Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Computation and consequences of high order amplitude- and parameter-dependent tune shifts in storage rings for high precision measurements

Nonlinear effects of the various electric field and magnetic field components of storage rings to confine the particles and bend their trajectory can cause substantial amplitude-dependent tune shifts within the beam. Furthermore, tune shifts are often sensitive to variations of system parameters, e.g. total particle momentum offsets $δp$. Such amplitude- and parameter-dependent tune shifts influence the dynamics and stability of a beam in particle storage rings. Thus, it is critical for high precision measurements to analyze and understand these influences. On this basis, we present in this paper normal form methods for the calculation of high order amplitude and system parameter dependencies of the horizontal and vertical tunes in storage rings using the differential algebra (DA) framework within COSY INFINITY. A storage ring is simulated using COSY INFINITY to generate a DA Poincaré return map describing the transverse phase space behavior after each revolution in the storage ring. The map is expanded around the parameter-dependent closed orbit of the system before transforming the resulting map into normal form coordinates to extract the high order tune dependencies on the phase space amplitude and variation in the system parameters. As a specific example, a storage ring similar to the Storage Ring of the Muon g-2 Experiment at Fermilab (E989) is investigated.

43 PARTICLE ACCELERATORS↗

Dual Protective Mechanism of AlPO 4 Coating on High-Nickel Cathode Material for High Energy Density and Long Cycle Life Lithium-Ion Batteries

Cathode material with high nickel content is a promising candidate for the future generation of Li-ion batteries (LIBs). However, severe structural degradation during cycling limits its practical use, especially for electric vehicles. Herein, AlPO 4 nanoparticles were synthesized and then coated onto the surface of a high-nickel layer-structured cathode via a dry coating method. The AlPO 4 nanoparticles coating significantly improved the cycling stability from 69.2% to over 80% capacity retention after 140 cycles. Furthermore, the structure and chemical composition of the AlPO 4 -coated cathode was investigated by XRD, SEM, XPS, and STEM. Compared with the non-coated cathode, we revealed a dual protective mechanism for enhanced cycling stability, where Al doping and Li 3 PO 4 coating play synergistic roles in protecting cathode material through long-term cycling. This work demonstrates a facile and environmentally friendly approach toward improving the performance of high-nickel LIB cathodes, which can be easily scaled up for industrial applications.

25 ENERGY STORAGE↗

A Modular and Flexible High-Frequency-Link Transformer with a Reduced Device Count and Zero High-Side Devices

In general, large power transformers (LPTs) are not interchangeable with each other and their high costs prohibit extensive spare inventories more so considering that on an average only 1.3 LPTs are manufactured for individual design. The latter pose a further challenge since given that the several existing LPTs are reaching their end of service lives, loss of plurality of such LPTs, that form the backbone of U.S. power grid, will clearly run into the problem of energy security related to the non-availability of sufficient spares (and extended lead time) exacerbated further by the fact that these spares are not interchangeable for installations at different locations. Conventional LPT cost millions of dollars and weighs significantly between approximately 100 and 400 tons. Two raw materials—copper and electrical steel—account for over 50 percent of the total cost of an LPT. In recent years, the price volatility of these two commodities in the global market has affected the manufacturing conditions and procurement strategy for LPTs. Transportation is also an important element of the total LPT cost, because an LPT can weigh significantly and often requires long-distance transport. Transporting an LPT is challenging—its large dimensions and heavy weight pose unique requirements to ensure safe and efficient transportation. Current road, rail, and port conditions are such that transportation is taking more time and becoming more expensive. Conventional low-frequency LPTs typically follow a monolithic approach to design due to historical reasons that need to transition to more modular and flexible (e.g., in voltage, impedance, and power flow) designs with ability to seamlessly/near-seamlessly scale. They should also have the ability to incorporate new technologies without in all cases redoing a LPT design from scratch. Given that the cost of raw materials has continued to increase, next-generation LPTs need to pursue avenues for reducing these costs. An added necessity is to reduce the transportability cost, which is significant in conventional LPTs. Further, given that LPTs are for the long term, they need to be durable, efficient, and fault tolerant with overloading capability. Given this backdrop, the objective and accomplishment of this one-year DOE (SPONSOR) R&D project, led by small business NextWatt LLC (PRIME, Lead PI: Dr. Sudip K. Mazumder) and University of Arkansas at Fayetteville (SUBAWARDEE, PI: Dr. Juan Balda) were to explore the design of a (8 – 20 kHz) high-frequency-link (HFL) based 100-MVA LPT with nominal voltage of 115/69 kV, with $15 - $22 dollars US per kVA when manufactured in “moderate” volume, with 99% energy-conversion efficiency, with 300% reduction in both volume and weight compared to a conventional LPT with the same electrical ratings, with impedance variation greater than 5%, with direct AC/AC power conversion capability, with very-high energy-conversion efficiency (using wide-bandgap SiC based field effect MOSFET devices) over a wide operating temperature, with reduction in both volume and weight with regard to conventional low frequency LPT, and with significant reduction in number of devices compared to state of the art solid state transformer topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Studies Related to the Oregon State University High Temperature Test Facility: Scaling, the Validation Matrix, and Similarities to the Modular High Temperature Gas-Cooled Reactor

