Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging and visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Plant features measurements for robotics

Initial studies of the technical feasibility of using machine vision and color image processing to measure plant health were performed. Wheat plants were grown in nutrient solutions deficient in nitrogen, potassium, and iron. An additional treatment imposed water stress on wheat plants which received a full complement of nutrients. The results for juvenile (less than 2 weeks old) wheat plants show that imaging technology can be used to detect nutrient deficiencies. The relative amount of green color in a leaf declined with increased water stress. The absolute amount of green was higher for nitrogen deficient leaves compared to the control plants. Relative greenness was lower for iron deficient leaves, but the absolute green values were higher. The data showed patterns across the leaf consistent with visual symptons. The development of additional color image processing routines to recognize these patterns would improve the performance of this sensor of plant health.

Miles, Gaines E.↗

Software Aids Visualization Of Mars Pathfinder Mission

Report describes Simulator for Imager for Mars Pathfinder (SIMP) computer program. SIMP generates "virtual reality" display of view through video camera on Mars lander spacecraft of Mars Pathfinder mission, along with display of pertinent textual and graphical data, for use by scientific investigators in planning sequences of activities for mission.

Weidner, Richard J.↗

Model system for plant cell biology: GFP imaging in living onion epidermal cells

The ability to visualize organelle localization and dynamics is very useful in studying cellular physiological events. Until recently, this has been accomplished using a variety of staining methods. However, staining can give inaccurate information due to nonspecific staining, diffusion of the stain or through toxic effects. The ability to target green fluorescent protein (GFP) to various organelles allows for specific labeling of organelles in vivo. The disadvantages of GFP thus far have been the time and money involved in developing stable transformants or maintaining cell cultures for transient expression. In this paper, we present a rapid transient expression system using onion epidermal peels. We have localized GFP to various cellular compartments (including the cell wall) to illustrate the utility of this method and to visualize dynamics of these compartments. The onion epidermis has large, living, transparent cells in a monolayer, making them ideal for visualizing GFP. This method is easy and inexpensive, and it allows for testing of new GFP fusion proteins in a living tissue to determine deleterious effects and the ability to express before stable transformants are attempted.

NASA Discipline Plant Biology↗

Visualizing moiré ferroelectricity via plasmons and nano-photocurrent in graphene/twisted-WSe2 structures

Abstract Ferroelectricity, a spontaneous and reversible electric polarization, is found in certain classes of van der Waals (vdW) materials. The discovery of ferroelectricity in twisted vdW layers provides new opportunities to engineer spatially dependent electric and optical properties associated with the configuration of moiré superlattice domains and the network of domain walls. Here, we employ near-field infrared nano-imaging and nano-photocurrent measurements to study ferroelectricity in minimally twisted WSe 2 . The ferroelectric domains are visualized through the imaging of the plasmonic response in a graphene monolayer adjacent to the moiré WSe 2 bilayers. Specifically, we find that the ferroelectric polarization in moiré domains is imprinted on the plasmonic response of the graphene. Complementary nano-photocurrent measurements demonstrate that the optoelectronic properties of graphene are also modulated by the proximal ferroelectric domains. Our approach represents an alternative strategy for studying moiré ferroelectricity at native length scales and opens promising prospects for (opto)electronic devices.

42 ENGINEERING↗

Event Horizon Image within Black Hole Shadow

We argue that a genuine image of the black hole viewed by a distant observer is not its shadow, but a more compact event horizon image probed by the luminous matter plunging into black hole. The external border of the black hole shadow is washed out by radiation from matter plunging into black hole and approaching the event horizon. This effect will crucially influence the results of future observations by the Event Horizon Telescope. We show that gravitational lensing of the luminous matter plunging into black hole provides the possibility for visualization of the event horizon. The lensed image of the event horizon is formed by the highly red-shifted photons emitted by the plunging matter very near the black hole event horizon and detected by a distant observer. The resulting event horizon image is a gravitationally lensed projection on the celestial sphere of the whole black hole event horizon sphere. Seemingly, black holes are the unique objects in the Universe which may be viewed by distant observers at once from both the front and back sides.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-P-59: Detection of Missing Surgical Needles with Intraoperative Mobile X-Ray

