Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

RaDIATE Collaboration Thermal shock studies

As next-generation accelerator target facilities (High Energy Physics, Spallation Sources, ... ) become increasingly more powerful and intense, high power target systems face key technical challenges, such as radiation damage and thermal shock. Those ultimately degrade the performance and lifetime of targets and have been identified as the leading cross-cutting challenges of high-power target facilities. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase for next generation accelerators, the RaDIATE Collaboration (Radiation Damage In Accelerator Target Environment), established in 2012 and managed by Fermilab, brings together existing expertise in nuclear material and accelerator targets from 20 international institutions, including CERN, to execute a coordinated strategy for high power targetry R&D. In this context, several thermal shock studies were performed at CERN's HiRadMat (High-Radiation to Materials) facility, that took a key step towards improving our knowledge on target damage tolerance. The first experiment HRMT-24, supported by EURCARD2 and completed in 2015, successfully validated the Johnson-Cook strength model developed at SwRI on beryllium S200FH (used for beam window material), providing a better confidence in simulating the thermal shock response of current and future S200FH beryllium components. HRMT-43, supported by ARIES and completed in 2018, tested various materials (Be, C, SiC, Si, Ti and ceramic nanofiber). It was a first and unique test which included pre-irradiated specimens from high energy proton beam irradiation to identify thermal shock response differences between non-irradiated and previously irradiated materials. Real-time measurement of dynamic thermomechanical response of graphite helped to benchmark numerical simulations.

43 PARTICLE ACCELERATORS↗

Creating and Probing Large Gap 2D Topological Insulators for Quantum Computing (Final Report)

Research under this award focused on experimental and theoretical efforts in developing and characterizing 2D topological insulators (TIs). Key areas of investigation included materials synthesis, device fabrication and characterization, and theoretical advancements. The team synthesized ZrTe 5 , a material with potential for TI phases. Additionally, the team pursued the synthesis of elemental thin films like Indene and Bismuthene, known for their large TI gaps. Indene was successfully stabilized on SiC. Another approach involved stacking and twisting transition metal dichalcogenides (TMDs) to engineer desired TI band structures. On the theoretical front, advancements made under this award predicted remarkable topological properties in twisted WSe2 bilayers, motivating experimental efforts to realize these states. Regarding device fabrication and characterization, significant progress was made in reducing contact resistance, crucial for reliable transport measurements. Contactless Pulsed Tunneling Spectroscopy (CPTS) was employed to study the electronic properties of WTe 2 and WSe 2 . However, challenges in device fabrication and electrode material selection hampered efforts to obtain desired spectra. Ancillary work, utilizing pulsed electrical methods, on the study of sliding ferroelectrics yielded impactful results demonstrating high speed operation and lack of degradation of devices after many billions of cycles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING↗

The National Criticality Experiments Research Center and its role in support of advanced reactor design

The National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS) in the Device Assembly Facility (DAF) and operated by Los Alamos National Laboratory (LANL) is the only general purpose critical experiments facility in the United States. Experiments from subcritical to critical and above prompt critical are carried out at NCERC on a regular basis. In recent years, NCERC has become more involved in experiments related to nuclear energy, including the Kilopower/KRUSTY demonstration and the recent Hypatia experiment. Multiple nuclear energy related projects are currently ongoing at NCERC. This paper discusses NCERC’s role in advanced reactor design and how that role may change in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Formation of field-induced breakdown precursors on metallic electrode surfaces

Understanding the underlying factors responsible for higher-than-anticipated local field enhancements required to trigger vacuum breakdown on pristine metal surfaces is crucial for the development of devices capable of withstanding intense operational fields. In this study, we investigate the behavior of nominally flat copper electrode surfaces exposed to electric fields of hundreds of MV/m. Our novel approach considers curvature-driven diffusion processes to elucidate the formation of sharp breakdown precursors. To do so, we develop a mesoscale finite element model that accounts for driving forces arising from both electrostatic and surface-tension-induced contributions to the free energy. Our findings reveal a dual influence: surface tension tends to mitigate local curvature, while the electric field drives mass transport toward regions of high local field density. This phenomenon can trigger the growth of sharper protrusions, ultimately leading to a rapid enhancement of local fields and, consequently, to a runaway growth instability. We delineate supercritical and subcritical regimes across a range of initial surface roughness. Our numerical results are in qualitative agreement with experimentally reported data, indicating the potential practical relevance of field-driven diffusion in the formation of breakdown precursors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supervisory Algorithm for Autonomous Hemodynamic Management Systems

Future military conflicts will require new solutions to manage combat casualties. The use of automated medical systems can potentially address this need by streamlining and augmenting the delivery of medical care in both emergency and combat trauma environments. However, in many situations, these systems may need to operate in conjunction with other autonomous and semi-autonomous devices. Management of complex patients may require multiple automated systems operating simultaneously and potentially competing with each other. Supervisory controllers capable of harmonizing multiple closed-loop systems are thus essential before multiple automated medical systems can be deployed in managing complex medical situations. The objective for this study was to develop a Supervisory Algorithm for Casualty Management (SACM) that manages decisions and interplay between two automated systems designed for management of hemorrhage control and resuscitation: an automatic extremity tourniquet system and an adaptive resuscitation controller. SACM monitors the required physiological inputs for both systems and synchronizes each respective system as needed. We present a series of trauma experiments carried out in a physiologically relevant benchtop circulatory system in which SACM must recognize extremity or internal hemorrhage, activate the corresponding algorithm to apply a tourniquet, and then resuscitate back to the target pressure setpoint. SACM continues monitoring after the initial stabilization so that additional medical changes can be quickly identified and addressed, essential to extending automation algorithms past initial trauma resuscitation into extended monitoring. Overall, SACM is an important step in transitioning automated medical systems into emergency and combat trauma situations. Future work will address further interplay between these systems and integrate additional medical systems.

