Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Inverter Design with High Short-Circuit Fault Current Contribution to Enable Legacy Overcurrent Protection for Islanded Microgrids

The resiliency offered by a microgrid may be lost if the microgrid is not properly protected during short-circuit faults inside its boundaries. Many studies conclude that protecting microgrids in islanded mode is very challenging due to the limited short-circuit capability of distributed energy resources (DERs). The limited short-circuit capability of DERs typically inhibits the use of reliable and affordable overcurrent protective devices in microgrids. Although extensive research on microgrid protection is available in the literature, to date this research has not led to a cost-effective, commercially available relay that effectively tackles the challenges of microgrid protection. This work proposes hardware modifications to enhance the current contribution of an energy storage inverter with the objective of enabling the use of legacy overcurrent protection for islanded microgrids. This paper demonstrates through experimental results that few modifications are required in the inverter to significantly enhance its current contribution. In this study, a three-phase energy storage inverter was modified to provide three times its rated current during three-phase faults, which proved sufficient current for enough time to enable fuse-relay, and relay-to-relay coordination. The proposed modifications effectively increase the current contribution of the inverter, which is a promising advancement to allow the adoption of overcurrent protective devices for protecting microgrids.

Ferrari Maglia, Max↗

Phasor-Domain Modeling of Inverter Based Resources Considering Unbalanced Grid Faults

A significant increase in inverter-based distributed energy resources (DERs) is expected in distribution systems of the near future. The latest phasor modeling approach of DERs with emerging control technologies can capture relevant dynamics in large-scale three-phase distribution systems with unbalanced construction. However, there is a lack of appropriate phasor models to deal with unbalanced fault scenarios. As such, this paper describes per-phase phasor modeling approach appropriate for unbalanced grid disturbance studies in distribution systems with high penetration of DERs. The overall modeling performance of representative DERs is simulated in phasor domain GridLAB-D environment and validated against controller hardware-in-the loop (CHIL) testing or electromagnetic transient (EMT) based switching model simulation in PSCAD with test cases including different unbalanced grid faults. The high accuracy retained from the simulation verifies the effectiveness of the proposed phasor modeling approach considering interactions between positive and negative sequence signals.

Chen, Zhe↗

Exploring Capability of Multimodal Foundation Model for Image-based Fault Detection of Photovoltaic Modules

Multimodal Foundation Model (MFM), like ChatGPT and Gemini, have emerged as powerful tools for their exceptional natural language processing capabilities and their emerging potential in image analysis. This paper investigates the application of MFMs for photovoltaic (PV) fault detection through image analysis, focusing on ChatGPT 4.0 and Gemini 1.5 Pro. Three types of PV images and the corresponding common PV faults are detected: bird droppings using visible images, cell cracks via electroluminescence (EL) images, and hotspots using infrared (IR) images. Among the two models, Gemini 1.5 Pro demonstrated superior performance, achieving near-perfect results with an average F1 score of 0.97, consistently outperforming ChatGPT 4.0 in accuracy and reliability. Unlike traditional machine learning (ML) models, MFMs can operate in a zero shot manner that does not require additional training by the user, and the input images are not limited by size, angle, scope, or PV technology. The strong adaptability and user-friendliness make MFM a promising tool for analyzing PV images and advancing health monitoring for PV modules.

Li, Baojie↗

Fault-Tolerant Deep Learning Cache with Hash Ring for Load Balancing in HPC Systems

Large-scale DL on HPC systems like Frontier and Summit uses distributed node-local caching to address scalability and performance challenges. However, as these systems grow more complex, the risk of node failures increases, and current caching approaches lack fault tolerance, jeopardizing large-scale training jobs. We analyzed six months of SLURM job logs from Frontier and found that over 30% of jobs failed after an average of 75 minutes. To address this, we propose fault-tolerance strategies that recache data lost from failed nodes using a hash ring technique for balanced data recaching in the distributed node-local caching, reducing reliance on the PFS. Our extensive evaluations on Frontier showed that the hash ring-based recaching approach reduced training time by approximately 25% compared to the approach that redirects I/O to the PFS after node failures and demonstrated effective load balancing of training data across nodes.

