Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Employing Sensitivity Derivatives to Estimate Uncertainty Propagation in CFD

Two methods that exploit the availability of sensitivity derivatives are successfully employed to predict uncertainty propagation through Computational Fluid Dynamics (CFD) code for an inviscid airfoil problem. An approximate statistical second-moment method and a Sensitivity Derivative Enhanced Monte Carlo (SDEMC) method are successfully demonstrated on a two-dimensional problem. First- and second-order sensitivity derivatives of code output with respect to code input are obtained through an efficient incremental iterative approach. Given uncertainties in statistically independent, random, normally distributed flow parameters (input variables); these sensitivity derivatives enable one to formulate first- and second-order Taylor Series approximations for the mean and variance of CFD output quantities. Additionally, incorporation of the first-order sensitivity derivatives into the data reduction phase of a conventional Monte Carlo (MC) simulation allows for improved accuracy in determining the first moment of the CFD output. Both methods are compared to results generated using a conventional MC method. The methods that exploit the availability of sensitivity derivatives are found to be valid when considering small deviations from input mean values.

Putko, Michele M.↗

Characterization and Uncertainty Analysis of a Reference Pressure Measurement System for Wind Tunnels

This paper presents the calibration results and uncertainty analysis of a high-precision reference pressure measurement system currently used in wind tunnels at the NASA Langley Research Center (LaRC). Sensors, calibration standards, and measurement instruments are subject to errors due to aging, drift with time, environment effects, transportation, the mathematical model, the calibration experimental design, and other factors. Errors occur at every link in the chain of measurements and data reduction from the sensor to the final computed results. At each link of the chain, bias and precision uncertainties must be separately estimated for facility use, and are combined to produce overall calibration and prediction confidence intervals for the instrument, typically at a 95% confidence level. The uncertainty analysis and calibration experimental designs used herein, based on techniques developed at LaRC, employ replicated experimental designs for efficiency, separate estimation of bias and precision uncertainties, and detection of significant parameter drift with time. Final results, including calibration confidence intervals and prediction intervals given as functions of the applied inputs, not as a fixed percentage of the full-scale value are presented. System uncertainties are propagated beginning with the initial reference pressure standard, to the calibrated instrument as a working standard in the facility. Among the several parameters that can affect the overall results are operating temperature, atmospheric pressure, humidity, and facility vibration. Effects of factors such as initial zeroing and temperature are investigated. The effects of the identified parameters on system performance and accuracy are discussed.

Amer, Tahani↗

Acquisition and processing of data for isotope-ratio-monitoring mass spectrometry

Methods are described for continuous monitoring of signals required for precise analyses of 13C, 18O, and 15N in gas streams containing varying quantities of CO2 and N2. The quantitative resolution (i.e. maximum performance in the absence of random errors) of these methods is adequate for determination of isotope ratios with an uncertainty of one part in 10(5); the precision actually obtained is often better than one part in 10(4). This report describes data-processing operations including definition of beginning and ending points of chromatographic peaks and quantitation of background levels, allowance for effects of chromatographic separation of isotopically substituted species, integration of signals related to specific masses, correction for effects of mass discrimination, recognition of drifts in mass spectrometer performance, and calculation of isotopic delta values. Characteristics of a system allowing off-line revision of parameters used in data reduction are described and an algorithm for identification of background levels in complex chromatograms is outlined. Effects of imperfect chromatographic resolution are demonstrated and discussed and an approach to deconvolution of signals from coeluting substances described.

NASA Discipline Exobiology↗

Isolated Roughness Induced Boundary-Layer Transition: Shuttle Orbiter Ground Tests and Flight Experience

Recent Orbiter wind tunnel data and flight data have been used to evaluate boundary-layer transition induced by discrete-roughness elements on the Orbiter windward surface. Orbiter flow field calculations have been used to compute transition parameters and disturbance parameters for correlating the results and comparing the trends. Existing transition correlations have been modified and applied to the Orbiter. These correlations provide a means to predict transition on the Orbiter given a known isolated roughness element. Furthermore, these data and data reduction methods provide information and guidance for the prediction of transition due to &screte-roughness elements on future winged reentry vehicles.

Bouslog, Stanley A.↗

Model Deformation Measurements at a Cryogenic Wind Tunnel Using Photogrammetry

A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility (NTF) is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. Data reduction procedures and the results of tunnel tests at the NTF are presented.