The Oregon State University (OSU) High Temperature Test Facility (HTTF) is an integral experimental facility that will be constructed on the OSU campus in Corvallis, Oregon. The HTTF project was initiated, by the U.S. Nuclear Regulatory Commission (NRC), on September 5, 2008 as Task 4 of the 5 year High Temperature Gas Reactor Cooperative Agreement via NRC Contract 04-08-138. Until August, 2010, when a DOE contract was initiated to fund additional capabilities for the HTTF project, all of the funding support for the HTTF was provided by the NRC via their cooperative agreement. The U.S. Department of Energy (DOE) began their involvement with the HTTF project in late 2009 via the Next Generation Nuclear Plant project. Because the NRC interests in HTTF experiments were only centered on the depressurized conduction cooldown (DCC) scenario, NGNP involvement focused on expanding the experimental envelope of the HTTF to include steady-state operations and also the pressurized conduction cooldown (PCC). Since DOE has incorporated the HTTF as an ingredient in the NGNP thermal-fluids validation program, several important outcomes should be noted: 1. The reference prismatic reactor design, that serves as the basis for scaling the HTTF, became the modular high temperature gas-cooled reactor (MHTGR). The MHTGR has also been chosen as the reference design for all of the other NGNP thermal-fluid experiments. 2. The NGNP validation matrix is being planned using the same scaling strategy that has been implemented to design the HTTF, i.e., the hierarchical two-tiered scaling methodology developed by Zuber in 1991. Using this approach a preliminary validation matrix has been designed that integrates the HTTF experiments with the other experiments planned for the NGNP thermal-fluids verification and validation project. 3. Initial analyses showed that the inherent power capability of the OSU infrastructure, which only allowed a total operational facility power capability of 0.6 MW, is inadequate to permit steady-state operation at reasonable conditions. 4. To enable the HTTF to operate at a more representative steady-state conditions, DOE recently allocated funding via a DOE subcontract to HTTF to permit an OSU infrastructure upgrade such that 2.2 MW will become available for HTTF experiments. 5. Analyses have been performed to study the relationship between HTTF and MHTGR via the hierarchical two-tiered scaling methodology which has been used successfully in the past, e.g., APEX facility scaling to the Westinghouse AP600 plant. These analyses have focused on the relationship between key variables that will be measured in the HTTF to the counterpart variables in the MHTGR with a focus on natural circulation, using nitrogen as a working fluid, and core heat transfer. 6. Both RELAP5-3D and computational fluid dynamics (CD-Adapco’s STAR-CCM+) numerical models of the MHTGR and the HTTF have been constructed and analyses are underway to study the relationship between the reference reactor and the HTTF. The HTTF is presently being designed. It has ¼-scaling relationship to the MHTGR in both the height and the diameter. Decisions have been made to design the reactor cavity cooling system (RCCS) simulation as a boundary condition for the HTTF to ensure that (a) the boundary condition is well defined and (b) the boundary condition can be modified easily to achieve the desired heat transfer sink for HTTF experimental operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Strain Rate Spall Strength Measurement for CoCrFeMnNi High-Entropy Alloy

In this study, we experimentally investigate the high stain rate and spall behavior of Cantor high-entropy alloy (HEA), CoCrFeMnNi. First, the Hugoniot equations of state (EOS) for the samples are determined using laser-driven CoCrFeMnNi flyers launched into known Lithium Fluoride (LiF) windows. Photon Doppler Velocimetry (PDV) recordings of the velocity profiles find the EOS coefficients using an impedance mismatch technique. Following this set of measurements, laser-driven aluminum flyer plates are accelerated to velocities of 0.5–1.0 km/s using a high-energy pulse laser. Upon impact with CoCrFeMnNi samples, the shock response is found through PDV measurements of the free surface velocities. From this second set of measurements, the spall strength of the alloy is found for pressures up to 5 GPa and strain rates in excess of 106 s−1. Further analysis of the failure mechanisms behind the spallation is conducted using fractography revealing the occurrence of ductile fracture at voids presumed to be caused by chromium oxide deposits created during the manufacturing process.

