Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Evaluation of bio-inspired flow fields in a mediated Li-S flow battery for grid energy storage

Lithium-sulfur is a redox flow battery with high energy density for applications in safe, reliable, and lasting scaling of energy. However, lithium-based batteries often encounter platting as a problem thanks to poor Li-ions deposition after cycling. Aiming to reduce this impact, a uniform and continuous flow of ions is needed. On this work, novel bio-inspired flow fields in the electrochemical cell were tested to improve ions flowability and lithium platting control, ultimately enhancing battery performance and life. To secure Li-S efficient, low-cost, and secure energy storage capabilities, we chose a configuration with decamethylferrocene and cobaltocene acting as redox mediators, Li metal as anode and sulfur kept in a separate catholyte reservoir. Flow test and battery results insinuated a beneficial influence of bio-inspired designs in flowing electrolyte uniformly with less pressure and pump power in comparison to other conventional designs used in the industry, with an encouraging ability to approach a cheap, safe, and reliable Li-S grid energy storage.

25 ENERGY STORAGE↗

Pressure Gradient Effects on Hypersonic Cavity Flow Heating

The effect of a pressure gradient on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated in support of the Space Shuttle Return-To-Flight Program. Two blunted-nose test surface geometries were developed, including an expansion plate test surface with nearly constant negative pressure gradient and a flat plate surface with nearly zero pressure gradient. The test surface designs and flow characterizations were performed using two-dimensional laminar computational methods, while the experimental boundary layer state conditions were inferred using the measured heating distributions. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process. Both open-flow and closed-flow cavities were tested on each test surface. The cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary conclusions based on an analysis of only the cavity centerline data indicate that the presence of the pressure gradient did not alter the open cavity heating for laminar-entry/laminar-exit flows, but did raise the average floor heating for closed cavities. The results of these risk-reduction studies will be used to formulate a heating assessment of potential damage scenarios occurring during future Space Shuttle flights.

Everhart, Joel L.↗

Pressure Gradient Effects on Hypersonic Cavity Flow Heating

The effect of a pressure gradient on the local heating disturbance of rectangular cavities tested at hypersonic freestream conditions has been globally assessed using the two-color phosphor thermography method. These experiments were conducted in the Langley 31-Inch Mach 10 Tunnel and were initiated in support of the Space Shuttle Return-To-Flight Program. Two blunted-nose test surface geometries were developed, including an expansion plate test surface with nearly constant negative pressure gradient and a flat plate surface with nearly zero pressure gradient. The test surface designs and flow characterizations were performed using two-dimensional laminar computational methods, while the experimental boundary layer state conditions were inferred using the measured heating distributions. Three-dimensional computational predictions of the entire model geometry were used as a check on the design process. Both open-flow and closed-flow cavities were tested on each test surface. The cavity design parameters and the test condition matrix were established using the computational predictions. Preliminary conclusions based on an analysis of only the cavity centerline data indicate that the presence of the pressure gradient did not alter the open cavity heating for laminar-entry/laminar-exit flows, but did raise the average floor heating for closed cavities. The results of these risk-reduction studies will be used to formulate a heating assessment of potential damage scenarios occurring during future Space Shuttle flights.

Everhart, Joel L.↗

Effect of forward velocity on the noise characteristics of dual-flow jet nozzles

Acoustic results of jet noise tests conducted on scale-model nozzles at a wall isolation facility are presented and analyzed. The test fixture featured a triple-flow system for the purpose of simulating freestream flow around hot dual-flow jet nozzles. Test nozzles included 1/20th scale models of the exhaust system for the JT8D-9 engine, power plant for the Boeing 727 airplane (bypass ratio 1) and of the JT8D-109 refan engine (bypass ratio 2). It was found that overall jet noise is reduced by the forward velocity in proportion to the fifth and sixth power of the relative primary jet velocity. Spectral and directivity characteristics are presented.

