Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deployables”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Postdisaster Routing of Movable Energy Resources for Enhanced Distribution System Resilience: A Deep Reinforcement Learning-Based Approach

The deployment of movable energy resources (MERs) can be an effective strategy to restore critical loads to enhance power system resilience when no other energy sources are available after the occurrence of an extreme event. Since the optimal locations of MERs following an extreme event are dependent on system operating states (e.g., the loads at each node, on/off status of system branches, and so on), existing analytical and population-based approaches must repeat the entire analysis and calculation when the system operating states change. On the contrary, if deep reinforcement learning (DRL)-based algorithms are sufficiently trained with a wide range of scenarios, they can quickly find optimal or near-optimal locations irrespective of changes in system states. A deep Q-learning-based approach is proposed for optimal MER deployment to enhance power system resilience. MERs can be also utilized to complement other types of resources, if available. The proposed approach operates in two stages after the occurrence of extreme events. In the first stage, the distribution network is represented as a graph, and the network is then reconfigured using tie switches by using Kruskal’s spanning forest search algorithm (KSFSA). To maximize critical load recovery, the optimal or near-optimal locations of MERs are chosen in the second stage. Further, case studies on a 33-node distribution system and a modified IEEE 123-node system demonstrate the effectiveness of the proposed approach for postdisaster routing of MERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predictive-Maintenance Practices: For Operational Safety of Battery Energy Storage Systems

Changes in the Demand Profile and a growing role for renewable and distributed generation are leading to rapid evolution in the electric grid. These changes are beginning to considerably strain the transmission and distribution infrastructure. Utilities are increasingly recognizing that the integration of energy storage in the grid infrastructure will help manage intermittency and improve grid reliability. This recognition, coupled with the proliferation of state-level renewable portfolio standards and rapidly declining lithium-ion (Li-ion) battery costs, has led to a surge in the deployment of battery energy storage systems (BESSs). Additionally, although BESSs represented less than 1% of grid-scale energy storage in the United States in 2019, they are the preferred technology to meet growing demand because they are modular, scalable, and easy to deploy across diverse use cases and geographic locations.

25 ENERGY STORAGE↗

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Blockchain Based Co-Simulation Framework for Integrating DERs to Wholesale Electricity Markets

As the number of distributed energy resources (DERs) continue to increase across energy-delivery systems, there remains a need for integrating their capabilities into traditional grid operations. In this paper, a blockchain-based solution is proposed to facilitate FERC's Order No. 2222 implementations. The presented use-case enables small-scale DERs to participate in wholesale market operations through DER aggregators, while also enabling local distribution system operators to enforce distribution system constraints in a secure and traceable manner. The presented use case is built around the Unified Testing Platform (UTP) being developed as a part of the Blockchain for Optimized Security and Energy Management (BLOSEM) project. This is a multi-lab effort intended to simplify the deployment of blockchain-powered grid solutions by enabling the integration of simulation tools, and blockchain technologies through the use of system-agnostic interfaces that provide a modular, interoperable, and reusable connectivity layer.

blockchain interoperability↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Estimating Spatial Distribution Impacts of Rooftops Solar PV on Dynamic Hosting Capacity Evaluation for a Real Distribution Feeder

This paper models the sensitivity of dynamic hosting capacity analysis to the spatial distribution of distributed PV scenarios, random, close and far from substation deployments, at various penetration levels on a real distribution feeder, in a quasi-static time series (QSTS) power flow simulation using high resolution time-aware metrics. These spatial distribution scenarios were chosen to capture a wide range of potential operation impacts of these deployments using a set of thermaland voltage-based metrics such as instantaneous violations and moving averages for both thermal and voltage constraints. This study uses actual load and PV data up-scaled from 1-hour time step to 1-minute resolution to fully characterize the interaction between the daily changes in load and PV output, and their impacts on distribution system operations.

distribution system↗

Local Resistance Measurement for Degradation of c-Si Heterojunction with Intrinsic Thin Layer (HIT) Solar Modules

Silicon heterojunction with intrinsic thin layer (or HIT) modules typically degrade at a rate of less than 1% annually in solar fields with dominant degradation in open-circuit voltage and some degradation in series resistance. However, detailed mechanisms can differ from module to module. Here, we study increases in local series resistance that occur over long-term field deployment, indicated by cell areas where the photoluminescence intensity does not degrade but the electroluminescence degrades significantly. To directly measure the local series resistance, we have cored out the local electroluminescence-degraded area, and we measured the sheet resistance by 4-point-probe and local nm-scale resistance using scanning spreading resistance microscopy (SSRM). The results by 4-point-probe show scattered sheet resistance that can be caused, for example, by nonuniform current paths through the transparent conductive oxide layer, the a-Si:H emitter, or the near-junction c-Si inversion layer. In contrast, the SSRM results indicate a relatively uniform and non-degraded resistivity on smaller nanometer spatial scales. SSRM is an atomic force microscopy-based two-terminal resistance mapping technique that measures the local resistance in nm-volume beneath the probe. The consistent resistances measured on the control and degraded samples can exclude the degradation of transparent conductive oxide resistance.