Purpose: To determine the minimal detectable size of a surgical needle using intraoperative mobile x-ray imaging. Also, varying techniques such as low kVp and high tube current were tested to investigate whether this improved the detection of the various needle sizes. Methods: Seven surgical needle sizes, 6.5, 8, 11, 13, 16, 17 and 19 mm, were positioned on three regions (thoracic, abdominal and pelvic) of an adult size anthropomorphic RANDO phantom. The phantom represents an average size adult. The phantom, in front of detector, was imaged with 44” x-ray tube to detector distance. For the thoracic region, each needle size was imaged 4 times using the following technique (81 kVp at 32 mAs and 200 mAs; then 100 kVp at 32 mAs and 200 mAs. This was repeated for the abdominal and pelvic regions of the phantom. The images were reviewed by a board certified diagnostic radiologist. Results: The surgical needles sized 13 mm and above were visible at all three body regions using all four kVp and mAs combinations. For surgical needle sizes 8 and 11 mm, the visibility of needle was ambiguous in thoracic region and barely visible abdominal and pelvic regions. Surgical needles, with size smaller than 8 mm, could not be visualized on x-ray with unassisted eyesight. The detectability of the smaller sized needles was not improved with increasing mAs or decreasing kVp. Conclusion: Surgical needle sizes less that 13 mm were not visualized with intraoperative mobile x-ray imaging using various mAs and kVp combinations. Intraoperative mobile x-ray is not recommended to locate surgical needle sizes less than 13 mm for the following reasons: (1) it prevents unnecessary radiation exposure to patient, (2) it avoids the delay time with wound closure and completion of the operative procedure, and (3) it saves radiologist reading time.

60 APPLIED LIFE SCIENCES↗

Experiments at Scale with In-Situ Visualization Using ParaView/Catalyst in RAGE

In this paper I describe some numerical experiments performed using the ParaView/Catalyst in-situ visualization infrastructure deployed in the Los Alamos RAGE radiation-hydrodynamics code to produce images from a running large scale 3D ICF simulation on the Cielo supercomputer at Los Alamos. The detailed procedures for the creation of the visualizations using ParaView/Catalyst are discussed and several images sequences from the ICF simulation problem produced with the in-situ method are presented. My impressions and conclusions concerning the use of the in-situ visualization method in RAGE are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3.2±1.6mm in patients with no endorectal coil, 2.3±0.8mm in patients with 30cc-PFC-filled endorectal-coil and 5.0±1.8mm in patients with 50cc-PFC-filled endorectal-coil. Conclusion: An MR protocol to visualize positive-contrast Sirius markers to assist in the identification of negative-contrast seeds was demonstrated. S Frank is a co-founder of C4 Imaging LLC, the manufacturer of the MRI markers.

60 APPLIED LIFE SCIENCES↗

Determination of the Maturation Status of Dendritic Cells by Applying Pattern Recognition to High-Resolution Images

The maturation or activation status of dendritic cells (DCs) directly correlates with their behavior and immunofunction. A common means to determine the maturity of dendritic cells is from high-resolution images acquired via scanning electron microscopy (SEM) or atomic force microscopy (AFM). While direct and visual, the determination has been made by directly looking at the images by researchers. Here we report a machine learning approach using pattern recognition in conjunction with cellular biophysical knowledge of dendritic cells to determine the maturation status of dendritic cells automatically. The determination from AFM images reaches 100% accuracy. The results from SEM images reaches 94.9%. The results demonstrate the accuracy of using machine learning for accelerating data analysis, extracting information, and drawing conclusions from high-resolution cellular images, paving the way for future applications requiring high-throughput and automation, such as cellular sorting and selection based on morphology, quantification of cellular structure, and DC-based immunotherapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Imaging of Single, Unstained Viruses with Coherent X Rays

We report the recording and reconstruction of x-ray diffraction patterns from single, unstained viruses, for the first time. By separating the diffraction pattern of the virus particles from that of their surroundings, we performed quantitative and high-contrast imaging of a single virion. The structure of the viral capsid inside a virion was visualized. This work opens the door for quantitative x-ray imaging of a broad range of specimens from protein machineries and viruses to cellular organelles. Moreover, our experiment is directly transferable to the use of x-ray free electron lasers, and represents an experimental milestone towards the x-ray imaging of large protein complexes.

