Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “enhanced sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Serum Amyloid A as a Predictive Marker for Radiation Pneumonitis in Lung Cancer Patients

Purpose: To investigate serum markers associated with radiation pneumonitis (RP) grade ≥3 in patients with lung cancer who were treated with radiation therapy. Methods and Materials: Pretreatment serum samples from patients with stage Ib-IV lung cancer who developed RP within 1 year after radiation therapy were analyzed to identify a proteome marker able to stratify patients prone to develop severe RP by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). Dosimetric parameters and 3 biological factors were compared. Results: Serum samples from 16 patients (28%) with severe RP (grade 3-4) and 42 patients (72%) with no or mild RP (grade 0-2) were collected for analysis. All patients received a median of 54 Gy (range, 42-70 Gy) of three-dimensional conformal radiation therapy with a mean lung dose (MLD) of 1502 cGy (range, 700-2794 cGy). An m/z peak of 11,480 Da was identified by SELDI-TOF-MS, and serum amyloid A (SAA) was the primary splitter serum marker. The receiver operating characteristic area under the curve of SAA (0.94; 95% confidence interval [CI], 0.87-1.00) was higher than those of C-reactive protein (0.83; 95% CI, 0.72-0.94), interleukin-6 (0.79; 95% CI, 0.65-0.94), and MLD (0.57; 95% CI, 0.37-0.77). The best sensitivity and specificity of combined SAA and MLD for predicting RP were 88.9% and 96.0%, respectively. Conclusions: Baseline SAA could be used as an auxiliary marker for predicting severe RP. Extreme care should be taken to limit the lung irradiation dose in patients with high SAA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-EF-BRA-08: A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation

Purpose: To develop a technique to estimate on-board VC-MRI using multi-slice sparsely-sampled cine images, patient prior 4D-MRI, motion-modeling and free-form deformation for real-time 3D target verification of lung radiotherapy. Methods: A previous method has been developed to generate on-board VC-MRI by deforming prior MRI images based on a motion model(MM) extracted from prior 4D-MRI and a single-slice on-board 2D-cine image. In this study, free-form deformation(FD) was introduced to correct for errors in the MM when large anatomical changes exist. Multiple-slice sparsely-sampled on-board 2D-cine images located within the target are used to improve both the estimation accuracy and temporal resolution of VC-MRI. The on-board 2D-cine MRIs are acquired at 20–30frames/s by sampling only 10% of the k-space on Cartesian grid, with 85% of that taken at the central k-space. The method was evaluated using XCAT(computerized patient model) simulation of lung cancer patients with various anatomical and respirational changes from prior 4D-MRI to onboard volume. The accuracy was evaluated using Volume-Percent-Difference(VPD) and Center-of-Mass-Shift(COMS) of the estimated tumor volume. Effects of region-of-interest(ROI) selection, 2D-cine slice orientation, slice number and slice location on the estimation accuracy were evaluated. Results: VCMRI estimated using 10 sparsely-sampled sagittal 2D-cine MRIs achieved VPD/COMS of 9.07±3.54%/0.45±0.53mm among all scenarios based on estimation with ROI-MM-ROI-FD. The FD optimization improved estimation significantly for scenarios with anatomical changes. Using ROI-FD achieved better estimation than global-FD. Changing the multi-slice orientation to axial, coronal, and axial/sagittal orthogonal reduced the accuracy of VCMRI to VPD/COMS of 19.47±15.74%/1.57±2.54mm, 20.70±9.97%/2.34±0.92mm, and 16.02±13.79%/0.60±0.82mm, respectively. Reducing the number of cines to 8 enhanced temporal resolution of VC-MRI by 25% while maintaining the estimation accuracy. Estimation using slices sampled uniformly through the tumor achieved better accuracy than slices sampled non-uniformly. Conclusions: Preliminary studies showed that it is feasible to generate VC-MRI from multi-slice sparsely-sampled 2D-cine images for real-time 3D-target verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Effects on crystal structure of CZTS thin films owing to deionized water and sulfurization treatment

