Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Physical processes in Comet Kohoutek

Observational results are brought together to establish the mass loss of Comet Kohoutek (1973 XII) in H2O, solid particles, and other molecules. The production rate of molecules is seen to have flattened prior to peaking near perihelion passage, and then fell below the rate for the incoming branch of the orbit. The total mass loss was about 10 to the 14th power gm. All abundances are consistent with a clathrate-dominant form of water. Comparison of the sizes of the nucleus as calculated from photometry and the rate of water loss requires that either an unrealistically high albedo be assumed or that only a portion of the nucleus was covered by water, in contrast with previous expectations for a new and probable first-passage comet. Moreover, if the preperihelion estimates of the nuclear brightness are rejected as being contaminated, the resulting values indicate an ice-covered nucleus with a radius of 2.1 km.

Odell, C. R.↗

Testing of an Annular Linear Induction Pump for the Fission Surface Power Technology Demonstration Unit

Results of performance testing of an annular linear induction pump that has been designed for integration into a fission surface power technology demonstration unit are presented. The pump electromagnetically pushes liquid metal (NaK) through a specially-designed apparatus that permits quantification of pump performance over a range of operating conditions. Testing was conducted for frequencies of 40, 55, and 70 Hz, liquid metal temperatures of 125, 325, and 525 C, and input voltages from 30 to 120 V. Pump performance spanned a range of flow rates from roughly 0.3 to 3.1 L/s (4.8 to 49 gpm), and pressure heads of <1 to 104 kPa (<0.15 to 15 psi). The maximum efficiency measured during testing was 5.4%. At the technology demonstration unit operating temperature of 525 C the pump operated over a narrower envelope, with flow rates from 0.3 to 2.75 L/s (4.8 to 43.6 gpm), developed pressure heads from <1 to 55 kPa (<0.15 to 8 psi), and a maximum efficiency of 3.5%. The pump was supplied with three-phase power at 40 and 55 Hz using a variable-frequency motor drive, while power at 55 and 70 Hz was supplied using a variable-frequency power supply. Measured performance of the pump at 55 Hz using either supply exhibited good quantitative agreement. For a given temperature, the peak in efficiency occurred at different flow rates as the frequency was changed, but the maximum value of efficiency was relative insensitive within 0.3% over the frequency range tested, including a scan from 45 to 78 Hz. The objectives of the FSP technology project are as follows:5 • Develop FSP concepts that meet expected surface power requirements at reasonable cost with added benefits over other options. • Establish a nonnuclear hardware-based technical foundation for FSP design concepts to reduce overall development risk. • Reduce the cost uncertainties for FSP and establish greater credibility for flight system cost estimates. • Generate the key nonnuclear products to allow Agency decision makers to consider FSP as a viable option for potential future flight development. The pump must be compatible with the liquid NaK coolant and have adequate performance to enable a viable flight system. Idaho National Laboratory (INL) was tasked with the design and fabrication of an ALIP suitable for the FSP reference mission. Under the program, a quarter-scale FSP technology demonstration is under construction to test the end-to-end conversion of simulated nuclear thermal power to usable electrical power intended to raise the entire FSP system to Technology Readiness Level 6. An ALIP for this TDU was fabricated under the direction of the INL and shipped to NASA Marshall Space Flight Center (MSFC) for testing at representative operating conditions. This pump was designed to meet the requirements of the TDU experiment. The ALIP test circuit (ATC) at MSFC, previously used to conduct performance evaluation on another ALIP6 was used to test the present TDU pump for the FSP Technology Development program.