41 EE - Solar Energy Technologies Office (EE-4S)↗

An Analysis of Grid Operator Survey Responses: Inexperience, Workload and Fatigue in the Control Room

Although a wide array of tools and technologies have been developed over the last decade to support power grid operators, deployment of these tools has been less successful. One reason for unsuccessful deployment may be an inadequate understanding of the factors that contribute to operator error in the control room. An analysis of operators’ current vulnerabilities may provide the baseline understanding needed to inform new technology integration. In an attempt to learn more about these vulnerabilities and their perceived impact on human error we collected and analyzed survey data from 20 electric grid control room operators. We asked survey respondents to consider the various operator, technology and interaction vulnerabilities that may arise during work in the control room and record their attitudes and experiences toward each. Results suggest operator inexperience, high mental workload and fatigue are the most common vulnerabilities experienced during a shift. Survey results were analyzed to explore these vulnerabilities in greater depth.

Inexperience, Workload, Fatigue↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

Performance Evaluation of Vertical Federated Machine Learning Against Adversarial Threats on Wide-Area Control System: Preprint

Federated machine learning (FL) is gaining significant popularity to develop cybersecurity solutions in power grids because of its advanced capability to support decentralized data handing at local devices, its privacy preservation, and its low-bandwidth requirement. However, the evolving adversarial machine learning (AML) threats raise significant concerns for the cybersecurity of FL architectures. The FL-based split neural network (SplitNN) achieves high performance through the decentralized training of local neural network models while preserving data privacy across multiple entities. In this paper, we propose a methodology for evaluating the performance of a vertical FLbased anomaly detector against different types of AML attacks, including denial-of-service attacks, adversarial data injection attacks, and replay attacks on the trained local models deployed in the grid network. For a case study, we consider the modified IEEE 13-bus system, and we develop SplitNN-based binary and multiclass classification models to detect, locate, and identify different types of data integrity attacks on the volt-watt control with two pooling layers: maximum pooling and AvgPool. Our experimental results, computed through performance metrics, reveal that the severity of these AML attacks varies with the integrated pooling mechanism, the type of classification model, and the nature of the cyberattack. Further, the AML attacks negatively impacted the prediction time per sample for the pretrained SplitNN during the online testing.

adversarial threats↗

An Evaluation of the Effect of Network Cost Optimization for Leadership Class Supercomputers

Dragonfly-based networks are an extensively deployed network topology in large-scale high-performance computing due to their cost-effectiveness and efficiency. The US will soon have three Exascale supercomputers for leadership class workloads deployed using dragonfly networks. Compared to indirect networks of similar scale, the dragonfly network has considerably reduced cable lengths, cable counts, and switch counts, resulting in significant network cost savings for a given system size, however, these cost reductions result in reduced global minimal paths and more challenging routing. Additionally, large scale dragonfly networks often require a taper at the global link level, resulting in less bisection bandwidth than is achievable in other traditional non-blocking topologies of equivalent scale. While dragonfly networks have been extensively studied, they have yet to be fully evaluated in an extreme scale (i.e., exascale) system that targets capability workloads. In this paper, we present the results of the first large scale evaluation of a dragonfly network on an exascale system (Frontier) and compare its behavior to a similar scale fat-tree network on a previous generation TOP500 system (Summit). This evaluation aims to determine the effect of network cost optimizations by measuring a tapered topology’s impact on capability workloads. Our evaluation is based on a collection of synthetic microbenchmarks, mini-apps, and full scale applications. It compares the scaling efficiencies of each benchmark between the dragonfly-based Frontier and the fat-tree-based Summit systems. Our results show that a dragonfly network is $\sim \mathbf{3 0 \%}$ more cost efficient than a fat-tree topology, which amortizes to $\sim 3 \%$ of an exascale system cost. Furthermore, while tapered dragonfly networks impose significant tradeoffs, the impacts are not as broad as initially thought and are mostly seen in applications with global communication patterns, particularly all-to-all (e.g., FFT-based algorithms), but also local communication patterns (e.g., nearest-neighbor algorithms) that are sensitive to network performance variability.

Khan, Awais↗

Establish the basis for Breadth-First Search on Frontier System: XBFS on AMD GPUs

Graphics Processing Units (GPUs) offer significant potential for accelerating various computational tasks, including Breadth-First Search (BFS). Numerous efforts have been made to deploy BFS on GPUs effectively. To address the dynamic nature of BFS, XBFS, the state-of-the-art work, employs an adaptive strategy that leverages different optimized frontier queue generation designs, accommodating the varying characteristics of levels in BFS. While XBFS demonstrates excellent performance on NVIDIA Quadro P6000 GPUs, it faces challenges when deployed on AMD GPUs. In this work, we present our efforts to implement XBFS’s adaptive approach on Frontier, the most powerful supercomputer system, by porting XBFS to AMD MI250X GPUs. Through targeted optimizations tailored to the unique features of AMD GPUs, our implementation achieves an average performance of 43 Giga-Traversed Edges Per Second (GTEPS) per Graphics Compute Dies (GCD). Based on these results, we observe potential for surpassing the performance of the official Frontier results from the Graph500 benchmark released in June 2024.

