At least 1,531 records · Page 85

MAST YAG Thomson scattering upgrade alignment system

The recent upgrade to the MAST YAG Thomson scattering while enhancing the diagnostic capabilities increased the complexity of the system. There are eight YAG lasers now operational, doubling the number from the previous setup. This means alignment between each laser individually and reference points is essential to guarantee data quality and diagnostic reliability. To address this issue an alignment system was recently installed. It mimics the beams alignment in MAST by sampling 1% of the laser beam that is sent into a telescope which demagnifies by a factor of 8. The demagnified beam is viewed with a CCD camera. By scanning the camera the profile and position of the beams in the scattering zone and in a range of several meters inside MAST can be determined. Therefore alignment is checked along the beam path without having to sample it inside the vessel. The experimental apparatus and test procedures are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SECARB Pressure Monitoring Data

Bottom-hole, above zone monitoring interval, and injection zone pressure data collected during the SECARB project in Cranfield, Mississippi to assess the relationship between pressure field and multiphase field. Submission includes 10-second interval data from Detailed Area of Study wells: CFU31-F1 (injector), CFU31-F2 (observation), CFU31-F3 (observation) and Ella G Lees no. 7 (observation) well located west of the DAS. Associated Publications: Joy, C. A., 2011, The effects of pressure variation and chemical reactions on the elasticity of the lower Tuscaloosa sandstone of the Cranfield Field Mississippi, The University of Texas at Austin, Master’s thesis, 97 p. Kim, S., and Hosseini, S. A., 2013, Above-zone pressure monitoring and geomechanical analysis of a field scale CO2 injection, Cranfield Mississippi, Greenhouse Gases: Science and Technology, doi:10.1002/ghg.1388. Kim, S., and Hosseini, S. A., 2017, Study on the ratio of pore-pressure/stress changes during fluid injection and its implications for CO2 geologic storage: Journal of Petroleum Science and Engineering, v. 149, p. 138-150, doi:10.1016/j.petrol.2016.10.037. Mathias, S. A., Gluyas, J. G., Gonzalez Martinez de Miguel, G. J., and Hosseini, S. A., 2011, Role of partial miscibility on pressure buildup due to constant rate injection of CO2 into closed and open brine aquifers: Water Resources Research, v. 47, W12525, 11 p., doi:10.1029/2011WR011051. Meckel, T. A., Zeidouni, M., Hovorka, S. D., and Hosseini, S.A., 2013, Assessing sensitivity to well leakage from three years of continuous reservoir pressure monitoring during CO2 injection at Cranfield, MS, USA: International Journal of Greenhouse Gas Control, [insert volume no., page numbers], doi:10.1016/j.ijggc.2013.01.019. Nicot, J.-P., Oldenburg, C. M., Bryant, S. L., and Hovorka, S. D., 2009, Pressure perturbations from geologic carbon sequestration: area-of-review boundaries and borehole leakage driving forces, in Energy Procedia (v. 1, no.1), Proceedings of 9th International Conference on Greenhouse Gas Control Technologies, GHGT9, 16–20 November, Washington DC, p. 47–54. Tao, Q., Bryant, S. L., and Meckel, T. A., 2013, Modeling above-zone measurements of pressure and temperature for monitoring CCS sites: International Journal of Greenhouse Gas Control, v. 18, p. 523–530, doi:10.1016/j.ijggc.2012.08.011.

above zone monitoring interval↗

Certification and User Manual for A 5kW Heat Exchanger Test Loop at Low Temperatures and High-Pressures

Yankee Scientific has designed and built a custom heat exchanger test stand (HXTS), for Oak Ridge National Laboratory, to support a program to develop advanced heat exchangers (HX) for geothermal Organic Rankine Cycle (ORC) power plants under Subcontract Number 40000141544 with ORNL. The test stand was designed to measure the performance of laboratory scale sub-sections of these advanced heat exchangers. Provisions have been made to facilitate testing the advanced heat exchanger as a primary refrigerant vaporizer and as a recuperator and as the system condenser. The test loop was operated with a controller and was instrumented with 11 thermocouples, 5 pressure gauges, 2 pressure transducers, 2 differential pressure transducers, and 3 flow meters.