To condense the cost and increase the production, using abundantly obtainable non-toxic elements, Cu{sub 2}ZnSnS{sub 4} (CZTS) seem to be a strong contender among the photovoltaic thin film technologies. Cu{sub 2}ZnSnS{sub 4} thin films were fabricated by RF magnetron sputtering system. CZTS were sputtered on Molybdenum (Mo) coated soda lime glass (SLG) using a single target sputtering technique. The sputtering parameters (base pressure, working pressure, Argon (Ar) flow rate, RF power and sputtering time) were kept same for all three types of films. For sulfurization, the temperature used was 500 °C. Finally, As-deposited film was immersed in DIW before undergoing identical sulfurization profile. As-deposited film (Sample A), sulfurized films (Sample B) and sulfurized plus DIW treated (Sample C) were compared in terms of their structural properties by means of X-Ray Diffraction (XRD) measurement and Atomic Force Microscopy (AFM). Sample B and C showed peak of (1 1 2) planes of CZTS which are characteristics of stannite structure. Post deposition treatment on CZTS films proved to be beneficial as evident from the observed enhancement in the crystallinity and grain growth. Significant difference on grain size and area roughness could be observed from the AFM measurement. The roughness of Sample A, B and C increased from 5.007 nm to 20.509 nm and 14.183 nm accordingly. From XRD data secondary phases of Cu{sub x}MoS{sub x} could be observed.

36 MATERIALS SCIENCE↗

Shockwave-Loading-Induced Enhancement of T c in Superconducting Bi 2 Sr 2 CaCu 2 O 8+δ

Here, we report a shockwave method for altering the properties of the superconductor material Bi 2 Sr 2 CaCu 2 O 8+δ (Bi2212). We find that the superconducting transition temperature (T c ) increases from 84 K for the pristine sample to 94 K for the sample treated at a temperature and pressure of ~1200 K and ~31 GPa, respectively. X-ray diffraction and transmission electron microscopy characterizations indicate that this T c enhancement arises from a phase transition from pristine Bi2212 to a mixture of superconducting Bi2212 and semiconducting Bi 2 Sr 2 CuO 6+δ (Bi2201) during the shockwave treatment. The shockwave-treated sample exhibits n-type semiconductor properties (with an on-off ratio ~5), in contrast to the pure metallic pristine sample. This study offers an alternative route for modifying the superconducting properties via a shockwave treatment. Furthermore, this method may provide a new approach for studying other temperature- and pressure-sensitive materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electronic and magnetic properties of Si substituted Fe{sub 3}Ge

Using first principles calculations, we studied the effect of Si substitution in the hexagonal Fe{sub 3}Ge. We find the low temperature magnetic anisotropy in this system to be planar and originating mostly from the spin-orbit coupling in Fe-d states. Reduction of the unitcell volume reduces the magnitude of in-plane magnetic anisotropy, eventually turning it positive which reorients the magnetic moments to the axial direction. Substituting Ge with the smaller Si ions also increases the anisotropy, potentially enhancing the region of stability of the axial magnetization, which is beneficial for magnetic applications such as permanent magnets. Our experimental measurements on samples of Fe{sub 3}Ge{sub 1−x}Si{sub x} confirm these predictions and show that substitution of about 6% of the Ge with Si increases by approximately 35 K the temperature range over which anisotropy is uniaxial.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rapid Determination Of Radiostrontium In Large Soil Samples

A new method for the determination of radiostrontium in large soil samples has been developed at the Savannah River Environmental Laboratory (Aiken, SC, USA) that allows rapid preconcentration and separation of strontium in large soil samples for the measurement of strontium isotopes by gas flow proportional counting. The need for rapid analyses in the event of a Radiological Dispersive Device (RDD) or Improvised Nuclear Device (IND) event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. The method employs a novel pre-concentration step that utilizes an iron hydroxide precipitation (enhanced with calcium phosphate) followed by a final calcium fluoride precipitation to remove silicates and other matrix components. The pre-concentration steps, in combination with a rapid Sr Resin separation using vacuum box technology, allow very large soil samples to be analyzed for {sup 89,90}Sr using gas flow proportional counting with a lower method detection limit. The calcium fluoride precipitation eliminates column flow problems typically associated with large amounts of silicates in large soil samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Geolab in NASA's First Generation Pressurized Excursion Module: Operational Concepts

We are building a prototype laboratory for preliminary examination of geological samples to be integrated into a first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM) in 2010. The laboratory GeoLab will be equipped with a glovebox for handling samples, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM will be tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASAs annual field exercise designed to test analog mission technologies. The HDU1-PEM and GeoLab will participate in joint operations in northern Arizona with two Lunar Electric Rovers (LER) and the DRATS science team. Historically, science participation in DRATS exercises has supported the technology demonstrations with geological traverse activities that are consistent with preliminary concepts for lunar surface science Extravehicular Activities (EVAs). Next years HDU1-PEM demonstration is a starting point to guide the development of requirements for the Lunar Surface Systems Program and test initial operational concepts for an early lunar excursion habitat that would follow geological traverses along with the LER. For the GeoLab, these objectives are specifically applied to enable future geological surface science activities. The goal of our GeoLab is to enhance geological science returns with the infrastructure that supports preliminary examination, early analytical characterization of key samples, insight into special considerations for curation, and data for prioritization of lunar samples for return to Earth.

