Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaluation platform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study, as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

Validation and Simulation of Ares I Scale Model Acoustic Test - 3 - Modeling and Evaluating the Effect of Rainbird Water Deluge Inclusion

The Ares I Scale Model Acoustics Test (ASMAT) is a series of live-fire tests of scaled rocket motors meant to simulate the conditions of the Ares I launch configuration. These tests have provided a well documented set of high fidelity measurements useful for validation including data taken over a range of test conditions and containing phenomena like Ignition Over-Pressure and water suppression of acoustics. Building on dry simulations of the ASMAT tests with the vehicle at 5 ft. elevation (100 ft. real vehicle elevation), wet simulations of the ASMAT test setup have been performed using the Loci/CHEM computational fluid dynamics software to explore the effect of rainbird water suppression inclusion on the launch platform deck. Two-phase water simulation has been performed using an energy and mass coupled lagrangian particle system module where liquid phase emissions are segregated into clouds of virtual particles and gas phase mass transfer is accomplished through simple Weber number controlled breakup and boiling models. Comparisons have been performed to the dry 5 ft. elevation cases, using configurations with and without launch mounts. These cases have been used to explore the interaction between rainbird spray patterns and launch mount geometry and evaluate the acoustic sound pressure level knockdown achieved through above-deck rainbird deluge inclusion. This comparison has been anchored with validation from live-fire test data which showed a reduction in rainbird effectiveness with the presence of a launch mount.

Strutzenberg, Louise L.↗

Crew Health and Performance Integrated Data Architecture (CHP-IDA) Project

BACKGROUND: Future Human Exploration missions introduce a new paradigm as crews move further from the resupply and near real-time ground support typical of Low Earth Orbit missions today. Without immediate support from ground-based personnel, exploration crews will be more reliant on inflight data and technology to respond to emergencies and anomalies. A data architecture to support a new generation of technologies, employing advanced analytical and predictive modeling techniques, is needed to enable crew autonomy. OVERVIEW: The Crew Health and Performance Integrated Data Architecture (CHP-IDA) project funded by NASA’s Exploration Medical Integrated Product Team (XMIPT) is laying a foundation for future in-flight informatics by providing a back-end architecture for collecting, storing, and integrating multiple sources of data generated by and around the crew. CHP-IDA provides a platform for common data models and Application Programming Interfaces to access, integrate, process, and display CHP data (e.g., environmental, exercise, medical, sleep, performance, etc.). This will facilitate the increased situation awareness and decision support required by the crew and remote support of exploration missions. This presentation will describe the currently ongoing effort to develop and evaluate a path-to-flight concept of the CHP-IDA software and its core capabilities. Current integrations will be discussed, including analytics for Extravehicular Activity metabolic rate and data ingestion from a multi-functional integrated medical device. The presentation will also provide examples of scenarios used to demonstrate the CHP-IDA through human-in-the-loop test bed activities as well as examples of appropriate system performance metrics. DISCUSSION: Today, in-flight data is often siloed, unsynchronized, and largely inaccessible in real time. Many data sets require manual entry and/or data transfer between vehicles and the ground. These issues contribute to risks in supporting exploration medical capabilities. The CHP-IDA is a back-end data system providing core capabilities needed for timely and meaningful data insights across CHP domains to crew and remote personnel to enable increased crew autonomy. Future work includes collaboration with additional CHP domains, new technology integrations, and further demonstrations of the IDA within different vehicle and communication latency contexts. LEARNING OBJECTIVES 1. The audience will understand that the CHP-IDA is a back-end system, providing a platform to facilitate access, promote decision tools, and provide meaningful insights to crew and to remote stakeholders during exploration missions. 2. The audience will gain insight into human-centered research and activities used to discover CHP domain data needs and pain points and how this information is used to guide development of the IDA.