Burner, A. W.↗

A Wall Correction Program Based on Classical Methods for the National Transonic Facility (Solid Wall or Slotted Wall) and the 14x22-Ft Subsonic Tunnel at NASA LaRC

A Fortran subroutine CMWALL is described, which is an implementation of the collective information from classical methods-based wall corrections. These methods use established closed-form expressions which were developed based on simple linear potential-based methods. This is a simple and rapid tool to calculate corrections due to wall interference in the National Transonic Facility (Solid Wall or Slotted Wall) or the 14x22-Ft Subsonic Tunnel at NASA LaRC. It is designed to be easily implemented in the existing tunnel data reduction programs, either as real-time or post-point. It is however important to realize that the method is based on the simplifying assumptions of linearity, small model and attached flow. The computed results are thus to be viewed as first-cut estimates, to be refined further using more complex methods based on measured wall pressures (known as wall signature methods).

Hemsch, Michael J.↗

Lunar and Planetary Science XXXVI, Part 7

Topics discussed include: Lunar Geologic Mapping: Preliminary Mapping of Copernicus Quad High-Resolution Topography of Layers in the Valles Marineris Via Thermoclinometry ; The Critical Importance of Data Reduction Calibrations in the Interpretability of S-type Asteroid Spectra; (sup 238)U-(sup 206)Pb Age and Uranium-Lead Isotope Systematics of Mare Basalt 10017; Morphological Investigations of Martian Spherules, Comparisons to Collected Terrestrial Counterparts; The Vapor Pressure of Palladium at Temperatures up to 1973K; Areas of Favorable Illumination at the Lunar Poles Calculated from Topography; An Indigenous Origin for the South Pole-Aitken Basin Thorium Anomaly; Ar-Ar Ages of Nakhlites Y000593, NWA998, and Nakhla and CRE Ages of NWA998; Experiments on the Acoustic Properties of Titan-like Atmospheres; Analysis of Downstream Transitions in Morphology and Structure of Lava Channels on Mars; Structure and Bonding of Carbon in Clays from CI Carbonaceous Chondrites; Comparison of Three Hydrogen Distributions at the Equator of Mars; An Impact Origin for the Foliation of Ordinary Chondrites; A New Micrometeorite Collection from Antarctica and Its Preliminary Characterization by Microobservation, Microanalysis and Magnetic Methods; Volcanic Plumes and Plume Deposits on Io; Results of the Alpha-Particle-X-Ray Spectrometer on Board of the Mars Exploration Rovers; Effects of Oceans on Atmospheric Loss During the Stage of Giant Impacts; and Identification of Predominant Ferric Signatures in Association to the Martian Sulfate Deposits

Source record↗

The FUV Flux Irradiating the Surfaces of Protostellar Disks

This grant was intended for, and has been used for, the support of the specialized CalFUSE data reduction required for these non-standard observations. The goal of the program was to search for FUV continuum radiation from T-Tauri stars, which would have affected the chemistry in the proto-planetary disk. Because of the low flux expected, the standard background subtraction method would not be appropriate. Rather on-chip background determination was expected to be required.

Andersson, B.-G.↗

Automation, Operation, and Data Analysis in the Cryogenic, High Accuracy, Refraction Measuring System (CHARMS)

The Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA s Goddard Space Flight Center has been enhanced in a number of ways in the last year to allow the system to accurately collect refracted beam deviation readings automatically over a range of temperatures from 15 K to well beyond room temperature with high sampling density in both wavelength and temperature. The engineering details which make this possible are presented. The methods by which the most accurate angular measurements are made and the corresponding data reduction methods used to reduce thousands of observed angles to a handful of refractive index values are also discussed.

Frey, Bradley↗

Temperature Correction of Pressure-Sensitive Paints Simplified

Pressure-sensitive paint (PSP) has become a useful tool to augment conventional pressure taps in measuring the surface pressure distribution of aerodynamic components in wind tunnel testing. Although PSP offers the advantage of nonintrusive global mapping of the surface pressure, one prominent drawback to the accuracy of this technique is the inherent temperature sensitivity of PSP's luminescent intensity. Typical aerodynamic surface PSP tests rely on the coated surface to be both spatially and temporally isothermal, along with conventional instrumentation, to yield the highest accuracy pressure mappings. In some tests, however, spatial and temporal thermal gradients are generated by the nature of the test, as in a blowing jet impinging on a surface. In these cases, high accuracy and reliable data cannot be obtained unless the temperature variations on the painted surface are accounted for. A new temperature-correction technique was developed at the NASA Glenn Research Center at Lewis Field to collapse a "family" of PSP calibration curves to a single curve of intensity ratio versus pressure. This correction allows a streamlined procedure to be followed whether or not temperature information is used in the data reduction of the PSP.