Polzin, K. A.↗

The Origin and Evolution of Saturn's 2011-2012 Stratospheric Vortex

The planet-encircling springtime storm in Saturn's troposphere (December 2010-July 2011, Fletcher, L.N. et al. [2011]. Science 332, 1413-1414; Sánchez-Lavega, A. et al. [2011]. Nature 475, 71-74; Fischer, G. et al. [2011]. Nature 475, 75-77) produced dramatic perturbations to stratospheric temperatures, winds and composition at mbar pressures that persisted long after the tropospheric disturbance had abated. Thermal infrared (IR) spectroscopy from the Cassini Composite Infrared Spectrometer (CIRS), supported by ground-based IR imaging from the VISIR instrument on the Very Large Telescope and the MIRSI instrument on NASA's IRTF, is used to track the evolution of a large, hot stratospheric anticyclone between January 2011 and March 2012. The evolutionary sequence can be divided into three phases: (I) the formation and intensification of two distinct warm airmasses near 0.5 mbar between 25 and 35degN (B1 and B2) between January-April 2011, moving westward with different zonal velocities, B1 residing directly above the convective tropospheric storm head; (II) the merging of the warm airmasses to form the large single 'stratospheric beacon' near 40degN (B0) between April and June 2011, disassociated from the storm head and at a higher pressure (2 mbar) than the original beacons, a downward shift of 1.4 scale heights (approximately 85 km) post-merger; and (III) the mature phase characterised by slow cooling (0.11 +/- 0.01 K/day) and longitudinal shrinkage of the anticyclone since July 2011. Peak temperatures of 221.6 +/- 1.4 K at 2 mbar were measured on May 5th 2011 immediately after the merger, some 80 K warmer than the quiescent surroundings. From July 2011 to the time of writing, B0 remained as a long-lived stable stratospheric phenomenon at 2 mbar, moving west with a near-constant velocity of 2.70 +/- 0.04 deg/day (24.5 +/- 0.4 m/s at 40degN relative to System III longitudes). No perturbations to visible clouds and hazes were detected during this period. With no direct tracers of motion in the stratosphere, we use thermal windshear calculations to estimate clockwise peripheral velocities of 200-400 m/s at 2 mbar around B0. The peripheral velocities of the two original airmasses were smaller (70-140 m/s). In August 2011, the size of the vortex as defined by the peripheral collar was 65deg longitude (50,000 km in diameter) and 25deg latitude. Stratospheric acetylene (C2H2) was uniformly enhanced by a factor of three within the vortex, whereas ethane (C2H6) remained unaffected. The passage of B0 generated a new band of warm stratospheric emission at 0.5 mbar at its northern edge, and there are hints of warm stratospheric structures associated with the beacons at higher altitudes (p < 0.1 mbar) than can be reliably observed by CIRS nadir spectroscopy. Analysis of the zonal windshear suggests that Rossby wave perturbations from the convective storm could have propagated vertically into the stratosphere at this point in Saturn's seasonal cycle, one possible source of energy for the formation of these stratospheric anticyclones.

evolution↗

Performance estimation of resonance-enhanced dual-buoy wave energy converter using coupled time-domain simulation

This article presents the modeling methodology and performance evaluation of the resonance-enhanced dual-buoy WEC (Wave Energy Converter) by HEM (hydrodynamic & electro-magnetic) fully-coupled-dynamics time-domain-simulation program. The numerical results are systematically compared with the authors’ 1/6-scale experiment. With a direct-drive linear generator, the WEC consists of dual floating cylinders and a moon-pool between the cylinders, which can utilize three resonance phenomena from moon-pool dynamics as well as heave motions of inner and outer buoys. The contact and friction between the two buoys observed in the experiment are also properly modeled in the time-domain simulation by the Coulomb-friction model. Moon-pool resonance peaks significantly exaggerated in linear potential theory are empirically adjusted through comparisons with measured values. A systematic comparative study between the simulations and experiments with and without PTO (power-take-off) is conducted, and the relative heave displacements/velocities and power outputs are well matched. Then, parametric studies are carried out with the simulation program to determine optimum generator parameters. The performance with various wave conditions is also assessed.