36 MATERIALS SCIENCE↗

High-performance liquid chromatography of oligoguanylates at high pH

Because of the stable self-structures formed by oligomers of guanosine, standard high-performance liquid chromatography techniques for oligonucleotide fractionation are not applicable. Previously, oligoguanylate separations have been carried out at pH 12 using RPC-5 as the packing material. While RPC-5 provides excellent separations, there are several limitations, including the lack of a commercially available source. This report describes a new anion-exchange high-performance liquid chromatography method using HEMA-IEC BIO Q, which successfully separates different forms of the guanosine monomer as well as longer oligoguanylates. The reproducibility and stability at high pH suggests a versatile role for this material.

Non-NASA Center↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests

high speed imaging↗

Improvements in High Speed, High Resolution Dynamic Digital Image Correlation for Experimental Evaluation of Composite Drive System Components

Composite materials have the potential to reduce the weight of rotating drive system components. However, these components are more complex to design and evaluate than static structural components in part because of limited ability to acquire deformation and failure initiation data during dynamic tests. Digital image correlation (DIC) methods have been developed to provide precise measurements of deformation and failure initiation for material test coupons and for structures under quasi-static loading. Attempts to use the same methods for rotating components (presented at the AHS International 68th Annual Forum in 2012) are limited by high speed camera resolution, image blur, and heating of the structure by high intensity lighting. Several improvements have been made to the system resulting in higher spatial resolution, decreased image noise, and elimination of heating effects. These improvements include the use of a high intensity synchronous microsecond pulsed LED lighting system, different lenses, and changes in camera configuration. With these improvements, deformation measurements can be made during rotating component tests with resolution comparable to that which can be achieved in static tests.

composite materials↗

Development of a High Frequency Class-A Amplifier for High Temperature Wireless Microsystems based on a Silicon Carbide Static Induction Transistor

Next generation gas turbine engine health monitoring for high performance jet engine-powered aircraft will incorporate integrated microelectronic sensors specifically designed to enhance aircraft functionality, engine efficiency, and safety. Temperature, air flow and pressure associated with the gas path as well as emissions from the engine correlate to the state of the combustor and other engine health conditions. Monitoring these parameters accurately requires positioning electronic sensors in the hot zone of the gas turbine engine, which exposes them to temperatures in excess of 400ºC. At these temperatures, signal amplification is needed at the transducer level to distinguish the desired measured signal from the significant electronic noise generated by the harsh environment. In this presentation, we report on the simulation, development, fabrication, and testing on a high temperature Class-A amplifier which utilizes a 4H-SiC Static Induction Transistor (SIT) as the active device and input/output matching and DC bias networks comprised of thin-film spiral inductors, metal-insulator-metal capacitors, and thick film chip resistors. A small signal model that emulates the operation of the 4H-SiC SIT from 25 to 400ºC, with an emphasis on operation at 400οC, was utilized. Measurements were performed from 25 to 400ºC to generate current-voltage curves, capacitive transistor characteristics and high frequency scattering parameters (S-parameters). The measured data was used to extrapolate the transconductance, gm, as a function of temperature for model development. Circuit simulation tools were used to generate S-parameters, which were compared to the measured values. At 400οC, a maximum difference between measured and simulated S-parameters for frequencies from 20 to 100 MHz were 3.84%, 0.68%, 10.61%, and 3.26% for S21, S12, S11, and S22, respectively. The average transit frequency, ft, was calculated from measured values to be 197.8 MHz, while the simulated value from the model was found to be 200 MHz. The Amplifier’s S-parameters were recorded at 20-100 MHz over a temperature range of 25-400ºC and show a gain of approximately 15.8 and 5.80 dBm at 25 and 400ºC, respectively. The input and output reflection coefficients at 50 MHz and 400ºC were -18.5 and -15.2 dB, respectively. The noise figure and phase noise were measured over the temperature range of 25-400ºC and recorded. The noise figure increased 21% at 50 MHz over the temperature range, while the 1 kHz offset of the phase noise remained below -110 dB. The stability factor, K, calculated with measured and simulated data demonstrates unconditional stability over the frequency range at 400ºC. Lastly, the 1-dB compression point was measured at 50 MHz and 400ºC with an approximated output of 9.5 dBm.