Lee, Seoyeong↗

Diagnosis of Performance Faults in LargeScale MPI Applications via Probabilistic Progress-Dependence Inference

Debugging large-scale parallel applications is challenging. Most existing techniques provide little information about failure root causes. Further, most debuggers significantly slow down program execution, and run sluggishly with massively parallel applications. This paper presents a novel technique that scalably infers the tasks in a parallel program on which a failure occurred, as well as the code in which it originated. Our technique combines scalable runtime analysis with static analysis to determine the least-progressed task(s) and to identify the code lines at which the failure arose. We present a novel algorithm that infers probabilistically progress dependence among MPI tasks using a globally constructed Markov model that represents tasks' control-flow behavior. In comparison to previous work, our algorithm infers more precisely the least-progressed task. Further, we combine this technique with static backward slicing analysis, further isolating the code responsible for the current state. A blind study demonstrates that our technique isolates the root cause of a concurrency bug in a molecular dynamics simulation, which only manifests itself at 7,996 tasks or more. We extensively evaluate fault coverage of our technique via fault injections in 10 HPC benchmarks and show that our analysis takes less than a few seconds on thousands of parallel tasks.

97 MATHEMATICS AND COMPUTING↗

Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines

Grid-forming wind turbines must be able to re-energize transmission branches, motor loads, unbalanced loads, and power electronics loads following a blackout. Further, they must ride through faults that can arise during restoration. To tackle these challenges, this paper sets forth a grid-forming control strategy for wind turbines using doubly-fed induction generators (DFIGs). In particular, a special set of feedforward control loops are engineered to mitigate the impacts of restoration transients as well as symmetrical and asymmetrical faults on the regulation of DFIG rotor currents and stator voltages. This paper also leverages two-axis anti-windup regulators to bound two-axis voltage and current commands within ratings. As a result, the controller performance is demonstrated via a high-fidelity simulation model of a notional wind-dominant grid.

17 WIND ENERGY↗

Enabling Grid-Forming Control with Fault Ride-Through in Unbalanced Distribution Networks

Distribution networks are often unbalanced, causing oscillatory responses in inverter control designed for balanced conditions. Here, to address this problem, this paper proposes a novel time-domain transformation appropriate for inverter control and enables the decomposition of three-phase unbalanced signals into constant positive and negative components. Relations useful for calculating unbalanced active and reactive power are derived from first principle, providing insight into vector products of unbalanced three-phase signals. Furthermore, a grid-forming control effective under unbalanced conditions is developed, which delivers superior performance while meeting UNIFI1 specifications for grid-forming control under unbalanced conditions. specifications applicable to category 4 inverter-based resource, like setting and regulating frequency/voltage, providing voltage support, sharing active power, injecting negative sequence current, and riding through faults. A current limiter is proposed for safe fault ride-through and integrates with the grid-forming control featuring frequency/voltage droop controllers and current and voltage control loops. The transformation of interconnected inverters is formulated and stability of the proposed control analyzed to support robust parameter selections. The effectiveness of the proposed transformation and grid-forming control is demonstrated through analytical results and real-time simulation of a IEEE 123 distribution network on the Real-Time Digital Simulator. Comparison with existing methods shows that the proposed strategy satisfies the UNIFI specifications with a much better performance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Parallel reduction to hessenberg form with algorithm-based fault tolerance

This paper studies the resilience of a two-sided factorization and presents a generic algorithm-based approach capable of making two-sided factorizations resilient. We establish the theoretical proof of the correctness and the numerical stability of the approach in the context of a Hessenberg Reduction (HR) and present the scalability and performance results of a practical implementation. Our method is a hybrid algorithm combining an Algorithm Based Fault Tolerance (ABFT) technique with diskless checkpointing to fully protect the data. We protect the trailing and the initial part of the matrix with checksums, and protect finished panels in the panel scope with diskless checkpoints. Compared with the original HR (the ScaLAPACK PDGEHRD routine) our fault-tolerant algorithm introduces very little overhead, and maintains the same level of scalability. We prove that the overhead shows a decreasing trend as the size of the matrix or the size of the process grid increases.