16 TIDAL AND WAVE POWER↗

Estimates of Heat Shielding Requirements for Saturn Probe Missions

Entry trajectories, decelerations, heating and heat shielding requirements of probes entering the atmosphere of Saturn at relative entry velocities ranging from 26.5 - 33.0 km/sec were studied. Much of the Galileo Jupiter probe technology was applicable to these outer planet probes; therefore, the same configuration was used. A wide range entry flight path angles were used in the trajectory analysis in order to satisfy the complete range of arrival conditions and trajectory requirements. Various entry probe sizes and a range of entry masses from 32 - 258 kg were considered. The carbon phenolic heat shield material used on the Galileo and the successful Pioneer-Venus probes was selected. Turbulent boundary layer convection dominated the heating of the Saturn probes; radiative heating was negligible by comparison at the entry velocities considered. The peak heating rates were found to be about 4 kW per square centimeter, or approximately 17% of the Galileo probe's expected maximum value. The forebody heat shield mass fractions for the Saturn probes were found to vary from about 0.18 to 0.28. By comparison, the Pioneer-Venus probes' heat shield mass fractions ranged from 0.10 to 0.13 and the Galileo probe's forebody value is 0.43.

Wercinski, P.↗

Thermal Protection System to Enable Ice Giant Aerocapture Mission for Delivering Both an Orbiter and an In Situ Probe

The Ice Giants have been identified as high priority science destinations in the last Decadal Survey [1] and could benefit from aerocapture as the primary method for orbit insertion [2]. A mass-efficient aerocapture system will enable the delivery of an orbiter along with an atmospheric probe (for in situ measurements to anchor global data collected by the orbiter) and possibly a lander at Triton [3]. Aerocapture could be executed either using low L/D rigid aeroshell with lift modulation (LMA) [4] or using deployable aeroshell using drag modulation (DMA) [3]. Nearly two decades ago, a NASA-funded team performed Neptune-Triton aerocapture studies with a mid-L/D lifting configuration [5] for achieving orbit using LMA. This study showed aerocapture challenges. Due to very high peak entry conditions combined with very high heat-load, a suite of TPS materials was required and this suite was deemed problematic from a qualification perspective, due test facility limitations. In the past 20 years, progress made in GN&C for lift-guided entry missions such as MSL, Orion EFT1, Mars 2020 and the upcoming Artemis missions, and the expertise in blunt body aerodynamics at large scale (~ 5m) has led the EDL community to conclude that aerocapture is a “go do” engineering activity and most technologies are in hand to propose missions with aerocapture [6] [7]. Aerocapture using DMA, currently in development, is an option for Ice Giant Missions. While DMA is simpler in some sense, due to ballistic entry and no need for lift-guided maneuvering, it has challenges and it’s maturity is lower. LMA and DMA both require one or more ablative Thermal Protection System (TPS) materials for the rigid aeroshell element. The ablative TPS needs to be robust and mass efficient due to the high heat loads and size of the rigid aeroshell. Currently, there are capable ablative thermal protection materials, e.g., Heatshield for Extreme Entry Environments Technology (HEEET), 3-D woven Mid-Density Carbon- Phenolic (3MDCP), and PICA (Phenolic-Impregnated Carbon Ablator) that are mature, i.e., at TRL 6 or higher. NASA also invested in Conformal PICA that was matured to TRL 5. Our goal is to evaluate the applicability of high TRL TPS and consider other design options. We first establish bounding aerocapture trajectories for a wide range of arrival conditions and the associated aerothermal environment. Based on the environments, we then determine the predicted TPS mass for the aeroshell [4]. In this presentation, we will outline the process by which we establish bounding aerocapture trajectories for hyperbolic excess velocities ranging from 27 km/s to 35 km/s, which are shown to be a range of velocities that can reduce the trip time from ~14 years to 8 years. The above velocity range translates to ~12 km/s to ~24 km/s arrival velocities at the planetary entry interface [2]. The velocity reduction required to achieve orbit ranges between ~2.5 km/s to 9.5 km/s for both Neptune and Triton. Propulsive insertion alone, due to the amount of fuel required to achieve the required velocity reduction, limits the science returned [2]. We establish the bounding aerocapture trajectories for a low L/D (~ 0.4) configuration for three different ballistic coefficients. The ballistic coefficient range is determined from three different aeroshell diameters of 3m, 4m and 5m and with an entry system mass of 2200 kg. With the above range of design parameters, we then determine conservative/bounding estimates of aerothermal environments by using a combination of CFD simulations and stagnation point heating estimates [7]. This engineering approach allows us to first assess the TPS need vs. TPS capability and determine the applicability of existing TPS. Once an applicable suite of TPS is determined, the TPS thickness and mass are computed. We show that the TPS mass fraction can be as low as 5% to as high as 20%, depending on total trip time reduction and other design parameters for a range of TPS. This is a large range for TPS mass fraction. We show PICA and HEEET can indeed enable aerocapture missions, but the missions incur a mass penalty. TPS mass savings, can be further reduced with the use of conformal PICA. Advancing the development of Conformal PICA to make it robust across the entire aerothermal environment (peak heat-flux, pressure and shear) range will result in TPS mass fractions of < 10% for Ice Giant aerocapture missions such as the Neptune-Triton mission. Aerocapture allows for not only shortening the trip time but enables larger mass to be placed in orbit. Furthermore, probes deployed from orbit will benefit in reduced entry environments allowing for a lower risk TPS implementation as compared to mission designs where the probe is released prior to orbit insertion. One of the challenges for the Ice Giant community is to ensure mission designs that maximize science and allow flexibility in the placement of the entry probe. The traditional approach to release the probe ahead of the orbiter may not optimize returned science. In this presentation, we will make the case for mature TPS such as HEEET and PICA. While these materials can enable aerocapture missions, completing the development of conformal PICA and extending Conformal PICA to be more robust, will have significant impact to TPS mass efficiency and significantly enhance science return for future Gas- and Ice-Giant missions.