SiC↗

Assessing High-Intensity Radiated Fields (HIRF) from High-Power Antennas for Air Vehicle Safety

Advanced Air Mobility (AAM), including Urban Air Mobility (UAM), vehicles may be required to meet stringent High-Intensity Radiated Fields (HIRF) certification requirements. HIRF can cause interference and even damage to vehicle systems. A recently proposed map-based avoidance approach can help reduce HIRF protection costs compared to the standard approach. However, it necessitates knowing the locations, frequencies, and transmit powers of high-power antennas within the operating area. This study aims to provide the necessary transmitter data by utilizing regulatory license databases. Using New York City as a representative urban area, fixed transmitter data are presented for AM, FM, TV, satellite uplink, land-mobile radio, microwave link, weather radars, and others. The maximum effective isotropic radiated powers of the antenna are reported. The associated electric field envelopes at 100 feet (30.48 m) distance are compared against the current rotorcraft HIRF standard. The results show that the current standards for protecting vehicles are inadequate. Maps of regions with high HIRF are illustrated. Data for several other cities are also being considered.

HIRF↗

Assessing High-Intensity Radiated Fields (HIRF) from High-Power Antennas for Air Vehicle Safety

Advanced Air Mobility (AAM), including Urban Air Mobility (UAM), vehicles may be required to meet stringent High-Intensity Radiated Fields (HIRF) certification requirements. HIRF can cause interference and even damage to vehicle systems. A recently proposed map-based avoidance approach can help reduce HIRF protection costs compared to the standard approach. However, it necessitates knowing the locations, frequencies, and transmit powers of high-power antennas within the operating area. This study aims to provide the necessary transmitter data by utilizing regulatory license databases. Using New York City as a representative urban area, fixed transmitter data are presented for AM, FM, TV, satellite uplink, land-mobile radio, microwave link, weather radars, and others. The maximum effective isotropic radiated powers of the antenna are reported. The associated electric field envelopes at 100 feet (30.48 m) distance are compared against the current rotorcraft HIRF standard. The results show that the current standards for protecting vehicles are inadequate. Maps of regions with high HIRF are illustrated. Data for several other cities are also being considered.

HIRF↗

High-temperature treatment of In-doped CZT crystals grown by the high-pressure Bridgman method

We evaluated the effect of high-temperature treatment of Cd0.9Zn0.1Te:In single crystals using Hall-effect measurements, medium- and high-temperature annealing under various deviations from stoichiometry, and infra-red (IR) transmission microscopy Annealing at ~730 K sharply increased the electrical conductivity (by ~1-2 orders-of-magnitude). Plots of the temperature- and cadmium-pressure dependences of the electrical conductivity, carrier concentration, and mobility were obtained. Treating previously annealed Cd-samples under a Te overpressure at 1070 K allowed us to restore their resistance to its initial high values. The main difference in comparing this material with CdTe was its lowered electron density. We explained our results within the framework of Kröger’s theory of quasi-chemical reactions between point defects in solids.

60 APPLIED LIFE SCIENCES↗

High and Ultra-High Temperature Reaction Kinetics by Single Nanoparticle Mass Spectrometry

Methodology is presented for non-destructive, optically-detected single nanoparticle (NP) mass spectrometry, with the goal of extracting surface reaction kinetics for single NPs at high temperatures. Methods for determining the NP charge, mass, and temperature as a function of time are discussed, and the data are used to extract both the absolute kinetics for mass change, as well as the efficiencies of the surface processes that cause them. Factors that contribute to the uncertainties in absolute and relative mass determination, and in the resulting kinetic parameters, are discussed. The method allows the NP-to-NP variations in initial reactivity to be measured directly, along with the time evolution of reactivity resulting from NP structural/compositional changes that occur under reaction conditions. The strengths and limitations of single nanoparticle mass spectrometry as a high temperature surface kinetics tool are discussed in the context of sublimation and O2 oxidation kinetics experiments for single hafnium (Hf) NPs at temperatures ranging above 2400 K. The Hf oxidation kinetics are compared to analogous oxidation experiments for silicon, graphite, and carbon black NPs. In all four cases, the oxidation chemistry was dominated by processes that result in net mass loss, and the distinct mechanisms responsible are discussed. All four NPs also eventually passivated, i.e., the efficiencies for oxidative etching decreased by at least two orders of magnitude, relative to the initial efficiencies. Furthermore, the passivation mechanisms, which are quite different for carbon, compared to silicon or hafnium, are discussed. Carbon NP passivation is attributed to structural isomerization leading to fully coordinated, fullerene-like NP surfaces, while for silicon and hafnium, passivation results from delayed formation of an oxide layer, triggered by accumulation of oxygen in the NP sub-surface region.

