Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

A Comparison of Machine Learning Methods of Association Tested on Dense Nodal Arrays

The association of phase picks to form events is one of the fundamental components of seismology. Large and dense sensor networks, such as >1000 geophone arrays (and distributed acoustic sensing), offer unique challenges in association due to the vast numbers of observations and high likelihood of errant picks. In addition, the large number of stations can greatly increase the time it takes to perform the association. For this reason, machine learning (ML) methods might provide a more optimal method of association for such networks. In this work, we examine how well ML methods (e.g., Gaussian mixture model association, PhaseLink, and Graph Earthquake Neural Interpretation Engine) can incorporate dense seismic arrays into regional networks and how well they handle the increasing numbers of stations. Here, we test their capabilities on two dense seismic deployments, one within Rock Valley Nevada (52 nodes and a 9-station sparse local network), and the LArge-n Seismic Survey in Oklahoma dense nodal array (>1800 vertical-component geophones). Processing data from these two different styles of dense seismic deployments allows testing of how the ML algorithms can merge array data with a broader regional network, how they deal with poorly picked phases, and how they handle anthropogenic noise. We compare the ML-associated bulletins to those obtained using the Rapid Earthquake Association and Location algorithm, a more traditional method of association. We find that there are very small differences in results between the methods for small networks (<100 stations) with low pick rates. For large networks (>1000), there are enough errant picks that some of the ML methods start to create false events out of noise. We also find that the ML methods vary in computation time significantly but are all faster than the traditional method tested here.

58 GEOSCIENCES↗

Method Evaluation And Field Sample Measurements For The Rate Of Movement Of The Oxidation Front In Saltstone

The objective of this work was to develop and evaluate a series of methods and validate their capability to measure differences in oxidized versus reduced saltstone. Validated methods were then applied to samples cured under field conditions to simulate Performance Assessment (PA) needs for the Saltstone Disposal Facility (SDF). Four analytical approaches were evaluated using laboratory-cured saltstone samples. These methods were X-ray absorption spectroscopy (XAS), diffuse reflectance spectroscopy (DRS), chemical redox indicators, and thin-section leaching methods. XAS and thin-section leaching methods were validated as viable methods for studying oxidation movement in saltstone. Each method used samples that were spiked with chromium (Cr) as a tracer for oxidation of the saltstone. The two methods were subsequently applied to field-cured samples containing chromium to characterize the oxidation state of chromium as a function of distance from the exposed air/cementitious material surface.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U.S. residential consumer product information: Validation of methods for post-stratification weighting of Amazon Mechanical Turk surveys

We present two post-stratification weighting methods to validate survey data collected using Amazon Mechanical Turk (AMT). Two surveys focused on appliance and consumer electronics devices were administered in the spring and summer of 2012 to each of approximately 3,000 U.S. households. Specifically, the surveys asked questions about residential refrigeration products, televisions (TVs) and set-top boxes (STBs). Filtered data were assigned weights using each of two weighting methods, termed “sequential” and “simultaneous,” by examining up to eight demographic variables (income, education, gender, race, Hispanic origin, number of occupants, ages of occupants, and geographic region) in comparison to reference U.S. demographic data from the 2009 Residential Energy Consumption Survey (RECS). Five key questions from the surveys (number of refrigerators, number of freezers, number of TVs, number of STBs and primary service provider) were evaluated with a set of statistical tests to determine whether either method improved the agreement of AMT with reference data, and if so, which method was better. The statistical tests used were: differences in proportions, distributions of proportions (using Pearson’s chi-squared test), and differences in average numbers of devices as functions of all demographic variables. The results indicated that both methods generally improved the agreement between AMT and reference data, sometimes greatly, but that the simultaneous method was usually superior to the sequential method. Some differences in sample populations were found between the AMT and reference data. Differences in the proportion of STBs reflected large changes in the STB market since the time our reference data was acquired in 2009. Differences in the proportions of some primary service providers suggested real sample bias, with the possible explanation that AMT user are more likely to subscribe to providers who also provide home internet service. Differences in other variables, while statistically significant in some cases, were nonetheless considered to be minor. Depending on the intended purpose of the data collected using AMT, these biases may or may not be important; to correct them, additional questions and/or further post-survey adjustments could be employed. In general, based on the analysis methods and the sample datasets used in this study, AMT surveys appeared to provide useful data on appliance and consumer electronics devices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peridynamic Multiscale Finite Element Methods

