reliability. Pumped Heat Energy Storage (PHES) systems can store energy thermally in any location at the low costs necessary for displacing fossil fuels, reducing foreign fuel imports, and reducing emissions to maintain the energy security of the United States. The award allowed Southwest Research Institute® (SwRI®) and Malta, Inc. (Malta) to advance the PHES concept to a proof-of-concept demonstration for a kW-scale system. The project focused on system operation and integration. The main project objectives were: 1. Address first implementation challenges 2. Explore system control strategies and operation 3. Translate lessons learned to the full-scale system Through these objectives the project completes a first demonstration of this technology and reduces the technical risk associated with a full-scale system.

25 ENERGY STORAGE↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Stainless Steel NaK-Cooled Circuit (SNaKC) Fabrication and Assembly

An actively pumped Stainless Steel NaK Circuit (SNaKC) has been designed and fabricated by the Early Flight Fission Test Facility (EFF-TF) team at NASA's Marshall Space Flight Center. This circuit uses the eutectic mixture of sodium and potassium (NaK) as the working fluid building upon the experience and accomplishments of the SNAP reactor program from the late 1960's The SNaKC enables valuable experience and liquid metal test capability to be gained toward the goal of designing and building an affordable surface power reactor. The basic circuit components include a simulated reactor core a NaK to gas heat exchanger, an electromagnetic (EM) liquid metal pump, a liquid metal flow meter, an expansion reservoir and a drain/fill reservoir To maintain an oxygen free environment in the presence of NaK, an argon system is utilized. A helium and nitrogen system are utilized for core, pump, and heat exchanger operation. An additional rest section is available to enable special component testing m an elevated temperature actively pumped liquid metal environment. This paper summarizes the physical build of the SNaKC the gas and pressurization systems, vacuum systems, as well as instrumentation and control methods.

Godfroy, Thomas J.↗

Pump/Control System Minimum Operating Cost Testing

A preliminary evaluation of pump performance was initiated to determine the efficiencies of an arbitrary group of small pumps. Trends in factors affecting energy usage in typical prime movers which might be used in liquid transport solar systems were assessed. Comparisons of centrifugal pump efficiencies were made from one manufacturer to another. Tests were also made on two positive-displacement pumps and comparisons with centrifugal pumps were observed.

Source record↗

Characterizing the nonequilibrium response of FeRh thin films using time-domain thermoreflectance

Time-domain thermoreflectance (TDTR) characterization of FeRh throughout its first-order antiferromagnetic (AF) to ferromagnetic (FM) transition shows that the transient reflectance ΔR⁡(t)/R strongly depends on the magnetic order of the sample. Using TDTR, which uses optical pulses to induce small temperature excursions, we have found that Δ⁢R⁡(t)/R of the AF phase exhibits a large negative response, while the response of the FM phase is positive. This magnetic phase sensitivity has allowed us to study the transient response of both the AF and FM phases to the pump-pulse excitation and the mixed phase of the material. These results are significant since the ultrafast properties of antiferromagnetic materials and mixed antiferromagnetic and ferromagnetic materials are difficult to detect using other conventional techniques. We have found that the AF phase exhibits a strong subpicosecond decaying signal not observed in the FM phase. The magnetic phase dependence of the sign of Δ⁢R⁡(t)/R is qualitatively explained using the results of ab initio density functional theory calculations. Using the two-temperature model, we found that the change in the thermalization time across the transition is caused by differences in both the electronic heat capacity and the electron-phonon coupling factor of the AF and FM phases. The electron-phonon coupling constant in the AF phase is also determined using the two-temperature model conducted using the ntmpy code package. For the FM phase, we provide boundaries for the magnitude of the electron-phonon coupling factor for the FM phase. Finally, these results indicate that TDTR can be used to study the transient properties of magnetic materials that are otherwise challenging to probe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Two phase pumping of cryogenic propellants

Two-phase cryogenic propellant pumping techniques developed during the past 5 years are discussed. During this period the theory of two-phase pumping of hydrogen was developed into an operational technique that can result in significant benefits to space vehicle propulsion systems. Using two-phase pumping techniques, zero LH2 tank net positive suction head (NPSH) was demonstrated on turbopump and rocket engine firings, and limited experimental results show that two-phase pumping of liquid oxygen is feasible. Design techniques were developed for improving the two-phase pumping capability of inducers.

H P Stinson↗

Solar space-heating system--Yosemite National Park, California

A 12 months performance of Visitors Center installation suffered from low insolation, high energy dissipation, and equipment breakdown. System has 980 square feet of liquid flat-plate collectors, water energy storage, 4-mode control, heat exchangers, pumps, and plumbing. Design expected system to supply over 50 percent of annual heating demand, but only 109 million Btu were conserved.

