Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diagnosability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Spectral gap of shear Alfven waves in a periodic array of magnetic mirrors

A multiple magnetic mirror array is formed at the Large Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)] to study axial periodicity-influenced Alfven spectra. Shear Alfven waves (SAW) are launched by antennas inserted in the LAPD plasma and diagnosed by B-dot probes at many axial locations. Alfven wave spectral gaps and continua are formed similar to wave propagation in other periodic media due to the Bragg effect. The measured width of the propagation gap increases with the modulation amplitude as predicted by the solutions to Mathieu's equation. A two-dimensional finite-difference code modeling SAW in a mirror array configuration shows similar spectral features. Machine end-reflection conditions and damping mechanisms including electron-ion Coulomb collision and electron Landau damping are important for simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional global fluid simulations of cylindrical magnetized plasmas

Plasma dynamics in cylindrical geometry, with many well diagnosed experiments in operation worldwide, is of fundamental interest. These linear machines can provide an unique testing ground for direct and detailed comparisons of numerical simulations of nonlinear plasma dynamics with experiments. Thus, it is possible to assess the reproductive and predictive capabilities of plasma simulations in unprecedented detail. Here, three-dimensional global fluid simulations of a cylindrical magnetized plasma are presented. This plasma is characterized by the existence of spatially localized sources and sinks. The traditional scale separation paradigm is not applied in the simulation model to account for the important evolution of the background profiles due to the dynamics of turbulent fluctuations. Furthermore, the fluid modeling of sheath boundary conditions, which determine the plasma conditions, are an important ingredient to the code presented here. The linear properties of the model equations are studied and are shown to agree well with experimental observations of linear drift modes. The fully nonlinear simulations are characterized by turbulent fluctuations, which are dominated by low mode numbers in the large radial pressure gradient region. In the far plasma edge, the fluctuations display an intermittent character due to convection within radially extended spatiotemporal potential fluctuations. This paper reports on the model and general code results, while the detailed comparison to a specific experiment is left to a follow-up paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A microwave-induced plasma source: Characterization and application for the fast deposition of crystalline silicon films

A microwave-induced plasma source is developed and is applied for the fast deposition of crystalline silicon films. In this paper, the plasma source is diagnosed first. Electron density, electron temperature, and discharge gas temperature of the plasmas generated in ambient air are studied using the optical emission spectroscopy method. The electron density is estimated by analyzing the Stark broadening of the hydrogen H{sub {beta}} emission profile and is found to be as high as >10{sup 15} cm{sup -3} over wide conditions. The Boltzmann plot method is used to calculate the electron temperature, which shows a value smaller than 1 eV. Analysis of the rotational structure of OH molecular emission reveals a discharge gas temperature in a range of {approx}400-800 deg. C. Preliminary efforts of using the plasma source for Si film fast deposition are performed at a reduced pressure by using SiCl{sub 4} as the source gas. A fast deposition rate of 150 nm/s has been achieved for Si film with a high Raman crystallinity of I{sub c}/I{sub a}>10 even without using substrate heating and under a low H{sub 2} dilution condition. Mechanisms for these results are discussed in detail.

36 MATERIALS SCIENCE↗

From Femtosecond Dynamics to Breast Cancer Diagnosis by Raman Spectroscopy

This paper presents new results based on Raman spectroscopy and demonstrates its utilisation as a diagnostic and development tool with the key advantage in breast cancer research. Applications of Raman spectroscopy in cancer research are in the early stages of development. However, research presented here as well as performed in a few other laboratories demonstrate the ability of Raman spectroscopy to accurately characterize cancer tissue and distinguish between normal, malignant and benign types. The main goals of bio-Raman spectroscopy at this stage are threefold. Firstly, the aim is to develop the diagnostic ability of Raman spectroscopy so it can be implemented in a clinical environment, producing accurate and rapid diagnoses. Secondly, the aim is to optimize the technique as a diagnostic tool for the non-invasive real time medical applications. Thirdly, the aim is to formulate some hypothesis based on Raman spectroscopy on the molecular mechanism which drives the transformation of normal human cells into highly malignant derivatives. To the best of our knowledge, this is the most statistically reliable report on Raman spectroscopy-based diagnosis of breast cancers among the world women population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NIMROD resistive magnetohydrodynamic simulations of spheromak physics