E Venkatapathy↗

Convective Vortices and Dust Devils Detected and Characterized by Mars 2020

Abstract We characterize vortex and dust devils (DDs) at Jezero from pressure and winds obtained with the Mars Environmental Dynamics Analyzer (MEDA) instrument on Mars 2020 over 415 Martian days (sols) ( Ls = 6°–213°). Vortices are abundant (4.9 per sol with pressure drops >0.5 Pa correcting from gaps in coverage) and they peak at noon. At least one in every five vortices carries dust, and 75% of all vortices with Δ p > 2.0 Pa are dusty. Seasonal variability was small but DDs were abundant during a dust storm ( Ls = 152°–156°). Vortices are more frequent and intense over terrains with lower thermal inertia favoring high daytime surface‐to‐air temperature gradients. We fit measurements of winds and pressure during DD encounters to models of vortices. We obtain vortex diameters that range from 5 to 135 m with a mean of 20 m, and from the frequency of close encounters we estimate a DD activity of 2.0–3.0 DDs km −2 sol −1 . A comparison of MEDA observations with a Large Eddy Simulation of Jezero at Ls = 45° produces a similar result. Three 100‐m size DDs passed within 30 m of the rover from what we estimate that the activity of DDs with diameters >100 m is 0.1 DDs km −2 sol −1 , implying that dust lifting is dominated by the largest vortices in Jezero. At least one vortex had a central pressure drop of 9.0 Pa and internal winds of 25 ms −1 . The MEDA wind sensors were partially damaged during two DD encounters whose characteristics we elaborate in detail.

Hueso, R.↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing the gravitational instability hypothesis?

