Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “information loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

OC6 Phase III Definition Document

The objective of Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was to evaluate the accuracy of aerodynamic load predictions by offshore wind modeling tools for a floating offshore wind turbine as it experiences large surge-translational and pitch-rotational motion, as would occur during normal operation. A variety of models were examined in the project, with the goal of performing a three-way validation between engineering-level tools, higher-fidelity tools, and measurement data from two wind tunnel experimental campaigns. This document provides the necessary information to model and simulate the system studied in the OC6 Phase III project. This information is not only useful for project participants, but also future modelers who want to replicate this work for verification and validation purposes.

17 WIND ENERGY↗

Structural Characterization of Deployed Thermoplastic and Thermoset Composite Tidal Turbine Blades

The National Renewable Energy Laboratory worked with Verdant Power to manufacture, and characterize, novel thermoplastic composite blades on their Gen5d 5 m diameter turbines at the Roosevelt Island Tidal Energy (RITE) site in the East River in N.Y. to demonstrate a low-cost manufacturing process for marine energy structures. Verdant had designed, manufactured, and deployed epoxy thermoset composite blades on three Gen5d turbines in October 2020. At a maintenance cycle in May 2021, a Gen5d turbine equipped with the NREL thermoplastic blades was deployed and retrieved in October 2021. Modal, static and fatigue structural characterization was performed on both blade types before and after the deployment. The static and modal test results showed that the thermoplastic blades were slightly stiffer than the epoxy blades both dry and after the deployment. The epoxy blades had about 8% increase in strain at the applied load after the deployment, whereas the thermoplastic blade strains were not changed significantly. Ultimately the thermoplastic blade failed during fatigue testing due to a crack which is thought to have initiated between the internal foam and the laminate at the location of the internal instrumentation. The Verdant Power Gen5d epoxy blades did not have this internal instrumentation and did not have this failure, performing adequately through the operational period. A lack of design information and fatigue data for both the thermoplastic laminates and the adhesive used means that further work is needed to fully understand his failure and the root cause analysis is ongoing. This paper provides details on the thermoplastic blade manufacturing, materials, test methodology and results.

17 WIND ENERGY↗

Nonlinear stress waves in a perfectly flexible string

This paper discusses nonlinear stress-wave propagation in a perfectly flexible string obeying a quasilinear (rate-dependent) constitutive equation. Wave speeds and compatibility relations valid along various families of characteristics were determined. It was shown that the compatibility relations associated with the transverse as well as the longitudinal waves readily yield a physical interpretation when they are expressed in suitable variables and in vector form. Coding based on the present information was completed for the machine solution of a class of mixed initial- and boundary-value problems of practical interest. Computer simulation of the stress-wave interaction in the 40-foot lanyard in the Arcas 'Rocoz' system during deployment was carried out using a stress-strain relation for nylon at the strain rate of 30/second. A method for estimating the maximum tension and strain in a string during the initial loading phase is proposed.

Fan, D.-N.↗

Assembly considerations for large reflectors

The technologies developed at LaRC in the area of erectable instructures are discussed. The information is of direct value to the Large Deployable Reflector (LDR) because an option for the LDR backup structure is to assemble it in space. The efforts in this area, which include development of joints, underwater assembly simulation tests, flight assembly/disassembly tests, and fabrication of 5-meter trusses, led to the use of the LaRC concept as the baseline configuration for the Space Station Structure. The Space Station joint is linear in the load and displacement range of interest to Space Station; the ability to manually assemble and disassemble a 45-foot truss structure was demonstrated by astronauts in space as part of the ACCESS Shuttle Flight Experiment. The structure was built in 26 minutes 46 seconds, and involved a total of 500 manipulations of untethered hardware. Also, the correlation of the space experience with the neutral buoyancy simulation was very good. Sections of the proposed 5-meter bay Space Station truss have been built on the ground. Activities at LaRC have included the development of mobile remote manipulator systems (which can traverse the Space Station 5-meter structure), preliminary LDR sun shield concepts, LDR construction scenarios, and activities in robotic assembly of truss-type structures.

Bush, H.↗

Wake coupling to full potential rotor analysis code

The wake information from a helicopter forward flight code is coupled with two transonic potential rotor codes. The induced velocities for the near-, mid-, and far-wake geometries are extracted from a nonlinear rigid wake of a standard performance and analysis code. These, together with the corresponding inflow angles, computation points, and azimuth angles, are then incorporated into the transonic potential codes. The coupled codes can then provide an improved prediction of rotor blade loading at transonic speeds.