The problem of computing quantum-accurate design-scale solutions to mechanics problems is rich with applications and serves as the background to modern multiscale science research. The prob- lem can be broken into component problems comprised of communicating across adjacent scales, which when strung together create a pipeline for information to travel from quantum scales to design scales. Traditionally, this involves connections between a) quantum electronic structure calculations and molecular dynamics and between b) molecular dynamics and local partial differ- ential equation models at the design scale. The second step, b), is particularly challenging since the appropriate scales of molecular dynamic and local partial differential equation models do not overlap. The peridynamic model for continuum mechanics provides an advantage in this endeavor, as the basic equations of peridynamics are valid at a wide range of scales limiting from the classical partial differential equation models valid at the design scale to the scale of molecular dynamics. In this work we focus on the development of multiscale finite element methods for the peridynamic model, in an effort to create a mathematically consistent channel for microscale information to travel from the upper limits of the molecular dynamics scale to the design scale. In particular, we first develop a Nonlocal Multiscale Finite Element Method which solves the peridynamic model at multiple scales to include microscale information at the coarse-scale. We then consider a method that solves a fine-scale peridynamic model to build element-support basis functions for a coarse- scale local partial differential equation model, called the Mixed Locality Multiscale Finite Element Method. Given decades of research and development into finite element codes for the local partial differential equation models of continuum mechanics there is a strong desire to couple local and nonlocal models to leverage the speed and state of the art of local models with the flexibility and accuracy of the nonlocal peridynamic model. In the mixed locality method this coupling occurs across scales, so that the nonlocal model can be used to communicate material heterogeneity at scales inappropriate to local partial differential equation models. Additionally, the computational burden of the weak form of the peridynamic model is reduced dramatically by only requiring that the model be solved on local patches of the simulation domain which may be computed in parallel, taking advantage of the heterogeneous nature of next generation computing platforms. Addition- ally, we present a novel Galerkin framework, the 'Ambulant Galerkin Method', which represents a first step towards a unified mathematical analysis of local and nonlocal multiscale finite element methods, and whose future extension will allow the analysis of multiscale finite element methods that mix models across scales under certain assumptions of the consistency of those models.

42 ENGINEERING↗

Optical-based spectroscopic methods for measuring chemical, optical, and physical properties of thin polymer waveguide films

