Real-time Selective Harmonic Minimization Using a Hybrid Analog/Digital Computing Method
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.
This article proposes a new pulsewidth modulation (PWM) scheme that reduces common-mode (CM) voltage and switching losses simultaneously in CSI. The proposed PWM [i.e., reduced voltages PWM (RVM)] reduces CM voltages and switching losses by selecting the optimal zero current vector and PWM sequence based on the CSI output voltage conditions. This article also proves the proposed RVM achieves both objectives (i.e., reduced CM voltage and switching losses) simultaneously for all CSI operating conditions without compromising the other objective. The proposed RVM inherently achieves zero-voltage switching (ZVS) conditions during the zero current vector transitions, further reducing the switching losses. Experimental results demonstrate significant reductions in CM voltage, reaching up to approximately 95%, accompanied by an increase of up to about 5.5% in CSI efficiency across a wide operating range compared to alternative PWM methods, confirming the predicted advantages of the proposed RVM.
Not provided.
Abstract Excess loading of nitrogen and phosphorus to river networks causes environmental harm, but reducing loads from large river basins is difficult and expensive. We developed a new tool, the River Basin Export Reduction Optimization Support Tool (RBEROST) to identify the least‐cost combinations of management practices that will reduce nutrient loading to target levels in downstream and mid‐network waterbodies. We demonstrate the utility of the tool in a case study in the Upper Connecticut River Basin in New England, USA. The total project cost of optimized lowest‐cost plans ranged from $18.0 million to $41.0 million per year over 15 years depending on user specifications. Plans include both point source and non‐point source management practices, and most costs are associated with urban stormwater practices. Adding a 2% margin of safety to loading targets improved the estimated probability of success from 37.5% to 99%. The large spatial scale of RBEROST, and the consideration of both point and non‐point source contributions of nutrients, make it well suited as an initial screening tool in watershed planning.
Summary No consensus has been reached on the relationship between CBFB‐MYH11 copies and prognosis. Of 1525 acute myeloid leukemia (AML) patients, 58 with CBFB‐MYH11‐positive AML (16/58 patients with c‐kit mutation) were retrospectively analyzed with a median follow‐up duration of 29.8 (range: 4.8–74.4) months. Of these, 25/58 (43.1%) patients underwent allogeneic hematopoietic stem cell transplantation (allo‐HSCT), 10 of whom had the c‐kit mutation. Of the 33 patients who did not undergo allo‐HSCT, recurrence in patients with CBFB‐MYH11/ABL level >0.1% at any time after two consolidation cycles was significantly higher than in patients with CBFB‐MYH11/ABL level <0.1% (61.9% vs. 0%, P = 0.001); further, the 3‐year relapse‐free survival (RFS; 31.4% vs. 100%, P = 0.004) and event‐free survival (EFS; 33.1% vs. 100%, P = 0.004) were significantly decreased in patients with CBFB‐MYH11/ABL level >0.1% at any time after two consolidation cycles. The 3‐year RFS and EFS rates were lower in patients who did not receive allo‐HSCT than in those who did (31.4% vs 84.6%, P = 0.000; 31.4% vs. 80.8%, P = 0.001). CBFB‐MYH11‐positive AML patients with CBFB‐MYH11/ABL level >0.1% at any time after two cycles of consolidation had poor prognoses, and allo‐HSCT could improve their survival.
Abstract not provided.
Source oxidation of easily oxidizing elements such as Ca, Sr, Ba, and Ti in an oxidizing ambient leads to their flux instability and is one of the biggest problems in the multielemental oxide molecular beam epitaxy technique. Here, the authors report a new scheme that can completely eliminate the source oxidation problem: a self-gettering differential pump using the source itself as the pumping medium. The pump simply comprises a long collimator mounted in front of the source in extended port geometry. With this arrangement, the oxygen partial pressure near the source was easily maintained well below the source oxidation regime, resulting in a stabilized flux, comparable to that of an ultrahigh-vacuum environment. Moreover, this pump has a self-feedback mechanism that allows a stronger pumping effectiveness for more easily oxidizing elements, which is a desired property for eliminating the source oxidation problem.