Source record↗

Cryogenic Propellant Tank Drain Simulation with a Stratified Ullage Nodal Model

Cryogenic propellant tank pressurization systems maintain tank pressure within specified limits to comply with propellant thermodynamic and tank structural design requirements. Many pump-fed cryogenic liquid propulsion systems control tank pressure using an autogenous pressurization system. Autogenous pressurization systems vaporize and heat propellant to produce the pressurant gas delivered to the tank. While autogenous pressurization systems eliminate the need for a separate pressurant gas storage and delivery system, they couple pressurant mass requirements to propellant mass requirements. Accurate prediction of autogenous pressurant mass during propellant drain is essential in optimizing cryogenic propellant tank designs.

Richard G Hibbs↗

Structure of multilayered Cr(Al)N/SiO{sub x} nanocomposite coatings fabricated by differential pumping co-sputtering

A Cr(Al)N/38 vol. % SiO{sub x} hard coating was prepared on a (001) Si substrate at 250 °C in a differential pumping co-sputtering system, which has two chambers for radio frequency (RF) sputtering and a substrate holder rotating on the chambers. The composite coating was grown by alternate sputter-depositions from CrAl and SiO{sub 2} targets with flows of N{sub 2}+Ar and Ar at RF powers of 200 and 75 W, respectively, on transition layers grown on the substrate. Analytical electron microscopy reveled that the Cr(Al)N/SiO{sub x} coating had a multilayered structure of Cr(Al)N crystal layers ∼1.6 nm thick and two-dimensionally dispersed amorphous silicon oxide (a-SiO{sub x}) particles with sizes of ∼1 nm or less. The a-SiO{sub x} particles were enclosed with the Cr(Al)N layers. The coating had a low indentation hardness of ∼25 GPa at room temperature, due to a high oxide fraction of 38 vol. % and a low substrate rotational speed of 1 rpm. Faster rotation and lower oxide fraction would make a-SiO{sub x} particles smaller, resulting in the formation of Cr(Al)N crystal including the very fine a-SiO{sub x} particles with small number density. They would work as obstacles for the lattice deformation of the Cr(Al)N crystals. We have fabricated a superhard coating of Cr(Al)N/17 vol. % SiO{sub x} with a hardness of 46 GPa prepared at 12 rpm.

36 MATERIALS SCIENCE↗

Liquid Metal Pump Technologies for Nuclear Surface Power

Multiple liquid metal pump options are reviewed for the purpose of determining the technologies that are best suited for inclusion in a nuclear reactor thermal simulator intended to rest prototypical space nuclear surface power system components. Conduction, induction and thermoelectric electromagnetic pumps are evaluated based on their performance characteristics and the technical issues associated with incorporation into a reactor system. A thermoelectric electromagnetic pump is selected as the best option for use in NASA-MSFC's Fission Surface Power-Primary Test Circuit reactor simulator based on its relative simplicity, low power supply mass penalty, flight heritage, and the promise of increased pump efficiency over those earlier pump designs through the use of skutterudite thermoelectric elements.

Polzin, Kurt A.↗

Solar assisted heat pump on air collectors: A simulation tool

The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

14 SOLAR ENERGY↗

Method and system for carbon dioxide energy storage in a power generation system

A CO2 energy storage system includes a storage tank that stores a CO2 slurry, including dry ice and liquid CO2, at CO2 triple point temperature and pressure conditions. The storage system also includes a first pump coupled in flow communication with the storage tank. The first pump is configured to receive the CO2 slurry from the storage tank and to increase a pressure of the CO2 slurry to a pressure above the CO2 triple point pressure. The energy storage system further includes a contactor coupled in flow communication with the first pump. The contactor is configured to receive the high pressure CO2 slurry from the pump and to receive a first flow of gaseous CO2 at a pressure above the CO2 triple point pressure. The gaseous CO2 is contacted and then condensed by the melting dry ice in the slurry to generate liquid CO2.

25 ENERGY STORAGE↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 8000 rpm (838 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗

The noncavitating performance and life of a small vane-type positive displacement pump in liquid hydrogen

The low flow rate and high head rise requirements of hydrogen/oxygen auxiliary propulsion systems make the application of centrifugal pumps difficult. Positive displacement pumps are well-suited for these flow conditions, but little is known about their performance and life characteristics in liquid hydrogen. An experimental and analytical investigation was conducted to determine the performance and life characteristics of a vane-type, positive displacement pump. In the experimental part of this effort, mass flow rate and shaft torque were determined as functions of shaft speed and pump pressure rise. Since liquid hydrogen offers little lubrication in a rubbing situation, pump life is an issue. During the life test, the pump was operated intermittently for 10 hr at the steady-state point of 0.074 lbm/sec (0.03 kg/sec) flow rate, 3000 psid (2.07 MPa) pressure rise, and 9000 rpm (938 rad/sec) shaft speed. Pump performance was monitored during the life test series and the results indicated no loss in performance. Material loss from the vanes was recorded and wear of the other components was documented. In the analytical part of this effort, a comprehensive pump performance analysis computer code, developed in-house, was used to predict pump performance. The results of the experimental investigation are presented and compared with the results of the analysis. Results of the life test are also presented.

Ulbricht, T. E.↗