Non-destructive optical-based spectroscopic methods are needed for analyzing “real world” devices that consist of thin polymer waveguide films. Many applications (e.g., sensors, microelectronics, optics, and biomedical applications, etc.) utilize thin polymer waveguide films, and non-destructive characterization methods based on Fourier transform (FT)-plasmon waveguide spectroscopy (PWR) and scanning angle (SA) Raman spectroscopy are used to extract optical, physical, and chemical properties simultaneously. The FT-PWR method measures reflected light at polymer waveguide interface as both the incident frequency (wavelength) and incident angle are scanned. This method uses p- and s-polarized light to simultaneously extract the polymer waveguide thickness and apparent anisotropic indices of refraction. Polystyrene waveguide films ranging from 360 to 800 nm are used to demonstrate the method and it has an average 0.4% relative error when compared to profilometry and atomic force microscopy measurements. SA Raman spectroscopy is used to measure mixed waveguide polymer films consisting of polystyrene-block-poly(methyl methacrylate) and homopolymer poly(methyl methacrylate) (PS-b-PMMA:PMMA), and poly(2-vinylnapthalene)-block-poly(methyl methacrylate) (P2VN-b-PMMA). PMMA homopolymer is added to the PS-b-PMMA solutions to vary the chemical composition. The chemical composition of each mixed film is quantified (SA Raman peak amplitude ratios) and averaged over all incident angles and is termed the Raman amplitude ratio (rps). This parameter is used to calculate the refractive index of each mixed waveguide polymer film. The refractive index is an input parameter for sum square electric field (SSEF) calculations, which are used to model SA Raman spectra as a function of incident angle to extract the film thickness. The mixed polymer waveguide film thicknesses ranged from 495 to 971 nm, and the SA Raman spectroscopy method has an average 5% difference between the values determined by profilometry. The SA Raman spectroscopy method developed for mixed polymer waveguide films is used to measure the chemical composition and extract interface locations in bilayer and trilayer films consisting of PMMA/PS or PMMA/PS/PMMA, respectively. The rps value is averaged over angle ranges corresponding to waveguide mode 0 and waveguide mode 1 for the bilayer and trilayer films, respectively. Six multilayer films are analyzed and their total thicknesses range from 330 to 1260 nm. Iterative SSEF calculations are used to model the SA Raman spectra as a function of incident angle, and the best fit to the experimental data is used to extract the total thickness and interface location(s). The method has an axial spatial resolution of 7 to 80 nm and provides comparable values to films measured by profilometry with an average 8% and 7% difference for the bilayer and trilayer films, respectively.

36 MATERIALS SCIENCE↗

Evaluation of methods to determine strain ranges for use in SMT design curves

This report describes progress on developing a new method for creep-fatigue design that reduces over conservatism, improves the treatment of elastic follow up effects, and simplifies the design procedure, when compared to the existing ASME Boiler and Pressure Vessels Code, Section III, Division 5 method for creep-fatigue design. Specifically, this report describes the development of one of the three components of the new creep-fatigue design method: a design analysis method to represent the steady cyclic strain range in a component in elevated temperature service. The method developed here uses an elastic perfectly plastic (EPP) analysis with a pseudoyield stress selected to bound the width of the steady state stress-strain hysteresis loop. The report also provides a description of the in-development creep-fatigue design method, including a plan to complete the method by developing design curves and a method to account for stress multiaxiality.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of Errors in Solar Power Plant Variability Simulation Methods

Four PV power plant variability simulation methods - no-smoothing, time average, Marcos, and the wavelet variability model (WVM) - were compared to measured data from a 19MW PV power plant to test the relative accuracy of each method. Errors (simulated vs. measured) were quantified using five application-specific metrics: the largest down ramps, the largest up ramps, the mean absolute error in matching the cumulative distribution of large ramps, the total energy contained in down ramps over the entire period considered, total energy in down ramps on the worst day. These errors we evaluated over timescales ranging from 1-second to 1-hour and over plant sizes of 1 to 14MW and the total plant size of 19MWs to determine trends in model errors as a function of timescale and plant size. Overall, the WVM was found to most often have the smallest errors. The Marcos method also often had small errors, including having the smallest errors of all methods at small PV plant sizes (1 to 7MWs). The no-smoothing method had large errors and should not be used. The time average method was an improvement over the no-smoothing method, but generally has larger errors than the WVM and Marcos methods.

14 SOLAR ENERGY↗

A Test of ASTM Methods E1245-03 and E562-11 in Calculating the Volume Fraction of Carbides in a U-10Mo Foil

Volume fraction measurements of carbides in DU-10Mo castings and foils were performed as part of a round robin study aimed at ensuring characterization efforts by multiple laboratories were yielding consistent results. Three of the four labs employed an automatic image analysis method to determine volume fraction of carbides in the metal and reported results around 2%. The other laboratory used a grid intercept count method and reported a fraction percentage of above 5%, about 3% higher than the other labs. At LANL, the method ASTM E1245-03, Determining the Inclusion or Second-Phase Constituent Content of Metals by Automatic Image Analysis was employed with a result of 2.02 ± .26%. There was a need to resolve the large discrepancy in volume fraction measurements reported from the round robin participant that used the grid intercept method. To do this, the grid intercept method outlined in ASTM E562-11, Determining Volume Fraction by Systematic Manual Point Count was also performed on the exact set of micrographs already analyzed by image analysis software at LANL. Calculations carried out following the manual point count method reported a percentage of 2.2 ± .6% similar to the result yielded by the automated image analysis method. Explanations for discrepancies in the results of the two methods are proposed.