Reed, D. H.↗

16-foot transonic tunnel test section flowfield survey

A flow survey has been made of the test section of the NASA Langley Research Center 16-Foot Transonic Tunnel at subsonic and supersonic speeds. The survey was performed using five five-hole pyramid-head probes mounted at 14 inch intervals on a survey rake. Probes were calibrated at freestream Mach numbers from 0.50 to 0.95 and from 1.18 to 1.23. Flowfield surveys were made at Mach numbers from 0.50 to 0.90 and at Mach 1.20. The surveys were made at tunnel stations 130.6, 133.6, and 136.0. By rotating the survey rake through 180 degrees, a cylindrical volume of the test section 4.7 feet in diameter and 5.4 feet long centered about the tunnel centerline was surveyed. Survey results showing the measured test section upflow and sideflow characteristics and local Mach number distributions are presented. The report documents the survey probe calibration techniques used, summarizes the procedural problems encountered during testing, and identifies the data discrepancies observed during the post-test data analysis.

Yetter, J. A.↗

On Hammershock Propagation in a Supersonic Flow Field

A wind tunnel test program was conducted to acquire flow-field data during a supersonic propulsion system compressor stall and inlet unstart sequence. The propulsion system consisted of a mixed-compression, two-dimensional bifurcated inlet coupled to a General Electric J85-13 turbojet engine. The propulsion system was mounted beneath a large flat plate that simulated an underwing propulsion pod installation. Transient flow-field pitot pressure and wing simulator surface static pressure data were acquired during multiple compressor stall and inlet unstart events at a free-stream Mach number of 2.20. The experimental results obtained in this investigation indicate that a supersonic propulsion system compressor stall-inlet unstart transient event adversely affects the surrounding local flow field. The data show that the stall-unstart event affects the surrounding flow field on a millisecond time scale and causes a three-dimensional expanding wave front called a hammershock to propagate outward from the inlet. The flow nearest the wing simulator separates from the surface during the transient event. At the end of the transient event, a distinct process occurs wherein the affected flow field recovers to free-stream conditions and the wing simulator boundary layer reattaches to the flow surface.

Porro, A. Robert↗

Review of IRT CFD & Diffuser Study Results - February 2024 Test Entries

In February 2024, multiple test entries were conducted in the NASA Glenn Research Center Icing Research Tunnel (IRT) to collect CFD validation data, particularly near the facility heat exchanger inlet and outlet planes, measure the boundary layer characteristics in the test section, and survey the diffuser flow field. The CFD validation testing utilized ultrasonic anemometers to acquire 3-components of flow velocity at the inlet and outlet planes across a row of heat exchanger blocks. The test section boundary layer surveys used 18-inch boundary layer rakes centered on each of the four test section surfaces with pitot tubes at turntable centerline. The diffuser study included surveys at three streamwise positions within the diffuser with a 5-hole flow angularity probe at between 3 and 7 lateral locations at a given streamwise position. All IRT diffuser data were acquired with the flow angularity probe at the centerline of the test section. An ultrasonic anemometer was also used in the diffuser to survey near-wall velocity profiles.

Icing↗

Experimental study on heat transfer to supercritical water flowing through tubes

A test facility named SWAMUP (Supercritical Water Multi-Purpose Loop) has been constructed in Shanghai Jiao Tong Univ. to investigate heat transfer and pressure drop through tubes and rod bundles. SWAMUP is a closed loop with operating pressure up to 30 MPa, outlet-water temperature up to 550 deg. C, and mass flow rate up to 5 t/h. In this paper, experimental study has been carried out on heat transfer of supercritical water flowing vertically through tubes (ID=7.6 and 10 mm). A large number of test points in tubes has been obtained with a wide range of heat flux (200-1500 kw/m{sup 2}) and mass flux (450-2000 kg/m{sup 2}s). Test results showed that heat transfer deterioration (HTD) caused by buoyancy effect only appears in upward flow and HTD caused by acceleration effect appears both in upward flow and downward flow. The heat transfer coefficients (HTC) produced in tube tests were compared with existing heat transfer correlations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flow Quality Studies of the NASA Glenn Research Center Icing Research Tunnel Circuit (1995 Tests)