15 GEOTHERMAL ENERGY↗

Scaling Containment on a Large Centrifuge

Containment science concerns the trapping or leakage of radioactive cavity gases from underground nuclear explosions (UNEs). The most physically relevant data for validation of containment science comes from legacy UNE testing or large field-scale chemical explosions. Field-scale tests can inform on the degree of residual stress imparted to host geology and possible formation of an accompanying gas-containing “stress cage”, for example, as a function of chemical explosion yield. However, field testing can be expensive, difficult to conduct, and challenging to instrument with limitations on data coverage (i.e., the number of boreholes; difficult coring through damage zones). Small-scale laboratory tests are typically simpler to conduct and more thoroughly characterize, but may not include the right scale of containment processes for stress-cage or chimney formation. This report presents the theory and fundamentals of large centrifuge physical modeling, including a history of explosive or similar testing relevant to containment science investigations on centrifuges. Subscale models with embedded chemical explosives in the enhanced gravity of a large centrifuge can represent hundreds of meters of depth and large explosions not otherwise attainable in the laboratory as based on scaling of length, energy, and other processes by the g-factor of the centrifuge (i.e., the number of times larger the centrifugal force is than the gravitational force on the Earth’s surface). The centrifuge uniquely joins the simplicity and exhaustiveness of laboratory-scale characterization with the physics of field-scale processes. This report is part of Sandia National Laboratories’ (SNL’s) effort to prepare for physical modeling with approximately one-meter tall geologic models of stress cage and/or chimney formation on its 29-foot [8.84 m] radius centrifuge with a load capacity of 1.6 million 𝑔-pounds [726 𝑔-ton]. The scaling relationships herein will inform model design decisions and performance requirements for in-flight sensors.

42 ENGINEERING↗

Task 1: Water Depth Management, 1388

The author has identified the following significant results. ERTS-1 MSS data taken on October 10, 1972, of the Little Bahama Bank are being used to demonstrate the use of ERTS-1 data for mapping of shallow water features for the purpose of upgrading world navigation charts. Marked reflectance differences occur for the shallow water areas in bands 4, 5, and 6. Digital processing of two adjacent data tapes within the ERTS-1 frame covering an area of about 40 by 40 miles has been completed. Correlation of depth measurements to 5 meters has been successful. A mathematical model for depth measurements using ratio of voltages in band 4 and 5 has been successfully developed and is being tested for accuracy. Additional studies for areas near Puerto Rico and in northern Lake Michigan will be undertaken. Satellite data will also provide geographical evidence for verifying existence or nonexistence of doubtful shoal waters now appearing on world charts and considered to be hazardous to shipping.

Polcyn, F. C.↗

Calculations of water depth from ERTS-MSS data

ERTS-1 MSS data taken on October 10, 1972 of the Little Bahama Bank are being used to demonstrate the use of ERTS-1 data for mapping of shallow water features for the purpose of upgrading world navigation charts. Marked reflectance differences occur for the shallow water areas in Bands 4, 5, and 6. Digital processing of two adjacent data tapes within the ERTS frame covering an area of about 40 by 40 miles has been completed. Correlation of depth measurements to 5 meters has been successful. A mathematical model for depth measurements using ratio of voltages in Band 4 and 5 has been successfully developed and is being tested for accuracy. Additional studies for areas near Puerto Rico and in Northern Lake Michigan will be undertaken. Satellite data will also provide geographical evidence for verifying existence or nonexistence of doubtful shoal waters now appearing on world charts and considered to be hazardous to shipping.

Polcyn, F. C.↗

Investigation of coaxial jet noise and inlet choking using an F-111A airplane

Measurements of engine noise generated by an F-111A airplane positioned on a thrustmeasuring platform were made at angles of 0 deg to 160 deg from the aircraft heading. Sound power levels, power spectra, and directivity patterns are presented for jet exit velocities between 260 feet per second and 2400 feet per second. The test results indicate that the total acoustic power was proportional to the eighth power of the core jet velocity for core exhaust velocities greater than 300 meters per second (985 feet per second) and that little or no mixing of the core and fan streams occurred. The maximum sideline noise was most accurately predicted by using the average jet velocity for velocities above 300 meters per second (985 feet per second). The acoustic power spectrum was essentially the same for the single jet flow of afterburner operation and the coaxial flow of the nonafterburning condition. By varying the inlet geometry and cowl position, reductions in the sound pressure level of the blade passing frequency on the order of 15 decibels to 25 decibels were observed for inlet Mach numbers of 0.8 to 0.9.