The physics of spheromak plasmas is addressed by time-dependent, three-dimensional, resistive magnetohydrodynamic simulations with the NIMROD code [C. R. Sovinec et al., J. Comput. Phys. 195, 355 (2004)]. Included in some detail are the formation of a spheromak driven electrostatically by a coaxial plasma gun with a flux-conserver geometry and power systems that accurately model the sustained spheromak physics experiment [R. D. Wood et al., Nucl. Fusion 45, 1582 (2005)]. The controlled decay of the spheromak plasma over several milliseconds is also modeled as the programmable current and voltage relax, resulting in simulations of entire experimental pulses. Reconnection phenomena and the effects of current profile evolution on the growth of symmetry-breaking toroidal modes are diagnosed; these in turn affect the quality of magnetic surfaces and the energy confinement. The sensitivity of the simulation results addresses variations in both physical and numerical parameters, including spatial resolution. There are significant points of agreement between the simulations and the observed experimental behavior, e.g., in the evolution of the magnetics and the sensitivity of the energy confinement to the presence of symmetry-breaking magnetic fluctuations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Ion Collective Thomson Scattering Diagnostic for ITER - Progress of Design

In the era of high power and burning plasma fusion experiments with significant populations of fast particles, the diagnosis of fast ion dynamics becomes an important topic. In ITER, populations of fast ions due to ICRH and NBI, as well as fusion born alphas will carry a significant fraction of the free energy of the plasma. This may affect instabilities and transport in the plasma. A key candidate for diagnosing confined fast ions in ITER is the technique of collective Thomson scattering (CTS). A fast ion CTS system with a probing frequency of 60 GHz has been proposed for ITER. Based on diagnostic experience from particularly TEXTOR and ASDEX Upgrade, work is now progressing towards a final design of a fast ion CTS diagnostic for ITER. The biggest challenge of the diagnostic design is the HFS receiver located in the restricted space behind the blanket modules. Calculations and a series of mock-up measurements have brought the design towards a four mirror quasi-optical solution. The development as well as the present design will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Imaging Spectrometer for Recording Calibrated Time-Resolved K-Shell Spectra from Magnetically Confined Fusion Plasmas

Based on transmission crystal spectrometers recently optimized for recording high-resolution K-shell spectra from laser generated plasmas, an imaging spectrometer has been designed to record Mo and W K-shell spectra from magnetically confined plasmas. The spectrometer can be used to diagnose the electron energy distribution and transport of metal ions from the wall and divertor to the core plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The CXRS diagnostic for ITER and the CXRS-Pilot Experiment on TEXTOR

Charge eXchange Recombination Spectroscopy (CXRS) will play a crucial role in the diagnosing of burning plasmas: items like helium ash, transport barriers, impurity content or fuel ratio can all be assessed with CXRS. In fact this is the only direct method to obtain information about the light impurity ions, such as temperature, concentrations and rotation, in the core of the plasma. Two of such systems are foreseen at ITER, one in the upper port plug and one on the equatorial level, both viewing the 100 keV diagnostic H-beam.Challenges for this diagnostic development project are: constructing a mirror close to the plasma able to keep its reflectivity under the extreme bombardment by neutrons, erosion by fast neutrals and deposition of sputtered material, design of an optical labyrinth with well enough neutron shielding, developing spectrometers with a throughput about a factor 100 larger than on present day devices, with a similar or better dispersion, calibration and alignment techniques and last but not least, finding ways to obtain the physics relevant information from the measured complicated spectra in real time.With all these issues in mind, an ITER-CXRS pilot experiment has been developed and became operational on the TEXTOR tokamak, to address some of the above aspects. The results of this show the feasibility and the sensitivity of the ITER system: the simulation code for ITER signal levels could be verified, the sensitivity to the current profile has been tested, the beam emission has been compared to beam attenuation calculations and used to obtain absolute impurity concentrations and a high throughput spectrometer became operational.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Role of Fusion Product Measurements in Physics Understanding of a Burning Plasma

The roles of fusion products in diagnosing plasmas are quite diversified and rich in scientific content. From the early days to the new frontier of burning plasmas, the study of fusion products has allowed a deeper understanding of the physics found in these plasmas, spanning all configurations, in both magnetic and inertial confinement. In many early experiments, the measurement of plasma performance was based almost entirely on neutron yield measurements. Since then, the capability to measure fusion products has grown tremendously, and many new measuring techniques have been successfully tested and used in experiments. The first role is based on single-particle diagnosis, which can yield important information on performance, confinement, source and current profiles, plasma fluctuations, effects of ripples, MHD mode structure, etc. The second role, which has expanded tremendously in the last few years, includes the diagnosis of collective effects, which can yield additional information on instabilities, heating, and many others. This scientific capability is enhanced by the large number of fusion products (neutrons, charged particles, gammas) generated by the primary or secondary fusion processes such as the commonly studied, D+D, D+T and D+{sup 3}He reactions. This paper will review the applications of fusion product measurements used in the scientific study of plasma confinement and stability, and will describe the prospects and opportunities offered in burning plasma experiments such as ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SOFT-X RAY DIAGNOSTICS AND TREATMENTS FOR FUTURE REAL TIME APPLICATIONS