Exploration↗

OC7 Phase I Definition Document

The Offshore Code Comparison Collaboration 7 (OC7) project is organized under the International Energy Agency Wind Technology Collaboration Programme Task 56 with an objective to evaluate and enhance the predictive accuracy of engineering-level modeling tools used in the design of offshore wind energy systems. Phase I of OC7 is focused on improving the models and modeling practices of hydrodynamic viscous loads on floating offshore wind turbine platforms. In alignment with this goal, Work Package 1.1 of OC7 Phase I is formulated to investigate the modeling of hydrodynamic viscous loads on several different geometric components commonly encountered with floating offshore wind platform designs, including cylindrical columns, heave plates, and rectangular pontoons. Work Package 1.1 also explores the dependence of hydrodynamic coefficients on the sea state to drive toward practical guidance on how these coefficients can be selected or adjusted for different conditions. This report outlines the motivation and objectives behind each subphase of OC7 Phase I, along with the necessary technical specifications and load case definitions to guide the project participants. It also serves as an important part of the project documentation for future modelers who would like to reproduce this work or make use of the data and information generated from the OC7 project.

17 WIND ENERGY↗

Controlling Host Responses to Infection

Pathogen invasion of host cells causes a myriad of functional changes including alterations of chromatin accessibility often limiting defense responses, shunting of cellular resources to centers of viral replication, and rearrangement of intracellular membranes to facilitate genome reproduction and progeny release. Systems biology approaches provide global snapshots of pathogen induced changes following infection and provide a variety of tools to begin to define how cellular homeostasis is disrupted, but improvements on these tools are required to determine how cellular functions are altered post infection. Chromatin accessibility techniques, biochemical assays to assess the activity of epigenetic enzymes, scalable sample collection platforms, and activity-based probes were used to characterize how human respiratory viruses modify host responses in infected human lungs over time. These studies enhanced our knowledge of how pathogens usurp the host environment during infection and identify additional targets for future evaluations of medical countermeasures.

59 BASIC BIOLOGICAL SCIENCES↗

SATS Enhanced Capabilities and Demonstration of Improved Ramp Rates for In-Cell Testing

This report presents the development of the second-generation Severe Accident Test Station, referred to as SATS 2.0. SATS 2.0 represents a major advancement in addressing critical research needs for the United States nuclear industry, particularly in relation to fuel fragmentation, relocation, and dispersal (FFRD) concerns associated with the nuclear industry’s goal to extend fuel burnup beyond a peak rod average of 62 GWd/tU. The central objective of SATS 2.0 was the deployment a new furnace capable of achieving heating rates up to 100°C/s. This achievement addresses critical capability gaps, enabling assessment of prioritized research objectives established by the Electric Power Research Institute’s (EPRI) Collaborative Research on Advanced Fuel Technologies (CRAFT) working group. These research objectives are directly related to high-burnup loss-of-coolant accident (LOCA) conditions and the effects of prolonged exposure to elevated temperatures, both of which are crucial to enhancing nuclear safety and efficiency. The SATS 2.0 system builds upon prior experience with the original SATS system, which focused on evaluating accident-tolerant fuel (ATF) cladding concepts during accident conditions. However, the new system not only expands upon prior core capabilities by achieving higher heating rates with a better furnace but also plans to incorporate novel auxiliary systems to create a versatile platform for addressing current research needs. For example, a system was developed for the quantification and characterization of fission gas released during high-temperature transients. Additionally, in situ measurement capabilities were developed, such as digital image correlation which enabled the real-time capture of strain related to balloon and burst events and fiber-optic sensors that allowed for high-fidelity characterization of temperature gradients. Demonstration tests of the new 12-lamp furnace achieved heating rates up to 120°C/s. Notably, SATS 2.0 demonstrated its capacity to simulate LOCA burst tests at different pressures, yielding burst data that align with historical empirical models. Moreover, the system exhibited its capability to simulate complex conditions observed in anticipated operational occurrences, while effectively mitigating temperature overshoots. These accomplishments mark significant progress toward overcoming FFRD challenges and advancing the United States nuclear industry's safety basis and technical capabilities for extended burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote sensing of Earth's atmosphere and surface using a digital array scanned interferometer: A new type of imaging spectrometer

The capabilities of the digital array scanned interferometer (DASI) class of instruments for measuring terrestrial radiation fields over the visible to mid-infrared are evaluated. DASI's are capable of high throughput, sensitivity and spectral resolution and have the potential for field-of-view spatial discrimination (an imaging spectrometer). The simplicity of design and operation of DASI's make them particularly suitable for field and airborne platform based remote sensing. The long term objective is to produce a versatile field instrument which may be applied toward a variety of atmospheric and surface studies. The operation of DASI and its advantages over other spectrometers are discussed.