Computer Science↗

Numerical Modeling of CO 2 and Brine Leakage through Open Fracture in a Fault Zone: Open Channel Flow or Darcy Flow

Understanding fluids migration and leakage risk along the fault zone is necessary to guarantee the safety of CO 2 geological storage. The validity of Darcy’s law gets challenged in dealing with the flow in open fractures since the occurring of turbulence flow. In this study, we develop a 2D model with usage of T2Well, an integrated wellbore-reservoir simulator, to investigate the leakage problem along open fractures which are embedded in a fault zone from the deep injection reservoir to shallow aquifers. The results record a positive feedback of gas expansion and pressure response in fracture, which causes a quick downward propagation of highly gas saturated zone from the top of fracture and an easy gas breakthrough in the shallower aquifers. The decreasing of aperture size of fracture significantly enhances the leakage rates in fracture, but with less influences as aperture increases. In comparison, the Equivalent Porous Media models show a good approximation with the momentum model of large apertures but poor for the small one. Nevertheless, the differences are small in terms of final CO 2 distribution among various aquifers, suggesting that Darcy’s law may be still “effective” in solving flow problem along fractures in a constant injection system at a large time scale.

58 GEOSCIENCES↗

Data-Driven Protection Software to classify fault locations by protective zone in distribution systems with high PV penetration

The software contains (a) the source codes to generate Point-on-Wave (PoW) transient data for any feeder model in Alternative Transient Program (ATP) format. Codes provide options to change different steady state settings, including the loading condition and PV capacity and transient state setting like faults type, location and initiation time (b) data post-processing source code to converted data from native format to COMTRADE, csv, HDF5 (c) Docker container to train CNN to classify fault locations by protective zone. The container takes dataset and other training parameters (sampling rate, training epochs, batch size etc) as input to train CNN. The container writes back the trained CNN model, training and testing metrics and plots to the local workstation

Ramesh, Meghana↗

Blockchain-based fault tolerant grid operations system

To maintain/improve the distribution system fault-tolerance for a grid with high penetration of distributed energy resources requires improvement, Blockchain can add value to improve fault-tolerant grid operations. That can be achieved using blockchain's core features of distributed consensus-based decision-making process and immutability.

Bereta dos Reis, Fernando↗

Ground Motion and Intraevent Variability from 3D Deterministic Broadband (0-7.5 Hz) Simulations along a Nonplanar Strike-Slip Fault

In the article, we model deterministic broadband (-7.5 Hz) ground motion from an M w 7.1 bilateral strike-slip earthquake scenario with dynamic rupture propagation along a rough-fault topography embedded in a medium including small-scale velocity and density perturbations. Spectral accelerations (SAs) at periods 0.2-3 s and Arias intensity durations show a similar distance decay (at the level of 1-2 interevent standard deviations above the median) when compared to Next Generation Attenuation-West2 (NGA)-West2 ground-motion prediction equations (GMPEs) using a Q(f) power-law exponent of 0.6-0.8 above 1 Hz in models with a minimum V S of 750 m/s. With a trade-off from Q(f), the median ground motion is slightly increased by scattering from statistical models of small-scale heterogeneity with standard deviation (σ) of the perturbations at the lower end of the observed range (5%) but reduced by scattering attenuation at the upper end (10%) when using a realistic 3D background velocity model. The ground-motion variability is strongly affected by the addition of small-scale media heterogeneity, reducing otherwise large values of intraevent standard deviation closer to those of empirical observations. These simulations generally have intraevent standard deviations for SAs lower than the GMPEs for the modeled bandwidth, with an increasing trend with distance (most pronounced in low-to-moderate scattering media) near the level of observations at distances greater than 35 km from the fault. Durations for the models follow the same increasing trend with distance, in which σ~5% produces the best match to GMPE values. We find that a 3D background-velocity model reduces the pulse period into the expected range by breaking up coherent waves from directivity, generating a lognormal distribution of ground-motion residuals. These results indicate that a strongly heterogeneous medium is needed to produce realistic deterministic broadband ground motions. Finally, the addition of a thin surficial layer with low, frequency-independent Q in the model (with a minimum V S of 750 m/s) controls the high-frequency decay in energy, as measured by the parameter κ, that may be necessary to include as simulations continue to extend to higher frequencies.