This paper offers a preliminary review of the present diagnostics and data analysis techniques in the domain of Soft X-ray (SXR) emissions of fusion magnetic plasmas, including a short description of the theoretical background as well. Particular attention is devoted to the wide use of SXR tomography and impurity transport simulation. In their actual form, these techniques are not adequate to future real time applications. For this goal a step forward in the diagnosing and analysis of SXR emissions is required. The following part of the paper is therefore dedicated to the discussion of these improvements. The first one is the SXR tomography optimized for real time applications, like that one developed at Tore Supra (Cadarache, France). Fast 2-D tomographic inversions using different techniques (regularisation of Minimum Fisher, Maximum entropy, Zernicke polynomial expansions), will be optimized to be performed in a few millisecond time scale, crucial for MHD analysis, mode detection and localisation. The other goal to be pursued is the energy resolved imaging, now possible with a gas Micro Pattern Gas Detector with pixel read-out, as recently demonstrated at FTU (Frascati, Italy) and at NSTX (Princeton NJ, US), together with an ad hoc modeling of SXR emissions, compatible with future real time applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear magnetohydrodynamics of pulsed parallel current drive in reversed-field pinches

Nonlinear simulation with a simple resistive magnetohydrodynamics model is used to investigate the stabilization of magnetic fluctuations in reversed-field pinch plasmas subject to pulsed-parallel current drive. Numerical results are diagnosed with computations of nonlinear power transfer and by evaluating sequences of profiles for linear stability. Results show that poloidal electric field pulsing promptly affects the exchange of energy between the mean profiles and both core-resonant m=1 fluctuations and high-axial-wavenumber fluctuations. Linear computations show that slight changes in edge profiles are sufficient to alter the stability of the marginal state. There is a slight delay in the response of energy exchanged among fluctuations, which reduces the m=0 fluctuations. Loss of dynamo effect as fluctuation amplitudes decrease leads to nonlocal pulse penetration that enhances pinching when toroidal drive is maintained. Reducing toroidal drive together with the application of poloidal electric field avoids pinching and maintains the stabilizing effect for a greater period of time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma-Ray Transmission Scans of Naphtha Splitter Column: A Case Study

The gamma-ray transmission technique is well known and widely used to on-line examine inner details of industrial process column. For that purpose, a particular case study was conducted to diagnose the performance of a Naphtha Splitter Column in real time at one petrochemical plant in Malaysia. The technique employed Co-60 as a radioisotope sealed source to emit gamma radiation and a NaI(TI) scintillation as detector. This technique provides a visible representation of the true nature of the naphtha splitter column wherein the process and mechanical problems inside the column can be identified while it is in operation. This paper demonstrates details of the technique used and shows the result obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-rf creation and diagnostics of seeded atmospheric pressure air and nitrogen plasmas

A laser initiation and radio frequency (rf) sustainment technique has been developed and improved from our previous work to create and sustain large-volume, high-pressure air and nitrogen plasmas. This technique utilizes a laser-initiated, 15 mTorr partial pressure tetrakis (dimethylamino) ethylene seed plasma with a 75 Torr background gas pressure to achieve high-pressure air/nitrogen plasma breakdown and reduce the rf power requirement needed to sustain the plasma. Upon the laser plasma initiation, the chamber pressure is raised to 760 Torr in 0.5 s through a pulsed gas valve, and the end of the chamber is subsequently opened to the ambient air. The atmospheric-pressure plasma is then maintained with the 13.56 MHz rf power. Using this technique, large-volume (1000 cm{sup 3}), high electron density (on the order of 10{sup 11-12} cm{sup -3}), 760 Torr air and nitrogen plasmas have been created while rf power reflection is minimized during the entire plasma pulse utilizing a dynamic matching method. This plasma can project far away from the antenna region (30 cm), and the rf power budget is 5 W/cm{sup 3}. Temporal evolution of the plasma electron density and total electron-neutral collision frequency during the pulsed plasma is diagnosed using millimeter wave interferometry. Optical emission spectroscopy (OES) aided by SPECAIR, a special OES simulation program for air-constituent plasmas, is used to analyze the radiating species and thermodynamic characteristics of the plasma. Rotational and vibrational temperatures of 4400-4600{+-}100 K are obtained from the emission spectra from the N{sub 2}(2+) and N{sub 2}{sup +}(1-) transitions by matching the experimental spectrum results with the SPECAIR simulation results. Based on the relation between the electron collision frequency and the neutral density, utilizing millimeter wave interferometry, the electron temperature of the 760 Torr nitrogen plasma is found to be 8700{+-}100 K (0.75{+-}0.1 eV). Therefore, the plasma deviates significantly from local thermal equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme ultraviolet spectroscopy of low-Z ion plasmas for fusion applications