Torres, Francisco J.↗

Development and Testing of Functionally Operative and Visually Appealing Remote Firing Room Displays and Applications

This internship provided an opportunity for an intern to work with NASA's Ground Support Equipment (GSE) for the Spaceport Command and Control System (SCCS) at Kennedy Space Center as a remote display developer, under NASA technical mentor Kurt Leucht. The main focus was on creating remote displays and applications for the hypergolic and high pressure helium subsystem team to help control the filling of the respective tanks. As a remote display and application developer for the GSE hypergolic and high pressure helium subsystem team the intern was responsible for creating and testing graphical remote displays and applications to be used in the Launch Control Center (LCC) on the Firing Room's computers. To become more familiar with the subsystem, the individual attended multiple project meetings and acquired their specific requirements regarding what needed to be included in the software. After receiving the requirements for the displays, the next step was to create displays that had both visual appeal and logical order using the Display Editor, on the Virtual Machine (VM). In doing so, all Compact Unique Identifiers (CUI), which are associated with specific components within the subsystem, were need to be included in each respective display for the system to run properly. Then, once the display was created it was to be tested to ensure that the display runs as intended by using the Test Driver, also found on the VM. This Test Driver is a specific application that checks to make sure all the CUIs in the display are running properly and returning the correct form of information. After creating and locally testing the display it needed to go through further testing and evaluation before deemed suitable for actual use. For the remote applications the intern was responsible for creating a project that focused on channelizing each component included in each display. The core of the application code was created by setting up spreadsheets and having an auto test generator, generate the complete code structure. This application code was then loaded and ran on a testing environment set to ensure the code runs as anticipated. By the end of the semester-long experience at NASA's Kennedy Space Center, the individual should have gained great knowledge and experience in various areas of both display and application development and testing. They were able to demonstrate this new knowledge obtained by creating multiple successful remote displays that will one day be used by the hypergolic and high pressure helium subsystem team in the LCC's firing rooms to service the new Orion spacecraft. The completed display channelization application will be used to receive verification from NASA quality engineers.

Display Devices↗

The bill alignment test: Identifying trade-offs with residential rate design options

The proliferation of smart meter data allows the application of new analytic methods to inform regulatory deliberations. The bill alignment test (BAT) method, which compares the costs allocated to each residential customer with their electric bill, is introduced to help regulators consider how a proposed rate design balances various regulatory criteria. The BAT requires an explicit statement of preferences by policymakers or stakeholders and choices about allocating residual costs unassociated with customer-level causality. The BAT is applied to more than 35,000 smart-meter customer load profiles to assess the trade-offs associated with proposed rate designs. Here this example demonstrates the impact of residual cost allocation preferences and tariff design choices on proposed tariff evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methods for In Situ Electroluminescence Imaging of Photovoltaic Modules Under Varying Environmental Conditions

Electroluminescence (EL) imaging is a powerful tool used to identify defects in photovoltaic solar cells. Typically, this type of characterization is performed in the dark using a current injection that equals short-circuit current measured at standard test conditions (STC). Restricting imaging to such a temperature range limits the information obtained about the module and cells. However, it is not trivial to develop a tool that would allow for EL imaging to be performed under a wider range of temperatures. Here we demonstrate an in situ EL imaging capability developed within an environmental chamber that allows for control of sample temperatures between –40 and 90 °C. Additionally, we demonstrate EL imaging of 4-cell mini-modules (MiMo) under front-side mechanical loading. A Raspberry Pi-connected camera with short-pass filter removed is used for EL imaging. The camera is low-cost with a small form-factor, appropriate for use in a harsh, enclosed environment. The camera is installed within a thermally isolating housing mounted within the environmental chamber. Three example cases are given for MiMos that exhibit various forms of degradation including solder fatigue and cell cracking. It is shown that by measuring at conditions above and below STC, different behaviors may be identified. In some cases, restricting characterization to STC may lead to a failure to detect damage existing in the sample.

14 SOLAR ENERGY↗

Distributed Load Shedding Application Architecture and Bi-Level Predictive Estimator Algorithm

Increasing penetrations of distributed renewables are decreasing the effectiveness of traditional decentralized under-frequency load shedding (UFLS) schemes. As more distribution circuits begin to back-feed the transmission system, operation of traditional UFLS may exacerbate frequency instability. This paper presents the conceptual framework for a data-rich environment to coordinate UFLS across multiple distribution providers based on the laminar coordination framework in order to ensure optimal adaptive setting of UFLS relays. Communication and control are enabled through a distributed implementation of the IEC 61968-1 Common Information Model message bus structure. In addition to the proposed architecture, a novel adaptive UFLS scheme informed by a bi-level state estimator to create optimal relay setpoints is introduced. Initial simulation results are presented for the IEEE 14-bus test system on scenarios leading to mis-operation of traditional UFLS.