Evans, C. A.↗

Evaluating Photocatalysts Using Gamma Radiation

A large amount of attention has been given to photocatalysts using UV radiation as the source of excitation; however, little work has been done to study photocatalysis using higher energy excitation sources, such as gamma or x-rays. During excitation, the photocatalyst absorbs light to produce electron-hole pairs (excitons). These excitons can react with absorbed species to yield reactive radical species that can degrade compounds or induce redox (oxidation-reduction) reactions. Common examples of semiconductor photocatalysts include: TiO{sub 2}, ZnO, Fe{sub 2}O{sub 3}, ZrO{sub 2}, and SnS. This project was conducted to investigate the photocatalytic oxidation of iron using gamma irradiation and several different semiconductor photocatalysts. Photometric Measurements: Photometric determination of Fe{sup II} and Fe{sup III} were made using a Cary 60 UV-Vis Spectrometer over a range of 800 - 200 nm at a scan rate of 60 nm/sec. Ferric (Fe{sup III}) ions have no detectable UV-vis spectrum, thus the absence of a peak in iron-based samples was taken as evidence of Fe{sup III} formation. Solution Preparation: Iron II (Fe{sup II}) standards were made by dissolving FeCl{sub 2}.6H{sub 2}O in deionized water using a sonicator. A solution of 1,10- phenanthroline was made by adding 40 mg of 1,10-phenanthroline to 20 mL of deionized water and sonicating for 60 minutes until a clear solution was obtained. Gamma Radiation Tests: Irradiated samples were exposed to Co-60 gamma radiation (1.17 MeV gamma) at a dose rate of ∼1 x 10{sup 5} Rad/hr Co-60. All samples were irradiated in glass scintillation vials. The presence of 30 mg of SnS reduces the amount of Fe{sup II} in solutions under gamma irradiation relative to samples with no SnS added. Fe{sup II} concentration decreases as irradiation time increases. This effect is enhanced when SnS is present. Fe{sup II} appears to decrease linearly with time. We found that the addition of SnS semiconductor, when combined with gamma radiation, oxidized more Fe{sup II} in the FeCl{sub 2} solution than gamma radiation alone. This suggests that SnS can be used as a photocatalyst using gamma radiation as the excitation source, although more detailed experiments are needed to confirm this belief. The next phase of this project would be to refine the preliminary results by determining exact quantities of SnS semiconductor and gamma radiation that induce sufficient redox. Repeated experiments with more samples could also give more data points for a chance at more representative and accurate data with error bars and standard deviations. Also, other semiconductors could possibly be tested to see how their effect on redox chemistry compares to that of SnS. The scope of this project could also be extended to include other metal or organic solutions to see if similar redox could be obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Injection‐Induced Shear Slip and Permeability Enhancement in Granite Fractures

Abstract Shear stimulation, so‐called hydroshearing , is believed to reactivate critical or near‐critical preexisting fractures by pressurized fluid injection, causing them to slip and dilate for economic production from geothermal and unconventional petroleum reservoirs. However, little or no experiments have been conducted to directly probe the coupled hydromechanical responses and permeability evolution during fracture shearing. In this paper, we present the results of novel injection‐induced shear tests on cylindrical granite samples each containing a single tensile or saw cut fracture. The shear test on rough fractures demonstrates that retainable permeability enhancement can be achieved through dilatant shear slip. The characteristic stick‐slip behavior of the fracture during shearing is also observed. Fracture aperture controlled by effective normal stress dominates the fluid flow in stick state, while in slip state, the major contributor to production increase is the irreversible normal dilation caused by fracture shear slip. The experimental data show that depending on the fracture roughness, the fracture slip process includes two quasi‐static slip intervals with a slip velocity of ~10 −9 to ~10 −6 m/s and a dynamic slip interval with a slip velocity of ~10 −7 to ~10 −5 m/s. The fracture slip correlates well with the associated stress relaxation: a faster fracture slip induces a quicker stress relaxation, and vice versa. The influence of surface roughness on the hydromechanical responses during fracture shearing and the shear‐induced asperity degradation are also studied. The various experimental observations on rough and smooth fractures clearly indicate that the key component to shear stimulation is fracture self‐propping by asperities.