36 MATERIALS SCIENCE↗

Initial Development of an Improved Creep-Fatigue Design Method that Avoids the Separate Evaluation of Creep and Fatigue Damage and Eliminates the Requirement for Stress Classification

This report describes a method for capturing the effect of strain range, temperature, hold time, and elastic follow up on the cyclic life of a material undergoing uniaxial load. Developing design correlations of this type requires methods for extrapolating experimental data as a function of hold time and follow up factor. Various extrapolation methods are developed and discussed here and recommendations are developed for the final approaches to be adopted for design use. The report also describes comparisons between the new creep-fatigue design method, described here, and current creep-fatigue design methods in the ASME Boiler and Pressure Vessel Code and associated nuclear Code Cases. These comparisons demonstrate several advantages of the new method: it is easier to execute and is less over conservative than many current approaches. This report, along with a companion on extending these results to multiaxial load and on combining load cycles, represents the accumulation of several years of work on the development of this new approach to creep-fatigue design, combining an elastic perfectly plastic analysis method with simplified model tests measuring the effect of elastic follow up on creep-fatigue cyclic life. The conclusions to this report describe a path forward to developing the required design data for high temperature advanced reactor structural materials and guiding the adoption of the new method in the ASME Boiler and Pressure Vessel Code and related standards.

36 MATERIALS SCIENCE↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An efficient method to estimate the probability density of seismic Green's functions

We present a computationally efficient method to approximate the probability distribution of seismic Green's functions given the uncertainty of an Earth model. The method is based on the Karhunen-Loève (KL) theorem and an approximation of the Green's function (or seismogram) covariance. Using Monte Carlo (MC) simulations as a control case, we demonstrate that our KL-based method can accurately reproduce a probability distribution of seismograms that results from an uncertain Earth model for a MC-derived seismogram covariance. We then describe a method to estimate the covariance of the seismograms resulting from those Earth models that is not based on MC simulations. We use the estimated Green's function covariance in conjunction with our KL-based method to produce a Green's function probability distribution, and compare that distribution to a Green's function probability distribution produced using a MC finite difference method. We find that the Green's function probability distribution approximated using our KL-based method generally mimics that produced using the MC simulations, especially for direct-arriving body waves. However the accuracy of the KL-based method generally decreases for later times in the simulated Green's function distribution.

58 GEOSCIENCES↗

Harnessing Condorcet Methods to Improve Decision-making Based on Ranked Data

Decision-makers must often choose between multiple alternatives based on their relative merits across a variety of criteria. These multiple-criteria decision-making (MCDM) problems must be approached in an objective, measurable, and transparent fashion to obtain well-supported outcomes. The challenge of using sets of ranked data to identify the optimal choice is not unlike the challenge of using ranked ballots to identify the winner of an election in a preference voting system. As such, the methods of rank aggregation used in elections can be applied to help resolve MCDM problems. Previous research into the design of elections and ballots has yielded many algorithms with well-understood properties. A subset of these, called Condorcet methods, reliably identify the “Condorcet winner,” if it exists, giving the result that would defeat any other in a pairwise comparison. That, in addition to several other desirable qualities, makes Condorcet methods like the Schulze method, Ranked Pairs, and Copeland’s method, effective and scalable means for tackling MCDM problems. These rank aggregation methods have been implemented in JavaScript functions for incorporation into a web-based MCDM decision tool. These algorithms can be applied in a wide variety of contexts (for example, determining the “best” environmental remediation method or selecting a subcontractor) to facilitate effective decision-making. The performance of the JavaScript Condorcet prototype tool was compared across the implemented algorithms and with both a non-Condorcet rank aggregation method as well as an implementation of the Simple Multi-Attribute Rating Technique (SMART) algorithm.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exnihilo Transport Methods Manuals Revision 0