Anderson, Alexander A.↗

Unlocking load growth at the grid edge: Practices for managing, recovering, and allocating distribution system investments

Utilities and utility regulators are preparing to make significant investments in the electricity distribution system driven by expected load growth in coming years and decades. Regulators will be tasked with vetting investment proposals and implementing cost recovery and allocation mechanisms. In particular, state regulators are anticipating the need to make proactive distribution system investments, building the capability to serve new load in advance of demand. This report focuses on load growth from homes and businesses that adopt electric vehicles and heat pump heating technologies. Through a review of legislation and regulatory dockets in a subset of states, we provide insights into emerging utility and regulatory practices to recover and allocate costs of electrification-driven distribution system investments necessary to accommodate these technologies. Our review focused on utility electrification programs, line extension policies, and proactive investments. Our report is largely descriptive, offering detailed information about approaches different state commissions and utilities have implemented to inform future decision-making.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TransHab Tapered Diamond Stitch Methods - Crewed Inflatable Softgoods Structures

The NASA TransHab project was a flight development program of a crewed inflatable habitat designed for in-space use. Through the course of the development, several novel technologies were developed and patented by NASA. One of these patents included information regarding a custom seam stitch that was used in the TransHab restraint layer design. As the patent protection has ended, the details of the custom seam stitch are being disclosed. The seam stitch developed during the TransHab program is known as the ‘tapered diamond stitch’ and includes both a ‘single’ and ‘double’ tapered diamond pattern for ‘end termination’ and ‘continuous’ webbing components respectively. It was designed for 1-in wide Kevlar webbings with load ratings of 6,000 lbf and 12,500 lbf. The stitch pattern was designed to gradually transfer load along the length of the seam using a tapered diamond geometry. The diamond stitch has been shown in tensile testing to provide greater than 85% load strength efficiency, compared to the pristine webbing.

transhab↗

From Theory to Practice: Feasibility Study of a Thermal Microgrid at a DoD Installation: Preprint

Advanced district thermal energy systems, also known as thermal microgrids, can electrify and decarbonize urban districts in a highly efficient way, but adoption of such systems, especially in the US, has been slow. Thermal microgrids use a network circulating water at near-ambient (60-80 degree F) (15- 25 degree C) temperatures, and water-source heat pumps at connected buildings to boost or lower the temperature for space conditioning and domestic hot water. Addressing challenges related to retrofits of existing buildings for integration with such systems, as well as quantifying the benefits of different configurations, will be key to unlocking the full potential of thermal microgrids for energy savings, decarbonization, and resiliency. This paper will do that, by reporting on preliminary results from a feasibility study of a thermal microgrid, and illustrating the process of conceptual design to seek the best possible performance, within the many constraints of existing buildings. The feasibility study focuses on a cluster of existing buildings, including a grocery store, big box style retail store, motel, and clinic, at a US Department of Defense installation in Germany. The study will assess the performance of a pilot-scale thermal microgrid serving those buildings, in terms of energy, emissions, and life cycle cost, and assess practical considerations (such as building retrofits and scalability) for future implementation. A significant opportunity exists for waste heat recovery from refrigeration at the grocery store (more than offsetting the entire building s space heating load in terms of waste heat availability), and modeling of the proposed thermal microgrid will assess the benefits of the waste heat integration. The moderate operating temperatures of thermal microgrids facilitate the integration of waste heat from a variety of sources, and the networks allow waste heat to be shared amongst buildings in proximity. Along with results on expected energy and emissions performance, as well as waste heat integration, the paper will assess implications of load diversity on system performance. The paper will also discuss the process of evaluating existing building HVAC systems for compatibility with a thermal microgrid, including the feasibility of lower heating hot water temperatures compatible with currently-available water-to-water heat pumps. The cluster of buildings under consideration in this study has much in common with commercial buildings in the United States. The process of and results from this feasibility study can inform assessment of the potential for thermal microgrids in other locations and help unlock the benefits of such systems for decarbonization and energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Tensile Characterization of Thin-Sheet Brittle Metallic Materials