Hammer, Philip D.↗

On the use of Space Station Freedom in support of the SEI - Life science research

The use of the Space Station Freedom (SSF) for life sciences research is evaluated from the standpoint of requirements for the Space Exploration Initiative (SEI). SEI life sciences research encompasses: (1) biological growth and development in space; (2) life support and environmental health; (3) physiological/psychological factors of extended space travel; and (4) space environmental factors. The platforms required to support useful study in these areas are listed and include ground-based facilities, permanently manned spacecraft, and the Space Shuttle. The SSF is shown to be particularly applicable to the areas of research because its facilities can permit the study of gravitational biology, life-support systems, and crew health. The SSF can serve as an experimental vehicle to derive the required knowledge needed to establish a commitment to manned Mars missions and colonization plans.

Leath, K.↗

An Initial Examination of Roll-Lateral Coordination Motion Requirements in Flight Simulation

A piloted simulation that examined the effects of uncoordinated roll-lateral motion cues from a coordinated math model was conducted. The vehicle model represented a typical helicopter with satisfactory handling qualities in the roll-lateral axes. The task was a two-degree-of-freedom horizontal sidestep, where the pilot controlled lateral position through roll angle. The motion platform commands were varied via two motion control system gains. One gain reduced the ratio between platform roll angle to math model (and thus visual) roll angle. The other gain was placed on how much lateral platform movement would result from platform roll attitude in an attempt to align the apparent gravity vector vertically relative to the pilot. Gains from one to zero were examined in both axes. Thus, the true 1:1 motion case, where the motion cues matched the visual cues was evaluated. Pilots subjective ratings of motion fidelity matched well against an earlier developed motion fidelity criteria. Significant differences were noted in the fixed-base versus motion base configurations.

Schroeder, Jeffery A.↗

Comparison of Cloud Resolving Model Simulations to Remote Sensing Data

The purpose of this research was to evaluate the ability of a cloud-resolving model (CRM) to simulate the dynamical, radiative, and microphysical properties of deep convective cloud objects identified using CERES (Clouds and the Earth s Radiant Energy System) on board the Tropical Rainfall Measuring Mission (TRMM) satellite platform, for many cases. A deep convective cloud object is a contiguous region that is composed of satellite footprints that fulfill the following selection criteria: 100% cloud fraction, cloud optical depth > 10, and a cloud top height of at least 10 km. Selection criteria have also been formed for different types of boundary-layer clouds, as described in Xu et al. (2005). The purpose of the cloud object approach is to identify specific areas of where the cloud properties simulated by the CRM systematically differ from the observed cloud properties. Where these systematic differences exist, concrete steps can be made to improve the CRM s simulation of an entire class of clouds, rather than by tuning the model to correctly simulate a single case study, as is often done. Additional information regarding detailed approaches and findings are presented.

Randall, David A.↗

Simulation of the Impact of New Aircraft- and Satellite-Based Ocean Surface Wind Measurements on H*Wind Analyses and Numerical Forecasts

The Hurricane Imaging Radiometer (HIRAD) is a new airborne microwave remote sensor for hurricane observations that is currently under development by NASA Marshall Space Flight Center, NOAA Hurricane Research Division, the University of Central Florida and the University of Michigan. HIRAD is being designed to enhance the realtime airborne ocean surface winds observation capabilities of NOAA and USAF Weather Squadron hurricane hunter aircraft using the operational airborne Stepped Frequency Microwave Radiometer (SFMR). Unlike SFMR, which measures wind speed and rain rate along the ground track directly beneath the aircraft, HIRAD will provide images of the surface wind and rain field over a wide swath (~ 3 x the aircraft altitude). The present paper describes a set of Observing System Simulation Experiments (OSSEs) in which measurements from the new instrument as well as those from existing instruments (air, surface, and space-based) are simulated from the output of a detailed numerical model, and those results are used to construct H*Wind analyses. The H*Wind analysis, a product of the Hurricane Research Division of NOAA s Atlantic Oceanographic and Meteorological Laboratory, brings together wind measurements from a variety of observation platforms into an objective analysis of the distribution of wind speeds in a tropical cyclone. This product is designed to improve understanding of the extent and strength of the wind field, and to improve the assessment of hurricane intensity. See http://www.aoml.noaa.gov/hrd/data_sub/wind.html. Evaluations will be presented on the impact of the HIRAD instrument on H*Wind analyses, both in terms of adding it to the full suite of current measurements, as well as using it to replace instrument(s) that may not be functioning at the future time the HIRAD instrument is deployed. Plans to demonstrate the potential for HIRAD to improve numerical weather prediction of hurricanes will also be presented.