Exnihilo is a transport code system that contains both deterministic and stochastic (Monte Carlo) solvers. The deterministic solvers are contained in the Denovo package while the Monte Carlo solvers are implemented in the Shift package. This document explains the mathematical and numerical methods employed within Exnihilo. It is not a users guide, nor is it a code developer's manual. Naturally, there is cross-over between the code implementation and mathematical description of any given method, and these are included for the purpose of greater understanding where appropriate. The purpose of this document is to formally describe the equations that are solved by the various packages inside of Exnihilo. In general, linkages are not made between a given numerical method and the Exnihilo code base. This is largely due to the fact that the Exnihilo code base changes far more rapidly than the actual methods that it is solving. Thus, this documentation would go rapidly out of date if cross-references were made between the methods and the code that implements them. Instead, developers are encouraged to look at the Doxygen-produced code documentation that explains what each translation unit in the code is doing. Where necessary we will make distinctions between methods that are implemented in Exnihilo and methods that are documented to provide better understanding of the broader field and provide context for the chosen methods in Exnihilo.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chelation ion chromatography as an automated, and cost-effective analytical technique for REE determination: method development and applications

Rare earth elements (REEs), as critical minerals, have important uses in modern energy and technologies, yet are vulnerable to potential supply chain disruptions. To establish domestic REE supply chain, efficient REE detection methods for resource characterization and mineral processing will be needed to accelerate innovations for domestic REE recovery. This study developed a rapid, novel, and cost-effective for REE detection method using ion chromatography (IC) for aqueous samples. Various REE-targeted eluent gradients and post-column agent compositions were tested on the chelation ion chromatography (CIC) with UV-vis detector for optimal separation and quantification of REEs within approximately 20 min. The single-channel pump to deliver the post-column solution to UV-vis detector was replaced with a 4-channel gradient pump, to increase operation and maintenance efficiencies. After method optimization, resulting calibration curves for more than ten REEs achieved high coefficients of determination (R2>0.999) and low relatively standard deviations (below 3.24%), demonstrating sub-ppm level detection limits (0.0897 to 0.1149 mg/L). The reliability of the CIC method was validated through comparison with inductively coupled plasma mass spectrometry (ICP-MS), showing strong agreement in REE recovery from certified standards. The impact of metal ions and salts on REE recovery using CIC was also systematically investigated. CIC consistently exhibited reliable performance in the presence of salt solutions such as NaCl and Na₂SO₄ (up to 10,000 mg/L). Our study also found the presence of high concentrations of Al ions (at 10,000 mg/L) significantly influenced REE determination, and elevated concentrations of Ca ions affected the recovery of specific REEs, including La, Ce, and Pr. The CIC method was further tested on REE-containing eluents from solvent extraction tests out of fly ash leachates. REE detection from these real processing fluids were reported to achieve 90% to 100% recovery rate from our IC method, compared to ICP-MS results. This study underscores the potential of CIC as a reliable and efficient alternative for REE determination in complex matrices. It also highlights the importance of minimizing select interfering metal ions in solutions to ensure accurate results. The REE CIC method presents a promising, low-maintenance, salt-tolerant, and cost-effective alternative to traditional analytical methods for REE analysis.