Ye, Zhi↗

Mesoporous SiO{sub 2} produced by mineralization of yeast cells as an efficient electrocatalyst for oxygen reduction reaction

Mes oporous SiO{sub 2} (yeast-SiO{sub 2}/C) was successfully prepared by mineralization of yeast cell template under different pH values. Analysis of the nitrogen adsorption-desorption isotherms indicated that the pore size distribution of the mesoporous yeast-SiO{sub 2} samples significantly varies depending on the pH value used f or biomineralization. Average pore diameters for the samples synthesized at pH 5.0, 7.0, and 11.0 were found to be 7.9, 17.8, and 9.4 nm, respectively. The mineralization ability of silicon ions can be enhanced using conditions with a higher acidity. The air electrodes fabricated using the yeast-SiO{sub 2} mesoporous composites exhibited remarkable electrocatalytic activity in oxygen reduction reaction under alkaline conditions. The mesoporous sample synthesized at pH 5.0 showed the highest electrocatalytic performance in the oxygen reduction reaction; this sample has the largest surface area and the highest total pore volume. It is supposed that the mesoporous structure of the nanocomposites predetermined by the yeast cell template significantly reduced the electrochemical polarization and improved mass transport in the air diffusion electrode.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tip- and Plasmon-Enhanced Infrared Nanoscopy for Ultrasensitive Molecular Characterizations

Herein, we propose a method for ultrasensitive infrared (IR) vibrational spectroscopy of molecules with nanoscale footprints by combining the tip enhancement of a scattering-type scanning near-field optical microscope (s-SNOM) and the plasmon enhancement of breathing-mode (BM) plasmon resonances of graphene nanodisks (GNDs). To demonstrate this, we develop a quantitative model that is capable of computing accurately the s-SNOM signals of nanoscale samples. With our modeling, we show that the s-SNOM tip can effectively excite gate-tunable BM plasmonic resonances in GNDs with strong field enhancement and sensitive dependence on the size of GND. Moreover, we demonstrate that the intense electric field of tip-excited plasmonic BMs can strongly enhance the IR vibrational modes of molecules. As a result, IR vibrational signatures of individual molecular particles with sizes down to 1–2 nm are readily observable by s-SNOM. Our study sheds light on future ultrasensitive IR biosensing that takes advantage of both the tip and plasmon enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon Coating Influence on the Formation of Percolating Electrode Networks for Silicon Anodes

Previous studies have demonstrated that chemical vapor deposition carbon coating on silicon (Si@C) can enhance the electrochemical performance of lithium-ion batteries with Si-based anodes. However, the underlying mechanisms contributing to this improvement have not been fully explored. Here, we address this knowledge gap by applying a suite of characterization methods to evaluate Si@C anodes prepared by reducing acetylene on ball-milled Si particles. Raman mapping measurements show that the C coating (<5 nm thick) enables a homogeneous Si and carbon distribution during the slurry casting process, thereby promoting Si utilization during cycling. The coating’s microstructure and morphology were evaluated using X-ray photoelectron spectroscopy (XPS), scanning transmission electron microscopy, and neutron reflectivity experiments. Electrochemical impedance spectroscopy measurements upon cycling indicate that carbon coating also reduces the overall resistance as benchmarked against bare Si anodes. Galvanostatic cycling in half-cell studies revealed higher initial Coulombic efficiency and specific capacities with increasing carbon coating time. However, solid electrolyte interphase (SEI) investigations using XPS showed that the coated and uncoated samples have very similar characteristics, suggesting that the SEI may only play a minor role in enhancing the performance of Si@C. Full-cell evaluation of the Si electrodes was consistent with half-cell results relating to performance and SEI properties, further supporting the conclusion that electronic and ionic percolation, enabled by effective electrode manufacturing, are the dominant factors contributing to the favorable performance of Si@C.

25 ENERGY STORAGE↗

Quantifying Transport, Geometrical, and Morphological Parameters in Li-Ion Cathode Phases Using X-ray Microtomography

The charge/discharge capabilities of Li-ion cathodes are influenced by the meso-scale geometry, transport properties, and morphological parameters of the constituent phases in the cathode: active material, binder, conductive additive, and pore. Electrode processing influences the structure and attendant properties of these constituents. Thus, performance of the battery can be enhanced by correlating various electrode processing techniques with the charge/discharge behavior in the lithium-ion cathodes. X-ray microtomography was used to image samples obtained from pristine Li(Ni 1/3 Mn 1/3 Co 1/3 )O 2 (NMC) cathodes subjected to distinct processing approaches. Two sample preparation approaches were applied to the samples prior to microtomography. Casting the samples in epoxy yielded only the cathode active material domain. Encapsulating the sample with Kapton tape yielded phase contrast data that permitted segmentation of the active material and combined carbon/binder and pore regions. Here, geometrical and morphological details of the active material and the secondary phases were characterized and compared between the varied processing approaches. Calendered and ball-milled samples exhibited distinct differences in both geometry and morphology. Drying modes demonstrated variation in the distribution of the secondary and pore phases. Applying phase contrast capabilities, the processing–morphology relationship can be better understood to enhance overall battery performance across multiple scales.