Yang, Haoshen↗

Power and Communications Hardware-in-the-Loop CPS Architecture and Platform for DER Monitoring and Control Applications: Preprint

The rapid growth of distributed energy resources (DERs) has prompted increasing interest in the monitoring and control of DERs through hybrid smart grid communications. The deployment of communications and computation has transformed the traditional physical power grid into a smart cyber-physical system (CPS). To fully understand the interdependency between physical grid and cyber netowrks, this study designed a power and communications hardware-in-the-loop (PCommHIL) CPS architecture, which enables the flexible verification of DER monitoring and control with hybrid communications architectures and Internet protocols. Design, development and case study of a PCommHIL testbed for the DER coordination are discussed in detail, and the proposed platform integrates DER devices, Advanced Metering Infrastructures (AMIs), and a suite of hybrid communications networks for distribution automation applications. Case study on DER situational awareness and Volt-Var control validates the efficacy of this proposed PCommHIL platform with hybrid communications designs. Results show that the HAN communication technologies play a critical role in hybrid designs and it is the bottleneck for DER applications. High performance communication technologies are highly recommended to be applied in the HAN for enhanced monitoring and real-time control of DERs.

AMIs↗

Traffic Signal Optimization by Integrating Reinforcement Learning and Digital Twins

Machine learning (ML) methods, especially reinforcement learning (RL), have been widely considered for traffic signal optimization in intelligent transportation systems. Most of these ML methods are centralized, lacking in scalability and adaptability in large traffic networks. Further, it is challenging to train such ML models due to the lack of training platforms and/or the cost of deploying and training in a real traffic networks. This paper presents an approach for the integration of decentralized graph-based multi-agent reinforcement learning (DGMARL) with a Digital Twin (DT) to optimize traffic signals for the reduction of traffic congestion and network-wide fuel consumption related to stopping. Specifically, the DGMARL agents learn traffic state patterns and make decisions regarding traffic signal control with assistance from a Digital Twin module, which simulates and replicates the traffic behaviors of a real traffic network. The proposed approach was evaluated using PTV-Vissim [1], a microscopic traffic simulation platform. PTV-Vissim is also the simulation engine of the DT, enabling emulation and optimization of the traffic signals on the MLK Smart Corridor in Chattanooga, Tennessee. Compared to an actuated signal control baseline approach, experiment results show that Eco_PI, a developed performance measure capturing the impact of stops on fuel consumption, was reduced by 44.27% in a 24-hour and an average of 29.88% in a PM-peak-hour scenario.

Multi-Agent Reinforcement Learning, Digital Twin, ↗

Hardware-in-the-Loop Test Bed and Test Methodology for Microgrid Controller Evaluation

Increasing penetration levels of distributed energy resources are making the deployment of microgrids more feasible. Controllers that operate such microgrids are key to realizing the objectives of the microgrid owner or operator and there is a need to evaluate microgrid controller performance prior to field deployment. This paper describes a controller hardware-in-the-loop and power hardware-in-the-loop microgrid controller test bed that was designed and constructed to evaluate the capabilities of a microgrid controller for a proposed campus microgrid. This paper also presents a test methodology to evaluate microgrid controller functionality, and it describes how the controller was assessed through the application of different test scenarios. Results from the testing are presented to provide insight into the capabilities of the test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Role-Based Access Control Policy for Smart Grid Applications: An Offline Deep Reinforcement Learning Approach

Role-based access control (RBAC) is adopted in the information and communication technology domain for authentication purposes. However, due to a very large number of entities within organizational access control (AC) systems, static RBAC management can be inefficient, costly, and can lead to cybersecurity threats. In this paper, a novel hybrid RBAC model is proposed, based on the principles of offline deep reinforcement learning (RL) and Bayesian belief networks. The considered framework utilizes a fully offline RL agent, which models the behavioral history of users as a Bayesian belief-based trust indicator. Thus, the initial static RBAC policy is improved in a dynamic manner through off-policy learning while guaranteeing compliance of the internal users with the security rules of the system. By deploying our implementation within the smart grid domain and specifically within a Distributed Energy Resources (DER) ecosystem, we provide an end-to-end proof of concept of our model. Finally, detailed analysis and evaluation regarding the offline training phase of the RL agent are provided, while the online deployment of the hybrid RL-based RBAC model into the DER ecosystem highlights its key operation features and salient benefits over traditional RBAC models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