detection of rare earth elements (REE)↗

Assessment of Bacterial Inoculant Delivery Methods for Cereal Crops

Despite growing evidence that plant growth-promoting bacteria can be used to improve crop vigor, a comparison of the different methods of delivery to determine which is optimal has not been published. An optimal inoculation method ensures that the inoculant colonizes the host plant so that its potential for plant growth-promotion is fully evaluated. The objective of this study was to compare the efficacy of three seed coating methods, seedling priming, and soil drench for delivering three bacterial inoculants to the sorghum rhizosphere and root endosphere. The methods were compared across multiple time points under axenic conditions and colonization efficiency was determined by quantitative polymerase chain reaction (qPCR). Two seed coating methods were also assessed in the field to test the reproducibility of the greenhouse results under non-sterile conditions. In the greenhouse seed coating methods were more successful in delivering the Gram-positive inoculant (Terrabacter sp.) while better colonization from the Gram-negative bacteria (Chitinophaga pinensis and Caulobacter rhizosphaerae) was observed with seedling priming and soil drench. This suggested that Gram-positive bacteria may be more suitable for the seed coating methods possibly because of their thick peptidoglycan cell wall. We also demonstrated that prolonged seed coating for 12 h could effectively enhance the colonization of C. pinensis, an endophytic bacterium, but not the rhizosphere colonizing C. rhizosphaerae. In the field only a small amount of inoculant was detected in the rhizosphere. This comparison demonstrates the importance of using the appropriate inoculation method for testing different types of bacteria for their plant growth-promotion potential.

Terrabacter↗

Enhanced Co-Expression Extrapolation (COXEN) Gene Selection Method for Building Anti-Cancer Drug Response Prediction Models

The co-expression extrapolation (COXEN) method has been successfully used in multiple studies to select genes for predicting the response of tumor cells to a specific drug treatment. Here, we enhance the COXEN method to select genes that are predictive of the efficacies of multiple drugs for building general drug response prediction models that are not specific to a particular drug. The enhanced COXEN method first ranks the genes according to their prediction power for each individual drug and then takes a union of top predictive genes of all the drugs, among which the algorithm further selects genes whose co-expression patterns are well preserved between cancer cases for building prediction models. We apply the proposed method on benchmark in vitro drug screening datasets and compare the performance of prediction models built based on the genes selected by the enhanced COXEN method to that of models built on genes selected by the original COXEN method and randomly picked genes. Models built with the enhanced COXEN method always present a statistically significantly improved prediction performance (adjusted p-value ≤ 0.05). Our results demonstrate the enhanced COXEN method can dramatically increase the power of gene expression data for predicting drug response.

60 APPLIED LIFE SCIENCES↗

A new method for inferring city emissions and lifetimes of nitrogen oxides from high-resolution nitrogen dioxide observations: a model study

We present a new method to infer emissions and lifetimes of nitrogen oxides (NO x ) based on tropospheric nitrogen dioxide (NO 2 ) observations together with reanalysis wind fields for cities located in polluted backgrounds. Since the accuracy of the method is difficult to assess due to lack of “true values” that can be used as a benchmark, we apply the method to synthetic NO 2 observations derived from the NASA-Unified Weather Research and Forecasting (NU-WRF) model at a high horizontal spatial resolution of 4 km × 4 km for cities over the continental United States. We compare the inferred emissions and lifetimes with the values given by the NU-WRF model to evaluate the method. The method is applicable to 26 US cities. The derived results are generally in good agreement with the values given by the model, with the relative differences of 2 % ± 17 % (mean ± standard deviation) and 15 % ± 25 % for lifetimes and emissions, respectively. Our investigation suggests that the use of wind data prior to the satellite overpass time improves the performance of the method. The correlation coefficients between inferred and NU-WRF lifetimes increase from 0.56 to 0.79 and for emissions increase from 0.88 to 0.96 when comparing results based on wind fields sampled simultaneously with satellite observations and averaged over 9 h data prior to satellite observations, respectively. We estimate that uncertainties in NO x lifetime and emissions arising from the method are approximately 15 % and 20 %, respectively, for typical (US) cities. The total uncertainties reach up to 43% (lifetimes) and 45% (emissions) by considering the additional uncertainties associated with satellite NO 2 observations and wind data. We expect this new method to be applicable to NO 2 observations from the TROPOspheric Monitoring Instrument (TROPOMI) and geostationary satellites, such as Geostationary Environment Monitoring Spectrometer (GEMS) or the Tropospheric Emissions: Monitoring Pollution (TEMPO) instrument, to estimate urban NO x emissions and lifetimes globally.

54 ENVIRONMENTAL SCIENCES↗