Geochemistry & Geophysics↗

Incorporating Full Elastodynamic Effects and Dipping Fault Geometries in Community Code Verification Exercises for Simulations of Earthquake Sequences and Aseismic Slip (SEAS)

ABSTRACT Numerical modeling of earthquake dynamics and derived insight for seismic hazard relies on credible, reproducible model results. The sequences of earthquakes and aseismic slip (SEAS) initiative has set out to facilitate community code comparisons, and verify and advance the next generation of physics-based earthquake models that reproduce all phases of the seismic cycle. With the goal of advancing SEAS models to robustly incorporate physical and geometrical complexities, here we present code comparison results from two new benchmark problems: BP1-FD considers full elastodynamic effects, and BP3-QD considers dipping fault geometries. Seven and eight modeling groups participated in BP1-FD and BP3-QD, respectively, allowing us to explore these physical ingredients across multiple codes and better understand associated numerical considerations. With new comparison metrics, we find that numerical resolution and computational domain size are critical parameters to obtain matching results. Codes for BP1-FD implement different criteria for switching between quasi-static and dynamic solvers, which require tuning to obtain matching results. In BP3-QD, proper remote boundary conditions consistent with specified rigid body translation are required to obtain matching surface displacements. With these numerical and mathematical issues resolved, we obtain excellent quantitative agreements among codes in earthquake interevent times, event moments, and coseismic slip, with reasonable agreements made in peak slip rates and rupture arrival time. We find that including full inertial effects generates events with larger slip rates and rupture speeds compared to the quasi-dynamic counterpart. For BP3-QD, both dip angle and sense of motion (thrust versus normal faulting) alter ground motion on the hanging and foot walls, and influence event patterns, with some sequences exhibiting similar-size characteristic earthquakes, and others exhibiting different-size events. These findings underscore the importance of considering full elastodynamics and nonvertical dip angles in SEAS models, as both influence short- and long-term earthquake behavior and are relevant to seismic hazard.

Geochemistry & Geophysics↗

Basement Fault Activation before Larger Earthquakes in Oklahoma and Kansas

Oklahoma and Kansas experienced unprecedented seismic activity over the past decade due to earthquakes associated with unconventional hydrocarbon development. The modest natural seismicity and incomplete knowledge of the fault network in the region made it difficult to anticipate the locations of earthquakes with larger magnitudes (M w ≥ 4). Here, we show that monitoring of microearthquakes at regional scale using a pretrained neural phase picker and an earthquake relocation algorithm can illuminate unknown fault structures, and deliver information that can be synthesized for earthquake forecasting. We found that 80% of the larger earthquakes that occurred in the past decade could have been anticipated based on the spatial extent of the seismicity clusters that were formed before these earthquakes occurred. We also found that once a seismicity cluster with a length scale enough to host a larger earthquake was formed, there was a ~5% chance that it would host one or more larger earthquakes within a year. This probability is nearly an order of magnitude higher than one based on Gutenberg–Richter statistics and preceding seismicity. Applying our approach in practice can provide critical information on seismic hazards for risk management and regulatory decision making.

58 GEOSCIENCES↗

Curation of Ground-Truth Validated Benchmarking Datasets for Fault Detection & Diagnostics Tools

Fault detection and diagnostics (FDD) analytical tools for heating, ventilation and air conditioning (HVAC) systems represent one of the most active areas of smart building technology development. A diversity of techniques is used for FDD analytics, spanning physical models, black box, and rule-based approaches, and researchers continuously strive to develop improved algorithms. With FDD algorithm numbers now in the hundreds, there is a need for performance evaluation of these algorithms in order to assess improvements, improve costeffectiveness, and to prioritize investment in the further development of these technologies. A persistent challenge of FDD advance has been the lack of common datasets to benchmark the performance accuracy of FDD algorithms. This paper summarizes the successful curation of HVAC operational data, paired with validated ground-truth information regarding the presence and absence of faults. The current dataset, consisting of both simulation and experimental data, will evolve to include a larger set of HVAC systems with the objective of creating the largest publicly available dataset to be used by FDD developers, users, and researchers to compare and contrast performance accuracy across FDD algorithms, helping to drive improvements that will spur greater market adoption of FDD tools. Furthermore, in order to avoid previously observed issues with contributed datasets and ensure high quality and consistency of future submissions, the development of data validation and ground-truth assessment protocol is detailed in this study.

Casillas, Armando↗

rMPI : increasing fault resiliency in a message-passing environment.