The study of impurities is a key component of magnetic fusion research as it is directly related to plasma properties and steady-state operation. Two of the most important low-Z impurities are carbon and oxygen. The appropriate method of diagnosing these ions in plasmas is extreme ultraviolet (EUV) spectroscopy. In this work the results of two different sets of experiments are considered, and the spectra in a spectral region from 40 to 300 A are analyzed. The first set of experiments was carried out at the Sustained Spheromak Physics Experiment at LLNL, where EUV spectra of oxygen ions were recorded. The second set of experiments was performed at the compact laser-plasma x-ray/EUV facility 'Sparky' at UNR. In particular, Mylar and Teflon slabs were used as targets to produce carbon, oxygen, and fluorine ions of different ionization stages. Nonlocal thermodynamic equilibrium kinetic models of O, F, and C were applied to identify the most diagnostically important spectral features of low-Z ions between 40 to 300 A and to provide plasma parameters for both sets of experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of filament geometry on the arc efficiency of a high-intensity He{sup +} ion source

A strongly focusing high-intensity He{sup +} ion source equipped with three concave electrodes has been designed and constructed as the beam source for a high-energy He{sup 0} neutral beam probe system to diagnose fusion-produced alpha particles in thermonuclear fusion plasmas. The reduction of heat load onto the concave extraction electrodes is particularly important for a long pulse operation, as the heat load deforms the electrodes and thus the beam focal length. The effects on the arc efficiency (beam current/arc power) of the ion source due to the discharge filament structure (straight-type and L-shape-type filaments), size (filament diameters of 2 and 1.5 mm), number, and the locations have been studied. Choice of the appropriate filament structure improved the arc efficiency by 17%.

43 PARTICLE ACCELERATORS↗

Development and research of a coaxial microwave plasma thruster

An overview of the research on a coaxial microwave plasma thruster at Northwestern Polytechnic University is presented. Emphasis is put on the development and research on key components of the thruster system, a microthrust balance, plasma plume diagnostics, and a numerical simulation of the plasma flow field inside the thruster cavity. The developed thruster cavity is chosen from a coaxial resonant cavity with concentrated capacitance, which can operate well in atmosphere and vacuum conditions. The development of a microwave source shows that a magnetron powered by a switch power supply has advantages in the power level and efficiency, but a solid state microwave source synthesized from the arsenide field effect transistor is superior in weight and volume. Through elimination of the effect of large gravity and resistance force induced by a gas pipe line and a microwave transmitting line on the microthrust, 15 mN and 340 s in the performance of the microwave plasma thruster at 70 W and with helium gas are measured. Diagnosing experiment shows that the plasma plume density is in the range of (1-7.2)x10{sup 16}/m{sup 3}. Numerical simulation of the plasma flow field inside the coaxial thruster cavity shows that there is a good match between the microwave power and gas flow rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatially resolved high resolution x-ray spectroscopy for magnetically confined fusion plasmas (invited)

The use of high resolution x-ray crystal spectrometers to diagnose fusion plasmas has been limited by the poor spatial localization associated with chord integrated measurements. Taking advantage of a new x-ray imaging spectrometer concept [M. Bitter et al., Rev. Sci. Instrum. 75, 3660 (2004)], and improvements in x-ray detector technology [Ch. Broennimann et al., J. Synchrotron Radiat. 13, 120 (2006)], a spatially resolving high resolution x-ray spectrometer has been built and installed on the Alcator C-Mod tokamak. This instrument utilizes a spherically bent quartz crystal and a set of two dimensional x-ray detectors arranged in the Johann configuration [H. H. Johann, Z. Phys. 69, 185 (1931)] to image the entire plasma cross section with a spatial resolution of about 1 cm. The spectrometer was designed to measure line emission from H-like and He-like argon in the wavelength range 3.7 and 4.0 A with a resolving power of approximately 10 000 at frame rates up to 200 Hz. Using spectral tomographic techniques [I. Condrea, Phys. Plasmas 11, 2427 (2004)] the line integrated spectra can be inverted to infer profiles of impurity emissivity, velocity, and temperature. From these quantities it is then possible to calculate impurity density and electron temperature profiles. An overview of the instrument, analysis techniques, and example profiles are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conversion efficiency of high-Z backlighter materials

High-Z backlighter materials are commonly used as x-ray sources for diagnosing laser-driven experiments. In order to properly plan for experiments and analyze the data, it is important to understand both the number and distribution of photons emitted by the x-ray source when it is irradiated by a laser. The conversion efficiency of L-shell and M-shell emitters is not as well understood as K-shell emitters. The conversion efficiency of the former is typically presented in terms of the entire L- or M-shell spectral region. However, for some applications, one may only want to use a subset of this spectral region. Laser conversion efficiency for L-shell and M-shell emitters suitable for high-energy (>3 keV) absorption spectroscopy is presented at multiple laser intensities. The measured conversion efficiency of the materials ranges from 0.2% to 0.6%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