The purpose of conducting the flow-field surveys described in this report was to more fully document the flow quality in several areas of the tunnel circuit in the NASA Glenn Research Center Icing Research Tunnel. The results from these surveys provide insight into areas of the tunnel that were known to exhibit poor flow quality characteristics and provide data that will be useful to the design of flow quality improvements and a new heat exchanger for the facility. An instrumented traversing mechanism was used to survey the flow field at several large cross sections of the tunnel loop over the entire speed range of the facility. Flow-field data were collected at five stations in the tunnel loop, including downstream of the fan drive motor housing, upstream and downstream of the heat exchanger, and upstream and downstream of the spraybars located in the settling chamber upstream of the test section. The data collected during these surveys greatly expanded the data base describing the flow quality in each of these areas. The new data matched closely the flow quality trends recorded from earlier tests. Data collected downstream of the heat exchanger and in the settling chamber showed how the configuration of the folded heat exchanger affected the pressure, velocity, and flow angle distributions in these areas. Smoke flow visualization was also used to qualitatively study the flow field in an area downstream of the drive fan and in the settling chamber/contraction section.

Arrington, E. Allen↗

Simulation of 3-D Nonequilibrium Seeded Air Flow in the NASA-Ames MHD Channel

The 3-D nonequilibrium seeded air flow in the NASA-Ames experimental MHD channel has been numerically simulated. The channel contains a nozzle section, a center section, and an accelerator section where magnetic and electric fields can be imposed on the flow. In recent tests, velocity increases of up to 40% have been achieved in the accelerator section. The flow in the channel is numerically computed us ing a 3-D parabolized Navier-Stokes (PNS) algorithm that has been developed to efficiently compute MHD flows in the low magnetic Reynolds number regime: The MHD effects are modeled by introducing source terms into the PNS equations which can then be solved in a very efficient manner. The algorithm has been extended in the present study to account for nonequilibrium seeded air flows. The electrical conductivity of the flow is determined using the program of Park. The new algorithm has been used to compute two test cases that match the experimental conditions. In both cases, magnetic and electric fields are applied to the seeded flow. The computed results are in good agreement with the experimental data.