42 ENGINEERING↗

Digital-to-analog converter operates from low level inputs

Circuit controls a voltage controlled oscillator from computer output binary data representing a rate at which the oscillator is to change. It operates with low level output devices such as integrated circuit registers and devices with somewhat variable output levels.

Winkelstein, R. A.↗

Eye point-of-regard system

System measures intersection of line of sight and eye point of regard /EPR/ for a human operator in visual scanning system. Device measures two head to reference angles with EPR system and adds them with eye to head angles, yielding a dc signal proportional to picture plane coordinates.

Jex, H. R.↗

Miniature biotelemeter gives multichannel wideband biomedical data

A miniature biotelemeter was developed for sensing and transmitting multiple channels of biomedical data over a radio link. The design of this miniature, 10-channel, wideband (5 kHz/channel), pulse amplitude modulation/ frequency modulation biotelemeter takes advantage of modern device technology (e.g., integrated circuit operational amplifiers, complementary symmetry/metal oxide semiconductor logic, and solid state switches) and hybrid packaging techniques. The telemeter is being used to monitor 10 channels of neuron firings from specific regions of the brain in rats implanted with chronic electrodes. Design, fabrication, and testing of an engineering model biotelemeter are described.

Carraway, J. B.↗

Vertical motion requirements for landing simulation

Tests were conducted to determine the significance of vertical acceleration cues in the simulation of the visual approach and landing maneuver. Landing performance measures were obtained for four subject pilots operating a visual landing simulation device which provides up to plus or minus 40 feet of vertical motion. Test results indicate that vertical motion cues are utilized in the landing task, and that they are particularly important in the simulation of aircraft with marginal longitudinal handling qualities. To assure vertical motion cues of the desired fidelity in the landing tasks, it appears that a simulator must have excursion capabilities of at least plus or minus 20 feet.

Bray, R. S.↗

Derivation of a tangent function using an integrated circuit four-quadrant multiplier

A tangent function generator is provided which utilizes input signals proportionate to the sine and cosine of a given angle. The equipment accomplishes a trigonometric manipulation which forms an output signal substantially independent of the input reference voltage but proportional to the tangent of the angle. The device uses a multiplier and operational amplifier.

Bregman, B. J.↗

Shuttle mission simulator baseline definition report, volume 2

The baseline definition report for the space shuttle mission simulator is presented. The subjects discussed are: (1) the general configurations, (2) motion base crew station, (3) instructor operator station complex, (4) display devices, (5) electromagnetic compatibility, (6) external interface equipment, (7) data conversion equipment, (8) fixed base crew station equipment, and (9) computer complex. Block diagrams of the supporting subsystems are provided.

Dahlberg, A. W.↗

Preliminary flight tests of an oculometer

A remote sensing oculometer has been successfully operated during flight tests. This device was able to track the pilot's eye-point-of-regard (lookpoint) consistently and unobtrusively in the flight environment. The instantaneous position of the lookpoint was determined to within approximately 1 degree. Data were recorded on both analog and video tape. The video data consisted of continuous scenes of the aircraft's instrument display and a superimposed white dot (simulating the lookpoint) dwelling or moving from instrument to instrument as the pilot monitored the display information during landing approaches.

Middleton, D. B.↗

A new real-time non-coherent to coherent light image converter - The hybrid field effect liquid crystal light valve

A new, high-performance device has been developed for application to real-time coherent optical data processing. The new device embodies a CdS photoconductor, a CdTe light-absorbing layer, a dielectric mirror, and a liquid crystal layer sandwiched between indium-tin-oxide transparent electrodes deposited on optical quality glass flats. The noncoherent image is directed onto the photoconductor; this reduces the impedance of the photoconductor, thereby switching the ac voltage that is impressed across the electrodes onto the liquid crystal to activate the device. The liquid crystal is operated in a hybrid field effect mode. It utilizes the twisted nematic effect to create a dark off-state and the optical birefringence effect to create the bright on-state. The liquid crystal modulates the polarization of the coherent read-out light so an analyzer must be used to create an intensity modulated output beam.

Grinberg, J.↗

Fast pressure-sensor system

Miniature silicon-diaphragm sensors and signal multiplexer are mounted to ganged zero-operate-calibrate pressure selector switches. Device allows in-situ calibration, can be computer controlled, and measures at approximately 10,000 readings per second.

Gross, C.↗

The practical operational-amplifier gyrator circuit for inductorless filter synthesis

A literature is reported for gyrator circuits utilizing operational amplifiers as the active device. A gyrator is a two port nonreciprocal device with the property that the input impedance is proportional to the reciprocal of the load impedance. Following an experimental study, the gyrator circuit with optimum properties was selected for additional testing. A theoretical analysis was performed and compared to the experimental results for excellent agreement.

Sutherland, W. C.↗