Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intense 1.54 {mu}m fluorescence of Er{sup 3+}/Yb{sup 3+} codoped phosphate glass and the three-photon phenomenon of near infrared upconversion luminescence

Transparent P{sub 2}O{sub 5}-CaO-Na{sub 2}O glasses codoped with Er{sup 3+} and Yb{sup 3+} ions were fabricated by high-temperature melting technique. Strong near infrared and visible upconversion luminescence were observed under 975 nm laser diode excitation, and the luminescence processes were explained in details. For 1.54 {mu}m band, the calculated peak emission cross sections is 1.04x10{sup -20} cm{sup 2}, and it is better than that in germinate, tellurite, silicate, and other phosphate glasses. The near infrared upconversion emission around 828 nm contains two-photon and three-photon processes, and it is attributed to the transition {sup 4}S{sub 3/2}{yields}{sup 4}I{sub 13/2}, which enhances the population of the upper level for 1.54 {mu}m laser emission and reduces the energy loss due to upconversion. Efficient near infrared fluorescence indicates Er{sup 3+}/Yb{sup 3+} codoped phosphate glass is a promising laser and amplifier material.

36 MATERIALS SCIENCE↗

Quantitative Elemental Microanalysis Of Individual Particles With Use Of X-Ray Fluorescence Method And Monte Carlo Simulation

Recently a considerable interest has been triggered in the investigation of the composition of individual particles by X-ray fluorescence microanalysis. The sources of these micro-samples are mostly diversified. These samples come from space dust, air and ash, soil as well as environment and take the shape of a sphere or an oval. In analysis this kind of samples the geometrical effects caused by different sizes and shapes influence on accuracy of results. This fact arises from the matrix effect. For these samples it is not possible to find analytically a solution of equation taking into account an absorption of X-rays. Hence, a way out is to approximate the real sample shape with the other one or to use Monte Carlo (MC) simulation method. In current work authors utilized the iterative MC simulation to assess an elemental percentage of individual particles. The set of glass micro-spheres, made of NIST K3089 material of known chemical composition, with diameters in the range between 25 and 45 {mu}m was investigated. The microspheres were scanned with X-ray tube primary radiation. Results of MC simulation were compared with these of some analytical approaches based on particle shape approximation. An investigation showed that the low-Z elements (Si, Ca, Ti) were the most sensitive on changes of particle shape and sizes. For high-Z elements (Fe--Pb) concentrations were nearly equal regardless of method used. However, for the all elements considered, results of MC simulation were more accurate then these of analytical relationships taken into comparison.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fluorescence-type Monochromatic X-ray Beam-position Monitor with High-spatial Resolution for the NSLS-II Beamlines

We developed a fluorescence-type monochromatic X-ray beam-position monitor (X-BPM) with high-spatial resolution for end-station experiments at the initial project beamlines of the NSLS-II. We designed a ring array of multi-segmented Si PIN-junction photodiodes to use as a position sensor. Further, we integrated a low-noise charge-preamplification HERMES4 ASIC chip into an electronic readout system for photon-counting application. A series of precision measurements to characterize electronically the Si-photodiode sensor and the ASIC chip demonstrated that the inherent noise from the detector system is sufficiently low to meet our stringent requirements. Using a Gaussian beam, we parametrically modeled the optimum working distance to ensure the detector's best performance. Based upon the results from the parametric modeling, prototypes of the next versions of the X-BPM are being developed. In this paper, we describe the methodology for developing the new compact monochromatic X-ray BPM, including its instrumentation, detector modeling, and future plan.

43 PARTICLE ACCELERATORS↗

Laser induced fluorescence measurements of the cylindrical Hall thruster plume

An investigation of a fully cylindrical Hall thruster was performed using laser induced fluorescence (LIF) to measure ion velocity profiles in the plume. The measurements confirm a previously reported 9% increase in the exhaust energy when the cathode keeper draws an excess current (overrun mode). Furthermore, the velocity directions in the plume remain relatively unchanged for the cusped and direct magnetic field configuration in both overrun and nonoverrun modes. Previously reported plume narrowing in the overrun mode was confirmed and found to be due to the shift of the acceleration and ionization regions toward the anode. The electric field inferred from the LIF measurements allowed calculation of the electron ExB drift. Close to the centerline of the thruster, electrons drift azimuthally with velocity decreasing away from the centerline, thus creating shear. This shear can be a source of plasma instabilities and influence electron transport. Further away from the centerline, electrons drift in the opposite direction with their velocity increasing with increasing radius. In that region, electrons rotate without shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computation of two-dimensional electric field from the ion laser induced fluorescence measurements