We challenge a widely accepted assumption of observational cosmology: that successful reconstruction of observed galaxy density fields from measured galaxy velocity fields (or vice versa), using the methods of gravitational instability theory, implies that the observed large-scale structures and large-scale flows were produced by the action of gravity. This assumption is false, in that there exist nongravitational theories that pass the reconstruction tests and gravitational theories with certain forms of biased galaxy formation that fail them. Gravitational instability theory predicts specific correlations between large-scale velocity and mass density fields, but the same correlations arise in any model where (a) structures in the galaxy distribution grow from homogeneous initial conditions in a way that satisfies the continuity equation, and (b) the present-day velocity field is irrotational and proportional to the time-averaged velocity field. We demonstrate these assertions using analytical arguments and N-body simulations. If large-scale structure is formed by gravitational instability, then the ratio of the galaxy density contrast to the divergence of the velocity field yields an estimate of the density parameter Omega (or, more generally, an estimate of beta identically equal to Omega(exp 0.6)/b, where b is an assumed constant of proportionality between galaxy and mass density fluctuations. In nongravitational scenarios, the values of Omega or beta estimated in this way may fail to represent the true cosmological values. However, even if nongravitational forces initiate and shape the growth of structure, gravitationally induced accelerations can dominate the velocity field at late times, long after the action of any nongravitational impulses. The estimated beta approaches the true value in such cases, and in our numerical simulations the estimated beta values are reasonably accurate for both gravitational and nongravitational models. Reconstruction tests that show correlations between galaxy density and velocity fields can rule out some physically interesting models of large-scale structure. In particular, successful reconstructions constrain the nature of any bias between the galaxy and mass distributions, since processes that modulate the efficiency of galaxy formation on large scales in a way that violates the continuity equation also produce a mismatch between the observed galaxy density and the density inferred from the peculiar velocity field. We obtain successful reconstructions for a gravitational model with peaks biasing, but we also show examples of gravitational and nongravitational models that fail reconstruction tests because of more complicated modulations of galaxy formation.

Babul, Arif↗

Molecular Dynamics Simulations of the Thermal Conductivity of Single-Wall Carbon Nanotubes

Carbon nanotubes (CNT) have very attractive electronic, mechanical. and thermal properties. Recently, measurements of thermal conductivity in single wall CNT mats showed estimated thermal conductivity magnitudes ranging from 17.5 to 58 W/cm-K at room temperature. which are better than bulk graphite. The cylinderical symmetry of CNT leads to large thermal conductivity along the tube axis, additionally, unlike graphite. CNTs can be made into ropes that can be used as heat conducting pipes for nanoscale applications. The thermal conductivity of several single wall carbon nanotubes has been calculated over temperature range from l00 K to 600 K using non-equilibrium molecular dynamics using Tersoff-Brenner potential for C-C interactions. Thermal conductivity of single wall CNTs shows a peaking behavior as a function of temperature. Dependence of the peak position on the chirality and radius of the tube will be discussed and explained in this presentation.

Osman, M.↗

Estimates of ozone response to various combinations of NO(x) and VOC emission reductions in the eastern United States

There is increasing recognition that controls on NO(x) emissions may be necessary, in addition to existing and future Volatile Organic Compounds (VOC) controls, for the abatement of ozone (O3) over portions of the United States. This study compares various combinations of anthropogenic NO(x) and VOC emission reductions through a series of model simulations. A total of 6 simulations were performed with the Regional Oxidant Model (ROM) for a 9-day period in July 1988. Each simulation reduced anthropogenic NO(x) and VOC emissions across-the-board by different amounts. Maximum O3 concentrations for the period were compared between the simulations. Comparison of the simulations suggests that: (1) NO(x) controls may be more effective than VOC controls in reducing peak O3 over most of the eastern United States; (2) VOC controls are most effective in urban areas having large sources of emissions; (3) NO(x) controls may increase O3 near large point sources; and (4) the benefit gained from increasing the amount of VOC controls may lessen as the amount of NO(x) control is increased. This paper has been reviewed in accordance with the U.S. Environmental Protection Agency's peer and administrative review policies and approved for presentation and publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use.

Roselle, Shawn J.↗

Timed to save: the added value of accounting for hourly incidence of electricity savings from residential space-conditioning measures

Abstract Previous research has recognized that the value of measures that reduce electricity usage depends upon the timing of the savings generated, but the lack of hourly savings shapes has limited the demonstration of this concept. We develop empirical hourly savings shapes for residential space-conditioning measures from nearly 18,000 efficiency projects in California and show how they combine with the diurnal and seasonal variation in electricity system costs. We find that these measures (cooling replacements; windows, doors, and skylights; and other envelope measures) tend to save electricity when system costs are highest and that the hourly savings account for 1.4–1.5 times as much value as non-time-sensitive estimates of efficiency would predict. We present these impact multipliers for each measure to quantify the additional value revealed by the time-sensitive approach. We show that this additional value is similar in an evolving electricity grid with storage, rather than natural gas generation, as the marginal resource.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WEC fault modelling and condition monitoring: A graph-theoretic approach