Gupta, Sumeet↗

Epsilon Metal Summary Report Fiscal Year 2011

The Epsilon-metal (ε-metal) phase was selected in FY 2009 as a potential waste form to for immobilizing the noble metals found in the undissolved solids + aqueous stream, and the soluble Tc from ion-exchange process, each resulting from proposed aqueous reprocessing. ε-metal phase is observed in used nuclear fuel and the natural reactors of Oklobono in Gabon, where the long-term corrosion behavior was demonstrated. This makes ε-metal a very attractive waste form. Last fiscal year, ε-metal was successfully fabricated by combining the five-metals, Mo, Ru, Rh, Pd and Re (surrogate for Tc), into pellets followed by consolidation with an arc melter. The arc melter produced fully dense samples with the epsilon structure. However, some chemistry differences were observed in the microstructure that resulted in regions rich in Re and Mo, and others rich in Pd, while Ru and Rh remained fairly constant throughout. This year, thermal stability (air), and corrosion testing of the samples fabricated by arc melting were the main focus for experimental work. Thermal stability was measured with a differential scanning calorimeter - thermogravimetric analyzer, by both ramp heating as well as step heating. There is clear evidence during the ramp heating experiment of an exothermic event + a weight loss peak both beginning at ≈700°C. Step heating showed an oxidation event at ≈690°C with minimal weight gain that occurs just before the weight loss event at 700°C. The conclusion being that the e-metal begins to oxidize and then become volatile. These findings are useful for considering the effects of voloxidation process. Three different pellets were subjected to electrochemical testing to study the corrosion behavior of the epsilon-metal phase in various conditions, namely acidic, basic, saline, and inert. Test was done according to an interim procedure developed for the alloy metal waste form. First an open circuit potential was measured, followed by linear polarization sweeps. The linear polarization sweep range was the Tafel equation was fit to the linear polarization sweep data to determine the corrosion rate of each pellet in each test solution. The average calculated corrosion rates of the three pellets according to solution conditions were: -1.91 x 10 -4 mm/yr (0.001 M NaOH), -1.48 x 10 -3 mm/yr (0.01 M NaCl), -8.77 x 10 -4 mm/yr (0.001 M H 2 SO 4 ), -2.09 x 10 -3 mm/yr (0.001 M NaOH + 0.01 M NaCl), and -1.54 x 10 -3 mm/yr (0.001 M H 2 SO 4 + 0.01 M NaCl). Three single-pass flow through (SPFT) test were conducted at a flow rate of 10 ml/day, at 90°C, and pH of 2.5, 7.0, and 9.0 for up to 322 days. Results of the tests indicate that dissolution rates were 5 x 10 -4 g m -2 d -1 at pH 9.0, 1.2 x 10 -4 g m -2 d -1 at pH 7.0, and 2 x 10 -4 g m -2 d -1 at pH 2.5. The sample used for the pH 7.0 SPFT test contains extra Re compared to samples used for the other two SPFT test, which came from a single pellet. The corrosion data measured this year indicate that the ε-metal phase is chemically durable. The two chemically different phases, but structurally the same, behave differently during dissolution according to the microstructure changes observed in both the electrochemical and in SPFT test. Characterization of the test specimens after testing suggests that the dissolution is complex and involves oxidative dissolution followed by precipitation of both oxide and metallic phases. These data suggest that the dissolution in the electrochemical and SPFT tests is different; a process that needs further investigation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Field test and simulation evaluation of variable refrigerant flow systems performance

Our study aims to compare the performance of a Variable Refrigerant Flow (VRF) system with a Roof Top Unit, (RTU) and a variable-air-volume (VAV) system through field tests and energy simulations. The field test was conducted in as similar conditions as possible between the two systems, such as the installation and operating environments of heating, the ventilation and air conditioning (HVAC) system, including internal heat gain and outdoor conditions, including buildings to compare the performance of the two systems accurately. A VRF system and RTU were installed at the test building located in Oak Ridge, Tennessee, in the USA. The same internal heat gain was generated at the same operating time of the two systems using lighting, electric heaters, and humidifiers inside the building. The HVAC system was alternately operated between cooling and heating operations to acquire energy performance data and to compare energy usage. Furthermore, an hourly building energy simulation model was developed with regard to the VRF system and RTU, and then the model was calibrated using actual measured data. Then, annual energy consumption of the two systems were compared and analyzed using the calibrated model. Moreover, additional analysis was conducted when the controlled discharge air temperature in the RTU was changed. The field test result showed that when energy consumptions of two systems were compared at the same outdoor conditions, using the weather-normalized model, the VRF system exhibited an energy reduction of approximately 17% during cooling operation and of approximately 74% during heating operations. A comparison on the annual energy consumption using simulations showed that the VRF system reduced energy consumption more than that of the RTU by 60%. Furthermore, when the discharge air temperature in the RTU was controlled according to the outdoor air temperature, energy consumption of the RTU was reduced by 6% in cooling operations and by 18% in heating operation. As a result, energy consumption of the VRF system was reduced by more than that of the RTU by 55% approximately.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Forebody Tangential Slot Blowing on an Aircraft Geometry