Refractory metals are favorable materials in applications where high strength and ductility are needed at elevated temperatures. In some cases, operating temperatures may be near the melting point of the material. However, as temperature drops, refractory metals typically undergo a significant mechanical response change - ductile-to-brittle transition. These materials may be subjected to high strain rate loading at an ambient temperature state, such as an impact or crash. Knowledge of the high rate material properties are essential for design as well as simulation of impact events. The high rate stress-strain behavior of brittle metallic materials at ambient temperature is rarely studied because of experimental challenges, particularly when failure is involved. Failure typically occurs within the non-gage section of the material, which invalidates any collected stress-strain information. Here, a method to determine a specimen geometry which will produce failures in the gage section is presented. Pure tungsten in thin-sheet form was used as a trial material to select a specimen geometry for high rate Kolsky tension bar experiments. A finite element simulation was conducted to derive a strain correction for more accurate results. The room temperature stress-strain behavior of pure tungsten at a strain rate of 24 s –1 is presented. The outcome of this experimental technique can be applied to other brittle materials for dynamic tensile characterization.

36 MATERIALS SCIENCE↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Deformation twinning and detwinning in extruded Mg-4Al: In-situ experiment and crystal plasticity simulation

Deformation twinning and detwinning in extruded Mg-4Al were investigated using in-situ SEM-DIC experiments and crystal plasticity finite element (CPFE) simulation. In this study, the in-situ SEM-DIC method was used to provide a unique set of data including twin/detwin characteristics and twin area fraction in addition to strain maps. A statistical analysis of the activation of twin variants and twin area fraction during both twinning and detwinning was conducted. A strong correlation was found between twin growth/shrinkage and the Schmid Factor (SF) for individual twin variants Higher twin SF during loading and unloading led to higher twin growth and shrinkage, respectively. However, after the applied compressive strain was removed, the pattern of the twin area fractions of the residual twin variants versus their nominal SFs did not follow the trend observed at the maximum compressive strain. Using a systematic methodology and an advanced twin/detwin model, the PRISMS-Plasticity CPFE simulation was calibrated using experimentally determined stress versus strain and twin area fraction versus strain information. A comprehensive evaluation of the CPFE model was conducted to determine its ability to capture the statistics of twin variants activation and twin area fraction. CPFE accurately captured the statistical aspects of both twinning and detwinning. Finally, it also predicted the first dominant twin variant for 47.5% of the grains and at least one of the two dominant twin variants for 80% of the grains at maximum compressive strain.

36 MATERIALS SCIENCE↗

Constraining the release of Sn to the ambient melting point following shock loading using time-resolved x-ray diffraction

The formation of liquid following release from a shocked state governs the transition from spall to cavitation and the formation of ejecta in metals. In order to build physics-based models of these processes, it is necessary to critically evaluate the relative importance of kinetics and entropy generation during the release along with the accuracy of multiphase equations of state. Tin (Sn) has served as a testbed for a variety of experiments examining strength and ejecta due to its accessible melt boundary and solid–solid phase transitions. This work presents experiments examining the phase evolution of high purity Sn following the shock and release to ambient stress near the melting point. Sn is found to release to states between its ambient solidus and liquidus from approximately 19 to 33 GPa under uniaxial loading, with the two-phase region being characterized by a reduction in the intensity of the (220), (211) β -Sn doublet. Jetting experiments performed at 27–28 GPa exhibit comparable diffraction patterns with what is observed following the uniaxial release. The solid fractions of β-Sn in the ambient mixed phase region are found to decrease linearly with increasing shock stress as increasing liquid Sn is formed. Here, the results provide much needed information for interpreting measurements of dynamic strength at a high strain rate and experiments examining cavitation and shallow bubble collapse in Sn.

, spall↗

Deep Sigma Point Processes-Assisted Chance-Constrained Power System Transient Stability Preventive Control

Here this paper proposes a deep sigma point processes (DSPP)-assisted chance-constrained power system transient stability preventive control method to deal with uncertain renewable energy and loads-induced stability risk. The traditional transient stability-constrained preventive control is reformulated as a chance-constrained optimization problem. To deal with the computational bottleneck of the time-domain simulation-based probabilistic transient stability assessment, the DSPP is developed. DSPP is a parametric Bayesian approach that allows us to predict system transient stability with high computational efficiency while accurately quantifying the confidence intervals of the predictions that can be used to inform system instability risk. To this end, with a given preset confidence probability, we embed DSPP into the primal dual interior point method to help solve the chance-constrained preventive control problem, where the corresponding Jacobian and Hessian matrices are derived. Comparison results with other existing methods show that the proposed method can significantly speed up preventive control while maintaining high accuracy and convergence

97 MATHEMATICS AND COMPUTING↗