60 APPLIED LIFE SCIENCES↗

Stereo Imaging Tactical Helper

The Stereo Imaging Tactical Helper (SITH) program displays left and right images in stereo using the display technology made available by the JADIS framework. An overlay of the surface described by the disparity map (generated from the left and right images) allows the map to be compared to the actual images. In addition, an interactive cursor, whose visual depth is controlled by the disparity map, is used to ensure the correlated surface matches the real surface. This enhances the ability of operations personnel to provide quality control for correlation results, as well as to greatly assist developers working on correlation improvements. While its primary purpose is as a quality control tool for inspecting correlation results, SITH is also straightforward for use as a basic stereo image viewer

Toole, Nicholas T.↗

Star cluster classification using deep transfer learning with PHANGS- HST

Currently available star cluster catalogues from the Hubble Space Telescope (HST) imaging of nearby galaxies heavily rely on visual inspection and classification of candidate clusters. Here, the time-consuming nature of this process has limited the production of reliable catalogues and thus also post-observation analysis. To address this problem, deep transfer learning has recently been used to create neural network models that accurately classify star cluster morphologies at production scale for nearby spiral galaxies (D ≲ 20 Mpc). Here, we use HST ultraviolet (UV)–optical imaging of over 20 000 sources in 23 galaxies from the Physics at High Angular resolution in Nearby GalaxieS (PHANGS) survey to train and evaluate two new sets of models: (i) distance-dependent models, based on cluster candidates binned by galaxy distance (9–12, 14–18, and 18–24 Mpc), and (ii) distance-independent models, based on the combined sample of candidates from all galaxies. We find that the overall accuracy of both sets of models is comparable to previous automated star cluster classification studies (~60–80 per cent) and shows improvement by a factor of 2 in classifying asymmetric and multipeaked clusters from PHANGS-HST. Somewhat surprisingly, while we observe a weak negative correlation between model accuracy and galactic distance, we find that training separate models for the three distance bins does not significantly improve classification accuracy. We also evaluate model accuracy as a function of cluster properties such as brightness, colour, and spectral energy distribution (SED)-fit age. Based on the success of these experiments, our models will provide classifications for the full set of PHANGS-HST candidate clusters (N ~ 200 000) for public release.

79 ASTRONOMY AND ASTROPHYSICS↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Visions of our Planet's Atmosphere, Land and Oceans: NASA/NOAA Electronic-Theater 2002. Spectacular Visualizations of our Blue Marble

Spectacular Visualizations of our Blue Marble The NASA/NOAA Electronic Theater presents Earth science observations and visualizations in a historical perspective. Fly in from outer space to the 2002 Winter Olympic Stadium Site of the Olympic Opening and Closing Ceremonies in Salt Lake City. Fly in and through Olympic Alpine Venues using 1 m IKONOS "Spy Satellite" data. Go back to the early weather satellite images from the 1960s and see them contrasted with the latest US and international global satellite weather movies including hurricanes & "tornadoes". See the latest visualizations of spectacular images from NASA/NOAA remote sensing missions like Terra, GOES, TRMM, SeaWiFS, Landsat 7 including new 1 - min GOES rapid scan image sequences of Nov 9th 2001 Midwest tornadic thunderstorms and have them explained. See how High-Definition Television (HDTV) is revolutionizing the way we communicate science. (In cooperation with the American Museum of Natural History in NYC). See dust storms in Africa and smoke plumes from fires in Mexico. See visualizations featured on the covers of Newsweek, TIME, National Geographic, Popular Science & on National & International Network TV. New computer software tools allow us to roam & zoom through massive global images e.g. Landsat tours of the US, and Africa, showing desert and mountain geology as well as seasonal changes in vegetation. See animations of the polar ice packs and the motion of gigantic Antarctic Icebergs from SeaWinds data. Spectacular new visualizations of the global atmosphere & oceans are shown. See vertexes and currents in the global oceans that bring up the nutrients to feed tiny algae and draw the fish, whales and fisherman. See the how the ocean blooms in response to these currents and El Nicola Nina climate changes. See the city lights, fishing fleets, gas flares and biomass burning of the Earth at night observed by the "night-vision" DMSP military satellite.