36 MATERIALS SCIENCE↗

Diamond Turned High Precision PIAA Optics and Four Mirror PIAA System for High Contrast Imaging of Exo-planets

Off-axis, high-sag PIAA optics for high contrast imaging present challenges in manufacturing and testing. With smaller form factors and consequently smaller surface deformations (< 80 microns), diamond turned fabrication of these mirrors becomes feasible. Though such a design reduces the system throughput, it still provides 2(lambda)D inner working angle. We report on the design, fabrication, measurements, and initial assessment of the novel PIAA optics in a coronagraph testbed. We also describe, for the first time, a four mirror PIAA coronagraph that relaxes apodizer requirements and significantly improves throughput while preserving the low-cost benefits.

coronagraphy↗

Mass Spectrometry-based Assay for High Throughput and High Sensitivity Biomarker Verification

Searching for disease specific biomarkers has become a major undertaking in the biomedical research field as the effective diagnosis, prognosis and treatment of many complex human diseases are largely determined by the availability and the quality of the biomarkers. A successful biomarker as an indicator to a specific biological or pathological process is usually selected from a large group of candidates by a strict verification and validation process. To be clinically useful, the validated biomarkers must be detectable and quantifiable by the selected testing techniques in their related tissues or body fluids. Due to its easy accessibility, protein biomarkers would ideally be identified in blood plasma or serum. However, most disease related protein biomarkers in blood exist at very low concentrations (<1ng/mL) and are “masked” by many none significant species at orders of magnitude higher concentrations. The extreme requirements of measurement sensitivity, dynamic range and specificity make the method development extremely challenging. The current clinical protein biomarker measurement primarily relies on antibody based immunoassays, such as ELISA. Although the technique is sensitive and highly specific, the development of high quality protein antibody is both expensive and time consuming. The limited capability of assay multiplexing also makes the measurement an extremely low throughput one rendering it impractical when hundreds to thousands potential biomarkers need to be quantitatively measured across multiple samples. Mass spectrometry (MS)-based assays have recently shown to be a viable alternative for high throughput and quantitative candidate protein biomarker verification. Among them, the triple quadrupole MS based assay is the most promising one. When it is coupled with liquid chromatography (LC) separation and electrospray ionization (ESI) source, a triple quadrupole mass spectrometer operating in a special selected reaction monitoring (SRM) mode, also known as multiple reaction monitoring (MRM), is capable of quantitatively measuring hundreds of candidate protein biomarkers from a relevant clinical sample in a single analysis. The specificity, reproducibility and sensitivity could be as good as ELISA. Furthermore, SRM MS can also quantify protein isoforms and post-translational modifications, for which traditional antibody-based immunoassays often don’t exist.

Environmental Molecular Sciences Laboratory↗

High Performance Anion Exchange Membrane Fuel Cells Enabled by Fluoropoly(olefin) Membranes

Abstract Although the peak power density of anion exchange membrane fuel cells (AEMFCs) has been raised from ≈0.1 to ≈1.4 W cm −2 over the last decade, a majority of AEMFCs reported in the literature have not been demonstrated to achieve consistently high performance and steady‐state operation. Poly(olefin)‐based AEMs with fluorine substitution on the aromatic comonomer show considerably higher dimensional stability compared to samples that do not contain fluorine. More importantly, fluorinated poly(olefin)‐based AEMs exhibit high hydroxide conductivity without excessive hydration due to a new proposed mechanism where the fluorinated dipolar monomer facilitates increased hydroxide dissociation and transport. Using this new generation of AEMs, a stable, high‐performance AEMFC is operated for 120 h. When the fuel cell configuration is subjected to a constant current density of 600 mA cm −2 under H 2 /O 2 flow, the cell voltage declines only 11% (from 0.75 to 0.67 V) for the first 20 h during break‐in and the cell voltage loss is low (0.2 mV h −1 ) over the subsequent 100 h of cell testing. The ease of synthesis, potential for low‐cost commercialization, and remarkable ex situ properties and in situ performance of fluoropoly(olefin)‐based AEM renders this material a benchmark membrane for practical AEMFC applications.

Zhu, Liang↗