Bencic, Timothy J.↗

Chapter 19A – Radar Cross Section

The material in this Section will provide the novice Flight Test Engineer (FTE) with a brief overview of the radar cross section (RCS) concept. Brief details of radar range descriptions, operations, target calibrations, and data reduction are included. It is noted that these range operations concentrate on the "static" test range rather than the much more sophisticated "dynamic" test range. The dynamic test range is what the FTE will probably work with. Radar reflectivity measurement has developed over the last two decades from a relatively simple endeavor involving the measurement of target RCS amplitude statistics to involving wide band, coherent systems that can measure high resolution images of targets as well as, in many cases, the polarization and phasing properties. This rapid growth in RCS technology has occurred because of the increased use of radar in today's commercial and military systems. In general, the goal for commercial systems is to enhance radar reflectivity, whereas the military goal is to reduce radar reflectivity. Also, classification and identification are important for military purposes because in adverse weather radar may be the only system that may be capable of separating enemy targets from friendly ones. This Section will discuss the fundamentals of RCS. Since the flight test techniques associated with RCS measurements are very similar to those of antenna pattern measurements, both will be presented at the same time in Section 19B Antenna Radiation Pattern Measurements.

Robert W Borek↗

Automation, Operation, and Data Analysis in the Cryogenic, High Accuracy, Refraction Measuring System (CHARMS)

The Cryogenic High Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center has been enhanced in a number of ways in the last year to allow the system to accurately collect refracted beam deviation readings automatically over a range of temperatures from 15 K to well beyond room temperature with high sampling density in both wavelength and temperature. The engineering details which make this possible are presented. The methods by which the most accurate angular measurements are made and the corresponding data reduction methods used to reduce thousands of observed angles to a handful of refractive index values are also discussed.

Frey, Bradley J.↗

Coronal thermal structure and abundances of supermetal-rich solar-type stars

This observation is for grating spectroscopy of Tau Boo, a late-type star with very high metallicity (about twice solar). Despite the extreme condition of high metallicity in the photosphere, the abundance ratios of the corona appear consistent with the general picture of a coronal abundance/activity relation. The target was obtained by XMM-Newton on 24 June 2003 for 71900 sec. The European PI Antonio Maggio is responsible for data reduction. Members of our team presented at the Cool Stars Workshop 13 held in Hamburg, Germany in July 2004 and conferred at that time on the publication of results. This project is complete except for the final publication.

Brickhouse, Nancy S.↗

NASA Processes and Requirements for Conducting Human-in-the-Loop Closed Chamber Tests

NASA has specific processes and requirements that must be followed for tests involving human subjects to be conducted in a safe and effective manner. There are five distinct phases of test operations. Phase one, the test request phase, consists of those activities related to initiating, processing, reviewing, and evaluating the test request. Phase two, the test preparation phase consists of those activities related to planning, coordinating, documenting, and building up the test. Phase three, the test readiness phase consists of those activities related to verifying and reviewing the planned test operations. Phase four, the test activity phase, consists of all pretest operations, functional checkouts, emergency drills, and test operations. Phase five, the post test activity phase, consists of those activities performed once the test is completed, including briefings, documentation of anomalies, data reduction and archiving, and reporting. Project management processes must be followed for facility modifications and major test buildup, which include six phases: initiation and assessment, requirements evaluation, preliminary design, detailed design, use readiness review (URR) and acceptance. Compliance with requirements for safety and quality assurance are documented throughout the test buildup and test operation processes. Tests involving human subjects must be reviewed by the applicable Institutional Review Board (IRB).

Barta, Daniel J.↗

A low cost imaging displacement measurement system for spacecraft thermal vacuum testing

A low cost imaging displacement technique suitable for use in thermal vacuum testing was built and tested during thermal vacuum testing of the space infrared telescope facility (SIRTF, later renamed Spitzer infrared telescope facility). The problem was to measure the relative displacement of different portions of the spacecraft due to thermal expansion or contraction. Standard displacement measuring instrumentation could not be used because of the widely varying temperatures on the spacecraft and for fear of invalidating the thermal vacuum testing. The imaging system was conceived, designed, purchased, and installed in approximately 2 months at very low cost. The system performed beyond expectations proving that sub millimeter displacements could be measured from over 2 meters away. Using commercial optics it was possible to make displacement measurements down to 10 (mu)m. An automated image processing tool was used to process the data, which not only speeded up data reduction, but showed that velocities and accelerations could also be measured. Details of the design and capabilities of the system are discussed along with the results of the test on the observatory. Several images from the actual test are presented.

thermal vacuum↗

Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

Fournelle, John↗