Purpose: In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. Methods: A MATLAB ray-tracing simulation platform, ScanSim, was used to model a parallel-source telecentric optical-CT imaging system through a polyurethane solid-tank containing a central cylindrical hollow into which PRESAGE radiochromic dosimeters can be placed. A small amount of fluid fills the 1–5 mm gap between the dosimeter and the walls of the tank. The use of the solid-tank reduces the required amount of fluid by approximately 97%. To characterize the efficacy of solid-tank, optical-CT scanning simulations investigated sensitivity to refractive index (RI) mismatches between dosimeter, solid-tank, and fluid, for a variety of dosimeter (RI = 1.5–1.47) and fluid (RI = 1.55–1.0) combinations. Efficacy was evaluated through the usable radius (r{sub u}) metric, defined as the fraction of the radius of the dosimeter where measured dose is predicted to be within 2% of the ground truth entered into the simulation. Additional simulations examined the effect of increasing gap size (1–5 mm) between the dosimeter and solid-tank well. The effects of changing the lens tolerance (0.5°–5.0°) were also investigated. Results: As the RI mismatch between the dosimeter and solid-tank increased from 0 to 0.02, the usable radius decreased from 97.6% to 50.2%. The optimal fluid RI decreased nonlinearly from 1.5 to 1.34 as the mismatch increased and was up to 9% lower than the tank. Media mismatches between the dosimeter and solid-tank also exacerbate the effects of changing the gap size, with no easily quantifiable relationship with usable radius. Generally, the optimal fluid RI value increases as gap size increases and is closely matched to the dosimeter at large gap sizes (>3 mm). Increasing the telecentric lens tolerance increases the usable radius for all refractive media combinations and improves the maximum usable radius of mismatched media to that of perfectly matched media for tolerances >5.0°. The maximum usable radius can be improved up to a factor of 2 when lens tolerances are small (<1.0°). Conclusions: Dry solid-tank optical-CT imaging in a telecentric system is feasible if the dosimeter RI is a close match with the solid-tank (<0.01 difference), providing accurate dose measurements within ±2% of true dose to over 80% of the dosimeter volume. In order to achieve accurate measurements over 96% of the dosimeter volume (representing out to 2 mm from the dosimeter edge), the dosimeter-tank RI mismatch must be less than 0.005. Optimal results occur when the RI of the dosimeter and tank is the same, in which case the fluid will have the same RI. If mismatches between the tank and dosimeter RI occur, the RI of the matching fluid needs to be fine tuned to achieve the highest usable radius.
Purpose: Failure mode and effects analysis (FMEA) is a widely used tool to evaluate safety or reliability in conventional photon radiation therapy. However, reports about FMEA application in proton therapy are scarce. The purpose of this study is to apply FMEA in safety improvement of proton treatment planning at their center. Methods: The authors performed an FMEA analysis of their proton therapy treatment planning process using uniform scanning proton beams. The authors identified possible failure modes in various planning processes, including image fusion, contouring, beam arrangement, dose calculation, plan export, documents, billing, and so on. For each error, the authors estimated the frequency of occurrence, the likelihood of being undetected, and the severity of the error if it went undetected and calculated the risk priority number (RPN). The FMEA results were used to design their quality management program. In addition, the authors created a database to track the identified dosimetric errors. Periodically, the authors reevaluated the risk of errors by reviewing the internal error database and improved their quality assurance program as needed. Results: In total, the authors identified over 36 possible treatment planning related failure modes and estimated the associated occurrence, detectability, and severity to calculate the overall risk priority number. Based on the FMEA, the authors implemented various safety improvement procedures into their practice, such as education, peer review, and automatic check tools. The ongoing error tracking database provided realistic data on the frequency of occurrence with which to reevaluate the RPNs for various failure modes. Conclusions: The FMEA technique provides a systematic method for identifying and evaluating potential errors in proton treatment planning before they result in an error in patient dose delivery. The application of FMEA framework and the implementation of an ongoing error tracking system at their clinic have proven to be useful in error reduction in proton treatment planning, thus improving the effectiveness and safety of proton therapy.
Purpose: Dual-energy image subtraction represents a useful tool to improve the detectability of small lesions, especially in dense breasts. A feature it shares with all x-ray imaging techniques is the appearance of fluctuations in the texture of the background, which can obscure the visibility of interesting details. The aim of the work is to investigate the main noise sources, in order to create a better performing subtraction mechanism. In particular, the structural noise cancellation was achieved by means of a suitable extension of the dual-energy algorithm. Methods: The effect of the cancellation procedure was tested on an analytical simulation of a target with varying structural composition. Subsequently, the subtraction algorithm was also applied to a set of actual radiographs of a breast phantom exhibiting a nonuniform background pattern. The background power spectra of the outcomes were computed and compared to the ones obtained from a standard subtraction algorithm. Results: The comparison between the standard and the proposed cancellations showed an overall suppression of the magnitudes of the spectra, as well as a flattening of the frequency dependence of the structural component of the noise. Conclusions: The proposed subtraction procedure provides an effective cancellation of the residual background fluctuations. When combined with the polychromatic correction already described in a companion publication, it results in a high performing dual-energy subtraction scheme for commercial mammography units.
Silicon demonstrates great potential as a next-generation lithium ion battery anode because of high capacity and elemental abundance. However, the issue of low initial Coulombic efficiency needs to be addressed to enable large-scale applications. There are mainly two mechanisms for this lithium loss in the first cycle: the formation of the solid electrolyte interphase and lithium trapping in the electrode. The former has been heavily investigated while the latter has been largely neglected. Here, through both theoretical calculation and experimental study, we demonstrate that by introducing Ge substitution in Si with fine compositional control, the energy barrier of lithium diffusion will be greatly reduced because of the lattice expansion. This effect of isovalent isomorphism significantly reduces the Li trapping by ~70% and improves the initial Coulombic efficiency to over 90%. We expect that various systems of battery materials can benefit from this mechanism for fine-tuning their electrochemical behaviors.