Hasler, A. F.↗

Radial differential interior tomography and its image reconstruction with differentiated backprojection and projection onto convex sets

Purpose: Interior tomography has been recognized as one of the most effective approaches in computed tomography (CT) to reduce radiation dose rendered to patients. In this work, the authors propose and evaluate an imaging method of radial differential interior tomography.Methods: In interior tomography, an x-ray beam is collimated to only irradiate the region of interest (ROI) with suspected lesions while the surrounding area/volume of normal tissues/organs is spared. In the proposed imaging method of radial differential interior tomography, the outcome is a ROI image that has gone through a radial differential filtering. The image reconstruction algorithm for the radial differential interior tomography is kept in the fashion of differentiated backprojection and projection onto convex sets, but the required a priori knowledge in a small round area becomes zero and may be more readily available in practice.Results: Using the projection data simulated by computer and acquired by CT scanner, the authors evaluate and verify the performance of the proposed radial differential interior tomography method and its associated image reconstruction algorithm. The preliminary results show that the proposed imaging method can generate an image that is the radial differentiation of a conventional tomographic image and is robust over noise that inevitably exist in practice.Conclusions: It is believed that the proposed imaging method may find its utility in advanced clinical applications wherein a ROI-based image processing and analysis is required for lesion visualization, characterization, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and demonstration of a low‐field magnetic resonance imaging rhizotron for in‐field imaging of energy sorghum roots

Abstract Root phenotyping provides critical information to plant breeders for developing varieties with improved drought tolerance, greater root biomass, and greater nutrient use efficiency. Phenotyping roots in the natural environment is important for understanding the effect of the soil environment on root genotypic expressions. The goal of this work was to design and test a field‐scale mobile low‐field magnetic resonance imaging (LF‐MRI) Rhizotron that produces actionable root phenotyping data. We demonstrated this novel technology for root visualization and quantification using a LF‐MRI Rhizotron operating at 47 mT with two soil types. The LF‐MRI Rhizotron weights 453 kg, with a height of 90 cm, a diameter of 28 cm and an imaging field of view of 28 cm × 28 cm. The unit was operated in a Belk clay (Entic Hapluderts) and Weswood silt loam (Udifluventic Halustepts) generating 2‐D and 3‐D image data sets. The 2‐D image data had a collection time of 16.5 min per image at an image resolution of 2.2 mm per pixel. The 3‐D data had a collection time of 13 h per image with a 2.2 × 2.2 × 2.2 mm voxel resolution. Low‐field magnetic resonance imaging worked well for visualizing roots in moderate to high clay soils, demonstrating the potential for this technology; however, the broad application of this platform is hampered due to the prohibitively long scanning time to obtain 3‐D images. By increasing the field strength, and therefore the signal‐to‐noise ratio, faster scan times can enable a more useful system for root phenotyping.

Bagnall, G. Cody↗

Tip-Enhanced Raman Chemical and Chemical Reaction Imaging in H 2 O with Sub-3-nm Spatial Resolution

Reproducible chemical and chemical reaction nano-imaging at solid-liquid interfaces remains challenging, particularly when resolutions on the order of a few nm are sought after. In this work, we demonstrate the latter through liquid tip-enhanced Raman (TER) measurements that target gold nanoplates functionalized with 4-mercaptobenzonitrile (MBN). In addition to chemical imaging and local optical field nano-visualization with high spatial resolution, we observe the signatures of 4-mercaptobenzoic acid, which forms as a result of plasmon-induced hydrolysis of MBN. Evidently, the solvent leads to distinct plasmon-induced/enhanced chemical reaction pathways that have not been documented. Here this work shows that such reactions that take place at solid-liquid interfaces can be tracked with a record sub-3 nm spatial resolution via TER spectral nano-imaging in liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