The effect of forebody tangential slot blowing on the flowfield about an F/A-18 aircraft is investigated numerically using solutions of the Navier-Stokes equations. Computed solutions are obtained for an aircraft geometry which includes the fuselage, a wing with deflected leading-edge flap, empennage, and a faired-over engine inlet. The computational slot geometry corresponds to that used in full-scale wind-tunnel tests. Solutions are computed using flight test conditions and jet mass flow ratios equivalent to wind-tunnel test conditions. The effect of slot location is analyzed by computing two nontime-accurate solutions with a 16-in. slot located 3 in. and 11 in. aft of the nose of the aircraft. These computations resolve the trends observed in the full-scale wind-tunnel test data. The flow aft of the leading-edge extension vortex burst is unsteady. A time-accurate solution is obtained to investigate the flow characteristics aft of the vortex burst, including the effect of blowing on tail buffet.

Gee, Ken↗

Experimental and Numerical Investigation of Air Radiation in Superorbital Expanding Flow

To investigate air radiation in expanding flows and provide experimental data for validating associated computational models, experiments were conducted in the X2 expansion tunnel facility at the Centre for Hypersonics of the University of Queensland. A 54deg turning angle wedge model was employed to generate steady expanding flows with in flow total enthalpies of 50.7, 63.4 and 75.4 MJ/kg. VUV spectra from 118 to 180 nm were acquired across the wedge at three equispaced distances away from the top of the model, as well as through its top surface. High speed filtered images were also obtained by coupling a Shimadzu 1 MHz high speed camera to a bandpass filter to obtain calibrated images of the 777 nm oxygen triplet. Both the across-wedge VUV spectra and filtered images of the 777 nm atomic oxygen were compared with NEQAIR simulations, which were performed using flow field data from two-dimensional CFD simulations with two-temperature 11-species air chemistry utilising the in-house Navier-Stokes flow solver Eilmer3. Data extracted from consecutive frames of the filtered high speed images confirmed up to 8 s of available test time for the flow conditions tested. For the strongly radiating 149 and 174 nm atomic nitrogen lines, large disagreement between experimental data and NEQAIR predictions can be observed from the start of the expansion fan where the electron-ion recombination process commences. The spatial extent, or spans of the radiance profiles of the 149 and 174 nm N lines are significantly underpredicted by NEQAIR, and are very close to those of N, N+ and electron number density profiles, which follow that of flow density. The electron-ion recombination process is proposed as the main reason for these discrepancies. The comparisons between NEQAIR simulations and filtered images of the 777 nm oxygen triplet show good agreement in the post-shock compression region and the start of the expansion fan for the 63.4 MJ/kg condition, but with up to a factor of three overprediction by NEQAIR further downstream, which is attributed to electron-impact excitation. Similar trends are found with the 75.4 MJ/kg condition, with reduced level of agreement in the compression region, which can be due to uncertainties in inflow condition.

expansion tube↗

Experimental and Numerical Investigation of Air Radiation in Superorbital Expanding Flow

To investigate air radiation in expanding flows and provide experimental data for validating associated computational models, experiments were conducted in the X2 expansion tunnel facility at the Centre for Hypersonics of the University of Queensland. A 54 turning angle wedge model was employed to generate steady expanding flows with in flow total enthalpies of 50.7, 63.4 and 75.4 MJkg. VUV spectra from 118 to 180 nm were acquired across the wedge at three equispaced distances away from the top of the model, as well as through its top surface. High speed filtered images were also obtained by coupling a Shimadzu 1 MHz high speed camera to a bandpass filter to obtain calibrated images of the 777 nm oxygen triplet. Both the across-wedge VUV spectra and filtered images of the 777 nm atomic oxygen were compared with NEQAIR simulations, which were performed using flow field data from two-dimensional CFD simulations with two-temperature 11-species air chemistry utilizing the in-house Navier-Stokes flow solver Eilmer3. Data extracted from consecutive frames of the filtered high speed images confirmed up to 8 s of available test time for the flow conditions tested. For the strongly radiating 149 and 174 nm atomic nitrogen lines, large disagreement between experimental data and NEQAIR predictions can be observed from the start of the expansion fan where the electron-ion recombination process commences. The spatial extent, or spans of the radiance profiles of the 149 and 174 nm N lines are significantly under predicted by NEQAIR, and are very close to those of N, N+ and electron number density profiles, which follow that of flow density. The electron-ion recombination process is proposed as the main reason for these discrepancies. The comparisons between NEQAIR simulations and filtered images of the 777 nm oxygen triplet show good agreement in the post-shock compression region and the start of the expansion fan for the 63.4 MJkg condition, but with up to a factor of three over prediction by NEQAIR further downstream, which is attributed to electron-impact excitation. Similar trends are found with the 75.4 MJkg condition, with reduced level of agreement in the compression region, which can be due to uncertainties in inflow condition.