The nature of wave resources usually requires wave energy converter (WEC) components to handle peak loads (i.e., torques, forces, and powers) that are many times greater than their average loads, accelerating equipment degradation. Moreover, due to their isolated nature and harsh operating environment, WEC systems are projected to possess high operations and maintenance (O&M) cost, i.e., around 27% of their leveled cost of energy. As such, developing techniques to mitigate these costs through the application of condition monitoring and fault tolerant control will significantly impact the economic feasibility of grid connected WEC power. Toward this goal, models of faulty components are developed in the open source modeling platform, WEC-Sim, to estimate the performance and measurable states of a WEC operating with likely device and sensor failures. Two types of faulty component models are then applied to a point absorber WEC model with basic controller damping and spring forces. Resulting changes in device behavior are recorded as a benchmark, and a graph-theoretic approach is proposed for fault detection and identification utilizing multivariate time series. Simulation results demonstrate that these faults can greatly affect the WEC performance, and that the proposed method can effectively detect and classify different types of faults.

16 TIDAL AND WAVE POWER↗

Thermal band characterization of LANDSAT-4 thematic mapper

The TM band 6 shutter background and the 34.7 C internal black body signal were measured over 50 day dates. Variability of the shutter background temperature was from 7 C to 11 C. For ten specific images, the digital counts of the calibration data were measured. The average pulse value of the black body peak decreased from 174 to 149 counts while the shutter background counts varied as a function of shutter temperature from 77 to 85. Relative internal gains between the four channels were calculated and compared to prelaunch values. They showed gains over 9 months of up to 5%. Frequency histograms of number of pixels vs. digital counts from a night scene were used to determine gain relative to the mean and to discern a systematic along-scan pattern in a difference between forward and reverse scan counts of up to 0.5. A corrected digital image was obtained. A temperature estimate for and area of Lake Erie of 18.5 C to 19.9 C was obtained. Local temperature records showed 21 C.

Lansing, J. C.↗

Hard X-Ray Lags in GRO J1719--24

We have used the Fourier cross spectra of GRO J1719-24, obtained with BATSE, to estimate the phase lags between the X-ray flux variations in the 20 50 and 50-100 keV energy bands as a function of Fourier frequency in the interval 0.002-0.488 Hz. Our analysis covers the entire about 80 day X-ray outburst of this black hole candidate, following the first X-ray detection on 1993 September 25. The X-ray variations in the 50-100 keV band lag those in the 20-50 keV energy band by an approximately constant phase difference of 0.072 + 0.010 rad in the frequency interval 0.02-0.20 Hz. The peak phase lags in the interval 0.02-0.20 Hz are about twice those of Cyg X-1 and GRO J0422+32. These results are consistent with models for Comptonization regions composed of extended nonuniform clouds around the central source.

VanDerHooft, F.↗

Overview of ACE-Asia Spring 2001 Investigations On Aerosol-Radiation Interactions

ACE-Asia's extensive measurements from land, ocean, air and space quantified aerosol-radiation interactions. Results from each platform type, plus satellite-suborbital combinations, include: 1. Time series of multiwavelength aerosol optical depth (ADD), Angstrom exponent (alpha), single-scattering albedo (SSA), and size distribution from AERONET radiometry at 13 stations. In China and Korea AOD and alpha were strongly anticorrelated (reflecting transient dust events); dust volume-size modes peaked near 8 microns diameter; and SSA(dust) greater than SSA(pollution). 2. Calculations and measurements of photosynthetically active radiation and aerosols in China yield 24-h average downward surface radiative forcing per AOD(500 nm) of -27 W/sq m (400-700 nm). 3. The Hawaii-Japan cruise sampled a gradient with AOD(500 nm) extremes of 0.1 and 1.1. Shipboard measurements showed that adding dust to pollution increased SSA(550 nm, 55% RH), typically from -0.91 to approx. 0.97. Downwelling 8-12 micron radiances showed aerosol effects, especially in the major April dust event, with longwave forcing estimated at -5 to 15 W/sq m. 4. Extinction profiles from airborne sunphotometry and total-direct-diffuse radiometry show wavelength dependence often varying strongly with height, reflecting layering of dust-dominated over pollution-dominated aerosols. Comparing sunphotometric extinction profiles to those from in situ measurements (number and composition vs size, or scattering and absorption) shows layer heights agree, but extinction sometimes differs. 5. Airborne solar spectral flux radiometry yields absorption spectra for layers. Combining with AOD spectra yields best-fit aerosol single scattering albedo spectra. 6. Visible, NIR and total solar fluxes combined with AOD give radiative forcing efficiencies at surface and aloft.