36 MATERIALS SCIENCE↗

The SDSS-IV MaNGA Sample: Design, Optimization, and Usage Considerations

We describe the sample design for the SDSS-IV MaNGA survey and present the final properties of the main samples along with important considerations for using these samples for science. Our target selection criteria were developed while simultaneously optimizing the size distribution of the MaNGA integral field units (IFUs), the IFU allocation strategy, and the target density to produce a survey defined in terms of maximizing signal-to-noise ratio, spatial resolution, and sample size. Our selection strategy makes use of redshift limits that only depend on i-band absolute magnitude (M {sub i}), or, for a small subset of our sample, M {sub i} and color (NUV − i). Such a strategy ensures that all galaxies span the same range in angular size irrespective of luminosity and are therefore covered evenly by the adopted range of IFU sizes. We define three samples: the Primary and Secondary samples are selected to have a flat number density with respect to M {sub i} and are targeted to have spectroscopic coverage to 1.5 and 2.5 effective radii (R {sub e}), respectively. The Color-Enhanced supplement increases the number of galaxies in the low-density regions of color–magnitude space by extending the redshift limits of the Primary sample in the appropriate color bins. The samples cover the stellar mass range 5×10{sup 8}⩽M{sub ∗}⩽3×10{sup 11} M{sub ⊙} h{sup −2} and are sampled at median physical resolutions of 1.37 and 2.5 kpc for the Primary and Secondary samples, respectively. We provide weights that will statistically correct for our luminosity and color-dependent selection function and IFU allocation strategy, thus correcting the observed sample to a volume-limited sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Abundances in the Local Region. III. Southern F, G, and K Dwarfs

Stellar parameters and abundances have been derived from a sample of 907 F, G, and K dwarfs. The high-resolution, high signal-to-noise spectra utilized were acquired with the HARPS spectrograph of the European Southern Observatory. The stars in the sample with −0.2 < [Fe/H] < +0.2 have abundances that strongly resemble that of the Sun, except for the lithium content and the lanthanides. Near the solar temperature, stars show two orders of magnitude range in lithium content. The average content of stars in the local region appears to be enhanced at about the +0.1 level relative to the Sun for the lanthanides. There are over 100 planet hosts in this sample, and there is no discernible difference between them and the non-hosts regarding their lithium content.

79 ASTRONOMY AND ASTROPHYSICS↗

A suite of benchmark and challenge problems for enhanced geothermal systems

A diverse suite of numerical simulators is currently being applied to predict or understand the performance of enhanced geothermal systems (EGS). To build confidence and identify critical development needs for these analytical tools, the United States Department of Energy, Geothermal Technologies Office sponsored a Code Comparison Study (GTO-CCS), with participants from universities, industry, and national laboratories. A principal objective for the study was to create a community forum for improvement and verification of numerical simulators for EGS modeling. Teams participating in the study were those representing U.S. national laboratories, universities, and industries, and each team brought unique numerical simulation capabilities to bear on the problems. Two classes of problems were developed during the study, benchmark problems and challenge problems. The benchmark problems were structured to test the ability of the collection of numerical simulators to solve various combinations of coupled thermal, hydrologic, geomechanical, and geochemical processes. This class of problems was strictly defined in terms of properties, driving forces, initial conditions, and boundary conditions. The challenge problems were based on the enhanced geothermal systems research conducted at Fenton Hill, near Los Alamos, New Mexico, between 1974 and 1995. The problems involved two phases of research, stimulation, development, and circulation in two separate reservoirs. The challenge problems had specific questions to be answered via numerical simulation in three topical areas: (1) reservoir creation/stimulation, (2) reactive and passive transport, and (3) thermal recovery. Whereas the benchmark class of problems were designed to test capabilities for modeling coupled processes under strictly specified conditions, the stated objective for the challenge class of problems was to demonstrate what new understanding of the Fenton Hill experiments could be realized via the application of modern numerical simulation tools by recognized expert practitioners. Lastly, we present the suite of benchmark and challenge problems developed for the GTO-CCS, providing problem descriptions and sample solutions.

15 GEOTHERMAL ENERGY↗