This paper presents a method of computing two-dimensional electric field from ion laser induced fluorescence (LIF) measurements in a plasma flow. The expression for the field is derived by taking velocity moments of the Boltzmann equation for ions. It was found that the pressure tensor, related to the width of the ion velocity distribution, plays a critical role in the computation of the electric field. Even with the assumption of cold ion flow, the pressure tensor contribution may be significant when velocity spread is caused by other forces. Such a situation occurs in the flow of a Hall thruster, where velocity spread is caused by the ions born at different potentials. LIF measurements of the cylindrical hall thruster plume were used to demonstrate practical application of the derived method. Whenever the pressure tensor components are small as compared to the mean ion drift velocity, the electric field calculations reduce to a simple expression given in terms of mean ion drift velocity and its divergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

4D Density Determination of NH Radicals in an MSE Microplasma Combining Planar Laser Induced Fluorescence and Cavity Ring-Down Spectroscopy

An application of microplasmas is surface modification under mild conditions and of small, well defined areas. For this, an understanding of the plasma composition is of importance. First results of our work on the production and detection of NH radicals in a capacitively coupled radio frequency (RF) microplasma are presented. A microstructured comb electrode was used to generate a glow discharge in a hydrogen/nitrogen gas mixture by applying 13.56 MHz RF voltage. The techniques of planar laser induced fluorescence (PLIF) and cavity ring-down spectroscopy (CRDS) are used for space and time resolved, quantitative detection of the NH radical in the plasma. The rotational temperature was determined to be 820 K and, the density 5.1x10{sup 12} cm{sup 3}. Also, time dependent behaviour of the NH production was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In Situ Synchrotron Based X-ray Fluorescence and Scattering Measurements During Atomic Layer Deposition: Initial Growth of HfO2 on Si and Ge Substrates

The initial growth of HfO{sub 2} was studied by means of synchrotron based in situ x-ray fluorescence (XRF) and grazing incidence small angle x-ray scattering (GISAXS). HfO{sub 2} was deposited by atomic layer deposition (ALD) using tetrakis(ethylmethylamino)hafnium and H{sub 2}O on both oxidized and H-terminated Si and Ge surfaces. XRF quantifies the amount of deposited material during each ALD cycle and shows an inhibition period on H-terminated substrates. No inhibition period is observed on oxidized substrates. The evolution of film roughness was monitored using GISAXS. A correlation is found between the inhibition period and the onset of surface roughness.

36 MATERIALS SCIENCE↗

Functionalization of cubic boron nitride films with rhodamine B and their fluorescent properties

Fluorophore-functionalized cubic boron nitride (cBN) films grown by chemical vapor deposition were achieved by immobilizing rhodamine B isothiocyanate onto their surfaces. To perform the immobilization, the cBN substrates were modified with amino groups by photochemical reaction between hydrogen-terminated cBN surfaces and allylamine. The surface analysis of hydrogen-terminated cBN films surfaces and after functionalization with x-ray photoelectron spectroscopy verified that rhodamine B was indeed attached to the cBN surfaces with covalent bonding. The rhodamine B-functionalized cBN surfaces showed significant variation in fluorescent spectra and confocal imaging upon the treatment in acidic or basic solutions.

36 MATERIALS SCIENCE↗

Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

Detection of radionuclides emitting short-range radiation, such as {alpha} and low-energy {beta} particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed {sup 241}Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production mechanism of atomic nitrogen in atmospheric pressure pulsed corona discharge measured using two-photon absorption laser-induced fluorescence

To study the production mechanism of atomic nitrogen, the temporal profile and spatial distribution of atomic nitrogen are measured in atmospheric pressure pulsed positive corona discharge using two-photon absorption laser-induced fluorescence. The absolute atomic nitrogen density in the streamer filaments is estimated from decay rate of atomic nitrogen in N{sub 2} discharge. The results indicate that the absolute atomic nitrogen density is approximately constant against discharge energy. When the discharge voltage is 21.5 kV, production yield of atomic nitrogen produced by an N{sub 2} discharge pulse is estimated to be 2.9 - 9.8 Multiplication-Sign 10{sup 13} atoms and the energy efficiency of atomic nitrogen production is estimated to be about 1.8 - 6.1 Multiplication-Sign 10{sup 16} atoms/J. The energy efficiency of atomic nitrogen production in N{sub 2} discharge is constant against the discharge energy, while that in N{sub 2}/O{sub 2} discharge increases with discharge energy. In the N{sub 2}/O{sub 2} discharge, two-step process of N{sub 2} dissociation plays significant role for atomic nitrogen production.