Putnam, T. W.↗

Effect of geometry variations on lee-surface vortex-induced heating for flat-bottom three-dimensional bodies at Mach 6

Studies have shown that vortices can produce relatively severe heating on the leeward surfaces of conceptual hypersonic vehicles and that surface geometry can strongly influence this vortex-induced heating. Results which show the effects of systematic geometry variations on the vortex-induced lee-surface heating on simple flat-bottom three-dimensional bodies at angles of attack of 20 deg and 40 deg are presented. The tests were conducted at a free-stream Mach number of 6 and at a Reynolds number of 1.71 x 10 to the 7th power per meter.

Hefner, J. N.↗

Development of lightning current detector

A lightning current detector to record the maximum current amplitude of a lightning strike to the 150 meter weather tower at KSC was developed. The principle of operation of the detector is discussed, materials chosen to build the detector are described, and calibration tests performed on the detector are given. Field results of the detectors from two separate lightning strikes to the tower are included.

Livermore, S.↗

The Viking Orbiter Visual Imaging Subsystem

Two Viking spacecraft each consisting of an Orbiter and a Lander are on trajectories toward Mars with arrival dates in June and August 1976. A Visual Imaging Subsystem consisting of two slow-scan television cameras forms part of the scientific payload of each Orbiter. These cameras will be used to evaluate the potential landing sites on Mars and to conduct other scientific investigations of the planet. The camera system described in this paper was subjected to an extensive test and calibration program prior to launch. Based on this calibration and subsequent analyses, absolute photometric accuracies of 8.0% may be achieved. Surface resolution exceeding 100 meters will be achieved from the periapsis portion of the Viking orbits. The inherent geometric accuracies of the Orbiter cameras supersede those of previous planetary missions. The analyses of images acquired during the cruise phase of the mission confirms that the cameras have survived the rigors of launch and are performing in a manner consistent with the prelaunch calibrations.

Wellman, J. B.↗

The Shenandoah concentrator

A 7 meter diameter, parabolic dish solar collector was designed and developed for first application at Shenandoah, Georgia. Key features and requirements for the collector are outlined. Performance test results for collector testing at Sandia Laboratories in Albuquerque are summarized. The key features, requirements and performance of the solar collector subassemblies/subsystems are discussed: mount and drives, reflector, receiver, and collector control unit. Problems experienced during collector testing in Albuquerque are identified and solutions described.

Poche, A. J.↗

Development of advanced avionics systems applicable to terminal-configured vehicles

A technique to add the time constraint to the automatic descent feature of the existing L-1011 aircraft Flight Management System (FMS) was developed. Software modifications were incorporated in the FMS computer program and the results checked by lab simulation and on a series of eleven test flights. An arrival time dispersion (2 sigma) of 19 seconds was achieved. The 4 D descent technique can be integrated with the time-based metering method of air traffic control. Substantial reductions in delays at today's busy airports should result.

Heimbold, R. L.↗

Investigation of test methods, material properties and processes for solar cell encapsulants

The goal of the program is to identify, test, evaluate and recommend encapsulation materials and processes for the fabrication of cost-effective and long life solar modules. Of the $18 (1948 $) per square meter allocated for the encapsulation components approximately 50% of the cost ($9/sq m) may be taken by the load bearing component. Due to the proportionally high cost of this element, lower costing materials were investigated. Wood based products were found to be the lowest costing structural materials for module construction, however, they require protection from rainwater and humidity in order to acquire dimensional stability. The cost of a wood product based substrate must, therefore, include raw material costs plus the cost of additional processing to impart hygroscopic inertness. This protection is provided by a two step, or split process in which a flexible laminate containing the cell string is prepared, first in a vacuum process and then adhesively attached with a back cover film to the hardboard in a subsequent step.

Willis, P. B.↗

Structural optimization and recent large ground antenna installations

Within the past several years, the Jet Propulsion Laboratory has designed and built major ground antenna structures in Spain, Australia, and California. One of the antennas at each location is a 70 meter-diameter structure that is a retrofit of the existing 64 meter antenna. The 64 meter existing antennas were first stripped back to a 34 meter interior and then completely new construction with deeper trusses was added to extend the interior to 70 meters. The 70 meter project included the rare opportunity to collect field data to compare with predictions of the finite-element analytical models. The new quadripod design was tested for its lower mode natural frequencies and the main reflector was measured by theodolite to determine deflections of subsets of the backup-structure deformations under load. The emphasis here is to examine measurement results and possibly provide some appreciation of the relationship of predictions made from the design model to actual measurements.