As High-End Computing machines continue to grow in size, issues such as fault tolerance and reliability limit application scalability. Current techniques to ensure progress across faults, like checkpoint-restart, are unsuitable at these scale due to excessive overheads predicted to more than double an applications time to solution. Redundant computation, long used in distributed and mission critical systems, has been suggested as an alternative to checkpoint-restart on its own. In this paper we describe the rMPI library which enables portable and transparent redundant computation for MPI applications. We detail the design of the library as well as two replica consistency protocols, outline the overheads of this library at scale on a number of real-world applications, and finally outline the significant increase in an applications time to solution at extreme scale as well as show the scenarios in which redundant computation makes sense.

99 GENERAL AND MISCELLANEOUS↗

Design, Fabrication and Testing of a Superconducting Fault Current Limiter (SFCL)

The purpose of this project was to conduct R&D on specified components and provide technical design support to a SuperPower team developing a high temperature superconducting Fault Current Limiter (SFCL). ORNL teamed with SuperPower, Inc. on a Superconductivity Partnerships with Industry (SPI) proposal for the SFCL that was submitted to DOE and approved in FY 2003. A contract between DOE and SuperPower, Inc. was signed on July 14, 2003 to design, fabricate and test the SFCL. This device employs high temperature superconducting (HTS) elements and SuperPower's proprietary technology. The program goal was to demonstrate a device that will address a broad range of the utility applications and meet utility industry requirements. This DOE-sponsored Superconductivity Partnership with Industry project would positively impact electric power transmission reliability and security by introducing a new element in the grid that can significantly mitigate fault currents and provide lower cost solutions for grid protection. The project will conduct R&D on specified components and provide technical design support to a SuperPower-led team developing a SFCL as detailed in tasks 1-5 below. Note the SuperPower scope over the broad SPI project is much larger than that shown below which indicates only the SuperPower tasks that are complementary to the ORNL tasks. SuperPower is the Project Manager for the SFCL program, and is responsible for completion of the project on schedule and budget. The scope of work for ORNL is to provide R&D support for the SFCL in the following four broad areas: (1) Assist with high voltage subsystem R&D, design, fabrication and testing including characterization of the general dielectric performance of LN2 and component materials; (2) Consult on cryogenic subsystem R&D, design, fabrication and testing; (3) Participate in project conceptual and detailed design reviews; and (4) Guide commercialization by participation on the Technical Advisory Board (TAB). SuperPower's in-kind work for the SFCL will be provided in the following areas: (1) Work with ORNL to develop suitable test platforms for the evaluation of subsystems and components; (2) Provide cryogenic and high voltage subsystem designs for evaluation; (3) Lead the development of the test plans associated with the subsystem and components and participate in test programs at ORNL; and (4) Based on the test results, finalize the subsystem and component designs and incorporate into the respective SFCL prototypes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Creating dynamic equivalent PV circuit models with impedance spectroscopy for arc-fault modeling.

Article 690.11 in the 2011 National Electrical Code{reg_sign} (NEC{reg_sign}) requires new photovoltaic (PV) systems on or penetrating a building to include a listed arc fault protection device. Currently there is little experimental or empirical research into the behavior of the arcing frequencies through PV components despite the potential for modules and other PV components to filter or attenuate arcing signatures that could render the arc detector ineffective. To model AC arcing signal propagation along PV strings, the well-studied DC diode models were found to inadequately capture the behavior of high frequency arcing signals. Instead dynamic equivalent circuit models of PV modules were required to describe the impedance for alternating currents in modules. The nonlinearities present in PV cells resulting from irradiance, temperature, frequency, and bias voltage variations make modeling these systems challenging. Linearized dynamic equivalent circuits were created for multiple PV module manufacturers and module technologies. The equivalent resistances and capacitances for the modules were determined using impedance spectroscopy with no bias voltage and no irradiance. The equivalent circuit model was employed to evaluate modules having irradiance conditions that could not be measured directly with the instrumentation. Although there was a wide range of circuit component values, the complex impedance model does not predict filtering of arc fault frequencies in PV strings for any irradiance level. Experimental results with no irradiance agree with the model and show nearly no attenuation for 1 Hz to 100 kHz input frequencies.

99 GENERAL AND MISCELLANEOUS↗