74 ATOMIC AND MOLECULAR PHYSICS↗

Feasibility of characterizing laser-ablated carbon plasmas via planar laser induced fluorescence

Planar laser induced fluorescence (PLIF) imaging can potentially assess ion distributions and coupling in the context of super-Alfvenic ablation plasma expansions into magnetized background plasmas. In this feasibility study, we consider the application of PLIF to rapidly expanding carbon plasmas generated via energetic laser ablation of graphite. By utilizing hydrodynamic and collisional-radiative simulations, we identify schemes accessible to commercially available tunable lasers for the C I atom, the C II ion, and the C V ion. We then estimate the signal-to-noise ratios yielded by the schemes under reasonable experimental configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser induced fluorescence measurements of ion velocity and temperature of drift turbulence driven sheared plasma flow in a linear helicon plasma device

Using laser induced fluorescence (LIF), radial profiles of azimuthal ion fluid velocity and ion temperature are measured in the controlled shear de-correlation experiment (CSDX) linear helicon plasma device. Ion velocities and temperatures are derived from the measured Doppler broadened velocity distribution functions of argon ions. The LIF system employs a portable, high power (>300 mW), narrowband ({approx}1 MHz) tunable diode laser-based system operating at 668.614 nm. Previous studies in CSDX have shown the existence of a radially sheared azimuthal flow as measured with time delay estimation methods and Mach probes. Here, we report the first LIF measurements of sheared plasma fluid flow in CSDX. Above a critical magnetic field, the ion fluid flow profile evolves from radially uniform to peaked on axis with a distinct reversed flow region at the boundary, indicating the development of a sheared azimuthal flow. Simultaneously, the ion temperature also evolves from a radially uniform profile to a profile with a gradient. Measurements in turbulent and coherent drift wave mode dominated plasmas are compared.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluorescence properties and electron paramagnetic resonance studies of {gamma}-irradiated Sm{sup 3+}-doped oxyfluoroborate glasses

The permanent photoinduced valence manipulation of samarium doped oxyfluoroborate glasses as a function of {gamma}-ray irradiation has been investigated using a steady-state fluorescence and electron paramagnetic resonance techniques. An increase in SrF{sub 2} content in the glass led to the red shift of the peaks in as prepared glass, while in irradiated glasses this led to the decrease in defect formation as well as increase in photoreduction of Sm{sup 3+} to Sm{sup 2+} ion. The energy transfer mechanism of induced permanent photoreduction of Sm{sup 3+} to Sm{sup 2+} ions in oxyfluoroborate glasses has been discussed. The decay analysis shows exponential behavior before irradiation and non-exponential behavior after irradiation. The energy transfer in irradiated glasses increases with the increase in SrF{sub 2} content in the glass and also with the irradiation dose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proton induced quasi-monochromatic x-ray beams for soft x-ray spectroscopy studies and selective x-ray fluorescence analysis

We present the analytical features and performance of an x-ray spectroscopy end station of moderate energy resolution operating with proton-induced quasi-monochromatic x-ray beams. The apparatus was designed, installed and operated at the 5.5 MV Tandem VdG Accelerator Laboratory of the Institute of Nuclear Physics, N.C.S.R. 'Demokritos,' Athens. The setup includes a two-level ultrahigh vacuum chamber that hosts in the lower level up to six primary targets in a rotatable holder; there, the irradiation of pure element materials-used as primary targets-with few-MeV high current ({approx}{mu}A) proton beams produces intense quasi-monochromatic x-ray beams of selectable energy. In the chamber's upper level, a six-position rotatable sample holder hosts the targets considered for x-ray spectroscopy studies. The proton-induced x-ray beam, after proper collimation, is guided to the sample position whereas various filters can be also inserted along the beam's path to eliminate the backscattered protons or/and to absorb selectively components of the x-ray beam. The apparatus incorporates an ultrathin window Si(Li) spectrometer (FWHM 136 eV at 5.89 keV) coupled with low-noise electronics capable of efficiently detecting photons down to carbon K{alpha}. Exemplary soft x-ray spectroscopy studies and results of selective x-ray fluorescence analysis are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional single particle tracking in dense dust clouds by stereoscopy of fluorescent particles

In dense dust clouds of a dusty plasma single particle trajectories are impossible to follow due to occlusion of particles and ambiguities in particle correspondences. By stereoscopic imaging of fluorescent tracer particles, we were able to reconstruct 3D single particle trajectories within dense dust clouds. Several measurements are shown that justify to regard the tracer particles as suitable representatives for the whole dust system. A first analysis of dust density waves in dense clouds already shows that these waves exhibit three-dimensional dynamics at larger wave amplitudes that cannot be resolved by 2D imaging techniques: a broad velocity distribution perpendicular to the oscillation plane due to dust-dust collisions is seen, while the velocity distribution in the oscillation direction is bimodal and shifted due to the bulk wave propagation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