Levy, Roy↗

Beta measurements

The second year's results of the BETA project research are presented. The program is divided into two areas, aerosol modification and climatology in the trade wind region and the climatology of BETA (CO2) on remote mountain top locations. Limited data is available on the aerosol climatology of the marine free troposphere (MFT) in the trade wind region. In order to study the effects of cumulus convection on the MFT values of BETA, a cloud model was developed to simulate the evolution of a typical Pacific trade wind cumulus cloud. The stages involved in this development are outlined. The assembly of the major optical components of the lidar was made. Tests were run of the spectral bandwidth of the Synrad laser when a portion of the beam is mixed with a component which has traveled 450 meters corresponding to a delay of 1.5 microsecs. The bandwidth of the beat signal was measured to be 3 KHz. The data processing system based on a parallel processing filter bank analyzer using true time squaring detectors at each filter was completed.

Schotland, R. M.↗

Distributed Scheduling Architecture for Multi-Center Time-Based Metering

The Traffic Management Advisor (TMA) is an air traffic control automation system currently in use in seven Air Route Traffic Control Centers (ARTCCs) to enable time based metering to busy airports within their airspace. However, this system is limited to operation within a single ARTCC, within about a 200 nautical mile radius of the airport, and on relatively simple streams of traffic. The need for coordinated metering within a greater (300+ nautical mile) radius of an airport, on streams of traffic with significant branching, and across ARTCC boundaries, has been identified. Early tests revealed that TMA could not simply be scaled up to handle such a problem. Instead, a loosely coupled hierarchy of schedules, in which constraints from downstream schedules are passed upstream, is required. Such an architecture reduces the reliance on distant projections of arrival times, making schedules robust to changes in sequence and to additions of aircraft (such as aircraft departing inside the system s scheduling horizon). This architecture is also scaleable, easily reconfigurable, and can be networked together. As such, it can be adapted for use in any size or configuration of airspace and with any number of airports delivering restrictions. An implementation of this distributed scheduling architecture is currently undergoing testing in the TMA-Multi Center system. This paper describes the architecture and its motivation.

Landry, Steven↗

High Reynolds Number Investigation of a Flush-Mounted, S-Duct Inlet With Large Amounts of Boundary Layer Ingestion

An experimental investigation of a flush-mounted, S-duct inlet with large amounts of boundary layer ingestion has been conducted at Reynolds numbers up to full scale. The study was conducted in the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. In addition, a supplemental computational study on one of the inlet configurations was conducted using the Navier-Stokes flow solver, OVERFLOW. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on aerodynamic interface plane diameter) from 5.1 million to 13.9 million (full-scale value), and inlet mass-flow ratios from 0.29 to 1.22, depending on Mach number. Results of the study indicated that increasing Mach number, increasing boundary layer thickness (relative to inlet height) or ingesting a boundary layer with a distorted profile decreased inlet performance. At Mach numbers above 0.4, increasing inlet airflow increased inlet pressure recovery but also increased distortion. Finally, inlet distortion was found to be relatively insensitive to Reynolds number, but pressure recovery increased slightly with increasing Reynolds number.

Berrier, Bobby L.↗

High Reynolds Number Investigation of a Flush Mounted, S-Duct Inlet With Large Amounts of Boundary Layer Ingestion

An experimental investigation of a flush-mounted, S-duct inlet with large amounts of boundary layer ingestion has been conducted at Reynolds numbers up to full scale. The study was conducted in the NASA Langley Research Center 0.3-Meter Transonic Cryogenic Tunnel. In addition, a supplemental computational study on one of the inlet configurations was conducted using the Navier-Stokes flow solver, OVERFLOW. Tests were conducted at Mach numbers from 0.25 to 0.83, Reynolds numbers (based on aerodynamic interface plane diameter) from 5.1 million to 13.9 million (full-scale value), and inlet mass-flow ratios from 0.29 to 1.22, depending on Mach number. Results of the study indicated that increasing Mach number, increasing boundary layer thickness (relative to inlet height) or ingesting a boundary layer with a distorted profile decreased inlet performance. At Mach numbers above 0.4, increasing inlet airflow increased inlet pressure recovery but also increased distortion. Finally, inlet distortion was found to be relatively insensitive to Reynolds number, but pressure recovery increased slightly with increasing Reynolds number.This CD-ROM supplement contains inlet data including: Boundary layer data, Duct static pressure data, performance-AIP (fan face) data, Photos, Tunnel wall P-PTO data and definitions.

Berrier, Bobby L.↗