Miller, Timothy↗

Simulation of the Impact of New Aircraft- and Satellite-Based Ocean Surface Wind Measurements on H*Wind Analyses and Numerical Forecasts

The Hurricane Imaging Radiometer (HIRAD) is a new airborne microwave remote sensor for hurricane observations that is currently under development by NASA Marshall Space Flight Center, NOAA Hurricane Research Division, the University of Central Florida and the University of Michigan. HIRAD is being designed to enhance the realtime airborne ocean surface winds observation capabilities of NOAA and USAF Weather Squadron hurricane hunter aircraft using the operational airborne Stepped Frequency Microwave Radiometer (SFMR). Unlike SFMR, which measures wind speed and rain rate along the ground track directly beneath the aircraft, HIRAD will provide images of the surface wind and rain field over a wide swath (~ 3 x the aircraft altitude). The present paper describes a set of Observing System Simulation Experiments (OSSEs) in which measurements from the new instrument as well as those from existing instruments (air, surface, and space-based) are simulated from the output of a detailed numerical model, and those results are used to construct H*Wind analyses. The H*Wind analysis, a product of the Hurricane Research Division of NOAA s Atlantic Oceanographic and Meteorological Laboratory, brings together wind measurements from a variety of observation platforms into an objective analysis of the distribution of wind speeds in a tropical cyclone. This product is designed to improve understanding of the extent and strength of the wind field, and to improve the assessment of hurricane intensity. See http://www.aoml.noaa.gov/hrd/data_sub/wind.html. Evaluations will be presented on the impact of the HIRAD instrument on H*Wind analyses, both in terms of adding it to the full suite of current measurements, as well as using it to replace instrument(s) that may not be functioning at the future time the HIRAD instrument is implemented. Also shown will be preliminary results of numerical weather prediction OSSEs in which the impact of the addition of HIRAD observations to the initial state on numerical forecasts of the hurricane intensity and structure is assessed.

Miller, Timothy↗

Hardware Demonstration: Frequency Spectra of Transients

Radiated emissions measurements as specified by MIL-STD-461 are performed in the frequency domain, which is best suited to continuous wave (CW) types of signals. However, many platforms implement signals that are single event pulses or transients. Such signals can potentially generate momentary radiated emissions that can cause interference in the system, but they may be missed with traditional measurement techniques. This demonstration provides measurement and analysis techniques that effectively evaluate the potential emissions from such signals in order to evaluate their potential impacts to system performance.

EMI↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Design of the HELICS High-Performance Transmission-Distribution-Communication-Market Co-Simulation Framework

This paper describes the design rationale for a new cyber-physical-energy co-simulation framework for electric power systems. This new framework will support very large-scale (100,000+ federates) co-simulations with off-the-shelf power-systems, communication, and end-use models. Other key features include cross-platform operating system support, integration of both event-driven (e.g. packetized communication) and time-series (e.g. power flow) simulation, and the ability to co-iterate among federates to ensure model convergence at each time step. After describing requirements, we begin by evaluating existing co-simulation frameworks, including HLA and FMI, and conclude that none provide the required features. Then we describe the design for the new layered co-simulation architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging

This symposium highlights advanced cone-beam CT (CBCT) technologies in four areas of emerging application in diagnostic imaging and image-guided interventions. Each area includes research that extends the spatial, temporal, and/or contrast resolution characteristics of CBCT beyond conventional limits through advances in scanner technology, acquisition protocols, and 3D image reconstruction techniques. Dr. G. Chen (University of Wisconsin) will present on the topic: Advances in C-arm CBCT for Brain Perfusion Imaging. Stroke is a leading cause of death and disability, and a fraction of people having an acute ischemic stroke are suitable candidates for endovascular therapy. Critical factors that affect both the likelihood of successful revascularization and good clinical outcome are: 1) the time between stroke onset and revascularization; and 2) the ability to distinguish patients who have a small volume of irreversibly injured brain (ischemic core) and a large volume of ischemic but salvageable brain (penumbra) from patients with a large ischemic core and little or no penumbra. Therefore, “time is brain” in the care of the stroke patients. C-arm CBCT systems widely available in angiography suites have the potential to generate non-contrast-enhanced CBCT images to exclude the presence of hemorrhage, time-resolved CBCT angiography to evaluate the site of occlusion and collaterals, and CBCT perfusion parametric images to assess the extent of the ischemic core and penumbra, thereby fulfilling the imaging requirements of a “one-stop-shop” in the angiography suite to reduce the time between onset and revascularization therapy. The challenges and opportunities to advance CBCT technology to fully enable the one-stop-shop C-arm CBCT platform for brain imaging will be discussed. Dr. R. Fahrig (Stanford University) will present on the topic: Advances in C-arm CBCT for Cardiac Interventions. With the goal of providing functional information during cardiac interventions, significant effort has been expended to improve the quantitative accuracy of C-arm CBCT reconstructions. The challenge is to improve image quality while providing very short turnaround between data acquisition and volume data visualization. Corrections for x-ray scatter, view aliasing and patient motion that require no more than 2 iterations keep processing time short while reducing artifact. Fast, multi-sweep acquisitions can be used to permit assessment of left ventricular function, and visualization of radiofrequency lesions created to treat arrhythmias. Workflows for each imaging goal have been developed and validated against gold standard clinical CT or histology. The challenges, opportunities, and limitations of the new functional C-arm CBCT imaging techniques will be discussed. Dr. W. Zbijewski (Johns Hopkins University) will present on the topic: Advances in CBCT for Orthopaedics and Bone Health Imaging. Cone-beam CT is particularly well suited for imaging of musculoskeletal extremities. Owing to the high spatial resolution of flat-panel detectors, CBCT can surpass conventional CT in imaging tasks involving bone visualization, quantitative analysis of subchondral trabecular structure, and visualization and monitoring of subtle fractures that are common in orthopedic radiology. A dedicated CBCT platform has been developed that offers flexibility in system design and provides not only a compact configuration with improved logistics for extremities imaging but also enables novel diagnostic capabilities such as imaging of weight-bearing lower extremities in a natural stance. The design, development and clinical performance of dedicated extremities CBCT systems will be presented. Advanced capabilities for quantitative volumetric assessment of joint space morphology, dual-energy image-based quantification of bone composition, and in-vivo analysis of bone microarchitecture will be discussed, along with emerging applications in the diagnosis of arthritis and osteoporosis and assessment of novel therapies. Finally, Dr. J. Boone (UC Davis) will present on the topic: Advances in CBCT for Breast Imaging. Breast CT has been studied as an imaging tool for diagnostic breast evaluation and for potential breast cancer screening. The breast CT application lends itself to CBCT because of the small dimensions of the breast, the tapered shape of the breast towards higher cone angle, and the fact that there are no bones in the breast. The performance of various generations of breast CT scanners developed in recent years will be discussed, focusing on advances in spatial resolution and image noise characteristics. The results will also demonstrate the results of clinical trials using both computer and human observers. Learning Objectives: Understand the challenges, key technological advances, and emerging opportunities of CBCT in: Brain perfusion imaging, including assessment of ischemic stroke Cardiac imaging for functional assessment in cardiac interventions Orthopedics imaging for evaluation of musculoskeletal trauma, arthritis, and osteoporosis Breast imaging for screening and diagnosis of breast cancer. Work presented in this symposium includes research support by: Siemens Healthcare (Dr. Chen); NIH and Siemens Healthcare (Dr. Fahrig); NIH and Carestream Health (Dr. Zbijewski); and NIH (Dr. Boone)

60 APPLIED LIFE SCIENCES↗