Russell, P. B.↗

Estimates of the Lightning NOx Profile in the Vicinity of the North Alabama Lightning Mapping Array

The NASA Marshall Space Flight Center Lightning Nitrogen Oxides Model (LNOM) is applied to August 2006 North Alabama Lightning Mapping Array (NALMA) data to estimate the (unmixed and otherwise environmentally unmodified) vertical source profile of lightning nitrogen oxides, NOx = NO + NO2. Data from the National Lightning Detection Network (Trademark) (NLDN) is also employed. This is part of a larger effort aimed at building a more realistic lightning NOx emissions inventory for use by the U.S. Environmental Protection Agency (EPA) Community Multiscale Air Quality (CMAQ) modeling system. Overall, special attention is given to several important lightning variables including: the frequency and geographical distribution of lightning in the vicinity of the NALMA network, lightning type (ground or cloud flash), lightning channel length, channel altitude, channel peak current, and the number of strokes per flash. Laboratory spark chamber results from the literature are used to convert 1-meter channel segments (that are located at a particular known altitude; i.e., air density) to NOx concentration. The resulting lightning NOx source profiles are discussed.

Koshak, William J.↗

Influence of Population Variation of Physiological Parameters in Computational Models of Space Physiology

The earliest manifestations of Visual Impairment and Intracranial Pressure (VIIP) syndrome become evident after months of spaceflight and include a variety of ophthalmic changes, including posterior globe flattening and distension of the optic nerve sheath. Prevailing evidence links the occurrence of VIIP to the cephalic fluid shift induced by microgravity and the subsequent pressure changes around the optic nerve and eye. Deducing the etiology of VIIP is challenging due to the wide range of physiological parameters that may be influenced by spaceflight and are required to address a realistic spectrum of physiological responses. Here, we report on the application of an efficient approach to interrogating physiological parameter space through computational modeling. Specifically, we assess the influence of uncertainty in input parameters for two models of VIIP syndrome: a lumped-parameter model (LPM) of the cardiovascular and central nervous systems, and a finite-element model (FEM) of the posterior eye, optic nerve head (ONH) and optic nerve sheath. Methods: To investigate the parameter space in each model, we employed Latin hypercube sampling partial rank correlation coefficient (LHSPRCC) strategies. LHS techniques outperform Monte Carlo approaches by enforcing efficient sampling across the entire range of all parameters. The PRCC method estimates the sensitivity of model outputs to these parameters while adjusting for the linear effects of all other inputs. The LPM analysis addressed uncertainties in 42 physiological parameters, such as initial compartmental volume and nominal compartment percentage of total cardiac output in the supine state, while the FEM evaluated the effects on biomechanical strain from uncertainties in 23 material and pressure parameters for the ocular anatomy. Results and Conclusion: The LPM analysis identified several key factors including high sensitivity to the initial fluid distribution. The FEM study found that intraocular pressure and intracranial pressure had dominant impact on the peak strains in the ONH and retro-laminar optic nerve, respectively; optic nerve and lamina cribrosa stiffness were also important. This investigation illustrates the ability of LHSPRCC to identify the most influential physiological parameters, which must therefore be well-characterized to produce the most accurate numerical results.

biomechanics↗