Earth entry↗

Integrated flow and structural modeling for rocket engine component test facility propellant systems

A set of PC-based computational Dynamic Fluid Flow Simulation models is presented for modeling facility gas and cryogenic systems. Data obtained provide important information regarding performance envelope parameters for the facility using different engine components; time-dependent valve setting for controlling steady-state, quasi-steady state, and transient profiles; optimum facility pipe and pipe component sizes and parameters; momentum transfer loads; and fluid conditions at critical points. A set of COSMIC NASTRAN-based finite element models is also presented to evaluate the loads and stresses on test facility piping systems from fluid and gaseous effects, thermal chill down, and occasional wind loads. The models are based on Apple Macintosh software which makes it possible to change numerous parameters.

Dequay, L.↗

Plug20 Test Report

This report documents a test of aircraft exhaust nozzle designs applicable to commercial supersonic aircraft as envisioned in the 2025-2035 time frame. The test is primarily intended to provide data about the noise such aircraft would produce during landing and takeoff (LTO) operation, specifically the jet noise component of this noise. The tests were conducted at the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory in March 2020. The tests used the High-Flow Jet Exhaust Rig in the Nozzle Acoustic Test Rig which simulates the flow from a dual-stream turbofan engine in a flight stream. Seven exhaust configurations were tested with various combinations of internal mixer and external plug, and covered engine cycles having nozzle pressures from 1.5 to 2.3 at a flight speed of Mach 0.3. A few unheated flow conditions were also tested to tie results to other baseline test results. Data acquired and included in this report are 1) far-field acoustic spectra, 2) phased array measurements of noise source distributions, and 3) background-oriented schlieren of the flow near the nozzles. These data, along with the nozzle geometry in CAD format, are given as Appendices and are available online.

Jet noise↗

Aerothermal Ground Testing of Flexible Thermal Protection Systems for Hypersonic Inflatable Aerodynamic Decelerators

Flexible TPS development involves ground testing and analysis necessary to characterize performance of the FTPS candidates prior to flight testing. This paper provides an overview of the analysis and ground testing efforts performed over the last year at the NASA Langley Research Center and in the Boeing Large-Core Arc Tunnel (LCAT). In the LCAT test series, material layups were subjected to aerothermal loads commensurate with peak re-entry conditions enveloping a range of HIAD mission trajectories. The FTPS layups were tested over a heat flux range from 20 to 50 W/cm with associated surface pressures of 3 to 8 kPa. To support the testing effort a significant redesign of the existing shear (wedge) model holder from previous testing efforts was undertaken to develop a new test technique for supporting and evaluating the FTPS in the high-temperature, arc jet flow. Since the FTPS test samples typically experience a geometry change during testing, computational fluid dynamic (CFD) models of the arc jet flow field and test model were developed to support the testing effort. The CFD results were used to help determine the test conditions experienced by the test samples as the surface geometry changes. This paper includes an overview of the Boeing LCAT facility, the general approach for testing FTPS, CFD analysis methodology and results, model holder design and test methodology, and selected thermal results of several FTPS layups.

Bruce, Walter E., III↗